1. fire control panels
Transkript
1. fire control panels
2 0 P R O D U C T C A T A L O G U E 06 The Group www.detectomat.com contents page 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 fire control panels detect 3004 fire control panel and accessories ...............................................................................................................4-11 detect 3016 fire control panel and accessories .............................................................................................................12-17 detect 3004/3016 panel accessories ............................................................................................................................18-23 network components ....................................................................................................................................................24-28 programming tools and software ...................................................................................................................................29-30 visualization .................................................................................................................................................................31-32 conventional panels ...........................................................................................................................................................32 2. 2.1 2.2 2.3 detectors loop3000 – adressable detectors..................................................................................................................................33-39 CT 3000 – conventional detectors .................................................................................................................................39-42 detector accessoires.....................................................................................................................................................43-48 3. 3.1 3.2 3.3 manual call points loop3000 – addressable manual call points ..................................................................................................................49-52 CT 3000 – conventional call points ...............................................................................................................................52-54 accessoires for manual call points......................................................................................................................................55 4. loop3000 modules ......................................................................................................................................................56-58 5. loop3000 – radio extension ........................................................................................................................................59-61 6. 6.1 6.2 6.3 6.4 6.5 6.6 special detectors aspiration smoke detectors ...........................................................................................................................................62-65 accessoires smoke detectors ........................................................................................................................................66-69 infrared beam detectors................................................................................................................................................70-71 sensor cable detectors .......................................................................................................................................................72 flame detectors ............................................................................................................................................................73-75 intrisically safe detectors ..............................................................................................................................................75-78 7. home smoke detectors ...............................................................................................................................................79-82 8. 8.1 8.2 signalling devices signalling devices for loop3000 ....................................................................................................................................83-85 conventional signalling devices .....................................................................................................................................85-90 9. door magnets and accessoires...................................................................................................................................91-95 10. detector testing devices .............................................................................................................................................96-97 11. Article index .............................................................................................................................................................98-103 12. Terms & Conditions of Sale detectomat GmbH .......................................................................................................104-106 Produktaktualisierungen finden Sie laufend unter www.detectomat.de Stand August 2006 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 31973 fire control panel detect 3004 • • • • • • • • • • • • • • • • • 2 slots for fire brigade and network interface 128 programmable detector zones up to 4 x 126 loop3000 components up to 16 inputs for conventional detector zones maximum loop length 3.000 m (using installation cable IY(St)Y 2 x 0,8 mm) monitored loop operation with detection system loop3000 facility for integration of fire brigade interface, display panel, transmission- and key-depot adapter interface 3 potential-free relay outputs (250 V / 5 A) 9 open collector outputs (30 V / 90 mA) monitored signal transmitter 400 mA 2 RS 232 interfaces for personal computer, printer, modem, building management system network compatible via bitbus interface up to 32 fire control panels controls or additional 63 bitbus components operation and event memory for 500 messages (first in first out principle) possibility via mounting panel to integrate a protocol-printer and LED indicator modules for zone alarm and zone fault indication option to equip a redundant main board processor (second CPU) power supply 72 W and monitored battery condition storing space for two batteries 12 V / 26 Ah technical specification input voltage frequency operation voltage power supply emergency power quiesent current alarm current interfaces display zone LED´s sounder output external user output relay output open collector output operation temperature humidity protection class housing color front color material weight dimensions (H x W x D) approvals Microprocessor controlled modular fire control panel DIN EN 54, VDE 0833 and VdS approved. For use with the loop3000 fire detection system components. • • • display- and control panel DIN EN 54 part 2 4 alphanumeric lines LCD- display with backlight 2 slots for detector interface boards (max. to equip up to 4 loops or 16 conventional fire zones) complies with 230 V AC (-15 % / +10%) 50 / 60 Hz 21,0 up to 29,2 V DC 72 W max. 2 x 12 V / 26 Ah 86 mA 146 mA 2 x RS 232/422 Bitbus (option) LCD 4 x 20 characters poss. for up to 48 zone indicators 24 V DC / 400 mA monitored 24 V DC / 800 mA 3 change over 250 V / 5 A 9 open collector 30 V DC / 90 mA -5°C up to +40°C up to 95 % IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 12,5 kg 490 mm x 420 mm x 210 mm VdS: G 203068, S 295054, LPCB, GOST, Hungary, Bulgaria, Lithuania, Czech Republik, Ukrain, Slovakia, Slovenia, Spain, Switzerland, Belgium EN 54 - 2 remarks: if you use a printer 30106 you can use only 18 ah- or smaller batteries 4 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 31972 fire control panel shallow detect 3004 - shallow • • • • • • • • • • • • • • • • • • 2 slots for fire brigade and network interface 128 programmable detector zones up to 4 x 126 loop3000 components up to 16 inputs for conventional detector zones maximum loop length 3.000 m (using installation cable IY(St)Y 2 x 0,8 mm) monitored loop operation with detection system loop3000 facility for integration of fire brigade interface, display panel, transmission- and key-depot adapter interface 3 potential-free relay outputs (250 V / 5 A) 9 open collector outputs (30 V / 90 mA) monitored signal transmitter 400 mA additional external output 24V / 800mA 2 RS 232 interfaces for personal computer, printer, modem, building management system network compatible via bitbus interface up to 32 fire control panels or additional 63 bitbus components operation and event memory for 500 messages (first in first out principle) possibility via mounting panel to integrate a protocol-printer and LED indicator modules for zone alarm and zone fault indication option to equip a redundant main board processor (second CPU) power supply 72 W and monitored battery condition storing space for two batteries 12 V / 12 Ah technical specification input voltage frequency operation voltage power supply emergency power quiesent current alarm current interfaces display zone LED´s sounder output external user output relay output open collector output operation temperature humidity protection class housing color front color material weight dimensions (H x W x D) approvals Microprocessor controlled modular fire control panel, shallow version, DIN EN 54, VDE 0833 and VdS approved. For use with the loop3000 fire detection system components. complies with • • • display- and control panel DIN EN 54 part 2 4 alphanumeric lines LCD- display with backlight 2 slots for detector interface boards (max. to equip up to 4 loops or 16 conventional fire zones) 230 V AC (-15 % / +10%) 50 / 60 Hz 21,0 up to 29,2 V DC 72 W max. 2 x 12 V / 26 Ah 86 mA 146 mA 2 x RS 232/422 Bitbus (option) LCD 4 x 20 characters poss. for up to 48 zone indicators 24 V DC / 400 mA monitored 24 V DC / 800 mA 3 change over 250 V / 5 A 9 open collector 30 V DC / 90 mA -5°C up to +40°C up to 95 % IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 12,5 kg 490 mm x 420 mm x 150 mm VdS: S 295054, LPCB, GOST, Hungary, Bulgaria, Lithuania, Czech Republik, Ukrain, Slovakia, Slovenia, Spain, Switzerland, Belgium EN 54 - 2 remarks: usable as master remote and control panel in a network with the language kit LK ABF, this version of the remote and control panel offers space for LED indicators, printer, separate power supply etc 5 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 32049 fire control panel 19" rack mount detect 3004-19" • • • • • network compatible via bitbus interface up to 32 fire panel controls or additional 63 bitbus components operation and event memory for 500 messages (first in first out principle) suitable for 19" rack mount option to equip a redundant main board processor (second CPU) power supply 72 W and monitored battery condition technical specification Microprocessor controlled modular fire control panel, 19" rack mount version, DIN EN 54, VDE 0833 and VdS approved. For use with the loop3000 fire detection system components. • • • display- and control panel DIN EN 54 part 2 4 alphanumeric lines LCD- display with backlight 2 slots for detector interface boards (max. to equip up to 4 loops or 16 conventional fire zones) 2 slots for fire brigade and network interface 128 programmable detector zones up to 4 x 126 loop3000 components up to 16 inputs for conventional detector zones maximum loop length 3.000 m (using installation cable IY(St)Y 2 x 0,8 mm) monitored loop operation with detection system loop3000 possibility for integration of fire brigade interface, display panel, transmission- and key-depot adapter interface 3 potential-free relay outputs (250 V / 5 A) 9 open collector outputs (30 V / 90 mA) monitored signal transmitter 400 mA additional external output 24V / 800mA 2 RS 232 interfaces for personal computer, printer, modem, building management system • • • • • • • • • • • • art. 31974 language kit German language kit integrates German software, German description, German labelling art. 31975 language kit English language kit integrates English software, English description, English labelling, additional languages available on request input voltage frequency operation voltage power supply emergency power quiesent current alarm current interfaces display zone LED´s sounder output external user output relay output open collector output operation temperature humidity protection class front color dimensions (H x W x D) approvals complies with 230 V AC (-15 % / +10 %) 50 / 60 Hz 21,0 up to 29,2 V DC 72 W max. 2 x 12 V / 26 Ah 86 mA 146 mA 2 x RS 232/422 Bitbus (option) LCD 4 x 20 characters poss. for up to 48 zone indicators 24 V DC / 400 mA monitored 24 V DC / 800 mA 3 change over 250 V / 5 A 9 open collector 30 V DC / 90 mA -5°C up to +40°C up to 95 % IP 30 tele grey, RAL 7046 6HE x 19" x 150 mm VdS: G 203068, S 295054, LPCB, GOST, Hungary, Bulgaria, Lithuania, Czech Republik, Ukrain, Slovakia, Slovenia, Spain, Switzerland, Belgium EN 54 - 2 remarks: • the panel is designed to be mounted in a 19"- rack • the power pack is separately mounted in the 19"- rack • additional space is required for battery storage LK 3004 D remarks: it is essential to specify the language kit when