vegadif 65
Transkript
vegadif 65
Safety instructions VEGADIF DF65.UG*****Z/H/ P/F***** Installation Control Diagram Document ID: 42226 Contents 1 Area of applicability.................................................................................................................. 3 2 General information.................................................................................................................. 3 3 Technical data........................................................................................................................... 3 4 Application conditions............................................................................................................. 4 5 Protection against static electricity........................................................................................ 5 6Grounding.................................................................................................................................. 5 7 Impact and friction sparks....................................................................................................... 5 8 Material resistance................................................................................................................... 6 9 Ignition protection type explosion proof proof enclosure.................................................... 6 10Notes.......................................................................................................................................... 7 11 Installation Diagram................................................................................................................. 9 Please note: These safety instructions are part of the documentation: VEGADIF 65 –– 36236 - 4 … 20 mA –– 36128 - 4 … 20 mA/HART –– 36129 - Profibus PA –– 36130 - Foundation Fieldbus –– 52217 - Certificate of Compliance FM 3044382 42226-EN-151030 • Editing status: 2015-08-20 2 VEGADIF DF65.UG*****Z/H/P/F***** 1 Area of applicability 2 General information These safety instructions apply to differential pressure transmitters series VEGADIF DF65. UG*****Z/H/P/F***** according to FM Certificate of compliance No. 3044382 and for all instruments with the number of the safety instructions (42226) on the type label. The pressure measuring instruments VEGADIF DF65.UG*****Z/H/P/F***** are also used for differential pressure measurement in hazardous areas. The measured products can also be combustible liquids, gases, mist or vapour. VEGADIF DF65.UG*****Z/H/P/F***** consist of an electronics housing with an explosion proof connection compartment with barrier and an intrinsically safe connection compartment with integrated electronics module, a process fitting element and a sensor, the differential pressure measuring cell. The indicating and adjustment module can be optionally integrated in the intrinsically safe connection compartment. If the VEGADIF DF65.UG*****Z/H/P/F***** are installed and operated in hazardous areas, the general hazardous location regulations as well as these safety instructions must be observed. The operating instructions as well as the valid hazardous location mounting regulations and standards for electrical equipment must be observed. The installation of explosion-endangered systems must always be carried out by qualified personnel. Hazardous locations designation CI I, Zn 1, AEx d [ia] IIC Cl I, Div. 1, GR A, B, C, D Cl II, Div. 1, GR E, F, G Cl III 3 Technical data Electrical data The VEGADIF DF65.UG*****Z/H/P/F***** are designed with intrinsically and non-intrinsically safe circuits. Non-intrinsically safe circuits The non-intrinsically safe circuits are connected to terminals in the explosions proof connection compartment. 42226-EN-151030 VEGADIF DF65D.UG*****Z/H***** (Electronics 4 … 20 mA, 4 … 20 mA/HART) Power supply and signal circuit: (terU = 18 … 36 V DC (20 … 36 V DC with lighted indicating minals 1[+], 2[-] in the explosion proof and adjustment module) connection compartment) Um = 253 V VEGADIF DF65.UG*****P/F***** (Electronics Profibus PA, Foundation Fieldbus) Power supply and signal circuit: (terU = 12 … 32 V DC minals 1[+], 2[-] in the explosion proof Um = 253 V connection compartment) Intrinsically safe circuits The intrinscially safe cicuits are connected to terminals in the intrinsically safe connection compartVEGADIF DF65.UG*****Z/H/P/F***** 3 ment. VEGADIF DF65.UG*****Z/H/P/F***** Circuit of the indicating and adjustment module: (spring contacts in the intrinsically safe connection compartment) In ignition protection type intrinsic safety Ex ia IIC Only for connection to the indicating and adjustment module PLICSCOM. The intrinsically safe circuits are not free-of-ground. The metallic parts of VEGADIF DF65.UG*****Z/H/P/F***** are electrically connected with the internal and external earth terminals. 