atex sensors catalogue
Transkript
atex sensors catalogue
Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 1 AT E X SENSORS CATALOGUE BDC ELECTRONIC S.r.l.was formed in 1970. Being the first in Italy to produce proximity sensors, it has gained in its business a lot of experience, thanks to its abilities to develop products to fulfil the market requirements. The extremely flexible company organization is able to satisfy customer's needs, assuring a high quality and reliable production, appreciated all over the world. Research and development is continuously working in order to offer solution to all kinds of problems and to find new applications. All the products are engineered to perform even in the arduous and most difficult conditions. The use of a quality system, certified according to standard ISO 9001:2008, affords the best care and precision in the fulfillment of all the realization stages: from the engineering to the production, through a manufacturing process with high levels of automation together with rigorous testings on each product. Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 2 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 3 BDC ELECTRONIC has obtained the ATEX notification of the production quality system and the ATEX certification according to the directive 94/9/EC for equipment intended for use in potentially explosive atmosphere. Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 5 PROXIMITY SENSORS TOTAL QUALITY FOR TOTAL PRECISION INTERNAL TEST LABORATORY SURFACE MOUNTING TECHNOLOGY (SMT) All the BDC ELECTRONIC products are tested with the most sophisticated high technology equipment to ensure conformity with the relevant of all the standards. The production process is based on the use of high technology machinery which allows the highest control levels for the quality of the finished product. All stages are built with the maximum accuracy to make the finished product attain the highest standards of functional reliability. Completely automated processes for every stage ensure the creation of a product made to satisfy any requirement. WINDING MACHINE RESIN DISPENSING MACHINE Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 1 CONTENTS ATEX SENSORS General informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-1 INDUCTIVE ATEX SENSORS How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-3 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) (DC…A) * Cable output - diameters 4 - 5 - 6,5 - 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable output - diameters 12 - 18 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable output - diameters 30 - 45 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable output with LED - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable output with LED - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . Connector output M12 x1 - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connector output M12 x1 - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . Connector output M12 x1 with LED - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . Connector output M12 x1 with LED - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . For high temperatures (- 20°÷ + 110°C) - Cable output - diameters 6,5 - 8 mm . . . . For high temperatures (- 20°÷ + 110°C) - Cable output - diameters 12-18-30-45 mm . . . . . . . . . . . AMPLIFIED IN d.c. - Atex Certified II 1GD for zone 0;20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-5 page A-6 page A-7 page A-8 page A-9 pageA-10 pageA-11 pageA-12 pageA-13 pageA-14 pageA-15 (DCA…MA) Cable output - Associated apparatus not required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-16 AMPLIFIED IN d.c. - Atex Certified II 2GD for zone 1;21 (DCA…MB) Cable output - Associated apparatus not required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-17 AMPLIFIED IN d.c. - Atex Certified II 3GD for zone 2;22 • CENELEC STANDARD Cable output - diameters 6,5 - 8 mm . . . . . . . . . . . . . . . . Cable output - diameter 12 mm . . . . . . . . . . . . . . . . . . . Cable output - diameters 18 - 30 - 45 mm . . . . . . . . . . . . Connector output M12 x1 - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (DCA…3GD) ........... ........... ........... ........... . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-18 pageA-19 pageA-20 pageA-21 • SHORT SERIES (DSA…3GD) Cable output - diameters 6,5 - 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-22 Connector output M12 x1 - diameters 6,5 - 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-23 • EXTENDED SENSING DISTANCE (DCE…3GD) Cable output - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-24 Connector output M12 x1 - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-25 • SHORT SERIES WITH EXTENDED SENSING DISTANCE (DSE…3GD) Cable output - diameters 6,5 - 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-26 Connector output M12 x1 - diameters 8 - 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-27 • EXTENDED TEMPERATURE RANGE (-20°÷+ 80°C) Cable output with LED - diameters 6,5-8 mm . . . . . . . . . . . . . Cable output with LED - diameter 12 mm . . . . . . . . . . . . . . . . Cable output with LED - diameters 18-30-45 mm . . . . . . . . . . Connector output M12 x1 with LED - diameters 8-12-18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (DCA…KST3GD) .............. .............. .............. .............. . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-28 pageA-29 pageA-30 pageA-31 • FOR HIGH TEMPERATURES (-20°÷+ 100°C) Cable output with LED - diameters 6,5-8 mm . . . . . . . . . . . . . Cable output with LED - diameter 12 mm . . . . . . . . . . . . . . . . Cable output with LED - diameters 18-30-45 mm . . . . . . . . . . Connector output M12 x1 with LED - diameters 8-12-18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (DCA…KSTB3GD) ............... ............... ............... ............... . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-32 pageA-33 pageA-34 pageA-35 (*) = to be used coupled with associated apparatus for Atex sensors (section E) Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 2 CONTENTS CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. + a.c. - Atex Certified II 3GD for zone 2;22 (AXM…3GD) Cable output - diameters 12-18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-36 ANALOGUE LINEAR OUTPUT - Atex Certified II 1GD for zone 0;20 ( ) (DCL…A) * Cable output - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-37 Connector output M12 x1 - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-38 CYLINDRICAL INDUCTIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) (DC…P/...A) * Cable output with LED - diameter 8 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page A-39 Cable output with LED - diameters 12 - 18 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page A-40 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) Type Type Type Type Type Type Z - Cable output . . . . . . . . . . . . . . . . . . T - Cable output . . . . . . . . . . . . . . . . . . X and Y - Cable output . . . . . . . . . . . . . . P - 5 Position head - Terminal block output 80 - Cable and connector output M12 x1 R - Cable and connector output M12 x1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . * . . . . . . . . . . . . AMPLIFIED IN d.c. - Atex Certified II 3GD for zone 2;22 (DC…/…A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-41 pageA-42 pageA-43 pageA-44 pageA-45 pageA-46 (DCA…3GD) Type Z - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-47 Type T - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-48 Type X and Y - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-49 SLOT INDUCTIVE ATEX SENSORS NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) * (DF…/…A) Cable output - Slot width 3,5 - 5 - 6 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-50 Cable output - Slot width 15 - 30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pageA-51 (*) = to be used coupled with associated apparatus for Atex sensors (section E) Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 3 CONTENTS ATEX CAPACITIVE SENSORS General informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-1 How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-1 CYLINDRICAL CAPACITIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) (NKS…/…A) * Cable output - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-3 Connector output M12 x1 - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-4 CYLINDRICAL CAPACITIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES - Atex Certified II 1GD for zone 0;20 ( ) (NKS…P/…A) * Cable output - diameters 18-30 mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page B-5 ATEX MAGNETIC SENSORS General informations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-1 How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-1 CYLINDRICAL MAGNETIC ATEX SENSORS IN METAL HOUSING WITH REED CONTACT - Atex Certified II 1GD for zone 0;20 Cable output - Associated apparatus not required . . . . . . . . . . . . . . . . . . . . . . . .(BMS…/…MA) . . . . . . . page C-3 Cable output - NAMUR output ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(BMSN…/…A) . . . . . . . page C-4 * RECTANGULAR MAGNETIC ATEX SENSORS WITH REED CONTACT - Atex Certified II 1GD for zone 0;20 ( ) * For pneumatic cylinders with T slot - Cable output . . . . . . . . . . . . . . . . . . . . . . . . . .(BMS…/…A) For pneumatic cylinders with T slot - Cable output - NAMUR output . . . . . . . . . . . .(BMSN…/…A) Type Z and W - Cable output . . . . . . . . . . . . . . . . . . . . . . . . .(BMSZ…/…A and BMSW/…A) Type Z and W - Cable output - NAMUR output . . . . . . . . . . .(BMSNZ…/…A and BMSBW/…A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page page page page C-5 C-6 C-7 C-8 MAGNETS Magnets for sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page C-9 ATEX SPEED SENSORS How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page D-1 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Atex Certified II 3GD for zone 2;22 3-wire in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (DSD…/…3GD) . . . . . . . . page D-3 3-wire in a.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (ASD…/…3GD) . . . . . . . page D-5 (*) = to be used coupled with associated apparatus for Atex sensors (section E) Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina 4 CONTENTS AMPLIFIERS AND REPEATERS FOR ATEX SENSORS General informations - How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-1 FOR NAMUR INPUTS OR CONTACTS Supply voltage 24 Vdc (D103xx) Relay output for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-3 Transistor output for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-5 Supply voltage 115 ÷ 230 Vac (D113xx) Relay output for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page E-7 FOR ANALOGIC INPUTS Input 4 ÷ 20 mA - Output 4 ÷ 20 mA for DIN Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(D1010) . . . . . . page E-9 CONNECTORS FOR ATEX SENSORS MALE CONNECTORS PREASSEMBLED WITH SENSORS General informations - How to compose the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page F-1 CONNECTORS MOULDED WITH CABLE How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page G-1 Female ATEX Connectors M12x1 Straight in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C10…) . . . . . . .page G-3 Right angled in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C8B…) . . . . . . .page G-4 Male ATEX Connectors M12x1 Straight in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C9…) . . . . . . .page G-5 Right angled in d.c. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (C9B…) . . . . . . .page G-6 MOULDED CONNECTING CABLES FOR ATEX SENSORS How to interprete the ordering references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page H-1 Male M12x1 straight - Female M12x1 . . . . . . . . . . . . . . . . . . . . . . (C9/C10/… - C9/C8B/…) . . . . . . . page H-3 Male M12x1 right angled - Female M12x1 . . . . . . . . . . . . . . . . . (C9B/C10/… - C9B/C8B/…) . . . . . . . page H-4 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-1 GENERAL INFORMATIONS ATEX SENSORS This catalogue is complementary to the BDC General Catalogue. Please refer to General informations, installation and storage instructions on section "General information" of the General Catalogue. ATEX installation instructions are available on website www.bdcelectronic.com. The ATEX sensors meet the requirements of 94/9/EC directive and are certified by IMQ for use in potentially explosive atmospheres. The applied harmonized standards are listed on the product pages. It's very important to choose the category of the device according to the classification of the potentially explosive area: GASES, VAPOURS OR MISTS Zone 0: continuous danger An area in which an explosive gases atmosphere is continuously present or present for long periods. Zone 1: potential danger An area in which an explosive gases atmosphere is likely to occur in normal operation. Zone 2: minimum danger An area in which an explosive gases atmosphere is not likely to occur in normal operation and if it occurs it will exist only for a short time. DUSTS Zone 20: continuous danger An area in which an explosive dust atmosphere of is continuously present or present for long periods. Zone 21: potential danger An area in which an explosive dust atmosphere is likely to occur in normal operation. Zone 22: minimum danger An area in which an explosive dust atmosphere is not likely to occur in normal operation and if it occurs it will exist only for a short time. BDC products include sensors for category 1GD, 2GD and 3GD. Sensors for category 1GD are suitable for application in zone 0-20, 1-21, and 2-22. They are of two types: - Amplified with protection by encapsulation "m", associated apparatus is not required. - NAMUR with protection by intrinsic safety "ia", require associated apparatus. The sensor with protection by intrinsic safety "ia" require associated apparatus certified. To find the appropriate associated apparatus contact our technical department. The final user must use the products according with the instruction manuals supplied. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-1 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-3 HOW TO INTERPRETE THE ORDERING REFERENCES INDUCTIVE ATEX SENSORS AXM DC DCA DCE DCL DF DSA DSE = cylindrical amplified a.c. + d.c. 2-wire 10 ÷ 50 V = cylindrical NOT amplified d.c. NAMUR series = cylindrical amplified d.c. = cylindrical extended sensing distance d.c. series = cylindrical analogue linear output = slot sensors NOT amplified d.c. NAMUR series = cylindrical amplified d.c. SHORT series = cylindrical amplified extended sensing distance d.c. SHORT series Diameter of cylindrical sensor or slot width for slot types. For other types, change the number with the following: DC 18 P/ 80 P R T X Y Z = diameter 80 mm = rectangular plastic 5 positions head 40 x 40 x 112 = rectangular plastic with adjustable sensing distance 100 x 111 x 30 = rectangular plastic 25 x 40 x 12 = rectangular plastic 25 x 50 x 10 = rectangular plastic 30 x 50 x 15 = rectangular plastic 16 x 28 x 10 P = plastic housing sensor 4 5 = flush mounting = non flush mounting 4 6 0 9 KS A 3 6 7 8 A H = with connector M12 x 1 = standard type cable output = cable output with sheath support = with gland = body length 50 mm completely threaded = male connector wired to the sensor (see page F-1) 0 1 2 C = NO output (models with LED) or NC (models without LED) = NC (normally closed output) = NO + NC (complementary outputs) = NC (output normally closed on pin 2 of connector) 0 8 9 = NAMUR series 2-wire = NPN = PNP L K S T = smooth body = protection against short circuit and overload = LED output status = high temperature version A MA MB 3GD = category 1G - 1D - NAMUR Series - Mode of protection “ia”: to be used with associated apparatus = category 1G - 1D - Amplified Series - Mode of protection “m” = category 2G - 2D - Amplified Series - Mode of protection “m” = category 3G - 3D - Amplified Series - Mode of protection “n” and “t” -5 PR Cable length (if required different than standard 2m) For Polyurethane cable add PR BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-3 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-5 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES - diameters 4 - 5 - 6,5 - 8 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing A L5 L2 L1 d Housing B L5 L2 L1 d Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 ∆I with metal Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,14 mm2 in diameters 4 and 5 mm 0,35 mm2 in diameter 6,5 • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 011 X • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 D (mm) Sn (switching point) Diameter Nut ∆d Size Thickness mm Max tightening torque Nm M5 x 0,5 M8 x 1 SW7 SW13 2,5 4 2 10 Materials: • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V;O.R. • Housing: stainless steel • Sensing face: plastic Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Max switching frequency (f) Nominal sensing distance ( Sn ) ± 10% mm mm mm mm mm mm KHz mm L2 L3 L4 L5 Body diameter (d) mm L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I brown blue Rx A • - 20 - - 20 3 4 5 0,8 DC4/4600LA B • - 20 - - 20 3 M5 x 0,5 5 0,8 DC5/4700A A A • • 5 25 20 - - 25 25 4 4 6,5 6,5 5 3 1,5 2,5 DC6,5/4700LA DC6,5/5700LA B B • • 5 25 20 - - 25 25 4 4 M8 x 1 M8 x 1 5 3 1,5 2,5 DC8/4700A DC8/5700A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-5 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-6 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES diameters 12 - 18 mm • ATEX certified II 1GD for zone 0;20 • Cable output Housing B L5 L2 L1 d Housing F-1 L5 L1 L2 L4 d Typical curve I(mA) 4 Technical data: without metal • Supply voltage according NAMUR: • Max ripple: • Consumption at 8,2 V with Rx = 1000 Ω with metal: without metal: • Temperature range: • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): • Degree of protection according EN60529: • Cable conductor cross section: 3 1,75mA 2 1,55mA 1 0 ∆I with metal D (mm) Sn (switching point) Diameter Nut ∆d M12 x 1 Size Thickness mm Max tightening torque Nm M18 x 1 SW17 SW24 4 4 15 35 7,7 ÷ 9 Vdc 10% ≤ 1 mA ≥ 3 mA - 20° ÷ + 60°C ± 10% 2% IP67 0,35 mm2 in diameter 12 mm 0,75 mm2 in diameter 18 mm • Marking: Materials: • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V;O.R. • Housing: nickel plated brass • Sensing face: plastic • • • • II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 010 Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Nominal sensing distance ( Sn ) ± 10% mm mm mm mm mm KHz mm • • • • 7 7 30 30 23 23 - 20 20 30 50 30 50 4 4 4 4 M12 x 1 M12 x 1 M12 x 1 M12 x 1 5 5 1 1 2 2 4 4 DC12/4600A DC12/4700A DC12/5600A DC12/5700A B F -1 B F -1 • • • • 10 10 30 30 20 20 - 20 20 30 50 30 50 5 5 5 5 M18 x 1 M18 x 1 M18 x 1 M18 x 1 1 1 0,5 0,5 5 5 8 8 DC18/4600A DC18/4700A DC18/5600A DC18/5700A L2 L3 L4 L5 Body diameter (d) mm L1 Cable diameter Max switching frequency (f) B F -1 B F -1 A-6 mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I brown blue Rx + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-7 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES diameters 30 - 45 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-9 L5 L1 L2 d Housing F-2 L5 L1 L2 L4 d Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 ∆I with metal D (mm) Sn (switching point) Diameter Nut Technical data: ∆d Size Thickness mm Max tightening torque Nm M30 x 1,5 M45 x 1,5 SW36 SW55 5 5 80 70 Materials: • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V;O.R. • Housing: nickel plated brass • Sensing face: plastic • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,75 mm2 • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) B-9 • • • mm mm mm mm mm mm KHz mm 15 15 35 35 20 20 - 20 20 35 55 35 55 5 5 5 5 M30 x 1,5 M30 x 1,5 M30 x 1,5 M30 x 1,5 0,3 0,3 0,2 0,2 10 10 15 15 DC30/4600A DC30/4700A DC30/5600A DC30/5700A - 35 - - 35 5 M45 x 1,5 0,3 20 DC45/4700A L2 L3 L4 L5 Body diameter (d) Nominal sensing distance ( Sn ) ± 10% • • Max switching frequency (f) B-9 F-2 B-9 F-2 mm L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I brown blue Rx + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-7 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-8 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES WITH LED diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Cable output Housing B L1 L5 L2 d LED Diameter M8 x 1 Size Nut SW13 Thickness mm 4 Max tightening torque Nm 10 Materials: • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V; O.R. • Housing: stainless steel • Sensing face: plastic General features: With this new series of sensors it’s possible to drive specific inputs for NAMUR