ordering LK 3004 GB remarks: it is essential to specify the language kit when ordering 6 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 31817 1-loop interface DLI 3240 X1-1L • • • • • • • • • maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm) all loop3000 components can be addressed automatically manual addressable with EasyCheck 3000 (31482) two - wire - loop 8 freely programmable open collector outputs 3 open collector outputs 30 V DC / 90 mA for alarm and fault loop voltage 32 V DC, loop current 100 mA RS 232 interface for additional data monitoring slot for optional redundant processor technical specification operation voltage quiesent current alarm current interfaces open collector output operation temperature weight dimensions (H x W x D) picture similar to plug in to the detect 3004 fire control panel for max. 126 loop3000 components art. 30209 2-loop interface 20 up to 28 V DC 40 mA max. 100 mA RS 232 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm remarks: use the current version of the loop calculator to determin the maximum number of loop devices/components and mix DLI 3240 X1-2L • • • • • • • • • maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm) all loop3000 components can be addressed automatically manual addressable with EasyCheck 3000 (31482) two - wire - loop 8 freely programmable open collector outputs 3 open collector outputs 30 V DC / 90 mA for alarm and fault loop voltage 32 V DC, loop current 100 mA per loop RS 232 interface for additional data monitoring slot for optional redundant processor technical specification operation voltage quiesent current alarm current interfaces open collector output operation temperature weight dimensions (H x W x D) to plug in to the detect 3004 fire control panel for max. 2x126 loop3000 components 20 up to 28 V DC 40 mA max. 2 x 100 mA RS 232 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm remarks: use the current version of the loop calculator to determin the maximum number of loop devices/components and mix 7 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 32098 2-loop interface active DLI 3240 P X1 • • • • • • • • • maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm) all loop3000 components can be addressed automatically manual addressable with EasyCheck 3000 (31482) two - wire - loop 8 freely programmable open collector outputs 3 open collector outputs 30 V DC / 90 mA for alarm and fault loop voltage 32 V DC, loop current 140 mA per loop RS 232 interface for additional data monitoring slot for optional redundant processor technical specification operation voltage quiesent current alarm current interfaces open collector output operation temperature weight dimensions (H x W x D) picture similar to plug in to the detect 3004 fire control panel for max. 2x126 loop3000 components art. 31312 2-loop interface redundant 20 up to 28 V DC 40 mA max. 2 x 140 mA RS 232 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm remarks: use the current version of the loop calculator to determin the maximum number of loop devices/components and mix CP DLI 3240 X1-R • • • • • • • • • maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm) all loop3000 components can be addressed automatically manual addressable with EasyCheck 3000 (31482) two - wire - loop 8 freely programmable open collector outputs 3 open collector outputs 30 V DC / 90 mA for alarm and fault loop voltage 32 V DC, loop current 100 mA per loop RS 232 interface for additional data monitoring redundant second processor for emergency operation technical specification operation voltage quiesent current alarm current interfaces open collector output operation temperature weight dimensions (H x W x D) to plug in to the detect 3004 fire control panel for max. 2x126 loop3000 components 20 up to 28 V DC 40 mA max. 2 x 100 mA RS 232 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm remarks: use the current version of the loop calculator to determin the maximum number of loop devices/components and mix 8 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 30210 conventional interface for 8 fire zones CP CLI X1 to plug in to the detect 3004 fire control panel for max. 8 conventional fire zones • • • • maximum 25 conventional detectors per fire zone connectable 8 freely programmable open collector outputs 30 V DC / 90 mA 3 open collector outputs 30 V DC / 90 mA slot for optional redundant processor technical specification operation voltage alarm current open collector output operation temperature weight dimensions (H x W x D) art. 30927 ground circuit module 20 up to 28 V DC 85 mA + 50 mA per zone output 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm CP EM to plug in to the detect 3004 fire control panel for monitoring of the galvanic separation between ground potential and all secundary voltages e.g. fire zone, monitoring outputs technical specification operation voltage quiesent current open collector output operation temperature front color material weight dimensions (H x W x D) art. 30088 LED indicator modul 18 up to 30 V DC 7 mA fault output voltage: max 29 V fault output current: max. 0,1 A -5°C up to +50°C green polyamid PA6.6 50 g 59 mm x 20 mm x 60 mm CP ZM 8 two LED indicators for 8 zones per modul to plug into the fire control panel detect 3004 for zone alarm and zone fault indication • • 1 red and 1 yellow LED per fire zone 8 fire zones on 1 modul technical specification alarm current operation temperature dimensions (H x W) 3 mA per zone -5°C up to +40°C 93 mm x 80 mm remarks: a maximum of 6 LED indicator modules are available, an adapter plate 30386 is required for more than 16 zones 9 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 30386 adapter for LED indicator modul CP ADB 48 to plug into the detect 3004 fire conrol panel more than two LED indicator modules 30088 technical specification operation temperature dimensions (H x W) -5°C up to +40°C 55 mm x 108 mm remarks: a maximum of 6 alarm indicator zones available, adapter plate 30386 irequired after 16 zones art. 31946 mounting plate expansion mounting plate to plug in to the detect 3004 fire control panel front for up to 6 LED indicator modules or / and protocol printer including front foil • • • mounting plate for maximum 6 LED indicator modules provides facility for protocol printer 30099 or 30106 zones can be identified by labelling art. 30111 CP MP 3004 technical specification operation temperature dimensions (H x W) -5°C up to +40°C 228 mm x 365 mm remarks: installation into the detect 3004 fire control panel possible extinguishing control modul CP ETB X1 plug in extinguishing control module for the detect 3004 fire panel to control one extinguishing area • • • direct activation of the extinguishing area valves 4 monitored control lines for signal transmitter and solenoid valves activation from loop or conventional interface technical specification operation voltage quiesent current alarm current sounder output external user output operation temperature dimensions (H x W x D) 20 up to 28 V DC 45 mA 60 mA + 1 A per output 4 x 24 V DC / 1 A monitored 4 x 24 V DC / 1 A monitored -5°C up to +40°C 140 mm x 140 mm x 20 mm remarks: an additional extinguishing panel is not necessary 10 www.detectomat.com 1. fire control panels 1.1 detect 3004 fire control panel and accessories art. 31318 universal expansion housing UZG-1 provides additional space for ancilary components • • sheet steal housing compatible with fire control panel detect 3004 lock for door technical specification protection class housing color front color material weight dimensions (H x W x D) art. 30113 redundant main board processor to plug in to the detect 3004 fire panel to duplicate the main board processor CP CPU X1-R technical specification approvals • IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 5 kg 490 mm x 420 mm x 210 mm VdS G 203 068 takes over the control in case of CPU-failure 11 www.detectomat.com 1. fire control panels 1.2 detect 3016 fire control panel and accessories art. 31989 fire control panel detect 3016 • • • • • • • • • • • • • • • • • • • additional two extension with 2+1 slots connectable (max. to equip up to 16 loops or 64 conventional fire zones) 2 slots for fire brigade and network interface 192 programmable detector zones up to 16 x 126 loop3000 components up to 64 conventional fire zones maximum loop length 3.000 m (using installation cable IY(St)Y 2 x 0,8 mm) monitored loop operation with detection system loop3000 integrated fire brigade interface for control of display panel, transmission- and key-depot adapter interface 3 potential-free relay outputs (250 V / 5 A) 9 open collector outputs (30 V / 90 mA) monitored signal transmitter 400 mA 2 additional external outputs 24V / 800mA 2 RS 232 interfaces for personal computer, printer, modem, building management system network compatible via bitbus interface up to 32 fire control panels or additional 63 bitbus components operation and event memory for 500 messages (first in first out principle) possibility via mounting panel to integrate a protocol-printer and LED indicator modules for zone alarm and zone fault indication option to equip a redundant main board processor (second CPU) power supply 192 W and monitored battery condition storing space for two batteries 12 V / 45 Ah technical specification input voltage frequency operation voltage power supply emergency power interfaces display zone LED´s sounder output external user output relay output open collector output operation temperature humidity protection class housing color front color material weight dimensions (H x W x D) approvals Microprocessor controlled modular fire control panel DIN EN 54, V DE 0833 and VdS approved. For use with the loop3000 fire detection system components. • • • display- and control panel DIN EN 54 part 2 4 alphanumeric lines LCD- display with backlight the basic version offers 5 slots for detector interface boards and 1 slot for OC - boards complies with 230 V AC (-15 % / +10%) 50 / 60 Hz 21,0 up to 29,2 V DC 192 W max. 2 x 12 V / 45 Ah 2x RS 232/422 Bitbus (option) LCD 4 x 20 characters poss. for up to 192 zone indicators 24 V DC / 400 mA monitored 2 x 24 V DC / 800 mA 3 change over 250 V / 5 A 9 open collector 30 V DC / 90 mA -5°C up to +40°C max. 95 % IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 30,0 kg 750 mm x 600 mm x 240 mm VdS: G 203067, S 295054, LPCB, GOST, CCC, Hungary, Bulgaria, Lithuania, Czech Republik, Ukrain, Slovakia, Slovenia, Spain, Switzerland, Belgium EN 54 - 2 remarks: if you use a printer 30106 you can use only up to 5 LED indicator modules for 160 fire zones 12 www.detectomat.com 1. fire control panels 1.2 detect 3016 fire control panel and accessories art. 31990 fire control panel 19" rack mount detect 3016-19" • • • • • • operation and event memory for 500 messages (first in first out principle) suitable for 19" rack mount possibility via mounting panel to integrate a protocol-printer and LED indicator modules for zone alarm and zone fault indication option to equip a redundant main board processor (second CPU) power supply 192 W and monitored battery condition usable for two batteries 12 V / up to 65 Ah technical specification Microprocessor controlled modular fire control panel, 19" rack mount version, DIN EN 54, VDE 0833 and VdS approved. For use with the loop3000 fire detection system components. • • • • • • • • • • • • • • • • • display- and control panel DIN EN 54 part 2 4 alphanumeric lines LCD- display with backlight the basic version offers 5 slots for detector interface boards and 1 slot for OC - boards additional two extension with 2+1 slots connectable (max. to equip up to 16 loops or 64 conventional fire zones) 2 slots for fire brigade and network interface 192 programmable detector zones up to 16 x 126 loop3000 components up to 64 conventional fire zones maximum loop length 3.000 m (using installation cable IY(St)Y 2 x 0,8 mm) monitored loop operation with detection system loop3000 integrated fire brigade interface for control of display panel, transmission- and key-depot adapter interface 3 potential-free relay outputs (250 V / 5 A) 9 open collector outputs (30 V / 90 mA) monitored signal transmitter 400 mA 2 additional external outputs 24V / 800mA 2 RS 232 interfaces for personal computer, printer, modem, building management system network compatible via bitbus interface up to 32 fire control panels or additional 63 bitbus components art. 31991 language kit German language kit integrates German software, German description, German labelling art. 31992 language kit English language kit integrates English software, English description, English labelling, additional languages available on request input voltage frequency operation voltage power supply emergency power interfaces display zone LED´s sounder output external user output relay output open collector output operation temperature humidity protection class front color material weight dimensions (H x W x D) approvals complies with 230 V AC (-15 % / +10%) 50 / 60 Hz 21,0 up to 29,2 V DC 192 W max. 2 x 12 V / 45 Ah 2x RS 232/422 Bitbus (option) LCD 4 x 20 characters poss. for up to 192 zone indicators 24 V DC / 400 mA monitored 2 x 24 V DC / 800 mA 3 change over 250 V / 5 A 9 open collector 30 V DC / 90 mA -5°C up to +40°C max. 95 % IP 30 tele