4 Application conditions The max. permissible ambient temperatures depending on the temperature classes are specified in the following tables. VEGADIF DF65.UG*****Z/H***** (Electronics 4 … 20 mA, 4 … 20 mA/HART) If the differential pressure transmitters are used in explosion hazardous areas, that require apparatus of the category Div 1/Zone 0 (measuring sensor) and Div. 1/Zone 1 (electronics), the permissible temperature range in the area of the electronics/at the measuring sensor dependent on the temperature class has to be taken from the following table: Temperature class Ambient temperature range (electronics, Div. 1/Zone 1) Medium temperature range (measuring sensor, Div. 1/Zone 0) T6 -40 … +55 °C -20 … +60 °C T5 -40 … +60 °C -20 … +60 °C T4, T3, T2, T1 -40 … +60 °C -20 … +60 °C If the measuring sensors of the differential pressure transmitters are operated at higher medium temperatures as listed in the a.m. table, measures have to be taken, that the danger of ignition caused by these hot surfaces is excluded. The max. permissible temperature at the electronics/ housing must not exceed the values as mentioned in the a.m. table. If the differential pressure transmitters are used in explosion hazardous areas that require apparatus of the category Div. 1/Zone 1, the permissible temperature range in the area of the electronics/at the measuring sensor dependent on the temperature class has to be taken from the following table: Temperature class Ambient temperature range (electronics) Medium temperature range (measuring sensor) T6 -40 … +55 °C -40 … +73 °C T5 -40 … +60 °C -40 … +92 °C T4, T3, T2, T1 -40 … +60 °C -40 … +120 °C If the measuring sensors of the differential pressure transmitters are operated at higher medium temperatures as listed in the a.m. table, measures have to be taken, that the danger of ignition caused by these hot surfaces is excluded. The max. permissible temperature at the electronics/ housing must not exceed the values mentioned in the a.m. table. 4 VEGADIF DF65.UG*****Z/H/P/F***** 42226-EN-151030 VEGADIF DF65.UG*****P/F***** (Electronics Profibus PA, Foundation Fieldbus) If the differential pressure transmitters are used in explosion hazardous areas, that require apparatus of the category Div 1/Zone 0 (measuring sensor) and Div. 1/Zone 1 (electronics), the permissible temperature range in the area of the electronics/at the measuring sensor dependent on the temperature class has to be taken from the following table: Temperature class Ambient temperature range (electronics, Div. 1/Zone 1) Medium temperature range (measuring sensor, Div. 1/Zone 0) T6 -40 … +45 °C -20 … +60 °C T5 -40 … +60 °C -20 … +60 °C T4, T3, T2, T1 -40 … +60 °C -20 … +60 °C If the measuring sensors of the differential pressure transmitters are operated at higher medium temperatures as listed in the a.m. table, measures have to be taken, that the danger of ignition caused by these hot surfaces is excluded. The max. permissible temperature at the electronics/ housing must not exceed the values as mentioned in the a.m. table. If the differential pressure transmitters are used in explosion hazardous areas that require apparatus of the category Div. 1/Zone 1, the permissible temperature range in the area of the electronics/at the measuring sensor dependent on the temperature class has to be taken from the following table: Temperature class Ambient temperature range (electronics) Medium temperature range (measuring sensor) T6 -40 … +45 °C -40 … +77 °C T5 -40 … +60 °C -40 … +92 °C T4, T3, T2, T1 -40 … +60 °C -40 … +120 °C If the measuring sensors of the differential pressure transmitters are operated at higher medium temperatures as listed in the a.m. table, measures have to be taken, that the danger of ignition caused by these hot surfaces is excluded. The max. permissible temperature at the electronics/ housing must not exceed the values mentioned in the a.m. table. The permissible operating temperatures and pressures are stated in the manufacturer information. 5 Protection against static electricity The VEGADIF DF65.UG*****Z/H/P/F***** in versions with electrostatically chargeable plastic parts, such as e.g. metal housing with inspection window or connection cable with the separated version, have a caution label pointing out the safety measures that must be taken with regard to electrostatic charges during operation. Caution: Plastic parts! Danger of static charge! • • • Avoid friction No dry cleaning Do not mount in areas with flowing, non-conductive products 42226-EN-151030 6Grounding The explosion proof connection compartment of VEGADIF DF65.UG*****Z/H/P/F***** includes a safety barrier without galvanic separation. For safety reasons, the intrinsically safe circuit must be grounded. The external or internal ground connection terminal on the housing serves for this purpose, it has to be connected with the potential equalization of the explosion hazardous area. 7 Impact and friction sparks The VEGADIF DF65.UG*****Z/H/P/F***** in aluminium versions must be mounted in such a way that sparks from impact and friction between aluminium and steel (except stainless steel, if the presVEGADIF DF65.UG*****Z/H/P/F***** 5 ence of rust particles can be excluded) cannot occur. 