sensors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally triggered and monitored by LED. Technical data: • • • • • • • • • • • • • • • • • • • • Working voltage: 7,7 ÷ 9 Vdc Max ripple: 10% ≤ 1 mA Off-state current (Ir): 2 mA Minimum operational current (Im): 10 mA Rated operational current (Ie): < 6,5 V Voltage drop (Ud) with load 10 mA: <5V Voltage drop (Ud) with load 8 mA: Temperature range: - 20° ÷ +60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,35 mm2 Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 011 X Protected against any wrong connection Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) B B A-8 • • L4 L5 Nominal sensing distance (Sn) ±10% L3 Max switching frequency ( f ) L2 Body diameter (d) L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals mm mm mm mm mm mm mm KHz mm 5 30 25 - - 30 30 4 4 M8 x 1 M8 x 1 3 2 1,5 2,5 ORDERING REFERENCES NO I NC brown blue + Rx DC8/4600SA DC8/5600SA --- I brown blue + Rx --- DC8/4610SA DC8/5610SA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-9 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES WITH LED diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-4 L5 L2 L1 d LED Housing B-5 L5 L1 L2 LED General features: d With this new series of sensors it’s possible to drive specific inputs for NAMUR sensors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally triggered and monitored by LED. Housing B-9 L5 L1 Technical data: L2 LED d Diameter Nut Size M12 x 1 M18 x 1 M30 x 1,5 SW17 SW24 SW36 4 4 5 15 35 80 Thickness mm Max tightening torque Nm • • • • • • • • • • • • • • • Materials: • Cable: 2 m PVC CEI 20-22 II; 90°C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic • • • • • • Working voltage: Max ripple: Off-state current (Ir): Minimum operational current (Im): Rated operational current (Ie): Voltage drop (Ud) with load 10 mA: Voltage drop (Ud) with load 8 mA: Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: 7,7 ÷ 9 Vdc 10% ≤ 1 mA 2 mA 10 mA < 6,5 V <5V - 20° ÷ +60°C ± 10% 2% 10% IP67 yellow LED 0,35 mm2 in diameter 12 mm 0,75 mm2 in diameters 18 and 30 mm Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 010 Protected against short-circuit and overload Protected against any wrong connection Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) B-4 B-4 • B-5 B-5 • B-9 B-9 • L4 L5 Nominal sensing distance (Sn) ±10% L3 Max switching frequency ( f ) L2 Body diameter (d) L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES NO I NC brown blue + Rx I brown blue --- + Rx --- mm mm mm mm mm mm mm KHz mm • 7 30 23 - - 30 30 4 4 M12 x 1 M12 x 1 2 1 2 4 DC12/4600KSA DC12/5600KSA DC12/4610KSA DC12/5610KSA • 10 30 20 - - 30 30 5 5 M18 x 1 M18 x 1 0,8 0,6 5 8 DC18/4600KSA DC18/5600KSA DC18/4610KSA DC18/5610KSA • 15 35 20 - - 35 35 5 5 M30 x 1,5 M30 x 1,5 0,8 0,4 10 15 DC30/4600KSA DC30/5600KSA DC30/4610KSA DC30/5610KSA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-9 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-10 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12x1 Housing I L1 L2 L5 L3 L4 d 2 M12 x 1 3 1 4 Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 ∆I with metal ∆d Diameter Nut D (mm) Sn (switching point) M8 x 1 Size SW13 Thickness mm 4 Max tightening torque Nm 10 Materials: • Housing: • Sensing face: stainless steel plastic Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 011 X • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) I I A-10 • • L4 L5 Nominal sensing distance ( Sn ) ± 10% L3 Max switching frequency (f) L2 Body diameter (d) L1 Female connector (see page G - 1) Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals mm mm mm mm mm n° mm KHz mm 5 26 21 13 13 8 8 47 47 8B - 10 8B - 10 M8 x 1 M8 x 1 4 3 1,5 2,5 ORDERING REFERENCES I 1 brown 2 blue Rx + --- DC8/4300A DC8/5300A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-11 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12x1• Housing I-9 L1 L5 L2 L3 L4 2 d M12 x 1 3 1 4 Housing I-1 L1 L5 L2 L3 L4 2 d M12 x 1 3 1 4 Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 Diameter Nut Size ∆I with metal D (mm) Sn (switching point) M12 x 1 M18 x 1 M30 x 1,5 SW17 SW24 SW36 4 4 5 15 35 80 Thickness mm Max tightening torque Nm Technical data: ∆d Materials: • Housing: • Sensing face: nickel plated brass plastic • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) I-9 I-9 • I-1 I-1 • I-1 I-1 • L4 L5 Nominal sensing distance ( Sn ) ± 10% L3 Max switching frequency (f) L2 Body diameter (d) L1 Female connector (see page G - 1) Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I 1 brown 2 blue Rx mm mm mm mm mm n° mm KHz mm • 7 30 23 10 10 8 8 48 48 8B - 10 8B - 10 M12 x 1 M12 x 1 2 1 2 4 DC12/4300A DC12/5300A • 10 27 17 15 15 8 8 48 48 8B - 10 8B - 10 M18 x 1 M18 x 1 0,8 0,6 5 8 DC18/4300A DC18/5300A • 15 25 25 17 17 8 8 50 65 8B - 10 8B - 10 M30 x 1,5 M30 x 1,5 0,8 0,4 10 15 DC30/4300A DC30/5300A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] + --- A-11 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-12 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES WITH LED diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12 x 1 Housing I L1 L2 L5 L3 L4 d 2 M12 x 1 3 4 x LED Diameter Nut 1 4 M8 x 1 Size SW13 Thickness mm 4 Max tightening torque Nm 10 Materials: • Housing: • Sensing face: stainless steel plastic General features: With this new series of sensors it’s possible to drive specific inputs for NAMUR sensors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally triggered and monitored by LED. Technical data: • • • • • • • • • • • • • • • • • • • Working voltage: 7,7 ÷ 9 Vdc Max ripple: 10% ≤ 1 mA Off-state current (Ir): 2 mA Minimum operational current (Im): 10 mA Rated operational current (Ie): < 6,5 V Voltage drop (Ud) with load 10 mA: <5V Voltage drop (Ud) with load 8 mA: Temperature range: - 20° ÷ +60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 011 X Protected against any wrong connection Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) I I A-12 • • L4 L5 Nominal sensing distance ( Sn ) ± 10% L3 Max switching frequency (f) L2 Body diameter (d) L1 Female connector (see page G - 1) Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals mm mm mm mm mm n° mm KHz mm 5 26 21 13 13 8 8 47 47 8B - 10 8B - 10 M8 x 1 M8 x 1 3 2 1,5 2,5 ORDERING REFERENCES I NO 1 brown 4 blue + Rx DC8/4300SA DC8/5300SA --- I NC 1 brown 2 blue Rx + --- DC8/4310SA DC8/5310SA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-13 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES WITH LED diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Connector output M12 x 1 • Housing I-9 L1 L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-1 L1 L5 L2 L3 L4 2 d M12 x 1 Nut Size With this new series of sensors it’s possible to drive specific inputs for NAMUR sensors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally triggered and monitored by LED. M12 x 1 M18 x 1 M30 x 1,5 SW17 SW24 SW36 4 4 5 15 35 80 Thickness mm Max tightening torque Nm General features: 1 4 4 x LED Diameter 3 Materials: • Housing: • Sensing face: nickel plated brass plastic Technical data: • • • • • • • • • • • • • • • • • • • • Working voltage: 7,7 ÷ 9 Vdc Max ripple: 10% ≤ 1 mA Off-state current (Ir): 2 mA Minimum operational current (Im): 10 mA Rated operational current (Ie): < 6,5 V Voltage drop (Ud) with load 10 mA: <5V Voltage drop (Ud) with load 8 mA: Temperature range: - 20° ÷ +60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 010 Protected against short-circuit and overload Protected against any wrong connection Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) I-9 I-9 • I-1 I-1 • I-1 I-1 • Nominal sensing distance ( Sn ) ± 10% Body diameter (d) mm mm mm mm n° mm KHz mm • 7 30 23 10 10 8 8 48 48 8B - 10 8B - 10 M12 x 1 M12 x 1 2 1 2 4 DC12/4300KSA DC12/5300KSA DC12/4310KSA DC12/5310KSA • 10 27 17 15 15 8 8 49 49 8B - 10 8B - 10 M18 x 1 M18 x 1 0,8 0,6 5 8 DC18/4300KSA DC18/5300KSA DC18/4310KSA DC18/5310KSA • 15 25 25 17 17 8 8 50 65 8B - 10 8B - 10 M30 x 1,5 M30 x 1,5 0,8 0,4 10 15 DC30/4300KSA DC30/5300KSA DC30/4310KSA DC30/5310KSA L1 L2 L3 L4 L5 Max switching frequency (f) Female connector (see page G - 1) mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I NO 1 brown 4 blue I + Rx NC 1 brown 2 blue --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Rx + --- A-13 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-14 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES For high temperatures Ø 6,5 - 8 mm (-20° ÷ + 110° C) • ATEX certified II 1GD for zone 0;20 • Cable output Housing A L5 L2 L1 d Housing B L5 L2 L1 d Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 ∆I with metal ∆d D (mm) Sn (switching point) Diameter Nut Technical data: M8 x 1 Size SW13 Thickness mm 4 Max tightening torque Nm 10 Materials: • Cable: • Housing: • Sensing face: 2 m thermoplastic 140°C; 300 V; O.R. stainless steel plastic • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 110°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,35 mm2 in diameters 6,5 ÷ 12 mm 0,75 mm2 in diameters 18 ÷ 45 mm • Marking: II 1D Ex iaD 20 T 130°C II 1G Ex ia IIC T4 • Certified IMQ 08 ATEX 011 X • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Max switching frequency (f) Nominal sensing distance ( Sn ) ± 10% mm mm mm mm mm mm KHz mm L2 L3 L4 L5 Body diameter (d) mm L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I brown blue Rx A • - 25 - - 25 4 6,5 5 1,5 DC6,5/4600LTA B • - 25 - - 25 4 M8 x 1 5 1,5 DC8/4600TA A-14 + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-15 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES For high temperatures Ø 12-18-30-45 mm (-20°÷+110°C) • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B L5 L2 L1 d Housing B-1 L5 L1 L2 d Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 Diameter Nut Size Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: • Sensing face: ∆I with metal Technical data: ∆d D (mm) Sn (switching point) M12 x 1 M18 x 1 M30 x 1,5 M45 x 1,5 SW17 SW24 SW36 SW55 4 4 5 5 15 35 80 70 2 m thermoplastic 140°C; 300 V; O.R. nickel plated brass plastic • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 110°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,35 mm2 in diameters 6,5 ÷ 12 mm 0,75 mm2 in diameters 18 ÷ 45 mm • Marking: II 1D Ex iaD 20 T 130°C II 1G Ex ia IIC T4 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Max switching frequency (f) Nominal sensing distance ( Sn ) ± 10% mm mm mm mm mm mm KHz mm L2 L3 L4 L5 Body diameter (d) mm L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I brown blue Rx B • - 30 - - 30 4 M12 x 1 5 2 DC12/4600TA B-1 • - 30 - - 30 5 M18 x 1 1 5 DC18/4600TA B-1 • - 35 - - 35 5 M30 x 1,5 0,3 10 DC30/4600TA B-1 • - 35 - - 35 5 M45 x 1,5 0,3 20 DC45/4600TA + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-15 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-16 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire • ATEX certified II 1GD for zone 0;20 • Associated apparatus not required - Cable output Housing J-1 L5 L2 LED d Housing G L5 L2 L3 LED d Diameter Nut Size Thickness mm Max tightening torque Nm M18 x 1 M30 x 1,5 SW24 SW36 4 5 35 80 Materials: • Cable: • Housing: • Sensing face: 2 m PVC; 90°C; 300 V; O.R. nickel plated brass plastic Technical data: • • • • • • • • • • Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max storage temperature: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: 7 ÷ 30 Vdc 10% ≤ 10 mA < 1,5 V - 20° ÷ + 60°C + 85°C ± 10% 4% 10% IP67 for diameter 30 mm IP68 for diameter 18 mm yellow LED 0,50 mm2 • Switch status indicator: • Cable conductor cross section: • Marking: II 1D Ex maD 20 T80°C II 1G Ex ma II T6 • Certified IMQ 08 ATEX 002 X • Protected against short-circuit and overload • Protected against any wrong connection • Suppression of initial false impulse • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60079-0/EN60079-18/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 mm mm mm mm mm mm KHz Nominal sensing distance (Sn) ±10% L5 Rated operational current ( Ie ) L4 Max switching frequency ( f ) L3 Body diameter (d) L2 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals mA mm ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue + --- J-1 • 50 - - 50 5 M18 x 1 0,3 400 5 DCA18/4A09KSJMA DCA18/4A19KSJMA G • 50 10 - 60 6 M30x1,5 0,1 400 10 DCA30/4609KSMA DCA30/4619KSMA NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KSJMA) NO I A-16 brown black blue NC + --- I brown black blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-17 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire • ATEX certified II 2GD for zone 1;21 • Associated apparatus not required - Cable output • Housing B-3 L5 L2 L3 d LED Housing J-1 L5 L2 LED d Housing G L5 L2 L3 LED Technical data: d Diameter Nut Size M12 x 1 M18 x 1 M30 x 1,5 SW17 SW24 SW36 4 4 5 15 35 80 Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: • Sensing face: • • • • • • • • • • 2 m PVC; 90°C; 300 V; O.R. nickel plated brass plastic • • • • • • • • • • Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max storage temperature: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: 7 ÷ 30 Vdc 10% ≤ 10 mA < 1,5 V - 20° ÷ + 60°C + 85°C ± 10% 2% 10% IP67 for diameters 12 and 30 mm IP68 for diameter 18 mm Switch status indicator: yellow LED Cable conductor cross section: 0,35 mm2 for diameter 12 mm 0,50 mm2 for diameter 18 mm 0,50 mm2 for diameter 30 mm Marking: II 2D Ex mbD 21 T80°C II 2G Ex mb II T6 Certified IMQ 08 ATEX 002 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-18/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 mm mm mm mm mm mm 43 50 50 7 10 - 50 50 60 4 5 6 M12 x 1 M18 x 1 M30x1,5 mA mm 0,8 200 0,3 400 0,1 400 2 5 10 Max switching frequency ( f ) L5 Body diameter (d) L4 Cable diameter L3 Nominal sensing distance (Sn) ±10% • • • L2 Rated operational current ( Ie ) B-3 J-1 G Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals KHz ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- DCA12/4609KSMB DCA18/4A09KSJMB DCA30/4609KSMB brown black blue + --- DCA12/4619KSMB DCA18/4A19KSJMB DCA30/4619KSMB NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KSMB) NO I brown black blue NC + --- I brown black blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] + --- A-17 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-18 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3 and 4-wire - diameters 6,5 - 8 mm • ATEX certified II 3GD for zone 2;22 • Cable output Housing A-3 L1 L5 L2 d LED Housing B-6 L5 L2 L1 L3 d LED Diameter Nut M8 x 1 Size SW13 Thickness mm 4 Max tightening torque Nm 10 Materials: • Cable: • Housing: • Sensing face: 2 m PVC; 90°C; 300 V; O.R. stainless steel plastic Technical data: • • • • • • • • • • • • • • • • • • Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: 7 ÷ 30 Vdc 10% ≤ 10 mA < 1,5 V - 25° ÷ + 60°C ± 10% 2% 10% IP67 yellow LED 0,15 mm2 in 4-wire versions 0,22 mm2 in 3-wire versions Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 A-3 A-3 • B-6 • B-6 • • Nominal sensing distance (Sn) ±10% L5 Rated operational current ( Ie ) L3 Max switching frequency ( f ) L2 Body diameter (d) L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals mA mm ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I brown black blue NO + NC + I brown black white blue + mm mm mm mm mm mm KHz 5 45 40 - 45 45 3,5 3,5 6,5 6,5 4 3 100 1,5 100 2,5 DCA6,5/4609LKS3GD DCA6,5/4619LKS3GD DCA6,5/4629LKS3GD DCA6,5/5609LKS3GD DCA6,5/5619LKS3GD DCA6,5/5629LKS3GD - 40 5 45 3,5 M8 x 1 4 100 1,5 DCA8/4609KS3GD DCA8/4619KS3GD DCA8/4629KS3GD 5 35 5 45 3,5 M8 x 1 3 100 2,5 DCA8/5609KS3GD DCA8/5619KS3GD DCA8/5629KS3GD --- --- --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA6,5/4608LKS3GD) NO I A-18 brown black blue NC + --- I brown black blue NO + NC + --- I brown black white blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-19 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire - diameter 12 mm • ATEX certified II 3GD for zone 2;22 • Cable output • Housing B-3 L1 L5 L2 L3 d LED Housing D L5 L1 L2 L4 L3 d LED Diameter Nut M12 x 1 Size SW17 Thickness mm 4 Max tightening torque Nm 15 Materials: • Cable: • Housing: • Sensing face: 2 m PVC; 90°C; 300 V; O.R. nickel plated brass plastic Technical data: • • • • • • • • • • • • • • • • • • Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: 5 ÷ 40 Vdc 10% ≤ 10 mA < 1,5 V - 25° ÷ + 60°C ± 10% 2% 10% IP67 yellow LED 0,35 mm2 in 3-wire versions 0,25 mm2 in 4-wire versions Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 B-3 D B-3 D • • • • L5 mm mm mm mm mm mm 7 7 43 50 36 43 7 10 7 10 20 20 50 80 50 80 4 4 4 4 mm KHz Nominal sensing distance (Sn) ±10% L4 Rated operational current ( Ie ) L3 Max switching frequency ( f ) L2 Body diameter (d) L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals mA mm M12 x 1 2 100 M12 x 1 2 100 M12 x 1 1,5 100 M12 x 1 1,5 100 2 2 4 4 ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- DCA12/4609KS3GD DCA12/4709KS3GD DCA12/5609KS3GD DCA12/5709KS3GD brown black blue NO + NC + I --- DCA12/4619KS3GD DCA12/4719KS3GD DCA12/5619KS3GD DCA12/5719KS3GD brown black white blue + --- DCA12/4629KS3GD DCA12/4729KS3GD DCA12/5629KS3GD DCA12/5729KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KS3GD) NO I brown black blue NC + --- I brown black blue NO + NC + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] brown black white blue + --- A-19 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-20 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire - diameters 18 - 30 - 45 mm • ATEX certified II 3GD for zone 2;22 • Cable output Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d Housing G-1 L5 L2 L3 d Technical data: LED Diameter Nut • Supply voltage (UB): M18 x 1 M30 x 1,5 M45 x 1,5 SW24 SW36 SW55 4 5 4 35 80 70 Size Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: • Sensing face: • • • • • • • • • • 2 m PVC; 90°C; 300 V; O.R. nickel plated brass plastic • • • • • • • diameter 18 mm: 5 ÷ 60 Vdc diameters 30 - 45 mm: 7 ÷ 60 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 2,2 V Voltage drop (Ud): Temperature range: - 25° ÷ + 60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,50 mm2 in 3-wire version diameter 18 mm 0,35 mm2 in 4-wire version diameter 18 mm 0,50 mm2 for diameters 30 and 45 mm Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Rated operational current ( Ie ) Nominal sensing distance (Sn) ±10% mm mm mm mm KHz mA mm B-2 B-2 • • 10 50 40 - - 50 50 5 5 M18 x 1 M18 x 1 1 1 200 200 5 8 DCA18/4A09KS3GD DCA18/4A19KS3GD DCA18/4A29KS3GD DCA18/5A09KS3GD DCA18/5A19KS3GD DCA18/5A29KS3GD G G • • 15 50 35 10 10 - 60 90 6 6 M30 x 1,5 0,8 200 M30 x 1,5 0,4 200 10 15 DCA30/4609KS3GD DCA30/4619KS3GD DCA30/4629KS3GD DCA30/5609KS3GD DCA30/5619KS3GD DCA30/5629KS3GD G-1 • 10 50 10 - 60 6 M45 x 1,5 0,15 200 20 DCA45/4609KS3GD DCA45/4619KS3GD DCA45/4629KS3GD L3 L4 L5 Max switching frequency ( f ) mm L2 Body diameter (d) mm L1 Cable diameter mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue NO + NC + I --- brown black white blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KS3GD) NO I A-20 brown black blue NC + --- I brown black blue NO + NC + --- I brown black white blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-21 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. • ATEX certified II 3GD for zone 2;22 • Connector output M12x1 • Housing I-11 L1 L2 L5 L3 L4 2 M12 x 1 d 3 4 x LED Housing I-7 L1 1 4 L5 L2 L3 L4 d 2 M12 x 1 3 4 x LED Housing I-12 L1 1 4 L5 L2 L3 L4 2 d M12 x 1 3 4 x LED Housing I-2 1 4 Technical data: • • • • • • • • • • • • L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Diameter Nut Size M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Thickness mm Max tightening torque Nm Materials: • Housing diameter 8 mm: • Housing diameters 12 ÷ 30 mm: • Sensing face: • • • • • • stainless steel nickel plated brass plastic Supply voltage (UB): see ordering references Max ripple: 10% 100 mA Rated operational current (Ie): ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 I - 11 I - 11 • I-7 I-7 • I - 12 I - 12 • I-2 I-2 • L5 (min V - max) KHz Nominal sensing distance (Sn) ±10% L4 Max switching frequency ( f ) L3 Supply voltage ( UB ) L2 Body diameter (d) L1 Female connector (see page G - 1) Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I NO + NC NC + I 1 brown 2 white 3 blue + I 1 brown 4 black 2 white 3 blue + mm mm mm mm mm n° mm • - 40 12 8 60 5 35 12 8 60 8B -10 8B -10 M8 x 1 M8 x 1 7 ÷ 30 7 ÷ 30 4 3 • - 43 15 8 66 7 36 15 8 66 8B -10 8B -10 M12 x 1 M12 x 1 5 ÷ 40 5 ÷ 40 2 1,5 2 4 DCA12/4309KS3GD DCA12/43C9KS3GD DCA12/4329KS3GD DCA12/5309KS3GD DCA12/53C9KS3GD DCA12/5329KS3GD • - 50 19 8 77 10 50 19 8 87 8B -10 8B -10 M18 x 1 M18 x 1 5 ÷ 60 5 ÷ 60 1 1 5 8 DCA18/4309KS3GD DCA18/43C9KS3GD DCA18/4329KS3GD DCA18/5309KS3GD DCA18/53C9KS3GD DCA18/5329KS3GD • - 65 17 8 90 15 50 17 8 90 8B -10 8B -10 M30x1,5 7 ÷ 60 M30x1,5 7 ÷ 60 0,8 0,4 mm 1 brown 4 black 3 blue --- 1,5 DCA8/4309KS3GD 