grey, RAL 7046 sheet steel 20 kg 6 HE x 19" VdS: G 203067, S 295054, LPCB, GOST, CCC, Hungary, Bulgaria, Lithuania, Czech Republik, Ukrain, Slovakia, Slovenia, Spain, Switzerland, Belgium EN 54 - 2 remarks: • the panel is designed to be mounted in a 19"- rack • the power pack is separately mounted in the 19"- rack • additional space is required for battery storage LK 3016 D remarks: it is essential to specify the language kit when ordering LK 3016 GB remarks: it is essential to specify the language kit when ordering 13 www.detectomat.com 1. fire control panels 1.2 detect 3016 fire control panel and accessories art. 30201 2-loop interface redundant DLI 3240 X2-R to plug in to the detect 3016 fire control panel for max. 2 x 126 loop3000 components • • • • • • • • • maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm) all loop3000 components can be addressed automatically manual addressable with EasyCheck 3000 (31482) two - wire - loop 8 freely programmable open collector outputs 3 open collector outputs 30 V DC / 90 mA for alarm and fault oop voltage 32 V DC, loop current 100 mA per loop RS 232 interface for additional data monitoring redundant board processor unit to duplicate the functions technical specification operation voltage quiesent current alarm current interfaces open collector output operation temperature weight dimensions (H x W x D) 20 up to 28 V DC 40 mA max. 2 x 100 mA RS 232 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm remarks: use the current version of the loop calculator to determin the maximum number of loop devices/components and mix art. 32099 2-loop interface active, redundant DLI 3240 P X2-R to plug in to the detect 3016 fire control panel for max. 2 x 126 loop3000 components • • • • • • • • • maximum loop length 3.000 m (installation cable IY(St)Y 2 x 0,8 mm) all loop3000 components can be addressed automatically manual addressable with EasyCheck 3000 (31482) two - wire - loop 8 freely programmable open collector outputs 3 open collector outputs 30 V DC / 90 mA for alarm and fault loop voltage 32 V DC, loop current 140 mA per loop RS 232 interface for additional data monitoring redundant board processor unit to duplicate the functions technical specification picture similar operation voltage quiesent current alarm current interfaces open collector output operation temperature weight dimensions (H x W x D) approvals 20 up to 28 V DC 40 mA max. 2 x 140 mA RS 232 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm VdS: G 203067 remarks: use the current version of the loop calculator to determin the maximum number of loop devices/components and mix 14 www.detectomat.com 1. fire control panels 1.2 detect 3016 fire control panel and accessories art. 30096 conventional interface redundant 8 fire zones CP CLI X2-R to plug in to the detect 3016 fire control panel for max. 8 conventional fire zones • • • • maximum 25 conventional detectors per fire zone connectable 8 freely programmable open collector outputs 30 V DC / 90 mA 3 open collector outputs 30 V DC / 90 mA redundant board processor unit to duplicate the functions technical specification operation voltage quiesent current alarm current open collector output operation temperature weight dimensions (H x W x D) art. 30097 extension module 20 up to 28 V DC 60 mA 85 mA + 50 mA per zone output 11 open collector 30 V DC / 90 mA -5°C up to +40°C 200 g 140 mm x 140 mm x 30 mm CP ECB to expand the detect 3016 fire control panel mother board • 3 slots for plug in 2 additional loop-/conventional interfaces and 1 alarm module technical specification operation temperature -5°C up to +40°C remarks: maximum up to 2 units per detect 3016 fire control panel usable art. 30098 LED indicator modul CP ZM 32 two LED indicators for 32 zones per modul to plug into the fire control panel detect 3016 for zone alarm and zone fault indication • • 1 red and 1 yellow LED per fire zone 32 fire zones on 1 modul technical specification alarm current operation temperature dimensions (H x W) 3 mA per zone -5°C up to +40°C 108 mm x 193 mm remarks: maximum of 6 LED indicator modules 15 www.detectomat.com 1. fire control panels 1.2 detect 3016 fire control panel and accessories art. 31947 mounting plate expansion mounting plate to plug in to the detect 3016 fire control panel front for up to 6 LED indicator modules or / and protocol printer including front foil • • • mounting plate for maximum 6 LED indicator modules provides possibility for protocol printer 30099 or 30106 zones can be identified by labelling CP MP 3016 technical specification operation temperature dimensions (H x W) -5°C up to +40°C 400 mm x 483 mm remarks: laterly installation into the detect 3016 fire control panel possible art. 30164 mounting panel expansion mounting front to add 19" components for the 19" cabinate MP-1 technical specification material dimensions (H x W) sheet steel 878 mm x 485 mm remarks: one mounting plate MP-1 is included in the deivery of the 19" cabinet 30162 und 30163 art. 30167 19" front panel 64 19" FP-1 to integrate 2 zone alarm device indications type 30098 • front foil with label for fire zones 1-64 technical specification front color material dimensions (H x W) art. 30168 19" front panel 128 19" FP-2 to integrate 2 zone alarm device indications type 30098 technical specification • front color material dimensions (H x W) front foil with label for fire zone 65 - 128 art. 30169 19" front panel 192 tele grey, RAL 7046 sheet steel 3HE x 19" 19" FP-3 to integrate 2 zone alarm device indications type 30098 technical specification • front color material dimensions (H x W) front foil with label for fire zone 129 - 192 tele grey, RAL 7046 sheet steel 3HE x 19" 16 www.detectomat.com tele grey, RAL 7046 sheet steel 3HE x 19" 1. fire control panels 1.2 detect 3016 fire control panel and accessories art. 40003 extinguishing control modul CP ETB X2 plug in extinguishing control module for the detect 3016 fire panel to control one extinguishing area • • • direct activation of the extinguishing area valves 4 monitored control lines for signal transmitter and solenoid valves activation from loop or conventional interface technical specification operation voltage quiesent current alarm current sounder output external user output operation temperature dimensions (H x W x D) approvals 20 up to 28 V DC 45 mA 60 mA + 1 A per output 4 x 24 V DC / 1 A monitored 4 x 24 V DC / 1 A monitored -5°C up to +40°C 140 mm x 140 mm x 20 mm VdS G 203 067 remarks: an additional extinguishing panel is not necessary art. 31320 universal expansion housing UZG-2 provides additional space for ancilary components • • sheet steal housing compatible with fire control panel detect 3016 lock for door technical specification protection class housing colour front color material weight dimensions (H x W x D) art. 30112 redundant main board processor to plug in to the detect 3016 fire panel to duplicate the main board processor • takes over the control in case of CPU-failure IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 10 kg 750 mm x 600 mm x 240 mm CP CPU X2-R technical specification quiesent current alarm current operation temperature 50 mA 50 mA -5°C up to +40°C 17 www.detectomat.com 1. fire control panels 1.3 detect 3004/3016 panel accessories art. 30077 relay board 8 change over to expand 8 relay outputs for all fire control panels of the system detect 3000 • • • • 8 potential-free output relays, change over contact 8 inputs controlled by the fire control panel 8 LED´s to display the current operation status mountabel on C-rails 35mm in the panel art. 32066 monitored module for 4 outputs RL 58 technical specification operation voltage quiesent current alarm current relay output operation temperature protection class housing color material dimensions (H x W x D) approvals SC 4 to expand 4 monitored outputs for all kind of signalling devices on the fire control panels of the system detect 3000 • • operation voltage quiesent current alarm current sounder output • • • • • • external powered via fire control panel 4 jumpers "acoustics on/off option" to control the noise of the outputs 4 output channels with 24 V for all kind of signalling devices output current 400 - 600 mA choosable by jumper monitorings for short circuit, broken wire, general fault and alarm 4 alarm inputs to activate the selected output 1 general alarm input to activate all outputs art. 30118 monitored module for 8 outputs 21 up to 28 V DC 3,5 mA 25 mA per relay 8 x change over 250 V / 5 A -5°C up to +40°C IP 20 green ABS 125 mm x 110 mm x 60 mm VdS G 203 067 "Acoustics on / off" input to disable, set or reset all of the outputs selected by the jumpers technical specification operation temperature protection class housing color material dimensions (H x W x D) SC 8 • • • 21 up to 28 V DC 1,6 up to 2,5 mA 2,5 mA + 400/600 mA per output 4 x 24 V DC / 400 or 600 mA monitored -5°C up to +40°C IP 20 green ABS 125 mm x 130 mm x 50 mm VdS G 203067 8 manual switched inputs 1 general alarm input to activate all outputs external powered 24 V DC / maximum 3,2 A technical specification to expand 8 monitored outputs for all kind of signalling devices on the fire control panels of the system detect 3000 • • • 8 monitored 24 V DC / 400 mA for signalling devices (separate fused) 8 open collector outputs for LED indicators 8 alarm inputs to activate the selected output operation voltage quiesent current alarm current sounder output open collector output operation temperature protection class housing color material dimensions (H x W x D) approvals 21 up to 28 V DC 58 mA 58 mA + 400 mA per output 8 x 24 V DC / 400 mA monitored 12 outputs 24 V DC / 90 mA -5°C up to +40°C IP 20 green ABS 125 mm x 175 mm x 60 mm VdS G 203 067 remarks: it is essential to use the interface 31446 in the fire control panel 18 www.detectomat.com 1. fire control panels 1.3 detect 3004/3016 panel accessories art. 30115 OC control module CP AM 32 to expand 32 open collector outputs for all kind of control functions on the fire control panels of the system detect 3000 • • • • 32 open collector outputs 24 V DC / 90 mA all outputs are free programmable for alarm events in the fire control panel up to 6 boards usable in detect 3016 up to 24 outputs usable in detect 3004 technical specification operation voltage quiesent current alarm current interfaces open collector output operation temperature dimensions (H x W x D) approvals art. 30116 connection board 21 up to 28 V DC 3,5 mA 25 mA per relay RS 232 32 outputs 24 V DC / 90 mA -5°C up to +40°C 140 mm x 140 mm x 25 mm VdS G 203 067 CP AM AP • • connectable via housing on DIN rails 35 mm usable as connecting box for the OC control module in installations outside the fire control panel technical specification connection board for a separate installation of the CP AM 32 art. 30114 extinguishing interface protection class housing colour material dimensions (H x W x D) IP 20 orange ABS 88 mm x 175 mm x 70 mm CP SIE • indication and control functions according VdS technical specification operation voltage quiesent current relay output operation temperature protection class housing color material dimensions (H x W x D) approvals interface to expand the fire control panel detect 3000 for connection on an extinguishing control panel • connection of extinguishing control panels for several areas possible 21 up to 28 V DC 30 mA 8 x change over 250 V / 5 A -5°C up to +40°C IP 20 green ABS 125 mm x 110 mm x 60 mm VdS G 203 067 remarks: • it is essential to use a conventional interface to connect the detector zones in the fire control panel • maximum 4 extinguishing areas programmable 19 www.detectomat.com 1. fire control panels 1.3 detect 3004/3016 panel accessories art. 31596 parallel indicator display ZPA2002 • • • • • • • • simultaneous display of 2 messages optional selection of RS 232 or RS 422 communication length max. 800 m including buzzer collectiv LED indicators for operation, alarm, fault and cut-off powered via fire control panel automatically data-transfer from the fire control panel more than 4.000 texts programmable technical specification parallel indicator display unit to display the current status of the fire control panels detect 3000 • • including an additional interface RS232/422 and ESPA 4.4.4 for nurse call systems display with 4 x 20 characters art. 30106 mount in printer to expand the front of the fire control panel detect 3000 with a printer • • • • • thermo printer with 24 characters 58 mm paper width integrated printer memory of 8 k RAM direct connectable on the fire control panels interface RS 232 powered via fire control panel remarks: by using the printer in the fire control panel detect 3004 are maximum 18 Ah batteries usable, it is essential to specify an CP MP for the panel when ordering art. 30099 mount in printer including paper storage to expand the front of the 19" fire control panel detect 3000 with a printer • • • • • thermo printer with 24 characters 58 mm paper width integrated printer memory of 8 k RAM direct connectable on the fire control panels interface RS 232 powered via fire control panel remarks: only usable for 19" housings, it is essential to specify a CP MP for the panel when ordering operation voltage quiesent current alarm current interfaces operation temperature protection class