8 Material resistance 9 Ignition protection type explosion proof proof enclosure The VEGADIF DF65.UG*****Z/H/P/F***** must only be used in media against which the materials of the wetted parts are sufficiently resistant. The terminals for connecting to the operating voltage, i.e. signal circuits, are integrated in the connection compartment according to protection type explosion proof enclosure "d". The gap between housing and cover is a flameproof gap. The explosion proof connection compartment is provided with a M20 x 1.5 or ½-14 NPT thread for connection to a certified "Conduit" system or for mounting of a certified explosion proof cable entry (only for zones applications). Cable entries of simple construction may not be used. When connecting to a "Conduit" system the appropriate seal facility must be located directly on the explosion proof connection compartment. Unused openings must be sealed accordingly. Before opening or in case of the lid of the explosion proof connection compartment is open (e. g. during connection or service work), make sure that either the supply line is voltage free or no explosive atmosphere is present. The flameproof terminal box of this equipment must be provided with cable entries and filter plugs resp. condits which are certified according to CAN/CSA E 60079-0: 02 and CAN/CSA E 60079-1: 07. The connection cables, the cable entries and filter plugs resp. the conduits have to be suitable for the lowest ambient temperature. When wiring the connection line to the explosion proof connection compartment, it must be sufficiently secured against damage. The cover of the explosion proof connection compartment must be screwed in completely before commissioning and secured by screwing out the lid locking screw all the way to the stop. The cover of the explosion proof connection compartment with the caution label "Do not … is present" and the cover of the intrinsically safe connection compartment without caution label must not be exchanged. The covers must be mounted on the corresponding connection compartments. 42226-EN-151030 6 VEGADIF DF65.UG*****Z/H/P/F***** Double chamber housing with explosion proof connection compartment 1 2 3 2 1 2 3 4 Intrinsically safe connection compartment with electronics module Locking screw of the cover Explosion proof connection compartment with integrated barrier 10Notes 1. The Intrinsic Safety Entity concept allows the interconnection of two Intrinsically safe devices FM Approved and CSA Certified entity parameters not specifically examined in combination as a system when:Uo or Voc or Vt < Vmax, Io or Isc or It < Imax, Ca or Co > Ci + Ccable, La or Lo > Li + Lcable, Po < Pi. 2. For Division 2 Installations, the Sensor shall be installed in accordance with the National Electrical Code ® (ANSI/NFPA 70) or Canadian Electrical Code, CSA C22.1 Part 1 Appendix F for division 2 wiring methods. 3. Dust-tight conduit seal shall be used when installed in Class II and Class III environments. 4. For Division 1 installations, Control equipment shall not use or generate more than 250 Vrms or Vdc. 5. Division 1 installations should be in accordance with ANSI/ISA RP12.06.01"Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations" and the National Electrical Code ® (ANSI/ NFPA 70) or Canadian Electrical Code. 6. For Division 1 Installations, the terminal marked sign "earth" shall be grounded per ANSI/NFPA 70 article 504.50 or CSA C22.1 Part 1 Appendix F F3.2.2 and the Field Device wiring shall be segregated from the supply wiring. 7. For Division 2 Installations, the Field Device shall be installed in accordance with the National Electrical Code ® (ANSI/NFPA 70) or Canadian Electrical Code, CSA C22.1 Part 1 Appendix F for Division 2 wiring methods including Nonincendive Field Wiring when using the parameters shown. 42226-EN-151030 8. For Division 1 Installations the configuration of Field Device must be FM Approved/CSA Certified under Entity Concept. 9. The Field Device manufacturer's installation drawing shall be followed when installing this equipment. 10. No revision to drawing without prior Approval by FM Approvals and CSA International. 11. Division 1 Installation requirements must be complied with if one or more of the following are located in a Division 1 hazardous location: Sensor, Probe or Field Device. 12. Warning- Substitution of components may impair suitability for hazardous locations. VEGADIF DF65.UG*****Z/H/P/F***** 7 13. Do not open when an explosive atmosphere is present. 42226-EN-151030 8 VEGADIF DF65.UG*****Z/H/P/F***** Installation Diagram 42226-EN-151030 11 VEGADIF DF65.UG*****Z/H/P/F***** 9 42226-EN-151030 10 VEGADIF DF65.UG*****Z/H/P/F***** 42226-EN-151030 Notes VEGADIF DF65.UG*****Z/H/P/F***** 11 All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice © VEGA Grieshaber KG, Schiltach/Germany 2015 VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: [email protected] www.vega.com 42226-EN-151030 Printing date:
Benzer belgeler
Safety instructions - VEGADIF DF65.UF*****Z/H/P/F
The maximum output current Io for any type of power supply shall not exceed 380 mA and the maximum output power Po shall not exceed 5.32 W.
maximum output power Po shall not exceed 5.32 W.The power...