2,5 DCA8/5309KS3GD --- DCA8/43C9KS3GD DCA8/53C9KS3GD --- DCA8/4329KS3GD DCA8/5329KS3GD 10 DCA30/4309KS3GD DCA30/43C9KS3GD DCA30/4329KS3GD 15 DCA30/5309KS3GD DCA30/53C9KS3GD DCA30/5329KS3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA8/4308KS3GD) NO I 1 brown 4 black 3 blue NO + NC NC + --- I 1 brown 2 white 3 blue + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] 1 brown 4 black 2 white 3 blue + --- A-21 Catalogo Atex 2013 Inglese_03 11-04-2013 9:52 Pagina A-22 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire - SHORT SERIES • ATEX certified II 3GD for zone 2;22 • Cable output Housing A L1 L5 L2 d LED Housing B L1 L5 L2 d LED Housing B-4 L1 L5 L2 d LED • • • • • • • • • • • LED d Diameter Nut Size Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: A A • B B • B-4 B-4 • B-5 B-5 • B-5 B-5 • L2 L3 L4 L5 Body diameter (d) L1 Cable diameter Flush mounting Non flush mounting Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. Housing diameters 6,5 and 8 mm: stainless steel Housing diameters 12 ÷ 30 mm: nickel plated brass Sensing face: plastic Housing • • • • • • • • • • • Use in hazardous area according to instruction manuals V (min - max) KHz Nominal sensing distance (Sn) ±10% L2 Rated operational current ( Ie ) L1 see ordering references 10% ≤ 10 mA ≤ 1,5 V - 25° ÷ + 60°C ± 10% 2% 10% IP67 yellow LED 0,22 mm2 in diameters 6,5 and 8 mm 0,35 mm2 in diameter 12 mm 0,50 mm2 in diameters 18 and 30 mm Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Max switching frequency ( f ) L5 Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: Supply voltage ( UB ) Housing B-5 Technical data: mA mm ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I brown black blue + mm mm mm mm mm mm mm • 5 30 25 - - 30 30 3,5 3,5 6,5 6,5 7 ÷ 30 7 ÷ 30 4 3 200 1,5 200 2,5 DSA6,5/4609LKS3GD DSA6,5/5609LKS3GD DSA6,5/4619LKS3GD DSA6,5/5619LKS3GD • 5 30 25 - - 30 30 3,5 3,5 M8 x 1 M8 x 1 7 ÷ 30 7 ÷ 30 4 3 200 1,5 200 2,5 DSA8/4609KS3GD DSA8/5609KS3GD DSA8/4619KS3GD DSA8/5619KS3GD • 7 30 23 - - 30 30 4 4 M12 x 1 M12 x 1 7 ÷ 30 7 ÷ 30 2 200 1,5 200 2 4 DSA12/4609KS3GD DSA12/5609KS3GD DSA12/4619KS3GD DSA12/5619KS3GD • 10 30 20 - - 30 30 5 5 M18 x 1 M18 x 1 5 ÷ 40 5 ÷ 40 0,8 200 0,6 200 5 8 DSA18/4609KS3GD DSA18/5609KS3GD DSA18/4619KS3GD DSA18/5619KS3GD • 15 35 20 - - 35 35 6 6 M30 x 1,5 M30 x 1,5 7 ÷ 40 7 ÷ 40 0,8 200 0,4 200 10 15 DSA30/4609KS3GD DSA30/5609KS3GD DSA30/4619KS3GD DSA30/5619KS3GD --- --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DSA6,5/4608LKS3GD) NO I A-22 brown black blue NC + --- I brown black blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-23 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. - SHORT SERIES • ATEX certified II 3GD for zone 2;22 • Connector output M12 x 1 • Housing I L1 L5 L2 L3 L4 d 2 M12 x 1 3 1 4 4 x LED Housing I-9 L1 L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-1 L1 L5 L2 L3 L4 Technical data: 2 d M12 x 1 3 4 4 x LED Diameter Nut Size Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: • Housing diameter 8 mm: • Housing diameters 12 ÷ 30 mm: • Sensing face: • • • • • • • • • • • 1 • • • • • • stainless steel nickel plated brass plastic Supply voltage (UB): see ordering references Max ripple: 10% ≤ 10 mA No-load supply current (Io): ≤ 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 I-9 I-9 • I-1 I-1 • I-1 I-1 • Rated operational current ( Ie ) Nominal sensing distance (Sn) ±10% mm mm mm n° mm • 5 26 21 13 13 8 8 47 47 6 - 8B -10 6 - 8B -10 M8 x 1 M8 x 1 7 ÷ 30 7 ÷ 30 4 3 200 1,5 200 2,5 DSA8/4309KS3GD DSA8/5309KS3GD DSA8/43C9KS3GD DSA8/53C9KS3GD • 7 30 23 10 10 8 8 48 48 6 - 8B -10 6 - 8B -10 M12 x 1 M12 x 1 7 ÷ 30 7 ÷ 30 2 1 200 200 2 4 DSA12/4309KS3GD DSA12/5309KS3GD DSA12/43C9KS3GD DSA12/53C9KS3GD • 10 25 15 16 16 8 8 49 49 6 - 8B -10 6 - 8B -10 M18 x 1 M18 x 1 5 ÷ 40 5 ÷ 40 0,8 200 0,6 200 5 8 DSA18/4309KS3GD DSA18/5309KS3GD DSA18/43C9KS3GD DSA18/53C9KS3GD • 15 25 25 17 17 8 8 50 65 6 - 8B -10 M30 x 1,5 6 - 8B -10 M30 x 1,5 7 ÷ 40 7 ÷ 40 0,8 200 0,4 200 10 15 DSA30/4309KS3GD DSA30/5309KS3GD DSA30/43C9KS3GD DSA30/53C9KS3GD L2 L3 L4 L5 Max switching frequency ( f ) mm L1 Supply voltage ( UB ) Body diameter (d) • mm Female connector (see page G - 1) I I mA ORDERING REFERENCES mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals V (min - max) KHz PNP (positive switching) NO I 1 brown 4 black 3 blue NC + I --- 1 brown 2 white 3 blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DSA8/4308KS3GD) NO I 1 brown 4 black 3 blue NC + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] 1 brown 2 white 3 blue + --- A-23 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-24 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. 3-wire - Extended sensing distance • ATEX certified II 3GD for zone 2;22 • Cable output Housing B L5 L2 L1 L3 d LED Housing B-4 L5 L2 L1 L3 d LED Housing B-2 L5 L1 L2 LED d Technical data: LED d Diameter Nut Size Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: B B • • B-4 B-4 • B-2 B-2 • B-5 B-5 • (*) Note: L2 L3 L4 L5 Body diameter (d) L1 Cable diameter Flush mounting (*) Non flush mounting Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. Housing diameters 6,5 and 8 mm: stainless steel Housing diameters 12 ÷ 30 mm: nickel plated brass Sensing face: plastic Housing • • • • • • • • • • • Use in hazardous area according to instruction manuals Hz Nominal sensing distance (Sn) ±10% L3 Rated operational current ( Ie ) L2 see ordering references 10% ≤ 10 mA ≤ 1,5 V - 25° ÷ + 60°C ± 10% 4% 10% IP67 yellow LED 0,22 mm2 in diameters 6,5 and 8 mm 0,35 mm2 in diameter 12 mm 0,50 mm2 in diameters 18 and 30 mm Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Max switching frequency ( f ) L5 L1 Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: Supply voltage ( UB ) Housing B-5 • • • • • • • • • • • mA mm ORDERING REFERENCES PNP (positive switching) NO I NC + I brown black blue + mm mm mm mm mm mm mm V (min - max) 5 40 35 5 5 - 45 45 3,5 3,5 M8 x 1 M8 x 1 7 ÷ 30 7 ÷ 30 800 200 400 200 3 4 DCE8/4609KS3GD DCE8/5609KS3GD DCE8/4619KS3GD DCE8/5619KS3GD • 7 43 36 7 7 - 50 50 4 4 M12 x 1 M12 x 1 7 ÷ 40 7 ÷ 40 800 200 600 200 4 6 DCE12/4609KS3GD DCE12/5609KS3GD DCE12/4619KS3GD DCE12/5619KS3GD • 10 50 40 - - 50 50 5 5 M18 x 1 M18 x 1 7 ÷ 40 7 ÷ 40 300 200 200 200 10 14 DCE18/4A09KS3GD DCE18/5A09KS3GD DCE18/4A19KS3GD DCE18/5A19KS3GD • 15 50 35 10 10 - 60 60 6 6 M30 x 1,5 M30 x 1,5 7 ÷ 40 7 ÷ 40 100 200 100 200 20 28 DCE30/4609KS3GD DCE30/5609KS3GD DCE30/4619KS3GD DCE30/5619KS3GD See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf --- --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCE8/4608LKS3GD) NO I A-24 brown black blue brown black blue NC + --- I brown black blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-25 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. - Extended sensing distance • ATEX certified II 3GD for zone 2;22 • Connector output M12x1 • Housing I-11 L1 L2 L5 L3 L4 2 M12 x 1 d 3 4 x LED Housing I-7 L1 1 4 L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-12 L1 L5 L2 L3 L4 2 M12 x 1 3 4 x LED L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: Flush mounting (*) Non flush mounting Housing • Housing diameter 8 mm: • Housing diameters 12 - 30 mm: • Sensing face: I - 11 I - 11 • I-7 I-7 • I - 12 I - 12 • I-2 I-2 • (*) Note: L1 L2 L3 L4 stainless steel nickel plated brass plastic L5 Body diameter (d) Nut Size Female connector (see page G - 1) Diameter • • • • • • • • • • • • • • • • • • Supply voltage (UB): see ordering references Max ripple: 10% 100 mA Rated operational current (Ie): ≤ 10 mA No-load supply current (Io): ≤ 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals Nominal sensing distance (Sn) ±10% L1 Technical data: Max switching frequency ( f ) Housing I-2 1 4 Supply voltage ( UB ) d ORDERING REFERENCES PNP (positive switching) NO I 1 brown 4 black 3 blue NC + I 1 brown 2 white 3 blue NO + NC + I 1 brown 4 black 2 white 3 blue + mm V (min-max) KHz mm M8 x 1 M8 x 1 7 ÷ 30 0,8 7 ÷ 30 0,4 3 4 DCE8/4309KS3GD DCE8/43C9KS3GD DCE8/5309KS3GD DCE8/53C9KS3GD 8 8 66 8B -10 M12 x 1 66 8B -10 M12 x 1 7 ÷ 40 0,8 7 ÷ 40 0,6 4 6 DCE12/4309KS3GD DCE12/43C9KS3GD DCE12/4329KS3GD DCE12/5309KS3GD DCE12/53C9KS3GD DCE12/5329KS3GD 19 19 8 8 77 8B -10 M18 x 1 87 8B -10 M18 x 1 7 ÷ 40 0,3 7 ÷ 40 0,2 10 DCE18/4309KS3GD DCE18/43C9KS3GD DCE18/4329KS3GD 14 DCE18/5309KS3GD DCE18/53C9KS3GD DCE18/5329KS3GD 17 17 8 8 90 8B -10 M30 x 1,5 7 ÷ 40 0,1 90 8B -10 M30 x 1,5 7 ÷ 40 0,1 20 DCE30/4309KS3GD DCE30/43C9KS3GD DCE30/4329KS3GD 28 DCE30/5309KS3GD DCE30/53C9KS3GD DCE30/5329KS3GD mm mm mm mm mm n° • 5 40 35 12 12 8 8 60 8B -10 60 8B -10 • 7 43 36 15 15 • 10 50 50 • 15 65 50 --- --- --- DCE8/4329KS3GD DCE8/5329KS3GD NPN (negative switching) See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Use the above part number changing the last 9 with 8 (ie DCE8/4308KS3GD) NO I 1 brown 4 black 3 blue NC + --- I 1 brown 2 white 3 blue NO + NC + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] 1 brown 4 black 2 white 3 blue + --- A-25 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-26 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • • • • AMPLIFIED IN d.c. 3-wire SHORT SERIES - Extended sensing distance ATEX certified II 3GD for zone 2;22 Cable output Housing A L1 L5 L2 d LED Housing B L1 L5 L2 d LED Housing B-4 L1 L5 L2 d Technical data: • • • • • • • • • • • LED d Diameter Nut Size Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: L2 L3 L4 L5 Body diameter (d) L1 Cable diameter Flush mounting (*) Non flush mounting Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. Housing diameters 6,5 and 8 mm: stainless steel Housing diameters 12 ÷ 30 mm: nickel plated brass Sensing face: plastic Housing • • • • • • • • • • • Use in hazardous area according to instruction manuals mm mm mm mm mm mm mm V (min - max) Hz Nominal sensing distance (Sn) ±10% L2 Rated operational current ( Ie ) L1 see ordering references 10% ≤ 10 mA ≤ 1,5 V - 25° ÷ + 60°C ± 10% 4% 10% IP67 yellow LED 0,22 mm2 in diameters 6,5 and 8 mm 0,35 mm2 in diameter 12 mm 0,50 mm2 in diameters 18 and 30 mm Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Supply voltage ( UB ) L5 Housing B-5 Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: Max switching frequency ( f ) LED mA mm ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue + --- A • - 30 - - 30 3,5 6,5 7 ÷ 30 800 200 3 DSE6,5/4609LKS3GD DSE6,5/4619LKS3GD B • - 30 - - 30 3,5 M8 x 1 7 ÷ 30 800 200 3 DSE8/4609KS3GD DSE8/4619KS3GD B-4 B-4 • • 7 30 23 - - 30 30 4 4 M12 x 1 M12 x 1 7 ÷ 30 7 ÷ 30 800 200 600 200 4 6 DSE12/4609KS3GD DSE12/5609KS3GD DSE12/4619KS3GD DSE12/5619KS3GD B-5 B-5 • • 10 35 25 - - 35 35 5 5 M18 x 1 M18 x 1 7 ÷ 40 7 ÷ 40 300 200 200 200 10 14 DSE18/4609KS3GD DSE18/5609KS3GD DSE18/4619KS3GD DSE18/5619KS3GD B-5 B-5 • • 15 35 20 - - 35 35 6 6 M30 x 1,5 M30 x 1,5 7 ÷ 40 7 ÷ 40 100 200 100 200 20 28 DSE30/4609KS3GD DSE30/5609KS3GD DSE30/4619KS3GD DSE30/5619KS3GD (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DSE6,5/4608LKS3GD) NO I A-26 brown black blue NC + --- I brown black blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-27 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. SHORT SERIES - Extended sensing distance ATEX certified II 3GD for zone 2;22 Connector output M12x1 • • • • Housing I L1 L5 L2 L3 L4 d 2 M12 x 1 3 1 4 4 x LED Housing I-9 L1 L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-1 L1 L5 L2 Technical data: L3 L4 • • • • • • • • • • • • 2 d M12 x 1 3 4 x LED Diameter Nut Size Thickness mm Max tightening torque Nm 1 4 M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: • Housing diameter 8 mm: • Housing diameters 12 ÷ 30 mm: • Sensing face: • • • • • • stainless steel nickel plated brass plastic Supply voltage (UB): see ordering references Max ripple: 10% 200 mA Rated operational current (Ie): ≤ 10 mA No-load supply current (Io): ≤ 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 4% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • I-9 I-9 • I-1 I-1 • I-1 I-1 • (*) Note: Nominal sensing distance (Sn) ±10% mm V (min - max) Hz mm M8 x 1 7 ÷ 30 800 3 DSE8/4309KS3GD DSE8/43C9KS3GD 8 8 48 6 - 8B -10 M12 x 1 48 6 - 8B -10 M12 x 1 7 ÷ 30 7 ÷ 30 800 600 4 6 DSE12/4309KS3GD DSE12/5309KS3GD DSE12/43C9KS3GD DSE12/53C9KS3GD 19 15 8 8 57 6 - 8B -10 M18 x 1 58 6 - 8B -10 M18 x 1 7 ÷ 40 7 ÷ 40 300 200 10 14 DSE18/4309KS3GD DSE18/5309KS3GD DSE18/43C9KS3GD DSE18/53C9KS3GD 17 17 8 8 50 6 - 8B -10 M30 x 1,5 65 6 - 8B -10 M30 x 1,5 7 ÷ 40 7 ÷ 40 100 100 20 28 DSE30/4309KS3GD DSE30/5309KS3GD DSE30/43C9KS3GD DSE30/53C9KS3GD L4 L5 mm mm mm mm mm - 26 13 8 47 6 - 8B -10 • 7 30 23 10 10 • 10 30 25 • 15 25 25 Max switching frequency ( f ) n° L3 Supply voltage ( UB ) L2 Body diameter (d) I L1 Female connector (see page G - 1) Flush mounting (*) Non flush mounting Housing Use in hazardous area according to instruction manuals See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf ORDERING REFERENCES PNP (positive switching) NO I 1 brown 4 black 3 blue NC + I --- 1 brown 2 white 3 blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DSE8/4308KS3GD) NO I 1 brown 4 black 3 blue NC + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] 1 brown 2 white 3 blue + --- A-27 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-28 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • • • • AMPLIFIED IN d.c. 3-wire - diameters 6,5 - 8 mm ATEX certified II 3GD for zone 2;22 With extended temperature range (-20° ÷ + 80°C) Cable output Housing A-3 L1 L5 L2 d LED Housing B-6 L5 L2 L1 L3 d LED Diameter Nut M8 x 1 Size SW13 Thickness mm 4 Max tightening torque Nm 10 Materials: • Cable: • Housing: • Sensing face: 2 m PVC; 105° C; 300 V; O.R. stainless steel plastic Technical data: • • • • • • • • • • • • • • • • • • Supply voltage (UB): 7 ÷ 30 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 80°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,35 mm2 Marking: II 3D Ex tc IIIC T100°C IP67 X II 3G Ex nAc IIC T5 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 B-6 • B-6 • • mm mm mm mm KHz mA mm 5 45 40 - 45 45 4 4 6,5 6,5 4 3 50 50 1,5 2,5 DCA6,5/4609LKST3GD DCA6,5/5609LKST3GD DCA6,5/4619LKST3GD DCA6,5/5619LKST3GD - 40 5 45 4 M8 x 1 4 50 1,5 DCA8/4609KST3GD DCA8/4619KST3GD 5 35 5 45 4 M8 x 1 3 50 2,5 DCA8/5609KST3GD DCA8/5619KST3GD L3 L5 Max switching frequency ( f ) mm L2 Body diameter (d) Nominal sensing distance (Sn) ±10% • Rated operational current ( Ie ) A-3 A-3 mm L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA6,5/4608LKST3GD) NO I A-28 brown black blue NC + --- I brown black blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-29 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire - diameter 12 mm ATEX certified II 3GD for zone 2;22 With extended temperature range (-20° ÷ + 80°C) Cable output • • • • Housing B-3 L1 L5 L2 L3 d LED Housing D L5 L1 L2 L4 L3 d LED Diameter Nut M12 x 1 Size SW17 Thickness mm 4 Max tightening torque Nm 15 Materials: • Cable: • Housing: • Sensing face: 2 m PVC; 105° C; 300 V; O.R. nickel plated brass plastic Technical data: • • • • • • • • • • • • • • • • • • Supply voltage (UB): 5 ÷ 40 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 20° ÷ + 80°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,35 mm2 Marking: II 3D Ex tc IIIC T100°C IP67 X II 3G Ex nAc IIC T5 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • • L5 mm mm mm mm mm mm 7 7 43 50 36 43 7 10 7 10 20 20 50 80 50 80 4 4 4 4 KHz mA mm M12 x 1 2 M12 x 1 2 M12 x 1 1,5 M12 x 1 1,5 50 50 50 50 2 2 4 4 mm Max switching frequency ( f ) L4 Body diameter (d) L3 Cable diameter L2 Nominal sensing distance (Sn) ±10% • • L1 Rated operational current ( Ie ) B-3 D B-3 D Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- DCA12/4609KST3GD DCA12/4709KST3GD DCA12/5609KST3GD DCA12/5709KST3GD brown black blue + --- DCA12/4619KST3GD DCA12/4719KST3GD DCA12/5619KST3GD DCA12/5719KST3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KST3GD) NO I brown black blue NC + --- I brown black blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] + --- A-29 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-30 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • • • • AMPLIFIED IN d.c. 3 and 4-wires - diameters 18 - 30 - 45 mm ATEX certified II 3GD for zone 2;22 With extended temperature range (-20° ÷ + 80°C) Cable output Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d Housing G-1 L5 L2 L3 Technical data: d • Supply voltage (UB): LED Diameter Nut M18 x 1 M30 x 1,5 M45 x 1,5 SW24 SW36 SW55 4 8 5 35 80 70 Size Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: • Sensing face: • • • • • • • • • • 2 m PVC; 105° C; 300 V; O.R. nickel plated brass plastic • • • • • • • diameter 18 mm: 5 ÷ 30 Vdc diameters 30 - 45 mm: 10 ÷ 30 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 2,2 V Voltage drop (Ud): Temperature range: - 25° ÷ + 80°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,50 mm2 in 3-wire version diameter 18 mm 0,35 mm2 in 4-wire version diameter 18 mm 0,50 mm2 for diameters 30 and 45 mm Marking: II 3D Ex tc IIIC T100°C IP67 X II 3G Ex nAc IIC T5 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Rated operational current ( Ie ) Nominal sensing distance (Sn) ±10% mm mm mm mm KHz mA mm B-2 B-2 • • 10 50 40 - - 50 50 5 5 M18 x 1 M18 x 1 1 1 50 50 5 8 DCA18/4A09KST3GD DCA18/4A19KST3GD DCA18/4A29KST3GD DCA18/5A09KST3GD DCA18/5A19KST3GD DCA18/5A29KST3GD G G • • 15 50 35 10 10 - 60 90 6 6 M30 x 1,5 0,8 M30 x 1,5 0,4 50 50 10 15 DCA30/4609KST3GD DCA30/4619KST3GD DCA30/4629KST3GD DCA30/5609KST3GD DCA30/5619KST3GD DCA30/5629KST3GD G-1 • 10 50 10 - 60 6 M45 x 1,5 0,15 50 20 DCA45/4609KST3GD DCA45/4619KST3GD DCA45/4629KST3GD L3 L4 L5 Max switching frequency ( f ) mm L2 Body diameter (d) mm L1 Cable diameter mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue NO + NC + I --- brown black white blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KST3GD) NO I A-30 brown black blue NC + --- I brown black blue NO + NC + --- I brown black white blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-31 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. ATEX certified II 3GD for zone 2;22 With extended temperature range (-20° ÷ + 80°C) Connector output M12x1 Housing I-11 L1 L2 L5 L3 L4 2 M12 x 1 d 3 L1 1 4 4 x LED Housing I-7 L5 L2 L3 L4 d 2 M12 x 1 3 1 4 4 x LED Housing I-12 L1 • • • • L5 L2 L3 L4 2 d M12 x 1 3 4 x LED L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Diameter Nut Size Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: I - 11 I - 11 • I-7 I-7 • I - 12 I - 12 • I-2 I-2 • L2 L3 L4 L5 mm Body diameter (d) L1 Female connector (see. page G -1) Flush mounting Non flush mounting Housing • Housing diameter 8 mm: stainless steel • Housing diameters 12- 18 - 30 mm: nickel plated brass • Sensing face: plastic • • • • • • • • • • • • • • • • • Supply voltage (UB): 10 ÷ 30 Vdc Max ripple: 10% ≤ 50 mA Rated operational current (Ie): ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 80°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Marking: II 3D Ex tc IIIC T100°C IP67 X II 3G Ex nAc IIC T5 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals KHz M8 x 1 M8 x 1 4 3 ORDERING REFERENCES PNP (positive switching) NO I 1 brown 4 black 3 blue NC + I 1 brown 2 white 3 blue NO + NC + I 1 brown 4 black 2 white 3 blue + mm mm mm mm • 5 40 35 12 12 8 8 60 8B -10 60 8B -10 • 7 43 36 15 15 8 8 66 8B -10 M12 x 1 66 8B -10 M12 x 1 2 1,5 2 4 DCA12/4309KST3GD DCA12/43C9KST3GD DCA12/5309KST3GD DCA12/53C9KST3GD • 10 50 50 19 19 8 8 77 8B -10 M18 x 1 87 8B -10 M18 x 1 1 1 5 8 DCA18/4309KST3GD DCA18/43C9KST3GD DCA18/4329KST3GD DCA18/5309KST3GD DCA18/53C9KST3GD DCA18/5329KST3GD • 15 65 50 17 17 8 8 90 8B -10 M30 x 1,5 0,8 90 8B -10 M30 x 1,5 0,4 n° mm Nominal sensing distance ( Sn ) ± 10% L1 Technical data: L5 Max switching frequency ( f ) Housing I-2 1 4 mm --- --- 1,5 DCA8/4309KST3GD DCA8/43C9KST3GD 2,5 DCA8/5309KST3GD DCA8/53C9KST3GD --- - 10 DCA30/4309KST3GD DCA30/43C9KST3GD DCA30/4329KST3GD 15 DCA30/5309KST3GD DCA30/53C9KST3GD DCA30/5329KST3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA8/4308KST3GD) NO I 1 brown 4 black 3 blue NC + --- I 1 brown 2 white 3 blue NO + NC + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] 1 brown 4 black 2 white 3 blue + --- A-31 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-32 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • • • • AMPLIFIED IN d.c. 3 and 4-wires - diameters 6,5 - 8 mm ATEX certified II 3GD for zone 2;22 For high temperatures with LED (-20° ÷ + 100°C) Cable output Housing A-3 L1 L5 L2 d LED Housing B-6 L5 L2 L1 L3 d LED Diameter Nut M8 x 1 Size SW13 Thickness mm 4 Max tightening torque Nm 10 Materials: Technical data: • Cable: 2 m Thermoplastic; 140°C; 300 V; O.R. • Housing: stainless steel • Sensing face: plastic • • • • • • • • • • • • • • • • • • Supply voltage (UB): 7 ÷ 30 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 100°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,35 mm2 Marking: II 3D Ex tc IIIC T120°C IP67 X II 3G Ex nAc IIC T4 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 B-6 • B-6 • • mm mm mm mm KHz mA mm 5 45 40 - 45 45 3,5 3,5 6,5 6,5 4 3 50 50 1,5 2,5 DCA6,5/4609LKSTB3GD DCA6,5/5609LKSTB3GD DCA6,5/4619LKSTB3GD DCA6,5/5619LKSTB3GD - 40 5 45 3,5 M8 x 1 4 50 1,5 DCA8/4609KSTB3GD DCA8/4619KSTB3GD 5 35 5 45 3,5 M8 x 1 3 50 2,5 DCA8/5609KSTB3GD DCA8/5619KSTB3GD L3 L5 Max switching frequency ( f ) mm L2 Body diameter (d) Nominal sensing distance (Sn) ±10% • Rated operational current ( Ie ) A-3 A-3 mm L1 Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA6,5/4608LKSTB3GD) NO I A-32 brown black blue NC + --- I brown black blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-33 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. 