housing color front colour material dimensions (H x W x D) approvals 10 up to 30 V DC 35 mA 100 mA RS232/422 ESPA 4.4.4 -5°C up to +40°C IP 30 light grey, RAL 7035 black ABS 273 mm x 223 mm x 54 mm VdS G 203086 PIP 2 technical specification operation voltage quiesent current alarm current interfaces operation temperature protection class front colour material dimensions (H x W x D) approvals 21 up to 28 V DC 12 mA 100 mA RS 232 -5°C up to +40°C IP 30 black ABS 115 mm x 115 mm x 80 mm VdS G 203 067 PIP 1 technical specification operation voltage quiesent current alarm current interfaces operation temperature protection class front colour material dimensions (H x W x D) approvals 20 www.detectomat.com 21 up to 28 V DC 40 mA 460 mA RS 232 -5°C up to +40°C IP 30 silver aluminium 130 mm x 107 mm x 165 mm VdS G 203 067 1. fire control panels 1.3 detect 3004/3016 panel accessories art. 30471 power supply 120 W NT 5 usable as additional power supply for the detect 3000 system technical specification • • • input voltage frequency operation voltage power supply external user output operation temperature protection class housing color front colour material weight dimensions (H x W x D) power supply 230 V AC, 24 V DC, 5 A temperature compensated battery-loading integrated LED indicators for operation and fault art. 30131 power supply 192 W NT 8 usable as additional power supply for the detect 3000 system technical specification • • • input voltage frequency operation voltage power supply external user output operation temperature protection class housing color front colour material weight dimensions (H x W x D) power supply 230 V AC, 24 V DC, 8 A temperature compensated battery-loading integrated LED indicators for operation and fault art. 40056 battery 12 V / 7,2 Ah 230 V AC 50 / 60 Hz 24 V DC 120 W 3 x 1,6 A separately fused -5°C bis +40°C IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 13,0 kg 442 mm x 525 mm x 200 mm 230 V AC 50 / 60 Hz 24 V DC 155 W 4 x 1,6 A separately fused -5°C bis +40°C IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 16,0 kg 442 mm x 525 mm x 200 mm B 12/ 7,2Ah • plug-in connections: 4,8 mm technical specification weight dimensions (H x W x D) approvals art. 30155 • battery 12 V / 12 Ah plug-in connections: 6,3 mm 2600 g 99 mm x 150 mm x 65 mm VdS G 103061 B 12/ 12Ah technical specification weight dimensions (H x W x D) approvals 4200 g 98 mm x 151 mm x 98 mm VdS G 103063 21 www.detectomat.com 1. fire control panels 1.3 detect 3004/3016 panel accessories art. 30156 • battery 12 V / 18 Ah screw connections for M 5 B 12/ 18Ah technical specification weight dimensions (H x W x D) approvals art. 40001 • battery 12 V / 26 Ah B 12/ 26Ah technical specification screw connections for M 5 weight dimensions (H x W x D) approvals art. 30151 • battery 12 V / 45 Ah technical specification weight dimensions (H x W x D) approvals • battery 12 V / 65 Ah screw connections for M 6 base for overvoltage protection modules 14,5 kg 170 mm x 197 mm x 165 mm VdS G 102002 B 12/ 65Ah technical specification weight dimensions (H x W x D) approvals art. 30321 8,5 kg 125 mm x 176 mm x 166 mm VdS G 103065 B 12/ 45Ah screw connections for M 6 art. 30461 6,5 kg 167 mm x 81 mm x 76 mm VdS G 103064 30,0 kg 174 mm x 350 mm x 174 mm VdS G 102001 CT B for connection of one protection module • • overvoltage protection max. permanent voltage 250 V AC or 350 V DC for two wires technical specification operation voltage operation temperature protection class housing color material dimensions (H x W x D) 22 www.detectomat.com 250 V AC / 350 V AC -40°C up to +80°C IP 20 yellow PA 6.6 90 mm x 12 mm x 44 mm 1. fire control panels 1.3 detect 3004/3016 panel accessories art. 30335 loop protection module CT ME 48 overvoltage protection for all loop3000 panel boards and open collector outputs • • art. 30336 conventional protection module overvoltage protection for loop3000 nominal discharge current (8/20 µs): 10 kA CT ME / C 24 overvoltage protection for conventional zones • • art. 30337 bitbus protection module overvoltage protection for conventional zones nominal discharge current (8/20 µs): 10 kA CT ME 5 overvoltage protection for BitBus data cables • • art. 30138 modem overvoltage protection for conventional zones nominal discharge current (8/20 µs): 10 kA RM MO • • • interface to connect the control panels detect 3000 via phone line connectable via RS232 on the panel powered via the rife control panel technical specification interface modem to control the fire control panels detect 3000 via phone line input voltage frequency operation voltage interfaces housing color front colour material dimensions (H x W x D) 230 V AC 50 / 60 Hz 9 up to 30 V AC or 9 up to 42 V DC RS 232 grey grey aluminium 35 mm x 110 mm x 130 mm 23 www.detectomat.com 1. fire control panels 1.4 network components art. 32118 remote display- and control panel ABF • • • • operation and event memory for 500 messages (first in first out principle) option to equip a redundant main board processor (second CPU) external powered via fire control panel or power supply wall mount housing technical specification to expand the detect 3000 fire detection network for an separate remote display- and control panel, wall mount housing • • • • • • • • • • • display- and control panel DIN EN 54 part 2 including Bitbus interface for interlink connection 4 alphanumeric lines LCD- display with backlight 2 slots for fire brigade and network interface 128 programmable detector zones possibility for integration of fire brigade interface, display panel, transmission- and key-depot adapter interface 3 potential-free relay outputs (250 V / 5 A) 9 open collector outputs (30 V / 90 mA) monitored signal transmitter 400 mA 2 RS 232 interfaces for personal computer, printer, modem, building management system network compatible via bitbus interface up to 32 fire control panels or additional 63 bitbus components art. 32039 language kit German language kit integrates German software, German description, German labelling art. 32040 language kit English language kit integrates English software, English description, English labelling operation voltage power supply emergency power quiesent current alarm current interfaces display sounder output external user output relay output open collector output operation temperature humidity protection class housing color front color material weight dimensions (H x W x D) complies with 21,0 up to 29,2 V DC 72 W max 2 x 12 V / 12 Ah 132 mA 192 mA 2 x RS 232/422 Bitbus (option) LCD 4 x 20 characters 24 V DC / 400 mA monitored 24V DC / 800 mA 3 change over 250 V / 5 A 9 open collector 30 V DC / 90 mA -5°C bis +40°C up to 95 % IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 6 kg 262 mm x 420 mm x 83 mm EN 54 - 2 remarks: • it is essential to have a separate master display- and control panel ABF in the BitBus network • to create an display and control panel including power supply you have to use an detect 3004 shallow with and language kit ABF • it is essential to specify an language kit when ordering for a master panel in the BitBus network LK ABF D remarks: it is essential to specify the language kit when ordering for a master panel in the BitBus network • LK ABF GB additional languages available on request remarks: it is essential to specify the language kit when ordering 24 www.detectomat.com 1. fire control panels 1.4 network components art. 32119 remote display- and control panel ABF-19” • • external powered via fire control panel or power supply 19" or mount in front technical specification to expand the detect 3000 fire detection network for an separate remote display- and control panel, 19" or mount in version • • • • • • • • • • • • • display- and control panel DIN EN 54 part 2 including Bitbus interface for interlink connection 4 alphanumeric lines LCD- display with backlight 2 slots for fire brigade and network interface 128 programmable detector zones possibility for integration of fire brigade interface, display panel, transmission- and key-depot adapter interface 3 potential-free relay outputs (250 V / 5 A) 9 open collector outputs (30 V / 90 mA) monitored signal transmitter 400 mA 2 RS 232 interfaces for personal computer, printer, modem, building management system network compatible via bitbus interface up to 32 fire panel controls or additional 63 bitbus components operation and event memory for 500 messages (first in first out principle) option to equip a redundant main board processor (second CPU) art. 31315 LCD repeater panel operation voltage power supply emergency power quiesent current alarm current interfaces display sounder output external user output relay output open collector output operation temperature humidity protection class housing color front color material weight dimensions (H x W x D) complies with 21,0 up to 29,2 V DC 72 W max 2 x 12 V / 12 Ah 132 mA 192 mA 2x RS 232/422 Bitbus (option) LCD 4 x 20 characters 24 V DC / 400 mA monitored 24 V DC / 800 mA 3 change over 250 V / 5 A 9 open collector 30 V DC / 90 mA -5°C bis +40°C up to 95 % IP 30 light grey, RAL 7035 tele grey, RAL 7046 sheet steel 6 kg 6 HE x 19” x 83 mm EN 54 - 2 remarks: • it is essential to have a separate master display- and control panel ABF in the BitBus network • to create an display and control panel including power supply you have to use an detect 3004 shallow with and language kit ABF • it is essential to specify an language kit when ordering LCD-Tableau • • • • • • • • maximum 61 repeater panels in one BitBus network usable 4 lines with backlight LC-display display character size 10 mm integrated buzzer, with quiesent button scroll-function of the display by buttons flat design housing made of brushed stainless steel automatic data-transfer from the fire control panel external voltage supply 24 V DC technical specification remote display unit for communication with the fire detection system detect 3000 • • displaying of the current status of all loop devices and zones in the BitBus network monitored interface to the BitBus network operation voltage interfaces display operation temperature humidity protection class housing color front color material dimensions (H x W x D) 21 up to 28 V DC Bitbus LCD 4 x 20 characters -5°C bis +40°C up to 95 % IP 30 silver grey stainless steel 240 mm x 295 mm x 43 mm 25 www.detectomat.com 1. fire control panels 1.4 network components art. 30087 bitbus interface CP BBI • • • • to build up a fire control panel network of up to 32 fire control panels and up to 64 BitBus components via 4-wired interface distances up to 1.200 m (3,900 feet) possible via bitbus repeater a max. of 13.200 m can be realized in one network data rate max 375 kBd technical specification operation voltage interfaces operation temperature dimensions (H x W x D) 21 up to 28 V DC Bitbus -5°C bis +40°C 25 mm x 50 mm x 59 mm to expand the fire control panel detect 3000 to interlink several fire control panels, control- and display panels and other bitbus components art. 30119 bitbus CPU BB-CPU • • • maximum 61 units in one BitBus network usable outputs free programmable external powered 24 V DC technical specification seperate intellegent unit to control outputs in the BitBus network without using fire control panels operation voltage quiesent current alarm current interfaces operation temperature protection class housing color material dimensions (H x W x D) • • remarks: it ist essential to programm the unit via bitbus modem 30139 together with the DPT3000 software up to 8 extensions 30120 / 30122 connectable housing for plug in on DIN rails art. 30120 extension for BitBus CPU, 32 open collector outputs 21 up to 28 V DC 150 mA 150 mA Bitbus -5°C bis +40°C IP 20 green ABS 125mm x 133 mm x 58 mm BB-32 • • housing for plug in on DIN rails up to 8 units on one BitBus CPU usable technical specification to expand the BitBus CPU for 32 open collector outputs • 32 open collector outputs 24 V DC / 90 mA operation voltage quiesent current alarm current open collector output operation temperature protection class housing color material dimensions (H x W x D) 26 www.detectomat.com 21 up to 28 V DC 5 mA max. 320 mA 32 open collector 30 V DC / 90 mA -5°C bis +40°C IP 20 green ABS 125 mm x 163 mm x 60 mm 1. fire control panels 1.4 network components art. 30122 extension for BitBus CPU, 16 relay outputs BB-16 • • • 16 relay outputs 30 V DC / 2 A housing for plug in on DIN rails upto 8 units on one BitBus CPU usable technical specification operation voltage quiesent current alarm current relay output operation temperature protection class housing color material dimensions (H x W x D) 21 up to 28 V DC 5 mA max. 320 mA 3 change over 30 V / 2 A -5°C bis +40°C IP 20 green ABS 125 mm x 163 mm x 60 mm to expand the BitBus CPU for 16 relay outputs art. 30128 BitBus LED indicator extension BB-LED • • outputs free programmable external powered 24 V DC technical specification seperate intellegent unit to control LED indicators in the BitBus network without using fire control panels • • • for max. 192 LED indicators per interface 6 connection interfaces for LED indicator modul CP ZM 32 maximum 61 units in one BitBus network usable art. 30124 BitBus amplifier operation voltage quiesent current alarm current interfaces external user output operation temperature protection class