3-wire - diameter 12 mm ATEX certified II 3GD for zone 2;22 For high temperatures with LED (-20° ÷ + 100°C) Cable output • • • • Housing B-3 L1 L5 L2 L3 d LED Diameter Nut M12 x 1 Size SW17 Thickness mm 4 Max tightening torque Nm 15 Materials: • Cable: 2 m Thermoplastic; 140°C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic Technical data: • • • • • • • • • • • • • • • • • • Supply voltage (UB): 5 ÷ 40 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 100°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,35 mm2 Marking: II 3D Ex tc IIIC T120°C IP67 X II 3G Ex nAc IIC T4 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • mm mm mm mm mm KHz mA mm - 43 7 - 50 4 M12 x 1 2 50 2 DCA12/4609KSTB3GD DCA12/4619KSTB3GD 7 36 7 - 50 4 M12 x 1 1,5 50 4 DCA12/5609KSTB3GD DCA12/5619KSTB3GD L3 L4 L5 Max switching frequency ( f ) mm L2 Body diameter (d) mm L1 Cable diameter Nominal sensing distance (Sn) ±10% B-3 • Rated operational current ( Ie ) B-3 Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA12/4608KSTB3GD) NO I brown black blue NC + --- I brown black blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] + --- A-33 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-34 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • • • • AMPLIFIED IN d.c. 3 and 4-wires - diameter 18 - 30 - 45 mm ATEX certified II 3GD for zone 2;22 For high temperatures with LED (-20° ÷ + 100°C) Cable output Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d Housing G-1 L5 L2 L3 Technical data: d • Supply voltage (UB): LED Diameter Nut M18 x 1 M30 x 1,5 M45 x 1,5 SW24 SW36 SW55 4 5 5 35 80 70 Size Thickness mm Max tightening torque Nm • • • • • • • • • • Materials: • Cable: 2 m Thermoplastic; 140° C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic • • • • • • • diameter 18 mm: 5 ÷ 30 Vdc diameters 30 - 45 mm: 10 ÷ 30 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 2,2 V Voltage drop (Ud): Temperature range: - 25° ÷ + 100°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,50 mm2 in 3-wire version diameter 18 mm 0,35 mm2 in 4-wire version diameter 18 mm 0,50 mm2 in diameters 30 and 45 mm Marking: II 3D Ex tc IIIC T120°C IP67 X II 3G Ex nAc IIC T4 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Rated operational current ( Ie ) Nominal sensing distance (Sn) ±10% mm mm mm KHz mA mm B-2 B-2 • • 10 50 40 - 50 50 5 5 M18 x 1 M18 x 1 1 1 50 50 5 8 DCA18/4A09KSTB3GD DCA18/4A19KSTB3GD DCA18/4A29KSTB3GD DCA18/5A09KSTB3GD DCA18/5A19KSTB3GD DCA18/5A29KSTB3GD G G • • 15 50 35 10 10 60 90 6 6 M30 x 1,5 0,8 M30 x 1,5 0,4 50 50 10 15 DCA30/4609KSTB3GD DCA30/4619KSTB3GD DCA30/4629KSTB3GD DCA30/5609KSTB3GD DCA30/5619KSTB3GD DCA30/5629KSTB3GD G-1 • 10 50 10 60 6 M45 x 1,5 0,15 50 20 DCA45/4609KSTB3GD DCA45/4619KSTB3GD DCA45/4629KSTB3GD L3 L5 Max switching frequency ( f ) mm L2 Body diameter (d) mm L1 Cable diameter mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue NO + NC + I --- brown black white blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA18/4A08KSTB3GD) NO I A-34 brown black blue NC + --- I brown black blue NO + NC + --- I brown black white blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-35 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING AMPLIFIED IN d.c. ATEX certified II 3GD for zone 2;22 For high temperatures with LED (-20° ÷ + 100°C) Connector output M12x1 Housing I-11 L1 L2 L5 L3 L4 2 M12 x 1 d 3 L1 1 4 4 x LED Housing I-7 L5 L2 L3 L4 d 2 M12 x 1 3 Housing I-12 1 4 4 x LED L1 • • • • L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED L1 Technical data: • • • • • • • • • • • L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Diameter Nut Size Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 • • • • • • Materials: I - 11 I - 11 • I-7 I-7 • I - 12 I - 12 • I-2 I-2 • L3 L4 L5 mm Use in hazardous area according to instruction manuals Max switching frequency ( f ) L2 Body diameter (d) L1 Female connector (see page G - 1) Flush mounting Non flush mounting Housing • Housing diameter 8 mm: stainless steel • Housing diameters 12- 18 - 30 mm: nickel plated brass • Sensing face: plastic Supply voltage (UB): 10 ÷ 30 Vdc Max ripple: 10% ≤ 50 mA Rated operational current (Ie): ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 100°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Marking: II 3D Ex tc IIIC T120°C IP67 X II 3G Ex nAc IIC T4 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 KHz M8 x 1 M8 x 1 4 3 ORDERING REFERENCES PNP (positive switching) NO I 1 brown 4 black 3 blue NC + I 1 brown 2 white 3 blue NO + NC + I 1 brown 4 black 2 white 3 blue + mm mm mm mm • 5 40 35 12 12 8 8 60 8B -10 60 8B -10 • 7 43 36 15 15 8 8 66 8B -10 M12 x 1 66 8B -10 M12 x 1 2 1,5 2 4 DCA12/4309KSTB3GD DCA12/43C9KSTB3GD DCA12/5309KSTB3GD DCA12/53C9KSTB3GD • 10 50 50 19 19 8 8 77 8B -10 M18 x 1 87 8B -10 M18 x 1 1 1 5 8 DCA18/4309KSTB3GD DCA18/43C9KSTB3GD DCA18/4329KSTB3GD DCA18/5309KSTB3GD DCA18/53C9KSTB3GD DCA18/5329KSTB3GD • 15 65 50 17 17 8 8 90 8B -10 M30 x 1,5 0,8 90 8B -10 M30 x 1,5 0,4 n° mm Nominal sensing distance ( Sn ) ± 10% Housing I-2 mm --- 1,5 DCA8/4309KSTB3GD 2,5 DCA8/5309KSTB3GD --- DCA8/43C9KSTB3GD DCA8/53C9KSTB3GD --- - 10 DCA30/4309KSTB3GD DCA30/43C9KSTB3GD DCA30/4329KSTB3GD 15 DCA30/5309KSTB3GD DCA30/53C9KSTB3GD DCA30/5329KSTB3GD NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCA8/4308KSTB3GD) NO I 1 brown 4 black 3 blue NC + --- I 1 brown 2 white 3 blue NO + NC + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] 1 brown 4 black 2 white 3 blue + --- A-35 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-36 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • AMPLIFIED IN d.c. + a.c. 2-wires - Voltage 10 ÷ 50 V • ATEX certified II 3GD for zone 2;22 • Cable output Housing B-3 L5 L2 L1 L3 d LED Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d General features: Diameter Nut Size M12 x 1 M18 x 1 M30 x 1,5 SW17 SW24 SW36 4 4 5 15 35 80 Thickness mm Max tightening torque Nm These sensors are able to work with either direct or alternating current. Voltage drop and residual current are very low. They are not polarized and the load can be connected either of the leads. In many applications they can be used to replace mechanical microswitches. Technical data: Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic • • • • • • • • • • • • • • • • • • Supply voltage (UB): Electrical system frequency: Off-state current (Ir): Minimum operational current (Im): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: 10 ÷ 50 Vdc/Vac 40 ÷ 60 Hz ≤ 1 mA 5 mA ≤5V - 25° ÷ + 60°C ± 10% 2% 10% IP67 yellow LED 0,35 mm2 in diameter 12 mm 0,50 mm2 in diameter 18 mm 0,75 mm2 in diameter 30 mm Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Nominal sensing distance (Sn) ±10% mm mm mm Hz Hz mA mm • • 7 43 36 7 7 - 50 50 4 4 M12 x 1 M12 x 1 800 600 25 25 100 100 2 4 AXM12/4600KS3GD AXM12/5600KS3GD AXM12/4610KS3GD AXM12/5610KS3GD B-2 B-2 • • 10 58 48 12 12 - 70 70 5 5 M18 x 1 M18 x 1 800 400 25 25 200 200 5 8 AXM18/4A00KS3GD AXM18/5A00KS3GD AXM18/4A10KS3GD AXM18/5A10KS3GD G G • • 15 50 35 10 10 - 60 60 6 6 M30 x 1,5 M30 x 1,5 400 200 25 25 200 200 10 15 AXM30/4600KS3GD AXM30/5600KS3GD AXM30/4610KS3GD AXM30/5610KS3GD L4 L5 Max switching frequency ( f ) in a.c. mm L3 Max switching frequency ( f ) in d.c. mm L2 Body diameter (d) mm L1 Cable diameter Rated operational current ( Ie ) B-3 B-3 A-36 mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES NO I black black NC I black black BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-37 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING ANALOGUE LINEAR OUTPUT 4 ÷ 20 mA • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-2 L5 L1 L2 d Housing G L5 L1 L2 L3 d General features: These inductive proximity sensors provide an output current inversely or directly proportional to the distance between sensing face and metal target. The output current is dependent also on the target material. So the proximity sensors in addition to determining distance, displacements, vibrations and distortions can be used to recognize the composition of metal and alloys. Typical curves I (mA) 22 20 18 16 14 12 10 8 6 4 2 Graph 1 DCL18/5A09A DCL30/4609A DCL30/5609A Use of the sensor: The current flowing through the load RL, generates a variation in voltage across the resistor for a suitable value of RL, it is possible to obtain voltage variations from one tenth to 20 V as can be seen in the tables. DCL18/4A09A 1 2 3 4 5 6 7 8 9 10 12 14 16 18 d (mm) I (mA) Graph 2 22 20 18 16 14 12 10 8 6 4 2 DCL18/5A19A Technical data: DCL30/4619A • • • • • • • • DCL18/4A19A DCL30/5619A 1 2 3 4 5 6 7 8 9 10 12 14 16 18 d (mm) Connections brown +Vcc Vout RL blue Vout (V) 0,4 2 4 4...20mA - Vcc ... 2 ... 10 ... 20 RL (ohm) Vdc (min) 100 500 1000 15 20 30 RL (max) = (Vdc-10) KΩ 20 Diameter Nut Size Thickness mm Max tightening torque Nm M18 x 1 M30 x 1,5 SW24 SW36 4 5 35 50 Safety parameters: • • • • • Materials: Measurement range mm mm mm mm mm % mA Hz % mm • 10 50 40 - - 50 50 5 5 M18 x 1 M18 x 1 3 3 4 4 250 0,5 250 0,5 2÷6 3÷8 DCL18/4A09A DCL18/5A09A DCL18/4A19A DCL18/5A19A • 15 50 35 10 10 - 60 60 5 5 M30 x 1,5 M30 x 1,5 5 5 4 4 250 0,5 250 0,5 5 ÷ 12 7 ÷ 18 DCL30/4609A DCL30/5609A DCL30/4619A DCL30/5619A L2 L3 L4 L5 Body diameter (d) mm L1 Cable diameter Repeat accuracy (R) Use in hazardous area according to instruction manuals Max switching frequency ( f ) • These sensors must be used in conjunction with associated apparatus (See Sect. E) No- load supply current G G 30 V 100 mA 5 nF 750 μH 660 mW Maximum linearity error • Vi max: Ii max: Ci max: Li max: Pi max: mm Flush mounting Non flush mounting Housing • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic B-2 B-2 • • • • • • Supply voltage: 10 ÷ 30 Vdc Max ripple: 20% Output current range: 4 ÷ 20 mA Temperature range: - 10° ÷ + 60°C Max thermal drift: < 10% Degree of protection: IP67 Cable conductor cross section: 0,75 mm2 Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 010 Protected against short-circuit and overload Protected against any wrong connection Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-7/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 ORDERING REFERENCES INVERSELY PROPORTIONAL Graph 1 DIRECTLY PROPORTIONAL Graph 2 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-37 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-38 CYLINDRICAL INDUCTIVE ATEX SENSORS IN METAL HOUSING • ANALOGUE LINEAR OUTPUT 4 ÷ 20 mA • ATEX certified II 1GD for zone 0;20 • Connector output Housing I-12 L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 Housing A-2 L5 L1 L2 L3 L4 2 d M12 x 1 3 1 4 General features: These inductive proximity sensors provide an output current inversely or directly proportional to the distance between sensing face and metal target. The output current is dependent also on the target material. So the proximity sensors in addition to determining distance, displacements, vibrations and distortions can be used to recognize the composition of metal and alloys. It is recommended to use ATEX certified connectors type C8B/002...A or C10/002...A. Typical curves I (mA) DCL18/5309A 22 20 18 16 14 12 10 8 6 4 2 Graph 1 DCL30/4309A DCL30/5309A Use of the sensor: DCL18/4309A 1 2 3 4 5 6 7 8 The current flowing through the load RL, generates a variation in voltage across the resistor for a suitable value of RL, it is possible to obtain voltage variations from one tenth to 20 V as can be seen in the tables. 9 10 12 14 16 18 d (mm) I (mA) 22 20 18 16 14 12 10 8 6 4 2 Graph 2 DCL18/5319A DCL30/4319A Technical data: DCL18/4319A • • • • • • • DCL30/5319A 1 2 3 4 5 6 7 8 9 10 12 14 16 18 d (mm) Connections (1) brown +Vcc Vout RL (4) blue Vout (V) 4...20mA - Vcc 0,04 0,4 2 4 ... 0,2 ... 2 ... 10 ... 20 • • • • • • RL (ohm) Vdc (min) 10 100 500 1000 15 15 20 30 RL (max) = (Vdc-12) KΩ 20 Diameter Nut Size Thickness mm Max tightening torque Nm M18 x 1 M30 x 1,5 SW24 SW36 4 5 35 50 Materials: • Housing: • Sensing face: Supply voltage: Max ripple: Output current range: Temperature range: Max thermal drift: Degree of protection: Marking: 15 ÷ 30 Vdc 20% 4 ÷ 20 mA - 10° ÷ + 60°C < 10% IP67 II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 010 Protected against short-circuit and overload Protected against any wrong connection Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-7/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to IEN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 30 V 100 mA 5 nF 750 μH 660 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) nickel plated brass plastic Female connector (see page G - 1) Body diameter (d) Maximum linearity error No- load supply current Max switching frequency ( f ) Repeat accuracy (R) Measurement range I - 12 I - 12 • A-2 A-2 • A-38 mm mm mm mm mm n° mm % mA Hz % mm • 10 50 50 19 19 8 8 77 87 8B - 10 8B - 10 M18 x 1 M18 x 1 3 3 4 4 250 0,5 250 0,5 2÷6 3÷8 DCL18/4309A DCL18/5309A DCL18/4319A DCL18/5319A • 15 65 50 17 17 8 8 87 90 8B - 10 8B - 10 M30 x 1,5 M30 x 1,5 5 5 4 4 250 0,5 250 0,5 5 ÷ 12 7 ÷ 18 DCL30/4309A DCL30/5309A DCL30/4319A DCL30/5319A Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals L1 L2 L3 L4 L5 ORDERING REFERENCES INVERSELY PROPORTIONAL Graph 1 DIRECTLY PROPORTIONAL Graph 2 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-39 CYLINDRICAL INDUCTIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES WITH LED diameter 8 mm • ATEX certified II 1GD for zone 0;20 • Cable output • Housing B-14 L5 d LED Diameter Nut M8 x 1 Size SW13 Thickness mm 4 Max tightening torque Nm Materials: • Cable: • Housing: • Nuts: 1 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic nickel plated brass General features: With this new series of sensors it’s possible to drive specific inputs for NAMUR sensors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally triggered and monitored by LED. The special material of the housing allows the use without additional protections against electrostatic charges. Technical data: • • • • • • • • • • • • • • • • • • • Working voltage: 7,7 ÷ 9 Vdc Max ripple: 10% ≤ 1 mA Off-state current (Ir): 2 mA Minimum operational current (Im): 10 mA Rated operational current (Ie): < 6,5 V Voltage drop (Ud) with load 10 mA: <5V Voltage drop (Ud) with load 8 mA: Temperature range: - 20° ÷ +60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,35 mm2 Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 011 X Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • B -14 B -14 • • L4 L5 Use in hazardous area according to instruction manuals Nominal sensing distance ( Sn ) ± 10% L3 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Max switching frequency (f) L2 Body diameter (d) L1 Cable diameter Flush mounting Non flush mounting (*) Housing (*) Note: For non flush mounting version, it’s recommended to leave the sensing face outside of metal for a length equal to a half of the external diameter. Vi max: Ii max: Ci max: Li max: Pi max: ORDERING REFERENCES NO I NC brown blue + Rx I brown blue --- + Rx mm mm mm mm mm mm mm KHz mm - - - - 30 4 M8 x 1 3 1,5 DC8P/4600SA DC8P/4610SA - - - - 30 4 M8 x 1 2 2,5 DC8P/5600SA DC8P/5610SA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] --- A-39 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-40 CYLINDRICAL INDUCTIVE ATEX SENSORS IN PLASTIC HOUSING • NAMUR SERIES WITH LED diameters 12 - 18 - 30 mm • ATEX certified II 1GD for zone 0;20 • Cable output Housing B-15 L5 d LED Housing B-16 General features: L5 With this new series of sensors it’s possible to drive specific inputs for NAMUR sensors or inputs for 2 wires amplified switches with low current (up to 10 mA). The load can be applied on both terminals (function PNP or NPN). The output is internally triggered and monitored by LED. The special material of the housing allows the use without additional protections against electrostatic charges. LED d Technical data: Housing B-17 • • • • • • • • • • • • • • L5 LED d Diameter Nut Size M12 x 1 M18 x 1 M30 x 1,5 SW17 SW24 SW36 4 4 5 1 4 20 Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: • Nuts: • 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic nickel plated brass • • • • • • Working voltage: Max ripple: Off-state current (Ir): Minimum operational current (Im): Rated operational current (Ie): Voltage drop (Ud) with load 10 mA: Voltage drop (Ud) with load 8 mA: Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: 7,7 ÷ 9 Vdc 10% ≤ 1 mA 2 mA 10 mA < 6,5 V <5V - 20° ÷ +60°C ± 10% 2% 10% IP67 yellow LED 0,35 mm2 in diameter 12 mm 0,75 mm2 in diameters 18 and 30 mm Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 Certified IMQ 08 ATEX 010 Protected against short-circuit and overload Protected against any wrong connection Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • B-15 B-15 • B -16 B -16 • B -17 B -17 • A-40 L4 L5 Nominal sensing distance ( Sn ) ± 10% L3 Use in hazardous area according to instruction manuals Max switching frequency (f) L2 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Body diameter (d) L1 Cable diameter Flush mounting Non flush mounting (*) Housing (*) Note: For non flush mounting version, it’s recommended to leave the sensing face outside of metal for a length equal to a half of the external diameter. Vi max: Ii max: Ci max: Li max: Pi max: ORDERING REFERENCES NO I NC brown blue + Rx --- I brown blue + Rx --- mm mm mm mm mm mm mm KHz mm • - - - - 30 30 4 4 M12 x 1 M12 x 1 2 1 2 4 DC12P/4600KSA DC12P/5600KSA DC12P/4610KSA DC12P/5610KSA • - - - - 30 30 5 5 M18 x 1 M18 x 1 0,8 0,6 5 8 DC18P/4600KSA DC18P/5600KSA DC18P/4610KSA DC18P/5610KSA • - - - - 35 35 5 5 M30 x 1,5 M30 x 1,5 0,8 0,4 10 15 DC30P/4600KSA DC30P/5600KSA DC30P/4610KSA DC30P/5610KSA BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-41 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - TYPE Z • ATEX certified II 1GD for zone 0;20 • Cable output • 16 10 = 3,1 sensing zone 2,8 3,5 28 22,5 2,75 6 = 10,3 Ø 3,1 Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 Model ∆I with metal ∆d General features: D (mm) This sensor has the same shape and holes position as a type V3 microswitch. The cable position allows the mounting on every side of the housing. The special material of the housing allows the use without additional protections against electrostatic charges. Sn (switching point) Type Z Max tightening torque Nm Materials: • Cable: • Housing: Technical data: 1,5 • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,15 mm2 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic Safety parameters: • • • • • Flush mounting Non flush mounting (*) Note: • • See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Cable diameter Sensing zone diameter Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Max switching frequency (f) Nominal sensing distance ( Sn ) ± 10% ORDERING REFERENCES I brown blue Rx mm mm KHz mm 3 9 1 2 DCZ/4600A 3 9 0,8 4 DCZ/5600A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-41 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-42 RECTANGULAR INDUCTIVE ATEX SENSORS • NAMUR SERIES - TYPE T • ATEX certified II 1GD for zone 0;20 • Cable output 25 12 sensing zone 16 4 3,1 = 6,5 = 18 32 40 5,1 4 Ø 3,1 Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 Model ∆I with metal ∆d General features: D (mm) These sensors are suitable for reduced mounting spaces. The special material of the housing allows the use without additional protections against electrostatic charges. Sn (switching point) Technical data: Type T Max tightening torque Nm Materials: • Cable: • Housing: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,35 mm2 • Marking: II 1D Ex iaD 20 T80°C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 1 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic Safety parameters: • • • • • Flush mounting Non flush mounting (*) Note: • • A-42 See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Cable diameter Sensing zone diameter Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Max switching frequency (f) Nominal sensing distance ( Sn ) ± 10% ORDERING REFERENCES I brown blue Rx mm mm KHz mm 4 9 1 2 DCT/4700A 4 9 0,8 4 DCT/5700A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-43 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - TYPE X and Y • ATEX certified II 1GD for zone 0;20 • Cable output • Housing N 10 25 50 3 Ø 4,2 8 7 4 Ø 7,3 10 sensing zone 15 Housing N-2 15 14,5 30 sensing zone 50 4 6 Ø 4,2 Ø 8,2 General features: These sensors are suitable for reduced mounting spaces. The special material of the housing allows the use without additional protections against electrostatic charges. 