housing color material dimensions (H x W x D) 21 up to 28 V DC 155 mA max. 320 mA Bitbus 6 x cable connection for CP ZM 32 -5°C bis +40°C IP 20 green ABS 125 mm x 275 mm x 75 mm BB-R • including power supply technical specification booster for refreshing the BitBus-signals for cable length > 1200 m • • • each repeater increase the length of the BitBus network up to 1.200 m 10 repeater units in one network usable (13.200 m) the repeater needs no address in the BitBus network input voltage frequency operation voltage interfaces emergency power interfaces protection class operation temperature protection class housing color material dimensions (H x W x D) 230 V AC 50 / 60 Hz 5 V DC 2 x Bitbus optional 2 x Bitbus IP 52 -5°C bis +40°C IP 20 grey ABS 122 mm x 66 mm x 54 mm 27 www.detectomat.com 1. fire control panels 1.4 network components art. 31024 BitBus computer interface ISA-Slot BBI PC • • • interface for connection of the visual detect software to the BitBus network ISA slot plug-in card with integrated BitBus interface maximum two usable in one BitBus network technical specification operation voltage interfaces operation temperature to connect the computer to the fire control panel detect 3000 network art. 31621 BitBus - fibre optical interface 5 V DC ISA-Bitbus -5°C up to +40°C remarks: up to 99 computers can be connected in the detect 3000 system via user extensions in the visual detect software via TCP/IP protocol LCON-1 • • • • • transmission rate max. 5 Mbit each second maximum transmission distance per unit 2.600 m wave length 820 mm transmission half duplex externally powered technical specification active interface modul to realize an fibre optical BitBus network for the fire control panels detect 3000 • • converter with one fibre optical and one bitbus channel fibre optical connector F-ST art. 31622 fibre optical cable converter operation voltage quiesent current interfaces operation temperature protection class housing color material weight dimensions (H x W x D) 18 up to 30 V DC 250 mA Bitbus F-ST 0°C up to +70°C IP 30 black polyamid 250 g 82 mm x 93 mm x 22,5 mm LCON-2 • • • • • transmission rate max. 5 Mbit each second optical budget 8 (4,2) dB transmission path 2.600 (1.400) m wave length 820 mm transmission half duplex technical specification to active couple the bitbus to the fibre optical cable redundant transmission path • • LCON is a bitbus fibre optical cable converter with two fibre optical cable channels and one bitbus channel fibre optical cable connector F-ST operation voltage quiesent current interfaces operation temperature protection class housing color material weight dimensions (H x W x D) 28 www.detectomat.com 18 up to 30 V DC 250 mA Bitbus F-ST 0°C up to +70°C IP 30 black polyamid 250 g 82 mm x 93 mm x 40 mm 1. fire control panels 1.5 programming tools and software art. 30501 I-Check 3000 software I-Check 3000 loop configuration and test software • • • • • • • • • • • • art. 30136 detectomat programming tool configuration software for the fire control panels, the separate remote display- and repeater panel and the BitBus CPU of the system detect 3000 loop diagnostics and the location of failures are automatically displayed in a graphic of the loop3000 devices graphical representation of the loop structure via software the loop devices are constantly analysed and the analogue values are displayed graphical display of the analogue values of smoke, contamination, temperature, loop-voltage and temperature-compensation display of detector-type, serial-number, detector-zone with number, free customer text all data can be exported in Excel or Word files extensive print functions of graphics and charts configuration for all loop devices (algorithms, sensitivities, etc.) Windows based user interface the software runs on required Windows 98, 2000 or XP supports by loop Tester LT 3000 data medium CD-ROM DPT 3000 • • • • • • art. 30137 software-expansion-dongle software protection dongle for remote acces for all fire contraol panels of the system detect 3000 D 3000 • • • art. 30139 Bitbus programming tool programming tool for the BitBus CPU programming of the fire control panel network-configuration supported by remote maintenance (software-expansion-dongle 30137) Windows user interface the software runs on required Windows 98, 2000 or XP Data medium CD-ROM protection for the software activation of the features: remote diagnostics, status display and remote control of the fire control panel detect 3004, 3016 and the separate display repeater via the fire control modem dongle for 25 pole printer interface BPT • including power supply connection and interface cables 29 www.detectomat.com 1. fire control panels 1.5 programming tools and software art. 31482 EasyCheck EC 3000 manual programming tool for all loop3000 devices • • • • • • • • • art. 31625 loop tester manual addressing and programming tool for all loop3000 devices battery-operated stand-alone unit double-spaced lighted LC-display keypad Integrated detector base separate connection for loop modules and manual call points read-out and changing of the addresses and grades of sensitivity of all loop3000 elements copy-function for device replacement transportation suitcase, 3 batteries type AA, interface-cable, carrier-belt, cable to connect modules and manual call points are included in the delivery LT 3000 loop testing tool for the all loop3000 installations, usable without panel installation • • • • • • • • • • • • • 30 www.detectomat.de test and programming tool for one loop direct connection to the personal computer independent operation without fire control panel loop diagnostics and the location of failures are automatically displayed in a graphic of the loop3000 devices graphical representation of the loop structure via software the loop devices are constantly analysed and the analogue values are displayed graphical display of the analogue values of smoke, contamination, temperature, loop-voltage and temperaturecompensation display of detector-type, serial-number, detector-zone with number, free customer text all datas can be exported in Excel or Word files extensive print-functions of graphics and charts configuration for all loop devices (algorithms, sensitivities, etc.) Windows based user interface the software runs on Windows 98, 2000 or XP 1. fire control panels 1.6 visualization art. 31911 demo software for visual detect VD DV • • • • • • • • • • • • demonstration kit for visualization software for fire control panels detect 3000 without active connection to a bitbus network • • • • • runs under Windows 2000/XP network compatible (server-client principle) modular structure of the software full graphic visualization simulation tool (to test the detectors and the programmed system connections) art. 30143 visual detect basic software • • • • • VD Basic 11 • • • • • • • • • • • • basic visualization software kit - basis software for one fire control panel and one work-station • • • • • • runs under Windows 2000/XP network compatible (server-client principle) modular structure of the software full graphic visualization simulation tool (to test the detectors and the programmed system connections) comprehensive operator and rights management, different user-hierarchies can be created comprehensive operator and rights management, different user hierarchies can be created free definable alarm management, procedure-plans option for automatic execution of procedure-plans German/English/Russian bilingual print function (e.g. print of fire brigade routing card, unit location plans) system consists of a development and a runtime interface help function for development and runtime interface bitbus-connection via internal ISA-bitbus card password can be modified in the log-on window data-codification between server and clients detector data can be generated and read-in via the import-tool from the dpt-program full functionality within the system in one host without an active connection to a bitbus network procedure-plan are freely defined location plans, screenshots and routing cards can be printed manual and automatically all simulated messages and their execution are recorded and can be analysed and retrieved with a filter own projects are programmable, incl. scanning of unit location plans, routing cards, places of addressed detectors and creation of procedure-briefings different user hierarchies can be created within the software by assigning individual rights • • • • • • free definable alarm management, procedure-plans option for automatic execution of procedure-plans German/English/Russian bilingual print function (e.g. print of fire brigade routing card, unit location plans) system consists of a development and a runtime interface help function for development and runtime interface bitbus-connection via internal ISA-bitbus card password can be modified in the log-on window data-codification between server and clients detector data can be generated and read-in via the import-tool from the dpt-program authorization for one work-station and one fire control panel stand-alone system possible, as data-transmission between server and client via TCP/IP protocol free creation of announcements route-plans readable in all common CAD formats screenshots und route-cards can be printed manual or automatic all simulated messages and their execution are recorded and can be analysed and retrieved with a filter own projects are programmable, incl. scanning of unit location plans, routing cards, places of addressed detectors and creation of procedure-briefings different user hierarchies can be created within the software by assigning individual rights 31 www.detectomat.de 1. fire control panels 1.6 visualization art. 30144 Visual detect user expansion VD UE 1 one workstation expansion kit - for the expansion of one workstation / user in the TCP/IP network art. 30145 • • • • Visual detect expansion panel VD PE 1 one fire control panel expansion kit - for one fire control panel in the BitBus network art. 30146 multiple workstations-expandable by one possibility to work in the network messages notification and "send messages" operator specific classificated messages and rights possible • • • Visual detect operation expansion expandable by one fire control panel unit each a maximum of 20 units can be managed operator specific classificated messages and rights possible VD CE 1 license kit - for the remote control function expansion via visualization software art. 31654 Visual detect interface management system VD M I license kit - interface to building management systems (BMS) for data support 1.7 conventional panels art. 30941 conventional fire control panel BMZ 6 • • • • • 6 quiescent current monitored detector zones maximum 30 automatic detector each zone 6 relay outputs for alarm and fault 2 monitored outputs for signalling devices 300 mA space for battery 1 x 12 V / 7 Ah technical specification conventional fire control panel with 6 detector-zones input voltage frequency operation voltage emergency power quiesent current display zone LED´s sounder output relay output operation temperature housing color material weight dimensions (H x W x D) 32 www.detectomat.de 230 V AC 50 / 60 Hz 24 V DC 1 x 12 V / 7,5 Ah 190 mA LED indications for 6 zones 2x 24V 300mA monitored 1 relay per zone -5°C up to +40°C grey ABS 2 kg 240 mm x 325 mm x 80 mm 2. detectors 2.1 loop3000 - adressable detectors art. 30009 optical smoke detector PL 3200 O • • • • • • • • • • different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity protection class housing color material dimensions (H x Ø) approvals complies with intelligent detector for loop3000, 2 optical sensors, complies with EN 54 part 7 specification • • • • • • loop3000 is a high functional detection-system superior operational reliability from intelligent analysis of the measuring chamber signal a second independent optical measuring channel a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable art. 30011 optical smoke detector, isolator PL 3300 O intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification • • • • • • • • • • • • • • • • 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators < 0,15 dB / m -10°C up to +60°C max. 95 % RH / 40°C IP 40 white ABS 44 mm x 100 mm VdS G 202003 EN 54 - 7 • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch superior operational reliability from intelligent analysis of the measuring chamber signal a second independent optical measuring channel a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics self learning mode in respect of environmental conditions recognition of the exact contamination-status • automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity protection class housing color material dimensions (H x Ø) approvals complies with 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators < 0,15 dB / m -10°C up to +60°C max. 95 % RH / 40°C IP 40 white ABS 44 mm x 100 mm VdS G 202002 EN 54 - 7 33 www.detectomat.com 2. detectors 2.1 loop3000 - adressable detectors art. 30956 optical smoke detector, isolator, white PL 3301 O white intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification, design 1, color white • features as PL 3300 O technical specification dimensions (H x Ø) approvals complies with art. 30488 optical smoke detector, isolator, silver 42 mm x 95 mm VdS G 205046 EN 54 - 7 PL 3301 O silver intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification, design 1, color silver • features as PL 3300 O technical specification dimensions (H x Ø) approvals complies with art. 30525 optical smoke detector, isolator, black 42 mm x 95 mm VdS G 205046 EN 54 - 7 PL 3301 O black intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification, design 1, color black • features as PL 3300 O technical specification dimensions (H x Ø) approvals complies with art. 30555 optical smoke detector, isolator, white 42 mm x 95 mm VdS G 205046 EN 54 - 7 PL 3304 O white intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification, design 4, color white • features as PL 3300 O technical specification dimensions (H x Ø) approvals complies with 34 www.detectomat.com 47 mm x 110 mm VdS G 204088 EN 54 - 7 2. detectors 2.1 loop3000 - adressable detectors art. 30556 optical smoke detector, isolator, silver PL 3304 O silver intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification, design 4, color silver • features as PL 3300 O technical specification dimensions (H x Ø) approvals complies with art. 30567 optical smoke detector, isolator, white 47 mm x 110 mm VdS G 204088 EN 54 - 7 PL 3305 O white intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification, design 5, color white • features as PL 3300 O technical specification dimensions (H x Ø) approvals complies with art. 30568 optical smoke detector, isolator, silver 47 mm x 110 mm VdS G 204089 EN 54 - 7 PL 3305 O silver intelligent detector for loop3000, 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification, design 5, color silver • features as PL 3300 O technical specification dimensions (H x Ø) approvals complies with 47 mm x 110 mm VdS G 204089 EN 54 - 7 35 www.detectomat.com 2. detectors 2.1 loop3000 - adressable detectors art. 32045 optical smoke detector PL 3200 O/K • • • • • • • • • • different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification intelligent detector for loop3000, specifically for the detection in air streams and in aspirating smoke systems (<20 m/sec.), 2 optical sensors, complies with EN 54 part 7 specification • • • • • • loop3000 is a high functional detection-system superior operational reliability from intelligent analysis of the measuring chamber signal a second independent optical measuring channel a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable art. 30092 optical smoke detector, isolator intelligent detector for loop3000, specifically for the detection in air streams and in aspirating smoke systems (<20 m/sec.), 2 optical sensors and bidirectional isolator, complies with EN 54 part 7 specification • • • • • • • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch superior operational reliability from intelligent analysis of the measuring chamber signal a second independent optical measuring channel a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity air speed protection class housing color material dimensions (H x Ø) approvals complies with 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators < 0,15 dB / m -10°C up to +60°C max. 95 % RH / 40°C up to 20m/sec IP 40 white ABS 44 mm x 100 mm VdS G 206 035 EN 54 - 7 PL 3300 O/K • • • • self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity air speed protection class housing color material dimensions (H x Ø) approvals complies with 36 www.detectomat.com 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators < 0,15 dB / m -10°C up to +60°C max. 95 % RH / 40°C up to 20m/sec IP 40 white ABS 44 mm x 100 mm VdS G 202 107 EN 54 - 7 2. detectors 2.1 loop3000 - adressable detectors art. 30008 heat detector PL 3200 T • • • • • • • • • • different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification intelligent detector for loop3000, 2 thermal sensors, complies with EN 54 part 5 specification • • • • • • • loop3000 is a high functional detection-system superior operational reliability from intelligent analysis of the thermo sensor temperature measurement via high sensitiv sensor maximum and rate of rise analysis with thermal sensor technology a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable art. 30010 heat detector, isolator • • • • • • • • • • • 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators 60°C or rate of rise -10°C up to +60°C max. 95 % RH / 40°C up to 20m/sec IP 43 white ABS 52 mm x 100 mm VdS G 203038 EN 54 - 5 PL 3300 T intelligent detector for loop3000, 2 thermal sensors, complies with EN 54 part 5 specification • • • • operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity air speed protection class housing color material dimensions (H x Ø) approvals complies with loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch superior operational reliability from intelligent analysis of the thermo sensor temperature measurement via high sensitiv sensor maximum and rate of rise analysis with thermal sensor technology a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics • • • • self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity air speed protection class housing color material dimensions (H x Ø) approvals complies with 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators 60°C or rate of rise -10°C up to +60°C max. 95 % RH / 40°C up to 20m/sec IP 43 white ABS 52 mm x 100 mm VdS G 203037 EN 54 - 5 37 www.detectomat.com 2. detectors 2.1 loop3000 - adressable detectors art. 30007 optical smoke and heat detector PL 3200 OT • • • • • • • • • • different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification intelligent detector for loop3000, 2 optical and 2 thermal sensors, complies with EN 54 part 5 and 7 specification • • • • • • • • loop3000 is a high functional detection-system superior operational reliability from intelligent analysis of the thermo sensor and the optical measuring chamber signal temperature measurement via high sensitiv sensor maximum and rate of rise analysis with thermal sensor technology a second independent optical measuring channel a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable art. 30021 optical smoke and heat detector, isolator intelligent detector for loop3000, 2 optical and 2 thermal sensors and bidirectional isolator, complieswith EN 54 part 5 and 7 specification • • • • • • • • • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch superior operational reliability from intelligent analysis of the thermo sensor and the optical measuring chamber signal temperature measurement via high sensitiv sensor maximum and rate of rise analysis with thermal sensor technology a second independent optical measuring channel a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity air speed protection class housing color material dimensions (H x Ø) approvals complies with 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators < 0,15 dB / m 60°C or rate of rise -10°C up to +60°C max. 95 % RH / 40°C up to 20m/sec IP 40 white ABS 52 mm x 100 mm VdS G 205052 54 - 7, 54 - 5 PL 3300 OT • • • • self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity air speed protection class housing color material dimensions (H x Ø) approvals complies with 38 www.detectomat.com 15 up to 30 V loop powered 250 µA 5 mA 10 mA for LED indicators < 0,15 dB / m 60°C or rate of rise -10°C up to +60°C max. 95 % RH / 40°C up to 20m/sec IP 40 white ABS 52 mm x 100 mm VdS G 205051 54 - 7, 54 - 5 2. detectors 2.1 loop3000 - adressable detectors art. 30079 CO gas and heat detector, isolator PL 3300 CDBT • • • • • • • • • • different sensitivities are programmable for day and night periods a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector automatic fault monitoring of the measuring chamber electronics self learning mode in respect of environmental conditions recognition of the exact contamination-status automatic adjustment of the alarm sensitivity in case of contamination multicolour-LED for alarm- (red) and fault-display (yellow) technical specification intelligent detector for loop3000, with carbon monoxid gas and 2 thermal sensors and bidirectional isolator, complies with EN 54 part 5 specification • • • • • • • • • • • operation voltage quiesent current alarm current noise loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch superior operational reliability from intelligent analysis of the thermo sensor and the carbon monoxid sensor signal temperature measurement via high sensitiv sensor maximum and rate of rise analysis with thermal sensor technology carbon monoxid measurement via industrial detection sensor pre alarm and alarm level for carbon monoxid a dedicated thermal-sensor provides a display of the detector temperature profile at the fire control panel real sensor-tests are carried out on a periodical basis detector-sensitivity is freely programmable open collector output sensitivity operation temperature humidity air speed protection class housing color material dimensions (H x Ø) complies with 15 up to 30 V loop powered 600 µA 5 mA integreated buzzer for gas alarm and pre alarm 10 mA for LED indicators 60°C or rate of rise pre alarm 30 ppm CO alarm 60 ppm CO -10°C up to +60°C max. 95 % RH / 40°C up to 20m/sec IP 43 white ABS 58 mm x 100 mm 54 - 7, 54 - 5 2.2 CT 3000 - conventional detectors art. 30015 optical smoke detector CT 3000 O technical specification conventional optical smoke detector, complies with EN 54 part 7 specification • • operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity protection class housing color material dimensions (H x Ø) approvals complies with 9 up to 33 V Dc 100 µA 20 mA 15 mA for LED indicators < 0,15 dB / m -10°C bis +60°C max. 95 % RH / 40°C IP 43 white ABS 44 mm x 100 mm VdS G 203036 54 - 7 high functional detection-system intelligent analysis of the measuring chamber signal 39 www.detectomat.com 2. detectors 2.2 CT 3000 - conventional detectors art. 30977 optical smoke detector CT 3000 O/K technical specification conventional detector, especially fot the detection in air streams and aspirating smoke systems (<20 m/sec.), with 2 optical sensors, complies with EN 54 part 7 specification • • high functional detection-system intelligent analysis of the measuring chamber signal art. 31929 optical smoke detector, white operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity protection class housing color material dimensions (H x Ø) approvals complies with 9 up to 33 V Dc 100 µA 20 mA 15 mA for LED indicators < 0,15 dB / m -10°C bis +60°C max. 95 % RH / 40°C IP 43 white ABS 44 mm x 100 mm VdS G 203035 54 - 7 CT 3001 O white conventional detector, complies with EN 54 part 7 specification, design 1 • features as CT 3000 O technical specification dimensions (H x Ø) art. 31589 optical smoke detector, silver 42 mm x 95 mm CT 3001 O silver conventional detector, complies with EN 54 part 7 specification, design 1 • features as CT 3000 O technical specification dimensions (H x Ø) art. 31926 optical smoke detector, black 42 mm x 95 mm CT 3001 O black conventional detector, complies with EN 54 part 7 specification, design 1 • features as CT 3000 O technical specification dimensions (H x Ø) 40 www.detectomat.com 42 mm x 95 mm 2. detectors 2.2 CT 3000 - conventional detectors art. 30552 optical smoke detector, silver CT 3005 O silver conventional detector, complies with EN 54 part 7 specification, design 5 • • features as CT 3000 O low profile available Technische Daten dimensions (H x Ø) low profile version art. 30551 optical smoke detector, white 47 mm x 110 mm design mount in version: art. 31684 CT 3005 O white conventional detector, complies with EN 54 part 7 specification, design 5 • • features as CT 3000 O low profile available Technische Daten dimensions (H x Ø) art. 30546 optical smoke detector, silver 47 mm x 110 mm CT 3004 O silver conventional detector, complies with EN 54 part 7 specification, design 4 • • features as CT 3000 O low profile available Technische Daten dimensions (H x Ø) 47 mm x 110 mm 41 www.detectomat.com 2. detectors 2.2 CT 3000 - conventional detectors art. 30545 optical smoke detector, white CT 3004 O white conventional detector, complies with EN 54 part 7 specification, design 4 • features as CT 3000 O technical specification dimensions (H x Ø) art. 30014 heat detector 47 mm x 110 mm CT 3000 T • • high functional detection-system intelligent analysis of the thermal sensor technical specification conventional heat detector, complies with EN 54 part 5 specification art. 30022 multisensor detector operation voltage quiesent current alarm current open collector output sensitivity operation temperature humidity protection class housing color material dimensions (H x Ø) complies with 9 up to 33 V DC 100 µA 20 mA 15 mA for LED indicators 60°C rate of rise -10°C up to +60°C max. 95 % RH / 40°C IP 43 white ABS 52 mm x 100 mm EN 54 - 5 CT 3000 OT • • • high functional detection-system intelligent analysis of the thermal sensor intelligent analysis of the measuring chamber signal technical specification operation voltage quiesent current alarm current open collector output sensitivity conventional optical smoke and heat detector, complies with EN 54 part 5 and 7 specification operation temperature humidity protection class housing color material dimensions (H x Ø) complies with 42 www.detectomat.com 9 up to 33 V DC 