19 Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,75 mm2 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 Model Max tightening torque Nm Materials: • Cable: • Housing: with metal D (mm) Sn (switching point) Type X Type Y 1 2,5 Safety parameters: • • • • • 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Flush mounting Non flush mounting Housing (*) Note: ∆I ∆d N N • N-2 N-2 • Cable diameter Sensing zone diameter Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Max switching frequency (f) Nominal sensing distance ( Sn ) ± 10% ORDERING REFERENCES I brown blue Rx mm mm KHz mm • 5 5 15 15 2 1 5 8 DCX/4700A DCX/5700A • 5 5 23 23 0,8 0,4 10 15 DCY/4700A DCY/5700A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-43 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-44 RECTANGULAR INDUCTIVE ATEX SENSORS • NAMUR SERIES - TYPE P - 5 Position head • ATEX certified II 1G for zone 0 • Terminal block output 40 45 40 1 3 2 4 7,3 60 112 Ø 5,3 30 Pg13,5 34 Connections + RX --- General features: 3 4 1 2 These sensors are described as “revolving head” because the actual sensor head, inside the plastic body, can be arranged in 5 different positions. To choose the desired direction it is sufficient to remove the cover, remove the head and positioning it according to the user’s particular requirements. The internal terminal block can be reached easily by removing the front cover. The particular plastic material allows the use without additional protections against electrostatic charges. Typical curve Technical data: I(mA) 4 • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529 (with fully locked gland): IP65 • Marking: II 1G Ex ia IIC T6 without metal 3 1,75mA 2 1,55mA 1 0 ∆I with metal ∆d D (mm) Sn (switching point) Model Type P Max tightening torque Nm • • • • 4 Cable gland clamping range (mm) 5 ÷ 12 Certified IMQ 08 ATEX 010 Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: Materials: • Housing: • Cable gland: plastic nickel plated brass • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Flush mounting Non flush mounting Use in hazardous area according to instruction manuals • • A-44 Revolving head diameter Max switching frequency (f) Nominal sensing distance ( Sn ) ± 10% ORDERING REFERENCES I 1 brown 2 blue Rx mm KHz mm 35 0,2 15 DCP/4700A 35 0,2 20 DCP/5700A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-45 RECTANGULAR INDUCTIVE ATEX SENSORS NAMUR SERIES - diameter 80 mm • ATEX certified II 1GD for zone 0;20 • Cable and connector output • Housing P 80 65 65 5,5 80 sensing zone 45 15 5,5 Housing P-1 80 65 65 80 5,5 sensing zone M12 x 1 45 15 General features: 5,5 Suitable for detection of large targets. The special material of the housing allows the use without additional protections against electrostatic charges. Typical curve Technical data: I(mA) 4 • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,75 mm2 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 without metal 3 1,75mA 2 1,55mA 1 0 ∆I with metal ∆d D (mm) Sn (switching point) Model Type DC80... Max tightening torque Nm Materials: • Cable: • Housing: 5 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic Safety parameters: • • • • • Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Nominal sensing distance ( Sn ) ± 10% Max switching frequency (f) Body diameter (d) Female connector (see page G - 1) Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals mm n° mm KHz mm ORDERING REFERENCES I 1 brown 2 blue Rx P • 5 - 80 0,5 40 DC80/5800A P-1 • - 8B - 10 80 0,5 40 DC80/5300A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] + --- A-45 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-46 RECTANGULAR INDUCTIVE ATEX SENSORS • NAMUR SERIES - TYPE R • ATEX certified II 1GD for zone 0;20 • Cable and connector output Housing R-1 30 83 59 65 sensing zone 111 Ø 6,4 20 100 Housing R-2 30 M12 x1 83 General features: Suitable for detection of large targets. The special material of the housing allows the use without additional protections against electrostatic charges. 59 65 sensing zone 111 Ø 6,4 20 Technical data: 100 • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,75 mm2 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Typical curve I(mA) 4 without metal 3 1,75mA 2 1,55mA 1 0 ∆I with metal ∆d Model Type R Max tightening torque Nm Safety parameters: 1,5 Materials: • Cable: • Housing: D (mm) Sn (switching point) • • • • • 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic Vi max: Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Nominal sensing distance ( Sn ) ± 10% Max switching frequency (f) Sensing zone diameter Female connector (see page G - 1) Cable diameter Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I 1 brown 2 blue mm n° mm KHz mm Rx R-1 • 5 - 65 0,3 55 DCR/5800A R-2 • - 8B - 10 65 0,3 55 DCR/5300A A-46 + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-47 RECTANGULAR INDUCTIVE ATEX SENSORS AMPLIFIED IN d.c. 3-wire - TYPE Z • ATEX certified II 3GD for zone 2;22 • Cable output • 16 10 = sensing zone 3,1 3,5 28 22,5 2,75 6 = 10,3 3 x LED 2,8 Model Ø 3,1 Type Z Max tightening torque Nm 1,5 Materials: • Cable: • Housing: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic General features: This sensor has the same shape and fixing holes as V3 standard microswitches. The particular cable position allows the mounting on every side of the housing. The special material of the housing allows the use without additional protections against electrostatic charges. The output status is indicated by LED visible from 3 sides. Technical data: • • • • • • • • • • • • • • • • • • Supply voltage (UB): 7 ÷ 30 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 1,5 V Voltage drop (Ud): Temperature range: - 25° ÷ + 60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,15 mm2 Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Flush mounting Non flush mounting Use in hazardous area according to instruction manuals • • Cable diameter Sensing zone diameter Rated operational current ( Ie ) Max switching frequency (f) ORDERING REFERENCES Nominal sensing distance ( Sn ) ± 10% PNP (positive switching) NO I brown black blue NC + I brown black blue + mm mm mA KHz mm 3 9 200 2 2 DCAZ/4609KS3GD DCAZ/4619KS3GD 3 9 200 1,5 4 DCAZ/5609KS3GD DCAZ/5619KS3GD --- --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCAZ/4608KS3GD) (*) Note: See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf NO I brown black blue NC + --- I brown black blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] + --- A-47 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-48 RECTANGULAR INDUCTIVE ATEX SENSORS • AMPLIFIED IN d.c. 3 and 4-wires - TYPE T • ATEX certified II 3GD for zone 2;22 • Cable output 25 12 sensing zone 16 4 3,1 = 6,5 = 18 32 40 5,1 3 x LED 4 Ø 3,1 Model Type T Max tightening torque Nm Materials: • Cable: • Housing: 1 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic General features: These sensors are suitable for reduced mounting spaces. The special material of the housing allows the use without additional protections against electrostatic charges. Technical data: • • • • • • • • • • • Supply voltage (UB): Max ripple: No-load supply current (Io): Voltage drop (Ud): Temperature range: Max thermal drift of sensing distance Sr: Repeat accuracy (R): Switching hysteresis max (H): Degree of protection: Switch status indicator: Cable conductor cross section: 5 ÷ 40 Vdc 10% ≤ 10 mA < 1,5 V - 25° ÷ + 60°C ± 10% 2% 10% IP67 yellow LED 0,25 mm2 in 4-wire version 0,35 mm2 in 3-wire version Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • mm KHz mA mm 4 9 1 200 2 DCAT/4709KS3GD DCAT/4719KS3GD DCAT/4729KS3GD 4 9 0,8 200 4 DCAT/5709KS3GD DCAT/5719KS3GD DCAT/5729KS3GD Max switching frequency ( f ) mm Sensing zone diameter Nominal sensing distance (Sn) ±10% • Use in hazardous area according to instruction manuals Rated operational current ( Ie ) • See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Cable diameter Non flush mounting Flush mounting (*) Note: • • • • • • ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue NO + NC + I --- brown black white blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCAT/4708KS3GD) NO I A-48 brown black blue NC + --- I brown black blue NO + NC + --- I brown black white blue + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-49 RECTANGULAR INDUCTIVE ATEX SENSORS AMPLIFIED IN d.c. 3 and 4-wires - TYPE X and Y • ATEX certified II 3GD for zone 2;22 • Cable output • Housing N 10 25 3 LED Ø 4,2 8 7 4 Ø 7,3 50 10 sensing zone 15 15 30 14,5 Housing N-2 50 sensing zone 4 LED 6 Ø 4,2 Ø 8,2 General features: 19 Model Max tightening torque Nm Materials: • Cable: • Housing: Type Y 1 2,5 Technical data: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic • N-2 N-2 • • • • • • • Supply voltage (UB): 7 ÷ 60 Vdc Max ripple: 10% ≤ 10 mA No-load supply current (Io): < 2,2 V Voltage drop (Ud): Temperature range: - 25° ÷ + 60°C ± 10% Max thermal drift of sensing distance Sr: Repeat accuracy (R): 2% Switching hysteresis max (H): 10% Degree of protection: IP67 Switch status indicator: yellow LED Cable conductor cross section: 0,50 Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Protected against any wrong connection Suppression of initial false impulse Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Use in hazardous area according to instruction manuals mA mm • 5 5 - 15 15 1 1 200 200 5 8 DCAX/4609KS3GD DCAX/4619KS3GD DCAX/4929KS3GD DCAX/5609KS3GD DCAX/5619KS3GD DCAX/5929KS3GD • 5 5 - 23 23 0,8 0,4 200 200 10 15 DCAY/4609KS3GD DCAY/4619KS3GD DCAY/4629KS3GD DCAY/5609KS3GD DCAY/5619KS3GD DCAY/5629KS3GD Max switching frequency (f) KHz Sensing zone diameter mm Female connector (v. page G - 1) n° Cable diameter mm Non flush mounting Nominal sensing distance ( Sn ) ± 10% N N • • • • • • • • • • • • Rated operational current ( Ie ) See mounting precautions at page 22 of BDC General Catalogue or at this URL: http://www.bdcelectronic.com/eng/pdfeng/022-024.pdf Flush mounting Housing (*) Note: Type X This series is suitable to the mounting in guideway. The flush mounting version can be placed side by side. The special material of the housing allows the use without additional protections against electrostatic charges. ORDERING REFERENCES PNP (positive switching) NO I brown black blue NC + I --- brown black blue NO + NC + I --- brown black white blue + --- NPN (negative switching) Use the above part number changing the last 9 with 8 (ie DCAX/4608KS3GD) NO I brown black blue NC + --- I brown black blue NO + NC + I --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] brown black white blue + --- A-49 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-50 SLOT INDUCTIVE ATEX SENSORS • NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output Housing U 11 Ø2 8 3 9 19 3,5 6,5 3 5 5 5 10 Housing Q 11 Ø2 8 3 8,5 19 5,5 3 5 5 5 5 10 Housing S 24 Ø 3,5 16,5 10,6 5 10,6 29,5 9,8 13 General features: 12 6 15,5 8 19 30,5 I(mA) without metal 3 1,75mA 2 1,55mA 1 0 Model Max tightening torque Nm Materials: • Cable: • Housing: ∆I with metal ∆d Technical data: • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 2 • Cable conductor cross section: 0,14 mm in types DF3,5/… and DF5/… 0,75 mm2 in type DF6/… • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Typical curve 4 These sensors are able to detect the presence of a metal blade into the slot. The switching point of the output happens when about the 70% of internal faces is covered by the blade. The special material of the housing allows the use without additional protections against electrostatic charges. D (mm) Sn (switching point) Type DF3,5/... Type DF5/... Type DF6/... 0,25 0,25 0,75 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic Safety parameters: • • • • • Vi max Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Housing A-50 Cable diameter Gap width Max switching frequency ( f ) Minimum penetration ORDERING REFERENCES I brown blue Rx mm mm KHz mm U 3 3,5 3 5 DF3,5/4600A Q 3 5 3 5 DF5/4600A S 5 5 1 9 DF6/4600A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina A-51 SLOT INDUCTIVE ATEX SENSORS NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output • Housing T 18 17 41 15,5 15 15,5 24,5 30 24,5 Ø5 Housing V 30 80 24 40 50 24 44 Ø 6,5 30 24 Typical curve I(mA) 4 General features: without metal These sensors are able to detect the presence of a metal blade into the slot. The switching point of the output happens when about the 70% of internal faces is covered by the blade. The special material of the housing allows the use without additional protections against electrostatic charges. 3 1,75mA 2 1,55mA 1 0 Model Max tightening torque Nm Materials: • Cable: • Housing: ∆I with metal ∆d Technical data: D (mm) Sn (switching point) Type DF15/... Type DF30/... 4 5 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≤ 1 mA without metal: ≥ 3 mA • Temperature range: - 20° ÷ + 60°C ± 10% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 2% • Degree of protection according EN60529: IP67 • Cable conductor cross section: 0,75 mm2 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Vi max Ii max: Ci max: Li max: Pi max: 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Housing Cable diameter Gap width Max switching frequency ( f ) Minimum penetration ORDERING REFERENCES I brown blue Rx mm mm KHz mm T 5 15 0,8 16 DF15/4600A V 5 30 0,3 30 DF30/4600A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] A-51 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-1 HOW TO INTERPRETE THE ORDERING REFERENCES ATEX CAPACITIVE SENSORS NKS 3 6 18 NKS = capacitive NOT amplified d.c. NAMUR series P = plastic housing P/ 4 6 00A -5 PR = with connector M12 x 1 = standard type cable output Cable length (if required different than standard 2m) For Polyurethane cable add PR BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] B-1 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-3 CYLINDRICAL CAPACITIVE ATEX SENSORS IN METAL HOUSING NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output • Housing C-1 L5 L2 L3 Trimmer d Housing G-2 L5 L2 L3 Trimmer d Typical curve General features: I(mA) The capacitive sensors are used for detecting any material. Some materials, especially if liquid or metallic, can be detected also through plastic or glass walls. They can be used for various applications: level control in storage bins or tanks; survey filling bottles; rain sensor; anti-vandalism tab; etc. The adjustment of sensing distance is made by a potentiometer at the back of the housing. 4 3 2 1,65 1 Sn (switching point) Diameter Size Nut Thickness mm Max tightening torque Nm Technical data: D(mm) M18 x 1 M30 x 1,5 SW24 SW36 4 5 35 80 Materials: • Cable: 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. • Housing: nickel plated brass • Sensing face: plastic • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≥ 3 mA without metal: ≤ 1 mA • Temperature range: - 20° ÷ + 60°C ± 20% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 4% • Degree of protection: IP65 • Cable conductor cross section: 0,75 mm2 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Wood Water 1 0,5 0,5 0,15 0,1 0,25 1 L1 L2 L3 L4 L5 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Nominal sensing distance ( Sn ) ± 10% (trimmable) Paper Max switching frequency (f) Cloth Cable diameter PVC Flush mounting Non flush mounting Glass Housing Steel Body diameter (d) Reduction factor of the sensing distance for different target materials (T amb = 25°C) Vi max: Ii max: Ci max: Li max: Pi max: mm mm mm mm mm mm mm Hz mm ORDERING REFERENCES C brown blue Rx C-1 • - 50 10 - 60 5 M18 x 1 100 2÷5 NKS18/4600A G-2 • - 50 10 - 60 5 M30 x 1,5 100 4 ÷ 10 NKS30/4600A + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] B-3 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-4 CYLINDRICAL CAPACITIVE ATEX SENSORS IN METAL HOUSING • NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Connector output Housing I-13 L5 L2 L3 L4 2 d M12 x 1 3 1 4 Housing A-5 L5 L2 L3 L4 2 d M12 x 1 3 1 4 Typical curve I(mA) General features: 4 The capacitive sensors are used for detecting any material. Some materials, especially if liquid or metallic, can be detected also through plastic or glass walls. They can be used for various applications: level control in storage bins or tanks; survey filling bottles, etc. 3 2 1,65 1 Sn (switching point) Diameter Size Nut Thickness mm Max tightening torque Nm Technical data: D(mm) M18 x 1 M30 x 1,5 SW24 SW36 4 5 35 80 Materials: • Housing: • Sensing face: nickel plated brass plastic • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≥ 3 mA without metal: ≤ 1 mA • Temperature range: - 20° ÷ + 60°C ± 20% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 4% • Degree of protection according EN60529: IP67 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Wood Water 1 0,5 0,5 0,15 0,1 0,25 1 L1 L2 L3 L4 L5 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Nominal sensing distance ( Sn ) ± 10% Paper Max switching frequency (f) Cloth Female connector (see page G - 1) PVC Flush mounting Non flush mounting Glass Housing Steel Body diameter (d) Reduction factor of the sensing distance for different target materials (T amb = 25°C) Vi max: Ii max: Ci max: Li max: Pi max: mm mm mm mm mm n° mm Hz mm ORDERING REFERENCES C 1 brown 4 blue Rx I - 13 • - 50 19 8 77 8B - 10 M18 x 1 100 5 NKS18/4300A A-5 • - 65 15 8 88 8B - 10 M30 x 1,5 100 10 NKS30/4300A B-4 + --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina B-5 CYLINDRICAL CAPACITIVE ATEX SENSORS IN PLASTIC HOUSING NAMUR SERIES • ATEX certified II 1GD for zone 0;20 • Cable output • Housing C-1 L5 L2 L3 Trimmer d Housing G-2 L5 L2 L3 Trimmer d Typical curve General features: I(mA) The capacitive sensors are used for detecting any material. Some materials, especially if liquid or metallic, can be detected also through plastic or glass walls. They can be used for various applications: level control in storage bins or tanks; survey filling bottles; rain sensor; anti-vandalism tab; etc. The adjustment of sensing distance is made by a potentiometer at the back of the housing. The special material of the housing allows the use without additional protections against electrostatic charges. 