100 µA 20 mA 15 mA for LED indicators < 0,15 dB / m 60° rate of rise -10°C up to +60°C max. 95 % RH / 40°C IP 43 white ABS 52 mm x 100 mm EN 54 - 7, EN 54 - 5 2. detectors 2.3 detector accessoires art. 30301 detector base SDB 3000 usable for all detectors of the series loop3000 and CT, colour: white • • • standard base for all detectors of the series loop3000 and CT including LED indicator connection space for additional modules technical specification operation temperature housing color material dimensions (H x Ø) art. 30926 detector base, silver similar to detector base SBD 3000 art. 30523 detector base, black similar to detector base SBD 3000 art. 31959 detector base, bridged base for all loop3000 detectors including a bridge if the detector should be removed from the socket, colour: white • • • usable for loop3000 detectors including LED indicator connection space for additional cage clambs and modules art. 32084 detector base, bridged similar to detector base SDBB 3000 art. 32083 detector base, bridged similar to detector base SDBB 3000 art. 32114 diode base SDB 3000 silver colour: silver SDB 3000 black colour: black SDBB 3000 technical specification operation temperature housing color material dimensions (H x Ø) -10°C up to +60°C white ABS 20 mm x 95 mm SDBB 3000 silver colour: silver SDBB 3000 black colour: black CDBD 3000 usable for all detectors of the series loop3000 and CT, colour: white technical specification • • • operation temperature housing color material dimensions (H x Ø) standard base for all detectors of the series loop3000 and CT including LED indicator connection space for additional modules -10°C up to +60°C white ABS 20 mm x 95 mm -10°C up to +60°C white ABS 20 mm x 95 mm 43 www.detectomat.com 2. detectors 2.3 detector accessoires art. 30469 detector relay base DRB 3000 detector base with integreated relay to connect to external devices colour: white • • • detector relays base to connect to external devices the relay will be activated directly from the detector alarm output potential-free change over contact technical specification relay output operation temperature housing color material dimensions (H x Ø) approvals art. 32086 detector relay base similar to detector relay base DRB 3000 art. 32085 detector relay base similar to detector relay base DRB 3000 art. 32091 piezo buzzer for detectors change over 30 V / 1 A -10°C up to +60°C white ABS 20 mm x 95 mm BMA 06/0363-A = pending DRB 3000 silver colour: silver DRB 3000 black colour: black Sockel Piezo • • • • additional buzzer for detectors of the series loop3000 and CT activated by open collector output noise volume 85 dB - distance 0,3 meter powered by the detector technical specification operation voltage noise operation temperature housing color material dimensions (H x W x D) 44 www.detectomat.com 15 up to 33 V DC 85 dB / 0,3 m -10°C up to +60°C white ABS 8 mm x 45 mm x 35 mm 2. detectors 2.3 detector accessoires art. 31698 wall mount base adapter APS usable as wall mount kit for all detector bases for on wall wire installations • • wire entries at the side internal space for additional modules technical specification operation temperature housing color material dimensions (H x Ø) -10°C up to +60°C white ABS 28 mm x 110 mm remarks: • it is essential to specifying the right base for this kit • no socket included art. 31181 base for humid areas FRS • • • universally applicable for damp locations wire entries at the side M25 screw fitting included technical specification operation temperature housing color material dimensions (H x Ø) usable as wall mount kit for all detector bases for difficult and humid envirements art. 31191 housing for air ducts -10°C up to +60°C white ABS 40 mm x 110 mm remarks: • it is essential to specifying the right base for this kit • no socket included LKMG • • • • • including pipe for ingress and outlet air sampling ingress of air pipe length: 210 mm for air ducts up to 350 mm length special lengths for ingress of air pipes possible without detector base technical specification operation temperature air speed housing colour material dimensions (H x W x D) housing with test-box and sensor-pipe to monitore air streams with optical detectors of the series loop3000 and CT -10°C up to +60°C 1 up to 25m/s grey ABS 200 mm x 110 mm x 92 mm remarks: • it is essential to specifying the right base for this kit • no socket included 45 www.detectomat.com 2. detectors 2.3 detector accessoires art. 31875 base with heating APSB usable as wall mount kit with monitored heating for all detector bases for difficult and humid envoirements • • additional on-wall base with temperature controlled heating usable in installations up to - 30°C technical specification operation voltage quiesent current external user output operation temperature housing color material weight dimensions (H x Ø) 24 V DC 160 mA 4W heating -30°C up to +60°C white ABS 335 g 55 mm x 110 mm remarks: • it is essential to specifying the right base for this kit • no socket included art. 31684 flush-mounting adapter silver DR45 usable as mount in kit to semi-recess detectors of the design 4 and 5 in ceilings, color silver • • • flush mounting base kit for detectors design 4 and 5 of the series loop3000 and CT usable in installations in lower ceilings ceiling hole diameter 120mm technical specification operation temperature housing color material dimensions (H x Ø) -10°C up to +60°C silver sheet steel 35 mm x 165 mm remarks: it is essential to specifying the right base for this kit art. 32070 flush-mounting adapter white usable as mount in kit to semi-recess detectors of the design 4 and 5 in ceilings, color white • • • flush mounting base kit for detectors design 4 and 5 of the series loop3000 and CT usable in installations in lower ceilings ceiling hole diameter 120mm DR45W technical specification operation temperature housing color material dimensions (H x Ø) -10°C up to +60°C white sheet steel 35 mm x 165 mm remarks: it is essential to specifying the right base for this kit 46 www.detectomat.com 2. detectors 2.3 detector accessoires art. 30479 labelling tag for detector base MBC usable for all detector bases of the series loop3000 and CT colour: white • • fixing via plug in selling-packages at 30 pieces technical specification operation temperature colour material dimensions (H x W) art. 30187 detector mounting adapter -10°C up to +60°C white ABS 28 mm x 45 mm MKBD for an distanced installation of all detector bases to ceilings or walls • • infinitely adjustable 270 to 480 mm detector mounting-plate infinitely inclinable 0° until 110° technical specification colour material dimensions (H x W x D) art. 30188 detector flap-mounting adapter light grey, RAL 7035 sheet steel 135 mm x 100 mm x 270 - 480 mm MKK for an distanced installation of all detector bases to ceilings or walls • inclinable 0° until 110° technical specification colour material dimensions (H x W x D) light grey, RAL 7035 sheet steel 150 mm x 117 mm x 13 - 154 mm 47 www.detectomat.com 2. detectors 2.3 detector accessoires art. 30189 detector distance-mounting adapter MAK for an distanced installation of all detector bases to ceilings or walls • • panel for mounting automatic fire detectors in lowered ceilings ceiling distance 80 mm technical specification colour material dimensions (H x W x D) art. 30190 wall bracket light grey, RAL 7035 sheet steel 80 mm x 138 mm x 100 mm WA4 for an distanced installation of all detector bases to ceilings or walls • • for mounting of automatic fire detectors, for example over fire protected doors distance to the wall: 400 mm technical specification colour material dimensions (H x W x D) art. 30191 wall bracket light grey, RAL 7035 sheet steel 50 mm x 100 mm x 400 mm WA2 for an distanced installation of all detector bases to ceilings or walls • • for mounting of automatic fire detectors, for example over fire protected doors distance to the wall: 200 mm technical specification colour material dimensions (H x W x D) 48 www.detectomat.de light grey, RAL 7035 sheet steel 50 mm x 100 mm x 200 mm 3. manual call points 3.1 loop3000 - addressable manual call points art. 31669 manual call point, ABS PL 3300 PBDH-ABS-R intelligent manual call point for loop3000, ABS, red, with bidirectional isolator • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector multicolour-LED for alarm technical specification operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with art. 31059 manual call point, ABS 15 up to 30 V loop powered 250 µA 5 mA -10°C up to +60°C IP 42 red, RAL 3000 ABS 125 mm x 125 mm x 35 mm VdS G 203021 EN 14655 PL 3300 PBD-ABS-B intelligent manual call point for loop3000, ABS, blue, with bidirectional isolator • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector multicolour-LED for alarm technical specification operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 15 up to 30 V loop powered 250 µA 5 mA -10°C up to +60°C IP 42 blue ABS 125 mm x 125 mm x 35 mm VdS G 203021 EN 14655 49 www.detectomat.de 3. manual call points 3.1 loop3000 - addressable manual call points art. 31060 manual call point, ABS PL 3300 PBD-ABS-Y intelligent manual call point for loop3000, ABS, yellow, with bidirectional isolator • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector multicolour-LED for alarm technical specification operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with art. 31668 manual call point, ALU 15 up to 30 V loop powered 250 µA 5 mA -10°C up to +60°C IP 42 yellow ABS 125 mm x 125 mm x 35 mm VdS G 203021 EN 14655 PL 3300 PBDH-ALU-R intelligent manual call point for loop3000, ALU, red, with bidirectional isolator • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector multicolour-LED for alarm technical specification operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 50 www.detectomat.com 15 up to 30 V loop powered 250 µA 5 mA -10°C up to +60°C IP 42 red, RAL 3000 aluminium 125 mm x 125 mm x 34 mm VdS G 203021 EN 14655 3. manual call points 3.1 loop3000 - addressable manual call points art. 31061 manual call point, ALU PL 3300 PBD-ALU-B intelligent manual call point for loop3000, ALU, blue, with bidirectional isolator • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector multicolour-LED for alarm technical specification operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) complies with art. 31062 manual call point, ALU 15 up to 30 V loop powered 250 µA 5 mA -10°C up to +60°C IP 42 blue aluminium 125 mm x 125 mm x 34 mm EN 14655 PL 3300 PBD-ALU-Y intelligent manual call point for loop3000, ALU, yellow, with bidirectional isolator • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector multicolour-LED for alarm technical specification operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) complies with 15 up to 30 V loop powered 250 µA 5 mA -10°C up to +60°C IP 42 yellow aluminium 125 mm x 125 mm x 34 mm EN 14655 51 www.detectomat.com 3. manual call points 3.1 loop3000 - addressable manual call points art. 32065 manual call point PL 3300 MCP-kit • • • • • addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector technical specification intelligent manual call point for loop3000, ABS red, labeled symbol: "burning house", with bidirectional isolator • • loop3000 is a high functional detection-system including bidirectional short circuit isolator art. 30569 manual call point, chinese intelligent manual call point for loop3000, ALU red, labeled symbol: "Fire Alarm", with bidirectional isolator operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 15 up to 30 V loop powered 370 µA 5 mA -10°C up to +60°C IP 42 red, RAL 3000 ABS 88 mm x 88 mm x 54 mm LPCB 166b/8 EN 54 PL 3300 MCP-kit • multicolour-LED for alarm technical specification • • • • • • • • • • chinese version 2 LED displays for operation and alarm 1 output for evacuation systems loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch a log of the last maintenance date is stored automatic addressing (soft-addressing) manual addressing (EasyCheck) outputs for alarm and fault condition indication at the detector operation voltage quiesent current alarm current operation temperature protection class housing color material dimensions (H x W x D) complies with 15 up to 30 V loop powered 250 µA 5 mA -10°C up to +60°C IP42 red, RAL 3000 ABS 125 mm x 125 mm x 34 mm CCC 3.2 CT 3000 - conventional call points art. 31675 manual call point, ABS, red CT 3000 PBDH-ABS-R conventional manual call point for the series CT3000 • LED indicator for alarm, housing ABS technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 52 www.detectomat.com 12 up to 24 V DC 27 mA -10°C up to +60°C IP 42 red, RAL 3000 ABS 125 mm x 125 mm x 34 mm VdS G296033 EN 54 3. manual call points 3.2 CT 3000 - conventional call points art. 31651 manual call point, ABS, blue CT 3000 PBD-ABS-B conventional manual call point for the series CT3000 • LED indicator for alarm, housing ABS technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) complies with art. 31676 manual call point, ALU, red 12 up to 24 V DC 27 mA -10°C up to +60°C IP 42 blue ABS 125 mm x 125 mm x 34 mm EN 54 CT 3000 PBDH-ALU-R conventional manual call point for the series CT3000 • LED indicator for alarm, housing aluminium technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with art. 31087 manual call point, ALU, blue 