4 3 2 1,65 1 Sn (switching point) Diameter Size Nut Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: • Nuts: Technical data: D(mm) M18 x 1 M30 x 1,5 SW24 SW36 4 5 4 20 2 m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic nickel plated brass • Supply voltage according NAMUR: 7,7 ÷ 9 Vdc • Max ripple: 10% • Consumption at 8,2 V with Rx = 1000 Ω with metal: ≥ 3 mA without metal: ≤ 1 mA • Temperature range: - 20° ÷ + 60°C ± 20% • Max thermal drift of sensing distance Sr: • Repeat accuracy (R): 4% • Degree of protection: IP65 • Cable conductor cross section: 0,75 mm2 • Marking: II 1D Ex iaD 20 T80° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • Electromagnetic compatibility (EMC) according to EN60947-5-2 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 • Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 Safety parameters: • • • • • Wood Water 1 0,5 0,5 0,15 0,1 0,25 1 L1 L2 L3 L4 L5 13,5 V 60 mA 100 nF 100 μH 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Nominal sensing distance ( Sn ) ± 10% (trimmable) Paper Max switching frequency (f) Cloth Cable diameter PVC Flush mounting Non flush mounting Glass Housing Steel Body diameter (d) Reduction factor of the sensing distance for different target materials (T amb = 25°C) Vi max: Ii max: Ci max: Li max: Pi max: mm mm mm mm mm mm mm Hz mm ORDERING REFERENCES C brown blue Rx + --- C-1 • - 50 10 - 60 5 M18 x 1 100 2÷5 NKS18P/4600A G-2 • - 50 10 - 60 5 M30 x 1,5 100 4 ÷ 10 NKS30P/4600A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] B-5 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-1 HOW TO INTERPRETE THE ORDERING REFERENCES ATEX MAGNETIC SENSORS BMS = activated by external magnet BMSN = activated by ferromagnetic target with NAMUR output Diameter of cylindrical sensors. For other types, change the number with the following: W BMSN A 12/ = rectangular plastic 19 x 28,5 x 10,5 mm 4600 A -5 PR = category 1G - 1D Cable length (if required different than standard 2m) For Polyurethane cable add PR BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] C-1 Catalogo Atex 2013 Inglese_03 14-04-2013 20:54 Pagina C-3 CYLINDRICAL MAGNETIC ATEX SENSORS IN METAL HOUSING REED CONTACT 2-wire ATEX certified II 1GD for zone 0;20 Detection of external magnets Associated apparatus not required - Cable output • • • • Housing B-10 L5 magnet N (S) S (N) SW7 d Housing B-12 L5 magnet N (S) SW10 S (N) d Diameter Nut Size M8 x 1 M12 x 1 SW13 SW17 4 4 10 20 Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. stainless steel General features: These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the power of the magnet (see page C-9), which must be ordered separately. Reed contacts are able to drive directly dc loads (PNP/NPN). The extremely strong construction allows the use in the most difficult conditions even with high pressures on the housing. Technical data: • • • • • • • • • • Working voltage: Output logic: Contact resistance max: Operate time max: Release time max: Temperature range: Degree of protection: Cable conductor cross section: Pressure on the front side max: Marking: II 1D Ex maD 20 T80° C II 1G Ex ma II T6 • Certified IMQ 08 ATEX 002 X • According to: EN60079-0/EN60079-18/EN60079-26 5 ÷ 30 Vdc normally open 0,1 Ω 1 ms 0,4 ms - 20 ÷ + 60°C IP67 0,35 mm2 150 bar Body diameter (d) Max switching frequency (f) Rated operational current ( Ie ) mm mm mm mm mm mm mm KHz mA B -10 - - - - 35 4 M8 x 1 0,5 500 BMS8/4600MA B -12 - - - - 35 4 M12 x 1 0,5 500 BMS12/4600MA Housing Cable diameter Use in hazardous area according to instruction manuals L1 L2 L3 L4 L5 ORDERING REFERENCES M brown blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] C-3 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-4 CYLINDRICAL MAGNETIC ATEX SENSORS IN METAL HOUSING • • • • REED CONTACT 2-wire - NAMUR output ATEX certified II 1GD for zone 0;20 Detection of external magnets Cable output Housing B-10 L5 magnet N (S) S (N) SW7 d Housing B-12 L5 magnet N (S) SW10 S (N) d General features: Diameter Nut Size M8 x 1 M12 x 1 SW13 SW17 4 4 10 20 Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. stainless steel These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the power of the magnet (see page C-9), which must be ordered separately. The output impedance is compatible with NAMUR standard, allowing the diagnostic of the connections. The extremely strong construction allows the use in the most difficult conditions even with high pressures on the housing. Technical data: • Working voltage: 7,7 ÷ 9 Vdc • Output logic: normally open • Consumption at 8,2 V with Rx = 1000 Ω activated: ≥ 3 mA non-activated: ≤ 1 mA • Operate time max: 1 ms • Release time max: 0,4 ms • Temperature range: - 20 ÷ + 60°C • Degree of protection: IP67 • Cable conductor cross section: 0,35 mm2 • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60947-5-6/EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: • Ii max: • Pi max: 13,5 Vdc 60 mA 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Body diameter (d) Max switching frequency (f) Rated operational current ( Ie ) mm mm mm mm mm mm mm KHz mA B -10 - - - - 35 4 M8 x 1 0,5 100 BMSN8/4600A B -12 - - - - 35 4 M12 x 1 0,5 100 BMSN12/4600A Housing Cable diameter Use in hazardous area according to instruction manuals C-4 L1 L2 L3 L4 L5 ORDERING REFERENCES M brown blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-5 RECTANGULAR MAGNETIC ATEX SENSORS REED CONTACT 2-wire ATEX certified II 1GD for zone 0;20 For pneumatic cylinders Cable output • • • • General features: This sensor detects the position of the magnetic ring inside a standard pneumatic cylinder with a T slot. The sensor remains completely recessed and thus mechanically protected. Reed contact provides for a direct driving of DC (PNP/NPN). Technical data: • • • • • • • • • Working voltage: Output logic: Contact resistance max: Operate time max: Release time max: Temperature range: Degree of protection: Cable conductor cross section: Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60079-0/EN60079-11/EN60079-26 10 ÷ 30 Vdc normally open 0,1 Ω 1 ms 0,4 ms - 20 ÷ + 60°C IP67 0,14 mm2 Safety parameters: • Vi max: • Ii max: • Pi max: Materials: • Cable: • Sensor: PVC CEI 20-22 II; 90°C; 300V plastic Housing S-1 Use in hazardous area according to instruction manuals 27,2 Ø3 6,1 hexagonal screw 1,3 mm 3 Housing These sensors must be used in conjunction with associated apparatus (See Sect. E) 29,2 4,4 5 S-1 30 Vdc 100 mA 750 mW Cable diameter Rated operational current ( Ie ) Max switching frequency (f) mm mA KHz 3 100 0,5 2000 ORDERING REFERENCES M brown blue BMS/4600A Note: different cable lengths must be specified at the end of the code. Ex: BMS/4600A -1 for 1m of cable with connector. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] C-5 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-6 RECTANGULAR MAGNETIC ATEX SENSORS • • • • REED CONTACT 2-wire - NAMUR output ATEX certified II 1GD for zone 0;20 For pneumatic cylinders Cable output General features: This sensor detects the position of the magnetic ring inside a standard pneumatic cylinder with a T slot. The sensor remains completely recessed and thus mechanically protected. The output impedance is compatible with NAMUR standard, allowing the diagnostic of the connections. Technical data: • Working voltage: 7,7 ÷ 9 Vdc • Output logic: normally open • Consumption at 8,2 V with Rx = 1000 Ω activated: ≥ 3 mA non-activated: ≤ 1 mA • Operate time max: 1 ms • Release time max: 0,4 ms • Temperature range: - 20 ÷ + 60°C • Degree of protection: IP67 • Cable conductor cross section: 0,14 mm2 • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60957-5-6/EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: • Ii max: • Pi max: Materials: • Cable: • Sensor: PVC CEI 20-22 II; 90°C; 300V plastic Housing S-1 Housing C-6 Use in hazardous area according to instruction manuals 27,2 5 S-1 These sensors must be used in conjunction with associated apparatus (See Sect. E) 29,2 4,4 3 13,5 Vdc 60 mA 200 mW Ø3 6,1 hexagonal screw 1,3 mm Cable diameter Max switching frequency (f) mm KHz 3 0,5 2000 ORDERING REFERENCES M brown blue BMSN/4600A Note: different cable lengths must be specified at the end of the code. Ex: BMS/4600A -1 for 1m of cable with connector. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-7 RECTANGULAR MAGNETIC ATEX SENSORS REED CONTACT 2-wire ATEX certified II 1GD for zone 0;20 TYPE Z and W Cable output Housing Z-1 • • • • 16 10 10,3 2,75 3,1 2,8 3,5 28 22,5 sensing zone Ø 3,1 Housing W-1 9,5 10,5 3,4 28,5 11,5 20,5 4,5 9,5 General features: 5 These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the power of the magnet (see page C-9), which must be ordered separately. The special material of the housing allows the use without additional protections against electrostatic charges. 4,5 Ø 6,5 Technical data: Model Type Z Type W 1,5 0,75 Max tightening torque Nm Materials: • Cable: • Housing: • • • • • • • • 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic Working voltage: Output logic: Contact resistance max: Operate time max: Release time max: Temperature range: Degree of protection: Cable conductor cross section: • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60079-0/EN60079-11/EN60079-26 10 ÷ 30 Vdc normally open 0,1 Ω 1 ms 0,4 ms - 20 ÷ + 60°C IP67 0,14 mm2 in Type Z 0,35 mm2 in Type W Safety parameters: • Vi max: • Ii max: • Pi max: 30 Vdc 100 mA 750 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals ORDERING REFERENCES Max switching frequency (f) Rated operational current ( Ie ) mm KHz mA Z-1 3 0,5 100 BMSZ/4600A W-1 5 0,5 100 BMSW/4600A Housing Cable diameter NO M brown blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] C-7 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-8 RECTANGULAR MAGNETIC ATEX SENSORS REED CONTACT 2-wire - NAMUR output ATEX certified II 1GD for zone 0;20 TYPE Z and W Cable output Housing Z-1 16 10 10,3 28 3,1 2,75 22,5 sensing zone 2,8 3,5 • • • • Ø 3,1 Housing W-1 9,5 9,5 10,5 3,4 These sensors produce an output contact activated by an external magnetic field, independent by the polarity of the field. The activation distance depends upon the power of the magnet (see page C-9), which must be ordered separately. The output impedance complies with the NAMUR standard, allowing the diagnostic of the connections. The special material of the housing allows the use without additional protections against electrostatic charges. 5 28,5 11,5 20,5 4,5 General features: 4,5 Technical data: • Working voltage: • Output logic: • Consumption at 8,2 V with Rx = 1000 Ω activated: non-activated: • Operate time max: • Release time max: • Temperature range: • Degree of protection: • Cable conductor cross section: Ø 6,5 Model Type Z Type W 1,5 0,75 Max tightening torque Nm Materials: • Cable: • Housing: 2m PVC CEI 20 - 22 II; 90°C; 300 V; O.R. plastic 7,7 ÷ 9 Vdc normally open ≥ 3 mA ≤ 1 mA 1 ms 0,4 ms - 20 ÷ + 60°C IP67 0,14 mm2 in Type Z 0,35 mm2 in Type W • Marking: II 1D Ex iaD 20 T60° C II 1G Ex ia IIC T6 • Certified IMQ 08 ATEX 010 • According to: EN60957-5-6/EN60079-0/EN60079-11/EN60079-26 Safety parameters: • Vi max: • Ii max: • Pi max: 13,5 Vdc 60 mA 200 mW These sensors must be used in conjunction with associated apparatus (See Sect. E) Use in hazardous area according to instruction manuals Rated operational current ( Ie ) mm KHz mA Z-1 3 0,5 100 BMSNZ/4600 W-1 5 0,5 100 BMSNW/4600 Housing C-8 ORDERING REFERENCES Max switching frequency (f) Cable diameter NO M brown blue BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina C-9 MAGNETIC ATEX SENSORS MAGNETS FOR SENSORS • Fig. A - Nickel plated L dØ Fig. B - Epoxy encapsulated L dØ Fig. C - Epoxy coated Ø 9,5 Ø 4,2 dØ L Fig. D - Epoxy encapsulated 10 16 10,3 2,8 10,5 9,5 9,5 • Housing B: • Housing D - E: 11,5 20,5 28,5 N Use in hazardous area according to instruction manuals Materials: 4,5 3,3 General features: These magnets can be used as actuators for all the magnetic sensors which need an external activation magnet. They’re suitable for applications up to 70° C. For particular applications contact our technical office. In the ordering reference table there are approximate detection distances obtained with different types of BDC sensors. The special material of the housing allows the use without additional protections against electrostatic charges. Ø 3,1 Fig. E - Epoxy encapsulated 3,4 3,5 28 22,5 2,75 3,1 Housing S Nut Diameter Size Thickness mm Max tightening torque Nm 4,5 Fig. stainless steel plastic L DETECTION DISTANCE With solid state sensors B C D SW13 - - 4 - - 10 x 1,5 ORDERING REFERENCES mm mm With Reed sensors A A A 5 8 10 3 3,6 5 6 13 20 15 22 30 MAG-T53 MAG-T83 MAG-T105 B M8x1 20 10 17 MAG-M820 C 13 6 25 45 MAG-TF136 D - - 13 22 MAG-Z -A E - - 15 27 MAG-W-A BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] C-9 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-1 HOW TO INTERPRETE THE ORDERING REFERENCES ATEX SPEED SENSORS DSD ASD = with integrated control in d.c. = with integrated control in a.c. Diameter DSD 18 / 4 3 6 = with connector M12 x 1 = standard type cable output K S = protection against short circuit and overload = LED output status 3 0 9 KS 3GD -5 Cable length (if required different than standard 2m) BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] D-1 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-3 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Speed sensors with integrated control function 3-wire - d.c. ATEX certified II 3GD for zone 2;22 Connector output M12 x 1 Housing I-7 L1 L5 L2 L3 L4 d 2 M12 x 1 3 Housing I-12 1 4 4 x LED L1 • • • • L5 L2 L3 L4 2 d M12 x 1 3 1 4 4 x LED Housing I-2 L5 L1 L2 L3 L4 General features: 2 d M12 x 1 3 1 4 4 x LED Diameter Nut Size Thickness mm Max tightening torque Nm M8 x 1 M12 x 1 M18 x 1 M30 x 1,5 SW13 SW17 SW24 SW36 4 4 4 5 10 15 35 80 Materials: • Housing diameter 8 mm: stainless steel • Housing diameters 12 - 18 - 30 mm: nickel plated brass • Sensing face: plastic These sensors enable the control with extremely high precision the rotation of a toothed wheel or reference marks, switching off the load or giving an alarm in case the speed falls below the minimum threshold. Thanks to the extremely wide measuring range they can be even used to control repetitive operations, signalling in case of unwanted stops. Further delays or other special functions may be implemented upon specific request. The output is protected against wrong connection, overvoltages on line, and short circuit of the load. The connection is with a 4-wire M12x1 connector which must be ordered separately. Technical data: • • • • • • • • • • • • • • • • • • Working voltage: 10 ÷ 30 Vdc Max ripple: 10% No-load supply current: <15 mA 100 mA Rated operational current (Ie): Voltage drop: < 1,5 V Switching hysteresis (H): <10% Sn Repeat accuracy (R ): < 2% Sn Maximum detectable interval (between two pulses): 2 min Detectable start-up time (T1): 0 ÷1 min (default 2 sec.) Temperature range: - 25° ÷ + 60°C ±10% Max thermal drift of sensing distance Sn: Degree of protection: IP67 Status indicator: yellow LED = out ON; frequency over the threshold Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 I-7 I-7 • I - 12 I - 12 • I-2 I-2 • L4 L5 Nominal sensing distance (Sn) ±10% L3 Max detectable frequency L2 Body diameter (d) L1 Female connector (see page G - 1) Flush mounting (*) Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES PNP (positive switching) I 1 brown 2 white 4 black 3 blue + teach 10 ÷ 30 Vdc mm mm mm mm mm n° mm KHz mm • 7 43 36 15 15 8 8 66 66 8B -10 8B -10 M12 x 1 M12 x 1 1 1 2 4 DSD12/4309KS3GD DSD12/5309KS3GD • 10 50 50 19 19 8 8 77 87 8B -10 8B -10 M18 x 1 M18 x 1 1 1 5 8 DSD18/4309KS3GD DSD18/5309KS3GD • 15 65 50 17 17 8 8 90 90 8B -10 8B -10 M30 x 1,5 M30 x 1,5 0,8 0,4 10 15 DSD30/4309KS3GD DSD30/5309KS3GD --- BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] D-3 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-4 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Example of application Motor Sensor 1 Brown 2 White 4 Black 3 Blue Teach Motor Power Use of the sensor: + On power on, the yellow LED lights and the output switches to the ON state, driving the relay, which will drive the motor. After a start up delay time (T1) the sensor measures the speed of the motor and compares it to the threshold value. If the speed is under the threshold value, the output goes OFF, turning off the LED. The minimum threshold can be either factory preset or can be programmed from the sensor application with no need to perform any measurement. 10 ÷ 30 Vdc --- Threshold self-teaching procedure: Procedure 1 There are two different ways to perform the self-teaching of the threshold: RPM 1- Acquisition of start up time and calculation of the threshold from the maximum speed: Max th = (Max-20%) a) connect the Teach input (white) to the positive of power supply (brown) before turning on the power T T1 OUT b) Turn on the power supply to the machine and to the sensor and wait the speed gets the nominal value. The yellow LED will flash 4 times to indicate the acquisition complete c) Turn off the power supply d) At this stage the sensor has acquired the start up time (T1) and calculated the threshold as the maximum value of the speed reduced of -20% ON OFF T e) Disconnect the Teach in from the positive of power supply before running the machine again. 2 - Acquisition of a known threshold (start up time is not modified): Procedure 2 RPM a) Turn the power supply on to the machine and sensor and accelerate to the speed you want to get as threshold (th) th T b) Connect temporarily the Teach input (white) to the positive of power supply. This operation can be easily done with a push-button on the operator panel of the machine. c) At this stage the current speed becomes the minimum threshold (th), under of which the sensor goes in OFF state. Teach Both of the procedures can be repeated unlimited times. UB 0V T OUT ON T D-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-5 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Speed sensors with integrated control function 2-wire - a.c. ATEX certified II 3GD for zone 2;22 Cable output • • • • Housing B-2 L5 L1 L2 LED d Housing G L5 L1 L2 L3 LED d General features: Diameter Nut Size Thickness mm Max tightening torque Nm Materials: • Cable: • Housing: • Sensing face: M18 x 1 M30 x 1,5 SW24 SW36 4 5 35 80 These sensors enable the control with extremely high precision the rotation of a toothed wheel or reference marks, switching off the load in case of the speed falls below the minimum threshold. Thanks to the extremely wide measuring range they can be even used to control repetitive operations, signalling in case of unwanted stops. They are able to drive directly a.c. relays from 90 to 240 Vac with no need external power supply or amplifiers. Further delays or other special functions may be implemented upon specific request. The output is protected against wrong connection, overvoltages on line, and short circuit of the load. 2m PVC - CEI 2022 II- 90°C 300V-O.R. nickel plated brass plastic Technical data: • • • • • • • • • • • • • • • • • • • Working voltage: 90 ÷ 240 Vac Electrical system frequency: 40 ÷ 60 Hz Off-state current at 220 V: <2,2 mA Minimum operational current: 8 mA Voltage drop: <8V Switching hysteresis (H): <10% Sn Repeat accuracy (R): <2% Sn Maximum detectable interval (between two pulses): 2 min Detectable start-up time (T1): 0 ÷1 min (default 2 sec.) Temperature range: -25° ÷ +60°C ±10% Max thermal drift of sensing distance Sn: Degree of protection: IP67 Cable conductor cross section: 0,50mm2 Status indicator: yellow LED = out ON; frequency over the threshold red LED = out OFF; frequency under the threshold blinking red LED = out OFF; short circuit on the output Marking: II 3D Ex tc IIIC T80°C IP67 X II 3G Ex nAc IIC T6 X Protected against short-circuit and overload Electromagnetic compatibility (EMC) according to EN60947-5-2 According to: EN60079-0/EN60079-15/EN60079-31 Shock and vibration resistance according to EN60068-2-27/EN60068-2-6 • Class 2 equipment according to EN61140 Rated operational current ( Ie ) Nominal sensing distance (Sn) ±10% mm mm mm mm Hz mA mm C C • • 10 50 40 - - 50 50 5 5 M18 x 1 M18 x 1 800 400 200 200 5 8 ASD18/4A09KS3GD ASD18/5A09KS3GD G G • • 15 50 35 10 10 - 60 60 6 6 M30 x 1,5 M30 x 1,5 400 200 200 200 10 15 ASD30/4609KS3GD ASD30/5609KS3GD L3 L4 L5 Max detectable frequency mm L2 Body diameter (d) mm L1 Cable diameter mm Flush mounting Non flush mounting Housing Use in hazardous area according to instruction manuals ORDERING REFERENCES I brown black blue teach 90 ÷ 240 Vac BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] D-5 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina D-6 ATEX SPEED SENSORS WITH INTEGRATED CONTROL Example of application Motor Sensor Use of the sensor: Brown Black Teach 90 ÷ 240 Vac Blue On power on, the yellow LED lights and the output switches to the ON state, driving the relay, which will drive the motor. After a start up delay time (T1) the sensor measures the speed of the motor and compares it to the threshold value. If the speed is under the threshold value, the output goes OFF, giving an alarm indication with the red LED. The minimum threshold can be either factory preset or can be programmed from the sensor application with no need to perform any measurement. Procedure 1 RPM Threshold self-teaching procedure: Max There are two different ways to perform the self-teaching of the threshold: th = (Max-20%) T T1 1 - Acquisition of start up time and calculation of the threshold from the maximum speed: a) connect the Teach input (black) to the brown before turning on the power OUT b) Turn on the power supply to the machine and to the sensor and wait the speed gets the nominal value c) Turn off the power supply ON OFF T d) At this stage the sensor has acquired the start up time (T1) and calculated the threshold as the maximum value of the speed reduced of -20% e) Disconnect the Teach in from the brown wire before running the machine again. Procedure 2 RPM 2 - Acquisition of a known threshold (start up time is not modified): a) Turn the power supply on to the machine and sensor and accelerate to the speed you want to get as threshold (th). th T Teach b) Connect temporarily the Teach input (black) to the brown wire. This operation can be easily done with a push-button on the operator panel of the machine. c) At this stage the current speed becomes the minimum threshold (th), under of which the sensor goes in OFF state. Both of the procedures can be repeated unlimited times. UB 0V T OUT ON T D-6 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-1 HOW TO INTERPRETE THE ORDERING REFERENCES AMPLIFIERS AND REPEATERS FOR ATEX SENSORS 0 = supply voltage 24 Vdc 1 = supply voltage 115-230 Vac 3 = Inputs for contacts or NAMUR proximity sensors 1 = Analogue input 4-20 mA D 1 0 3 0 S 0 = relay output 1 = optocoupled static output S = single output D = 2 outputs Q = 4 outputs BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] E-1 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-3 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater 99 Relay Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 1 or 2 channels • 1 2 3 4 5 6 7 8 PWR ON 1 2 STATUS /FAULT 13 14 15 16 114,5 22,5 Technical Data: • Supply: General Description: The Switch/Proximity Detector Repeater type D1030 is a DIN Rail unit with one or two independent channels. The unit can be configured for contact or proximity detector, NO or NC and for NE or ND SPDT relay output contact. Each channel enables a Safe Area load to be controlled by a switch, or a proximity detector, located in Hazardous Area. D1030D dual channel type has two independent input channels and actuates the corresponding output relay. Two actuation modes can be independently DIP switch configured on each input channel: NO input/NE relay or NO input/ND relay. Contact or proximity sensor and its connection line short or open circuit fault detection is also DIP switch configurable: fault detection can be enabled (in case of fault it de-energizes the corresponding output relay and turns the fault LED on) or disabled (in case of fault the corresponding output relay repeats the input line open or closed status as configured). D1030S single channel type has one input channel and two output relays; the unit has two DIP switch configurable operating modes: Mode A) input channel actuates in parallel the two output relays (DPDT contact). Relay actuation mode can be independently configured for each output in two modes: NO input/NE relay or NO input/ND relay. Mode B) input channel actuates output relay A configurable in two modes as in mode A above. Output relay B operates as a fault output (in case of input fault, relay B actuates and the fault LED turns on while relay A repeats the input line as configured). Actuation can be DIP switch configured in two modes: No input fault/energized relay (it de-energizes in case of fault) or No input fault/de-energized relay (it energizes in case of fault). Function: 1 or 2 channels I.S. switch repeater for contact or EN60947-5-6 proximity. Provides 3 port isolation (input/output/supply). Signalling LEDs: Power supply indication (green), output status (yellow), line fault (red). Field Configurability: NO/NC input for contact/proximitor, NE/ND relay operation and fault detection enable/disable. 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp • Isolation (Test Voltage): I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; Out/Supply 1.5 KV; Out/Out 1.5 KV • Input switching current levels: ON ≥ 2,1 mA, OFF ≤ 1,2 mA, switch current ≈ 1,65 mA ± 0,2 mA hysteresis • Fault current levels: open fault ≤ 0,2 mA, short fault ≥ 6,8 mA, (when enabled both faults de-energize channel relay with dual channel unit D1030D or actuate fault relay with single channel unit D1030S). • Input equivalent source: 8 V 1 KΩ typical (8 V no load, 8 mA short circuit) • Output: Contact material: Contact rating: Mechanical/Electrical life: Operate/Release time: Bounce time NO/NC contact: Response time: Frequency response: voltage free SPDT relay contact AgCdO 2 A 250 Vac 500 VA, 2 A 250 Vdc 80 W (resistive load) 30 * 106/1 * 105, typical 7/3 ms, typical 3/5 ms 20 ms maximum10 Hz • Environmental conditions: Operating: temperature limits -20 to + 60° C, relative humidity max 90% non condensing, up to 35° C Storage: temperature limits -45 to + 80° C • Mounting: Connection: T35 DIN Rail according to EN50022 by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to2,5 mm2 • Degree of protection: IP 20 • Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 2004/108/CE EMC Directive EMC: compatibility to EN61000-6-2, EN61000-6-4 Use in hazardous area according to instruction manuals Voltage N° channels Current consumption (mA) (@24 Vdc, input closed, relays energized) Power dissipation (W) (@24 Vdc, input closed, relays energized) Max power consumption (W) (@30 Vdc, in short circuit, relays energized) Weight (g) 24 V.d.c. 1 55 1,3 1,7 130 D1030S 24 V.d.c. 2 60 1,4 1,8 about 135 D1030D ORDERING REFERENCES BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] E-3 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-4 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Approvals: Safety parameters: II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, II 3G Ex nA IIC T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, [Ex iaD] associated electrical apparatus. Uo/Voc = 10,7 V, Io/Isc = 15 mA, Po/Po = 39 mW at terminals 13-14, 15-16. Um = 250 Vrms, -20 ° C ≤ Ta ≤ 60 ° C. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. MAXIMUM EXTERNAL PARAMETERS Group Co/Ca CENELEC (uF) IIC IIB IIA 2,23 15,60 69,00 Lo/La (mH) Lo/Ro (uH/ohm) Terminals 13-14, 15-16 172 689 1379 930 3720 7440 Uo/Voc = 10,7 V Io/Isc = 15 mA Po/Po = 39 mW DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079-26 IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC6007926, IEC61241-0, IEC61241-11, GM International CRR028 conforms to EN60079-0, EN60079-15, UL & C-UL E222308 conforms to UL913 (Div.1), UL 60079-0 (General, All Zones), UL60079-11 (Intrinsic Safety “i” Zones 0 & 1) for UL and CSA-C22.2 No.157-92 (Div.1), CSA-E60079-0 (General, All Zones), CSA-E60079-11 (Intrinsic Safety “i” Zones 0 & 1) for C-UL, FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, 3611, 3810 e C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15, Russia according to GOST 12.2.007.0-75, R 51330.0-99, R 51330.10-99 [Exia] IIC X, Ukraine according to GOST 12.2.007.0, 22782.0, 22782.5 Exia IIC X, DNV and KR Type Approval Certificate for marine applications. NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Connections HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL D1030D COMMON POSITIVE CONNECTION voltage free contact Proximity In 1 voltage free contact = + - 13 + - 15 = = 14 Proximity In 2 = 16 3+ 4- Supply 24 Vdc 8 NC 2 NO 1 COM Out 1 7 NC 6 NO 5 COM Out 2 MODEL D1030S = voltage free contact In 1 Proximity + - 13 14 = = = 3+ 4- Supply 24 Vdc 8 NC 2 NO 1 COM Out 1-A 7 NC 6 NO 5 COM Out 2-B Relay contact shown in de-energized position E-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-5 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Transistor Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 2 or 4 channels • 2 3 4 6 7 8 99 1 5 PWR ON 1 2 3 4 STATUS /FAULT 9 10 11 12 13 14 15 16 114,5 22,5 Technical Data: General Description: The Switch/Proximity Detector Repeater type D1031 is a DIN Rail unit with two or four independent channels. The unit can be configured for contact or proximity detector, NO or NC and for NO or NC optocoupled open collector transistor output. Each channel enables a Safe Area load to be controlled by a switch, or a proximity detector, located in Hazardous Area. • Supply: D1031Q quad channel type has four independent input channels and actuates the corresponding output transistor. Two actuation modes can be independently DIP switch configured on each input channel: NO input/NC transistor or NO input/NO transistor. Contact or proximity sensor and its connection line short or open circuit fault detection is also DIP switch configurable: fault detection can be enabled (in case of fault it de-energizes the corresponding output transistor and turns the fault LED on) or disabled (in case of fault the corresponding output transistor repeats the input line open or closet status as configured). • Isolation (Test Voltage): D1031D dual channel type has two input channels and four output transistors; the unit has two DIP switch configurable operating modes: Mode A) input channel actuates in parallel the two output transistors. Transistor actuation mode can be independently configured for each output in two modes: NO input/NC transitor or NO input/NO transistor. Mode B) input channel actuates output transistor A configurable in two modes as in mode A above. Output transistor B operates as a fault output (in case of input fault, transistor B actuates and the fault LED turns on while transistor A repeats the input line as configured). Actuation can be DIP switch configured in two modes: No input fault/energized transistor (it de-energizes in case of fault) or No input fault/de-energized transistor (it energizes in case of fault). Function: 2 or 4 channels I.S. switch repeater for contact or EN60947-5-6 proximity. Provides 3 port isolation (input/output/supply). Signalling LEDs: Power supply indication (green), output status (yellow), line fault (red). Field Configurability: NO/NC input for contact/proximitor, NO/NC transistor operation and fault detection enable/disable. 12 - 24 Vdc nom (from 10 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp Current consumption @ 24V: 50 mA for 4 channels D1031Q, 40 mA for 2 channels D1031D with input closed and transistors energized Current consumption @ 12V: 100 mA for 4 channels D1031Q, 80 mA for 2 channels D1031D with input closed and transistors energized In S.I./Out 1,5 KV; In S.I./Supply 1,5 KV; Out/Supply 500 V; Out 1-3/Out 2-4 500 V • Input switching current levels: ON ≥ 2,1 mA, OFF ≤ 1,2 mA, switch current ≈ 1,65 mA ± 0,2 mA hysteresis • Fault current levels: open fault ≤ 0,2 mA, short fault ≥ 6,8 mA, (when enabled both faults de-energize channel transistor with quad channel unit D1031Q or actuate fault transistor with dual channel unit D1031D) • Input equivalent source: 8 V 1 KΩ typical (8 V no load, 8 mA short circuit) • Output: voltage free SPST optocoupled open-collector transistor Open-collector rating: 100 mA at 35 V (voltage drop ≤ 2,0 V) Leakage current: ≤ 50 A at 35 V) Response time: 500 s Frequency response: maximum1 KHz • Environmental conditions: Operating: temperature limits -20 to + 60° C, relative humidity max 90% non condensing, up to 35° C Storage: temperature limits -45 to + 80° C • Mounting: Connection: T35 DIN Rail according to EN50022 by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2,5 mm2 • Degree of protection: IP 20 • Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 2004/108/CE EMC Directive EMC: compatibility to EN61000-6-2, EN61000-6-4 Use in hazardous area according to instruction manuals Voltage N° channels Power dissipation (W) (@24 Vdc, input closed, transistors energized) Max power consumption (W) (@30 Vdc, in short circuit, transistors energized) Weight (g) 12 - 24 V.d.c. 2 1 1 120 D1031D 12 - 24 V.d.c. 4 1,2 1,4 about 130 D1031Q ORDERING REFERENCES BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] E-5 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-6 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Approvals: Safety parameters: II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, II 3G Ex nA II T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, [Ex iaD] associated electrical apparatus. Uo/Voc = 10,7 V, Io/Isc = 15 mA, Po/Po = 39 mW at terminals 13-14, 15-16, 9-10, 11-12. Um = 250 Vrms, -20 ° C ≤ Ta ≤ 60 ° C. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. MAXIMUM EXTERNAL PARAMETERS Group Co/Ca CENELEC (uF) IIC IIB IIA 2,23 15,60 69,00 Lo/La (mH) Lo/Ro (uH/ohm) Terminals 13-14, 15-16 172 689 1379 930 3720 7440 Uo/Voc = 10,7 V Io/Isc = 15 mA Po/Po = 39 mW DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079-26 IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26, IEC61241-0, IEC61241-11, IMQ 09 ATEX 013 X conforms to EN60079-0,EN60079-15, UL & C-UL E222308 conforms to UL913 (Div.1), UL 60079-0 (General, All Zones), UL60079-11 (Intrinsic Safety “i” Zones 0 & 1) for UL and CSA-C22.2 No.157-92 (Div.1), CSA-E60079-0 (General, All Zones), CSA-E60079-11 (Intrinsic Safety “i” Zone 0 & 1), UL60079-15 (“n” Zone 2), UL 1604 (Div. 2) for UL and CSA-C22.2 No. 157-92 (Div. 1), CSA-E60079-11 (Intrinsic Safety “i” Zone 0 & 1), CSA-E60079-15 (“n” Zone 2) for C-UL, FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, 3611, 3810 e C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15, Russia according to GOST 12.2.007.0-75, R 51330.0-99, R 51330.10-99 [Exia] IIC X, Ukraine according to GOST 12.2.007.0, 22782.0, 22782.5 Exia IIC X, DNV and KR Type Approval Certificate for marine applications. NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Connections HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL D1031D voltage free contact COMMON POSITIVE CONNECTION Proximity In 1 + - 13 In 2 + - 15 = = = 3+ Supply 12-24 Vdc 4Out 1-A 1 2 Common Channel 1 14 Out 2-A 5 6 Common Channel 2 16 Out 1-B 7 2 Common Channel 1 Out 2-B 8 6 Common Channel 2 = MODEL D1031Q voltage free contact E-6 COMMON POSITIVE CONNECTION Proximity In 1 + - 13 In 2 + - 15 In 3 + - 9 In 4 + - 11 = = 3+ Supply 12-24 Vdc 4Out 1 1 2 Common Channels 1-3 14 Out 2 5 6 Common Channels 2-4 16 Out 3 7 2 Common Channels 1-3 10 12 = = Out 4 8 6 Common Channels 2-4 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-7 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater 99 Relay Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 1 or 2 channels • 1 2 3 4 5 6 7 8 PWR ON 1 2 STATUS /FAULT 13 14 15 16 114,5 22,5 General Description: The Switch/Proximity Detector Repeater type D1130 is a DIN Rail unit with one or two independent channels. The unit can be configured for contact or proximity detector, NO or NC and for NE or ND SPDT relay output contact. Each channel enables a Safe Area load to be controlled by a switch, or a proximity detector, located in Hazardous Area. D1130D dual channel type has two independent input channels and actuates the corresponding output relay. Two actuation modes can be independently DIP switch configured on each input channel: NO input/NE relay or NO input/ND relay. Contact or proximity sensor and its connection line short or open circuit fault detection is also DIP switch configurable: fault detection can be enabled (in case of fault it de-energizes the corresponding output relay and turns the fault LED on) or disabled (in case of fault the corresponding output relay repeats the input line open or closed status as configured). D1130S single channel type has one input channel and two output relays; the unit has two DIP switch configurable operating modes: Mode A) input channel actuates in parallel the two output relays (DPDT contact). Relay actuation mode can be independently configured for each output in two modes: NO input/NE relay or NO input/ND relay. Mode B) input channel actuates output relay A configurable in two modes as in mode A above. Output relay B operates as a fault output (in case of input fault, relay B actuates and the fault LED turns on while relay A repeats the input line as configured). Actuation can be DIP switch configured in two modes: No input fault/energized relay (it de-energizes in case of fault) or No input fault/de-energized relay (it energizes in case of fault). Function: 1 or 2 channels I.S. switch repeater for contact or EN60947-5-6 proximity. Provides 3 port isolation (input/output/supply). Signalling LEDs: Power supply indication (green), output status (yellow), line fault (red). Field Configurability: NO/NC input for contact/proximitor, NE/ND relay operation and fault detection enable/disable. Use in hazardous area according to instruction manuals Voltage Current consumption (mA) N° Vac, in short circuit, channels (@115 relays energized) Technical Data: • Supply: 115 - 230 Vac, 50-60 Hz nom (85 to 264 Vac, 48 to 400 Hz) or 100 to 350 Vdc, ripple within voltage limits ≤ 10 Vpp. Limit supply voltage to 250 Vrms for Instrinsic Safety applications • Isolation (Test Voltage): In S.I./Out 2,5 KV; In S.I./Supply 2,5 KV; Out/Supply 2,5 KV; Out/Out 2,5 KV • Input switching current levels: ON ≥ 2,1 mA, OFF ≤ 1,2 mA, switch current ≈ 1,65 mA ± 0,2 mA hysteresis • Fault current levels: open fault ≤ 0,2 mA, short fault ≥ 6,8 mA, (when enabled both faults de-energize channel relay with dual channel unit D1130D or actuate fault relay with single channel unit D1130S) • Input equivalent source: • Output: Contact material: Contact rating: Mechanical/Electrical life: Operate/Release time: Bounce time NO/NC contact: Response time: Frequency response: 8 V 1 KΩ typical (8 V no load, 8 mA short circuit) voltage free SPDT relay contact AgCdO 2A 250 Vac 500 VA, 2A 250 Vdc 80 W (resistive load) 30 * 106/1 * 105, typical 7/3 ms, typical 3/5 ms 20 ms maximum10 Hz • Environmental conditions: Operating: temperature limits -20 to + 60° C, relative humidity max 90% non condensing, up to 35° C Storage: temperature limits -45 to + 80° C • Mounting: Connection: T35 DIN Rail according to EN50022 by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to2,5 mm2 • Degree of protection: IP 20 • Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 2004/108/CE EMC Directive EMC: compatibility to EN61000-6-2, EN61000-6-4 Current consumption (mA) (@230 Vac, in short circuit, relays energized) Max power consumption (W) (@264 Vac, in short circuit, relays energized) Weight (g) ORDERING REFERENCES 85 - 230 V.a.c. 1 25 15 1,9 140 D1130S 85 - 230 V.a.c. 2 25 15 2 about 145 D1130D BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] E-7 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-8 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater Approvals: Safety parameters: II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, II 3G Ex nA IIC T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, [Ex iaD] associated electrical apparatus. Uo/Voc = 10,7 V, Io/Isc = 15 mA, Po/Po = 39 mW at terminals 13-14, 15-16. Um = 250 Vrms, -20 ° C ≤ Ta ≤ 60 ° C. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. MAXIMUM EXTERNAL PARAMETERS Group Co/Ca CENELEC (uF) IIC IIB IIA 2,23 15,60 69,00 Lo/La (mH) Lo/Ro (uH/ohm) Terminals 13-14, 15-16 172 689 1379 930 3720 7440 Uo/Voc = 10,7 V Io/Isc = 15 mA Po/Po = 39 mW DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN6007926 IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26, IEC61241-0, IEC61241-11, GM International CRR028 conforms to EN60079-0, EN60079-15, UL & C-UL E222308 conforms to UL913 (Div.1), UL 60079-0 (General, All Zones), UL60079-11 (Intrinsic Safety “i” Zones 0 & 1) for UL and CSA-C22.2 No.157-92 (Div.1), CSA-E60079-0 (General, All Zones), CSA-E60079-11 (Intrinsic Safety “i” Zones 0 & 1) for C-UL, FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, 3611, 3810 e C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15, Russia according to GOST 12.2.007.0-75, R 51330.0-99, R 51330.10-99 [Exia] IIC X, Ukraine according to GOST 12.2.007.0,22782.0,22782.5 Exia IIC X, DNV and KR Type Approval Certificate for marine applications. NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Connections HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL D1130D COMMON POSITIVE CONNECTION voltage free contact Proximity In 1 voltage free contact = + - 13 + - 15 = 14 Proximity In 2 = 16 3L 4N Supply 115-230 Vac 8 NC 2 NO 1 COM Out 1 7 NC 6 NO 5 COM Out 2 MODEL D1130S = voltage free contact In 1 Proximity + - 13 14 = = 3L 4N Supply 115-230 Vac 8 NC 2 NO 1 COM Out 1-A 7 NC 6 NO 5 COM Out 2-B Relay contact shown in de-energized position E-8 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-9 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Proximity Detector Repeater for analogue input 99 Analogue Output for DIN-Rail • Input from Zone 0 (Zone 20), installation in Zone 2 • 1 or 2 channels, input 4 - 20 mA • 1 2 3 4 5 6 7 8 PWR ON 9 10 11 12 13 14 15 16 114,5 22,5 General Description: The single and dual channel DIN Rail Repeater Power Supply, D1010S and D1010D, provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA transmitters, or separately powered 3, 4 wires 4-20, 0-20 mA transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The circuit allows bi-directional communication signals, for HartSmart transmitters. Function: 1 or 2 channels I.S. analog input for 2 wires loop powered or separately powered Smart transmitters, provides 3 port isolation (input/output/supply) and current (source or sink) or voltage output signal. Technical Data: • Supply: 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp • Isolation (Test Voltage): In S.I./Out 1,5 KV; In S.I./Supply 1,5 KV In S.I./In S.I. 500 V; Out/Supply 500 V; Out/Out 500 V • Input: 0/4 to 20 mA (separately powered input, voltage drop ≤ 0,9 V) or 4 to 20 mA (2 wire Tx current limited at ≈ 25 mA) Signalling LED: Power supply indication (green). Field Configurability: mA (source or sink) or V output signal. • Transmitter line voltage: ≥ 15 V at 20 mA with max. 20 mVrms ripple on 0,5 at 40 KHz frequency band Smart Communication Frequency Band: 0,5 to 40 KHz within 3 dB (Hart and higher frequency protocols). • Output: 0/4 at 20 mA, on max 600 Ω load in source mode; V min. 5 V with 0 Ω load V max. 30 V in sink mode, current limited at ≈ 23 mA or 0/1 to 5 V on internal 250 Ω shunt (or 0/2 to 10 V on internal 500 Ω shunt on request) • Environmental conditions: Operating: temperature limits -20 to + 60° C, relative humidity max 90% non condensing, up to 35° C Storage: temperature limits -45 to + 80° C • Mounting: Connection: T35 DIN Rail according to EN50022 by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to2,5 mm2 Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. • Degree of protection: IP 20 • Compatibility: CE mark compliant, conforms to 94/9/EC Atex Directive and to 2004/108/CE EMC Directive EMC: compatibility to EN61000-6-2, EN61000-6-4 Use in hazardous area according to instruction manuals Voltage N° channels Current consumption (mA) (@24 Vdc, output 20 mA, typical) Power dissipation (W) (@24 Vdc, output 20 mA, typical) Max power consumption (W) (@30 Vdc, in short circuit) Weight (g) ORDERING REFERENCES 24 V.d.c. 1 60 1 2 125 D1010S 24 V.d.c. 2 115 1,9 3,7 about 175 D1010D BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] E-9 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-10 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Proximity Detector Repeater for analogue input Approvals: Safety parameters: II (1) G [Ex ia] IIC, II (1) D [Ex iaD], I (M2) [Ex ia] I, II 3G Ex nA II T4, [Zone 0] [Ex ia] IIC, [Ex ia] I, [Ex iaD] associated electrical apparatus. Uo/Voc = 26,3 V, Io/Isc = 91 mA, Po/Po = 579 mW at terminals 14-15, 10-11. Uo/Voc = 1,1 V, Io/Isc = 38 mA, Po/Po = 11 mW at terminals 15-16, 11-12. Ui/Vmax = 30 V, Ii/Imax = 104 mA, Ci = 1,05 nF, Li = 0 nH at terminals 15-16,11-12 Um = 250 Vrms, -20 ° C ≤ Ta ≤ 60 ° C. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. MAXIMUM EXTERNAL PARAMETERS Lo/La (mH) Lo/Ro (uH/ohm) Terminals 14-15, 10-11 0,095 0,738 2,508 4,3 17,2 34,5 59,6 238,4 476,8 Uo/Voc = 26,3 V Io/Isc = 91 mA Po/Po = 597 mW Group Co/Ca CENELEC (uF) Lo/La (mH) Lo/Ro (uH/ohm) Terminals 15-16, 11-12 11,3 45,3 90,7 3490 13963 27927 Uo/Voc = 1,1 V Io/Isc = 38 mA Po/Po = 11 mW Group Co/Ca CENELEC (uF) IIC IIB IIA IIC IIB IIA 100 1000 1000 DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN6007926 IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26, IEC61241-0, IEC61241-11, IMQ 09 ATEX 013X conforms to EN60079-0, EN60079-15, UL & C-UL E222308 conforms to UL913 (Div.1), UL 60079-0 (General, All Zones), UL60079-11 (Intrinsic Safety “i” Zone 0 & 1), UL60079-15 (“n” Zone 2) UL 1604 (Div. 2) for UL and CSA-C22.2 No.157-92 (Div.1), CSA-E60079-0 (General, All Zones), CSA-E60079-11 (Intrinsic Safety “i” Zones 0 & 1) for C-UL, CSA-C22.2 No. 213-M1987 (div. 2) and CSA-E60079-15 (“n” Zone 2) for C-UL, FM & FM-C No. 3024643, 3029921C, conforms to 3600, 3610, 3611, 3810 and C22.2 No.142, C22.2 No.157, C22.2 No.213, E600790, E60079-11, E60079-15, Russia according to GOST 12.2.007.0-75, R 51330.0-99, R 51330.10-99 [Exia] IIC X, Ukraine according to GOST 12.2.007.0,22782.0,22782.5 Exia IIC X, TUV Certificate no. C-IS-183645-01, SIL 2/SIL 3 according to ISEC 61508. Please refer to Functional Safety Manual for SIL applications. DNV and KR Type Approval Certificate for marine applications. NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Connections HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 MODEL D1010D = In 1 External Powered Tx + - 2 Wire Tx + HHT - 14 15 16 = = = In 2 External Powered Tx + - 2 Wire Tx + HHT - 10 11 12 = = 3 + Supply 24 Vdc Out 1 4Source I Source V HHT + + Sink I 1 mA RL + + V 2 mA 8 - = Out 2 = HHT 5 6 7 = = Source I + - mA RL Source V + - V + - Sink I mA + MODEL D1010S = In 1 External Powered Tx + - 2 Wire Tx + - HHT 14 15 16 = = 3 + Supply 24 Vdc 4HHT = = 1 2 8 Source I + - mA RL Out 1 Source V + - V + - Sink I mA + Relay contact shown in de-energized position E-10 BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina E-11 AMPLIFIERS AND REPEATERS FOR ATEX SENSORS - Switch/Proximity Detector Repeater HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 Safety Description Connections for Duplication of Active Input Signals Terminals 15 -12 Uo/Voc = 2,2 V Io/Isc = 38 mA Po/Po = 21 mW Restriction on specifications for external powered Transmitter: The voltage drop must be changed in 1,8 V maximum The safety parameters must be changed in: Uo/Voc = 2,2 V, Io/Isc = 38 mA, Po/Po = 21 mW Group CENELEC Co/Ca (μF) Lo/La (mH) Lo/Ro (μH/Ω) IIC IIB IIA 100 1000 1000 11,3 45,3 90,7 849 3396 6793 MODEL D1010D Duplicator = External Powered Tx + In 1 14 15 16 - = = = 10 11 12 = = 3 + Supply 24 Vdc Out 1-A 4Source I Source V HHT + + Sink I 1 mA RL + + V 2 mA 8 - = Out 1-B = HHT 5 6 7 = = Source I + - mA RL Source V + - V + - Sink I mA + Relay contact shown in de-energized position Safety Description Connections for Duplication of 2 wires Transmitter Input Terminals 14 -11 Uo/Voc = 27,4 V Io/Isc = 91 mA Po/Po = 624 mW Restriction on specifications for 2 wires Transmitter Input: Bidirectional communication for Smart Transmitter is provided only on channel 1 The minimum supply voltage available for Transmitter (Vtx) is 14,1 V at 20 mA input The safety parameters must be changed in: Uo/Voc = 27,4 V, Io/Isc = 91 mA, Po/Po = 624 mW Group CENELEC Co/Ca (μF) Lo/La (mH) Lo/Ro (μH/Ω) IIC IIB IIA 0,085 0,675 2,258 4,3 17,2 34,5 54,7 218,9 437,9 MODEL D1010D Duplicator = In 1 2 Wire Tx + - = = HHT 14 15 16 = = = 10 11 12 = = 3 + Supply 24 Vdc Out 1-A 4Source I Source V HHT + + Sink I 1 mA RL + + V 2 mA 8 - = Out 1-B = HHT 5 6 7 Source I + - mA RL Source V + - V + - Sink I mA + Relay contact shown in de-energized position BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] E-11 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina F-1 MALE CONNECTORS PREASSEMBLED ON SENSORS General informations: This section presents sensors already cabled to male connectors for particular applications. Specific cable lengths are available upon request on all the products. BDC versions with rotating nut allow the direct connection to the connection boxes reducing the costs and improving the reliability of the plant. Other solutions with different products are possible according to customer specification. The suggested connectors have to be matched to the sensors according to the cable sections, indicated on the ordering references tables inside the catalogue. HOW TO COMPOSE THE ORDERING REFERENCES Type DCA 12 / 4 H 0 9 KS3GD - 0,3 Cable lenght (m) Dimensions H 50 Ø14,5 18 M12 x 1 13 Ø 10,5 Type SW14 Manufacturer Series Degree of protection Suitable for cables diameter (mm) BDC M12 x 1 rotating nut IP68 5 2 3 1 4 Note: more detailed technical data are available on specific manufacturers data sheets. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] F-1 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-1 HOW TO INTERPRETE THE ORDERING REFERENCES CONNECTORS MOULDED WITH CABLE N° Connector: C 8B 9 9B 10 10 / = right angled female M12 x 1 for d.c. sensors = straight male M12 x 1 for d.c. sensors = right angled male M12 x 1 for d.c. sensors = straight female M12 x 1 for d.c. sensors 0 0 3 N° conductors: 2 3 4 5 = 2 wires = 3 wires = 4 wires = 5 wires Cable length m. 2 5 10 = 2 m. = 5 m. = 10 m. Cable material: PV PR T = PVC (blue for 1GD; grey for 3GD) = PUR (blue for 1GD; black for 3GD) = Thermoplastic grey rubber (-40° ÷ + 140° C) Atex Versions: A 3GD = Category 1G-1D = Category 3G-3D 2 PV A Note: When using female connectors, please consider an insertion length inside the sensor, which is: M12 connectors I.E. = 8 mm Sensor DCA8/4309KS3GD total length = 60 mm Connector C8B/0032PV3GD total length = 29 mm Overall dimension sensor + connector = (60 + 29) - 8 = 81 mm. BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] G-1 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-3 FEMALE CONNECTORS M12 x 1 For ATEX sensors Degree of protection IP68 - Straight in d.c. Moulded with cable According to 94/9/CE - EN60079-0 - EN 60947-5-2 • • • • Connector 10A 13 Ø 10,5 44 Ø14,5 12 M12 x 1 2 1 SW14 3 4 General features: Female connectors of this section can be matched to the BDC ATEX proximity sensors according to the category as indicated on the table below. They must be separately ordered. The 2-wire model is suitable for NAMUR sensors either on N.O. or N.C. version. It is possible to use it in zone 0 or 20 without additional protection against electrostatic charges. Particular moulding processes assure the maximum sealing, making these products suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Technical data: • Operating voltage: • Maximum current: • Contact resistance: • Contacts: • Locking nut: • Temperature range • Degree of protection: max 50 Vac/75 Vdc 4A ≤ 5 mΩ CuZn, brass pre-nickeled and gold plated (0,8 μm) self-locking in CuZn, nickel plated brass for PUR and PVC versions: - 25° ÷ + 90°C for HT versions: - 40° ÷ + 120°C IP68 with plug in fully locked position * = HT, thermoplastic rubber - 40° ÷ + 140°C 1G -1D 3G - 3D 3G - 3D Zone 0 -20 2 - 22 2 - 22 Cap. cable pF/m 140 170 170 Indutt. cable μH/m 0,4 0,8 0,8 Cable 2-wires (blue) 3-wires (grey) 4-wires (grey) Section 2 x 0,75 mm2 - ø ext. 5 3 x 0,50 mm2 - ø ext. 5 4 x 0,35 mm2 - ø ext. 5 Lenght m. 10A 10A 10A 10A 10A 10A 10A 10A 10A Category Material Connector n° ORDERING REFERENCES PVC PVC PVC PUR PUR PUR HT* HT* HT* 2 5 10 2 5 10 2 5 10 1 2 4 brown + blue _ C10/0022PVA C10/0025PVA C10/00210PVA C10/0022PRA C10/0025PRA C10/00210PRA - 1 4 3 brown black blue + output - C10/0032PV3GD C10/0035PV3GD C10/00310PV3GD C10/0032PR3GD C10/0035PR3GD C10/00310PR3GD C10/0032T3GD C10/0035T3GD C10/00310T3GD 1 4 2 3 brown black white blue + output NO output NC _ C10/0042PV3GD C10/0045PV3GD C10/00410PV3GD C10/0042PR3GD C10/0045PR3GD C10/00410PR3GD C10/0042T3GD C10/0045T3GD C10/00410T3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] G-3 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-4 FEMALE CONNECTORS M12 x 1 • • • • For ATEX sensors Right angled in d.c. - Degree of protection IP68 Moulded with cable According to 94/9/CE - EN60079-0 - EN60947-5-2 Connector 8A 29 SW14 12 Ø14,5 2 M12 x 1 1 38,5 7,3 3 4 17 Ø 10,5 General features: Female connectors of this section can be matched to the BDC ATEX proximity sensors according to the category as indicated on the table below. They must be separately ordered. The 2-wire model is suitable for NAMUR sensors either on N.O. or N.C. version. It is possible to use it in zone 1 or 21 without additional protection against electrostatic charges. Particular moulding processes assure the maximum sealing, making these products suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Technical data: • Operating voltage: • Maximum current: • Contact resistance: • Contacts: • Locking nut: • Temperature range • Degree of protection: max 50 Vac/75 Vdc 4A ≤ 5 mΩ CuZn, brass pre-nickeled and gold plated (0,8 μm) self-locking in CuZn, nickel plated brass for PUR and PVC versions: - 25° ÷ + 90°C For HT versions: - 40° ÷ + 120°C IP68 with plug in fully locked position * = HT, thermoplastic - 40° ÷ + 140°C G-4 2G -2D 3G - 3D 3G - 3D Zone 1 - 21 2 - 22 2 - 22 Cap. cable pF/m 140 170 170 Indutt. cable μH/m 0,4 0,8 0,8 Cable 2-wires (blue) 3-wires (grey) 4-wires (grey) Section 2 x 0,75 mm2 - ø ext. 5 3 x 0,50 mm2 - ø ext. 5 4 x 0,35 mm2 - ø ext. 5 Lenght m. 8A 8A 8A 8A 8A 8A 8A 8A 8A Category Material Connector n° ORDERING REFERENCES PVC PVC PVC PUR PUR PUR HT* HT* HT* 2 5 10 2 5 10 2 5 10 1 2 4 brown + blue _ C8B/0022PVA C8B/0025PVA C8B/00210PVA C8B/0022PRA C8B/0025PRA C8B/00210PRA - 1 4 3 brown black blue + output - C8B/0032PV3GD C8B/0035PV3GD C8B/00310PV3GD C8B/0032PR3GD C8B/0035PR3GD C8B/00310PR3GD C8B/0032T3GD C8B/0035T3GD C8B/00310T3GD 1 4 2 3 brown black white blue + output NO output NC _ C8B/0042PV3GD C8B/0045PV3GD C8B/00410PV3GD C8B/0042PR3GD C8B/0045PR3GD C8B/00410PR3GD C8B/0042T3GD C8B/0045T3GD C8B/00410T3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-5 MALE CONNECTORS M12 x 1 For ATEX applications • Straight in d.c. • Moulded with cable • According to 94/9/CE - EN60079-0 - EN 60947-5-2 • Connector 9A 50 13 Ø14,5 Ø 10,5 18 M12 x 1 SW14 2 3 1 4 General features: Particular moulding processes assure the maximum sealing, making these products suitable even for heavy applications. Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Technical data: • Operating voltage: • Maximum current: • Contact resistance: • Contacts: • Locking nut: • Temperature range: • Degree of protection: max 50 Vac/75 Vdc 4A ≤ 5 mΩ CuZn, brass pre-nickeled and gold plated (0,8 μm) self-locking in CuZn, nickel plated brass - 25° ÷ + 90°C IP68 with plug in fully locked position 3G - 3D 3G - 3D Zone 2 - 22 2 - 22 Cap. cable pF/m 170 170 Indutt. cable μH/m 0,8 0,8 Cable 3-wires (grey) 4-wires (grey) Section 3 x 0,50 mm2 - ø ext. 5 4 x 0,35 mm2 - ø ext. 5 Lenght m. 9A 9A 9A 9A 9A 9A Category Material Connector n° ORDERING REFERENCES PVC PVC PVC PUR PUR PUR 2 5 10 2 5 10 1 4 3 brown black blue + output - C9/0032PV3GD C9/0035PV3GD C9/00310PV3GD C9/0032PR3GD C9/0035PR3GD C9/00310PR3GD 1 4 2 3 brown black white blue + output NO output NC _ C9/0042PV3GD C9/0045PV3GD C9/00410PV3GD C9/0042PR3GD C9/0045PR3GD C9/00410PR3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] G-5 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina G-6 MALE CONNECTORS M12 x 1 • • • • For ATEX applications Right angled in d.c. - Degree of protection IP68 Moulded with cable According to 94/9/CE - EN60079-0 - EN60947-5-2 Connector 9C 35 SW14 18 Ø14,5 2 3 38,5 M12 x 1 SW14 1 4 17 Ø 10,5 General features: Note: use in hazardous area must be according to the instruction manual supplied together the sensors. Technical data: • Operating voltage: • Maximum current: • Contact resistance: • Contacts: • Locking nut: • Temperature range: • Degree of protection: max 50 Vac/75 Vdc 4A ≤ 5 mΩ CuZn, brass pre-nickeled and gold plated (0,8 μm) self-locking in CuZn, nickel plated brass - 25° ÷ + 90°C IP68 with plug in fully locked position G-6 3G - 3D 3G - 3D Zone 2 - 22 2 - 22 Cap. cable pF/m 170 170 Indutt. cable μH/m 0,8 0,8 Cable 3-wires (grey) 4-wires (grey) Section 3 x 0,50 mm2 - ø ext. 5 4 x 0,35 mm2 - ø ext. 5 Lenght m. 9C 9C 9C 9C 9C 9C Category Material Connector n° ORDERING REFERENCES PVC PVC PVC PUR PUR PUR 2 5 10 2 5 10 1 4 3 brown black blue + output - C9B/0032PV3GD C9B/0035PV3GD C9B/00310PV3GD C9B/0032PR3GD C9B/0035PR3GD C9B/00310PR3GD 1 4 2 3 brown black white blue + output NO output NC _ C9B/0042PV3GD C9B/0045PV3GD C9B/00410PV3GD C9B/0042PR3GD C9B/0045PR3GD C9B/00410PR3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-1 HOW TO INTERPRETE THE ORDERING REFERENCES MOULDED CONNECTING CABLES FOR ATEX SENSORS C9 / C10 N° Male connector: 9 9B = straight M12 x 1 = right angled M12 x 1 N° Female connector: 8B 10 = right angled M12 x 1 = straight M12 x 1 / 00 00 = without LED N° conductors: 2 3 4 = 2 wires = 3 wires = 4 wires Cable length 0,6 1 2 Other cable Cable material: PV PR = PVC = PUR Category: A 3GD = 1G-1D or 2G-2D = 3G-3D 2 - 0,6 PV A = 0,6 m =1m =2m lengths upon request BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] H-1 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-3 MOULDED CONNECTING CABLES FOR ATEX SENSORS MALE M12 x 1 straight • FEMALE M12 x 1 • According to 94/9CE - EN60079-0 - EN60947-5-2 • C9/C10/… 44 50 18 13 Ø 10,5 Ø 10,5 13 12 Ø14,5 Ø14,5 M12 x 1 SW14 SW14 2 2 wires version 1 1 4 3 4 3 wires version 1 1 3 4 4 2 3 M12 x 1 2 2 4 wires version 1 1 4 3 4 C9/C8B/… M12 x 1 50 18 13 7,3 Ø 10,5 Ø 10,5 Ø 14,5 12 29 Ø 14,5 M12 x 1 17 SW14 38,5 2 2 2 wires version 1 1 4 3 wires version 1 3 1 4 2 2 4 wires version 1 1 4 • Operating voltage max 50 Vac/75 Vdc • Maximum current: 4A • Contact resistance: ≤ 5 mΩ • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 μm) • Moulding: PUR • Locking nut: self-locking in CuZn, nickel plated brass • Temperature range: - 25 ÷ + 90°C • Degree of protection: IP68 with plug in fully locked position 3 4 3 Technical data: 4 3 4 Note: use in hazardous area must be according to the instruction manual supplied together the sensors. ORDERING REFERENCES Category 1G - 1D 2G - 2D 3G - 3D 3G - 3D Zone 0 - 20 1 - 21 2 - 22 2 - 22 Cap.cable pf/m 140 170 170 Indutt. cable uH/m 0,4 0,8 0,8 3-wires (grey) 4-wires (grey) 3 x 0,50 mm2 - ø ext. 5 4 x 0,35 mm2 - ø ext. 5 Lenght m. 2-wires (blue) 2 x 0,75 mm2 - ø ext. 5 Material Cable Section PVC PVC PVC PUR PUR PUR 0,6 1 2 0,6 1 2 1 2 4 brown + blue _ • Male straight • Female straight • Male straight • Female right angled C9/C10/002-0,6PVA C9/C10/002-1PVA C9/C10/002-2PVA C9/C10/002-0,6PRA C9/C10/002-1PRA C9/C10/002-2PRA C9/C8B/002-0,6PVA C9/C8B/002-1PVA C9/C8B/002-2PVA C9/C8B/002-0,6PRA C9/C8B/002-1PRA C9/C8B/002-2PRA 1 4 3 brown black blue • Male straight • Female straight C9/C10/003-0,6PV3GD C9/C10/003-1PV3GD C9/C10/003-2PV3GD C9/C10/003-0,6PR3GD C9/C10/003-1PR3GD C9/C10/003-2PR3GD + output - • Male straight • Female right angled C9/C8B/003-0,6PV3GD C9/C8B/003-1PV3GD C9/C8B/003-2PV3GD C9/C8B/003-0,6PR3GD C9/C8B/003-1PR3GD C9/C8B/003-2PR3GD 1 4 2 3 brown black white blue • Male straight • Female straight C9/C10/004-0,6PV3GD C9/C10/004-1PV3GD C9/C10/004-2PV3GD C9/C10/004-0,6PR3GD C9/C10/004-1PR3GD C9/C10/004-2PR3GD + output NO output NC _ • Male straight • Female right angled C9/C8B/004-0,6PV3GD C9/C8B/004-1PV3GD C9/C8B/004-2PV3GD C9/C8B/004-0,6PR3GD C9/C8B/004-1PR3GD C9/C8B/004-2PR3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] H-3 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-4 MOULDED CONNECTING CABLES FOR ATEX SENSORS • MALE M12 x 1 right angled • FEMALE M12 x 1 • According to 94/9/CE - EN60079-0 - EN 60947-5-2 C9B/C10/… Ø14,5 M12 x 1 SW14 18 17 35 Ø 10,5 Ø 10,5 44 13 12 Ø 14,5 38,5 SW14 2 2 wires version 1 2 M12 x 1 1 4 4 3 3 wires version 1 1 3 4 4 2 2 3 4 wires version 1 1 4 3 4 C9B/C8B/… Ø14,5 M12 x 1 M12 x 1 SW14 18 17 35 7,3 Ø 10,5 Ø 10,5 Ø 14,5 12 29 17 38,5 38,5 2 2 wires version 1 • Operating voltage max 50 Vac/75 Vdc • Maximum current: 4A • Contact resistance: ≤ 5 mΩ • Contacts: CuZn, brass pre-nickeled and gold plated (0,8 μm) • Moulding: PUR • Locking nut: self-locking in CuZn, nickel plated brass • Temperature range: - 25 ÷ + 90°C • Degree of protection: IP68 with plug in fully locked position 4 3 wires version 1 1 3 4 4 2 2 3 Technical data: 1 4 3 2 4 wires version 1 1 4 3 4 Note: use in hazardous area must be according to the instruction manual supplied together the sensors. ORDERING REFERENCES Category 2G - 2D 3G - 3D 3G - 3D Zone 1 - 21 2 - 22 2 - 22 Cap.cable pf/m 140 170 170 Indutt. cable uH/m 0,4 0,8 0,8 3-wires (grey) 4-wires (grey) 3 x 0,50 mm2 - ø ext. 5 4 x 0,35 mm2 - ø ext. 5 Lenght m. 2-wires (blue) 2 x 0,75 mm2 - ø ext. 5 Material Cable Section PVC PVC PVC PUR PUR PUR 0,6 1 2 0,6 1 2 H-4 1 2 4 • Male straight • Female straight C9B/C10/002-0,6PVA C9B/C10/002-1PVA C9B/C10/002-2PVA C9B/C10/002-0,6PRA C9B/C10/002-1PRA C9B/C10/002-2PRA brown + blue _ 1 4 3 brown black blue + output - • Male straight • Female right angled • Male straight • Female straight • Male straight • Female right angled C9B/C8B/002-0,6PVA C9B/C8B/002-1PVA C9B/C8B/002-2PVA C9B/C8B/002-0,6PRA C9B/C8B/002-1PRA C9B/C8B/002-2PRA C9B/C10/003-0,6PV3GD C9B/C10/003-1PV3GD C9B/C10/003-2PV3GD C9B/C10/003-0,6PR3GD C9B/C10/003-1PR3GD C9B/C10/003-2PR3GD C9B/C8B/003-0,6PV3GD C9B/C8B/003-1PV3GD C9B/C8B/003-2PV3GD C9B/C8B/003-0,6PR3GD C9B/C8B/003-1PR3GD C9B/C8B/003-2PR3GD 1 4 2 3 brown black white blue • Male straight • Female straight C9B/C10/004-0,6PV3GD C9B/C10/004-1PV3GD C9B/C10/004-2PV3GD C9B/C10/004-0,6PR3GD C9B/C10/004-1PR3GD C9B/C10/004-2PR3GD + output NO output NC _ • Male straight • Female right angled C9B/C8B/004-0,6PV3GD C9B/C8B/004-1PV3GD C9B/C8B/004-2PV3GD C9B/C8B/004-0,6PR3GD C9B/C8B/004-1PR3GD C9B/C8B/004-2PR3GD BDC Electronic - Viale Lidice, 37/39 - 10095 Grugliasco (To) - Italy -Tel. (+39)011.31.49.021/022 Fax (+39) 011.31.49.023 - www.bdcelectronic.com - E-mail:[email protected] Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-5 NOTES Catalogo Atex 2013 Inglese_03 NOTES 11-04-2013 9:53 Pagina H-6 Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-7 NOTES Catalogo Atex 2013 Inglese_03 11-04-2013 9:53 Pagina H-8 The physical appearance of the actual devices may be different from the illustrations shown. BDC Electronic srl advises that the descriptions and subjects of the catalogue may be changed without notice. Copy and imitation of this catalogue are strictly forbidden by copyright laws. Printed in November 2012 Design by Prandi Image - Torino - Italy Pictures by Prandi Image - Torino - Italy
Benzer belgeler
Catalogo Completo
Female connectors of this section can be matched to the proximity sensors as indicated on the ordering references tables of the products. They must be separately ordered. Particular moulding proces...
pdf indir - Emit Metal
In these conditions, cables like 2x2,5 – 3x2,5 – 4x4 – 4x6 - 4x10 - 4x16 can be used in minimum.
According to 3a standart dimensions, the height of Underoor Cable Trays are 25mm in
minimum and 35m...
SAtIŞ SONrASI HİZMetLer
ve hizmetleri geniş bir yelpazede sunuyor. Tasarım ve geliştirmeden üretim, montaj ve son kontrole kadar bir ürünün tüm
yaşam döngüsü boyunca ölçüm bilgisi işleyişi ile müşterilerimizi destekliyoru...