12 up to 24 V DC 27 mA -10°C up to +60°C IP 42 red, RAL 3000 aluminium 125 mm x 125 mm x 34 mm VdS G 202034 EN 54 CT 3000 PBD-ALU-BD conventional manual call point for the series CT3000 • LED indicator for alarm, housing aluminium technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) complies with 12 up to 24 V DC 27 mA -10°C up to +60°C IP 42 blue aluminium 125 mm x 125 mm x 34 mm EN 54 53 www.detectomat.com 3. manual call points 3.2 CT 3000 - conventional call points art. 31088 manual call point, ALU, yellow CT 3000 PBD-ALU-YD conventional manual call point for the series CT3000 • LED indicator for alarm, housing aluminium technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with art. 31083 manual call point, IP 66, red 12 up to 24 V DC 27 mA -20°C up to +70°C IP 42 yellow aluminium 125 mm x 125 mm x 34 mm VdS G 205 018 EN 54 CT 3000 PDB-IP66-R conventional manual call point for the series CT3000, IP 66 protected for critical envoirements • • • • LED indicator for alarm housing ABS waterdust and proof IP 66 two switching contacts connectable on loop3000 via AMD3311 technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with art. 32082 manual call point, ABS, red 19 up to 28 V DC 20 mA -20°C up to +80°C IP 66 red, RAL 3000 aluminium 135 mm x 145 mm x 70 mm VdS G 295025 EN 54 SBDH-ABS-R conventional manual call point for the series CT3000 technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 54 www.detectomat.com 9 up to 33 V DC 27 mA -10°C up to +60°C IP 42 red, RAL 3000 ABS 88 mm x 88 mm x 54 mm LPCB 166b/8 EN 54 3. manual call points 3.3 accessoires for manual call points art. 31091 weatherproof housing WG-R in red for aluminium manual call points • • usable to reach protection level IP 54 including fitting kit technical specification housing color material dimensions (H x W x D) art. 31092 weatherproof housing red, RAL 3000 aluminium 145 mm x 131 mm x 55 mm WG-B in blue for aluminium manual call points • • usable to reach protection level IP 54 including fitting kit technical specification housing color material dimensions (H x W x D) • art. 40054 key for manual call point HFM-SCH-M art. 31910 glass for manual call point HFM EG art. 31069 • glass for manual call point labeled with blue circle art. 30026 • dimensions (H x W) unlabeled glass for manual call point labeled with yellow circle blue aluminium 145 mm x 131 mm x 55 mm 80 mm x 80 mm HFM EG-B dimensions (H x W) 80 mm x 80 mm HFM EG-G dimensions (H x W) 80 mm x 80 mm 55 www.detectomat.com 4. loop3000 modules art. 30200 in-/output module IOM 3311 intelligent input output module for loop3000 with bidirectional isolator in a housing • • • • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch 1 monitored input to connect external devices to the loop3000 1 potential-free output to control external devices in- and output are freely programmable automatic addressing (soft-addressing) manual addressing (EasyCheck) multicolour-LED for alarm- (red) and fault-display (yellow) technical specification operation voltage quiesent current alarm current relay output operation temperature protection class housing color material dimensions (H x W x D) approvals complies with art. 32073 extension module 15 up to 30 V loop powered 500 µA 5 mA change over 30 V / 1 A -10°C up to +60°C IP 54 grey, RAL 7035 ABS 93 mm x 93 mm x 55 mm VdS G 205029 EN 54 UBW 3311 extension module for the realisation of controlled outputs via the IOM3311 or the OMS3301 • • • • • 1 monitored output with broken wire- and short circuit monitoring maximum current 1 A via external supply convenient for the monitored connection of signaling devices directly connectable in the housing of the IOM3311 or OMS3301 external powered technical specification operation voltage quiesent current alarm current sounder output operation temperature dimensions (H x W x D) approvals complies with 56 www.detectomat.com 24V DC 11 mA up to 1A up to 1A -10°C up to +60°C 20 mm x 38 mm x 35 mm pending EN 54 4. loop3000 modules art. 30211 output module OMS 3301 • • • • • 1 potential-free output to control external devices the relays can be reset at the fire control panel via "external sounder on/off" output is freely programmable automatic addressing (soft-addressing) manual addressing (EasyCheck) technical specification operation voltage quiesent current alarm current relay output operation temperature protection class housing color material dimensions (H x W x D) approvals complies with intelligent sounder-control-module for loop3000 including bidirectional isolator • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch art. 30513 mini in-/output module 15 up to 30 V loop powered 500 µA 5 mA change over 30 V / 1 A -10°C up to +60°C IP 54 grey, RAL 7035 ABS 93 mm x 93 mm x 55 mm VdS G 205030 EN 54 AMD 3311 • • • automatic addressing (soft-addressing) manual addressing (EasyCheck) poured ciruit board version technical specification intelligent input output module for loop3000 with bidirectional isolator in mini version • • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch 1 monitored input to connect external devices to the loop3000 1 open collector output to control external devices in- and output are freely programmable art. 31640 mini output module operation voltage quiesent current alarm current open collector output operation temperature housing color dimensions (H x W x D) approvals complies with 15 up to 30 V loop powered 370 µA 5 mA 500 mA -10°C up to +60°C blue 27 mm x 73 mm x 15 mm VdS G 206047 EN 54 OMS 3301mini • • • automatic addressing (soft-addressing) manual addressing (EasyCheck) poured ciruit board version technical specification intelligent sounder-control-module for loop3000 including bidirectional isolator • • • • • loop3000 is a high functional detection-system including bidirectional short circuit isolator addressable spur connection via T-branch 1 open collector output to control external devices output is freely programmable operation voltage quiesent current alarm current open collector output operation temperature housing color dimensions (H x W x D) complies with 15 up to 30 V loop powered 370 µA 5 mA 500 mA -10°C up to +60°C blue 27 mm x 73 mm x 15 mm EN 54 57 www.detectomat.com 4. loop3000 modules art. 32074 in-/output module mini AOM 3301 intelligent module for loop3000 including bidirectional isolator • • • • • • • • • loop3000 is a high functionality detection-system including bidirectional short circuit isolator addressable spur connection via T-branch 1 monitored input to connect external devices to the loop3000 1 monitored output to control external devices in- and output are freely programmable automatic addressing (soft-addressing) manual addressing (EasyCheck) ciruit board version technical specification operation voltage quiesent current alarm current external user output operation temperature dimensions (H x W x D) complies with art. 30205 conventional zone module 15 up to 30 V loop powered 370 µA 5 mA 5 mA monitored -10°C up to +60°C 27 mm x 73 mm x 15 mm EN 54 TCM 3300 intelligent module for loop3000 for connection of 1 zone of conventional detectors, including bidirectional isolator • • • • • • • • detector zone interface with high functionality for loop3000 integrated bidirectional short circuit isolator addressable spur connection via T-branch variable adjustable of short circuit-, break wire-, pre-alarm- and alarm threshold external power supply of 12 / 24 volt automatic addressing (soft-addressing) manual addressing (EasyCheck) multicolour-LED for alarm- (red) and fault-display (yellow) technical specification operation voltage quiesent current alarm current external user output operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 58 www.detectomat.com 15 up to 30 V loop powered 500 µA 5 mA per zone 12 / 24 V 10 mA + zone current -10°C up to +60°C IP 54 grey, RAL 7035 ABS 93 mm x 93 mm x 55 mm VdS G 206048 EN 54 5. loop3000 - radio extension art. 30025 wireless gateway WGW 3300 • • • • • • • • • 5 radio-channels and 2 emergency-channels 433/868 MHz with changeover operation up to 32 wireless devices can be connected per gateway analogue values of the detectors can be shown via the detectomat fire control panel the detectomat fire control panel can allocate the plaintext and zones of the devices meets the requirements of BS 5839, EN 54 and VdS common alarm and fault relays for stand alone operation separate current supply and emergency power supply integrated emergency power supply by commercial standard AA-batteries up to 10 gateways in one radio nit can be integrated without quality loss technical specification frequency operation voltage emergency power quiesent current display relay output intelligent wireless gateway for loop3000 to connect wireless detectors/-modules, including bidirectional isolators • • • • • a high functionality wireless extention to the loop3000 for the integration of wireless detectors and -modules including bidirectional short circuit isolator as loop-module programming and status is displayed by a 4 x 20 character display keyboard consists of 16 keys for controlling and programming art. 30003 wireless optical smoke detector operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 2 x 433 MHz, 5 x 868 MHz 24 V DC external batteries 8 x AA Mignon 20 mA 4 x 20 characters alarm 30 V / 1 A fault 30 V / 1 A -10°C up to +60°C IP 65 grey, RAL 7035 ABS 200 mm x 120 mm x 77 mm VdS pending, LPCB, E 120684/1.1, TE 226593 EN 54 - 25 WL 3200 O intelligent wireless optical smoke detector for loop3000 • • • • • high functionality detection system for loop3000 equivilant to loop-device in conjunction with gateway WGW 3300 power supplied by 2 pieces of commercial standard C-batteries battery lifetime approximatley 3 years a programmable piezo-sounder is included technical specification frequency operation voltage operation temperature protection class housing color material dimensions (H x Ø) approvals complies with 2 x 433 MHz, 5 x 868 MHz 3 V, 2 x MX1400 LR 14 Duracell -10°C up to +60°C IP 42 white ABS 65 mm x 100 mm VdS pending, LPCB, E 120684/1.1, TE 226593 EN 54 - 7 59 www.detectomat.com 5. loop3000 - radio extension art. 32005 antenna for extended range WGA 3200 external antenna for the wireless gateway WGW 3300 • antenna for the improvement of the radio-field quality and range in intricate area conditions technical specification dimensions (H x W x D) art. 31627 wireless input module 490 mm x 270 mm x 330 mm WL 3210 EM • • • • • • • equivilant to loop-device in conjunction with gateway WGW 3300 stand-alone addressed during universal operation power supplied by commercial standard A mignon battery lifetime approximatley 3 years 1 monitored input, freely programmable via the detectomat fire control panel integrated alarm-sound an activation-module, e.g. a manual call point or a similar device can be separated up to 5 m technical specification intelligent input module for loop3000 • high functionality detection system for loop3000 frequency operation voltage operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 60 www.detectomat.com 2 x 433 MHz, 5 x 868 MHz 3 V, 2 x MX1400 LR 14, Duracell -10°C up to +60°C IP 54 grey, RAL 7035 ABS 93 mm x 93 mm x 55 mm LPCB, E 120684/1.1, TE 226593 EN 54 5. loop3000 - radio extension art. 31626 radio field analyzer RFA 3000 with the possibility to switch between sending and receiving-mode • • • • • • • radio filed intensity analyzer (1 pair) to identify the best installation area of the detectomat wireless devices battery operated unit 2 x AA-batteries) separate antenna for 433 and 868 MHz LED signal strength gage-display the measurements can be transferred to a personal computer via a serial interface (optional) LED display for sending, receiving and frequency-band technical specification frequency operation voltage protection class housing color material dimensions (H x W x D) 20 x 433 MHz, 4 x 868 Hz 3 V, 2 x AA IP 30 grey, RAL 7035 ABS 195 mm x 66 mm x 27 mm 61 www.detectomat.com 6. special detectors 6.1 aspiration smoke detectors art. 31114 Stratos HSSD-2 standard detector HSSD-2 M • • • • • • • sensitivity adjustable: 0,002 - 25 % obs/m max. 1600 mÇ (one fire compartment) can be monitored max. length of aspiration-pipes: 200 m with 100 bore holes or 250 m with 80 bore holes LC display 2 x 16 characters, cursor key control panel integrated dust filter meets the requirements of the VdS up to 127 STRATOS devices can be connected in a network by the integrated RS 485 uninterruptible external current supply 24 V DC technical specification operation voltage quiesent current interfaces display relay output sensitivity operation temperature protection class housing color material dimensions (H x W x D) approvals complies with intelligent smoke detector for building a highly sensitive asirating smoke system for earliest fire detection • • • Stratos HSSD-2 standard detector without display intelligent smoke detector for building a highly sensitive asirating smoke system for earliest fire detection, without display • • • • • • • • • • remarks: • the project engineering guidelines of the manufacturer has to be considered by the planning of the system • all project engineering documents have to be signed by detectomat GmbH for the earliest detection of fire by a laser-detector-chamber with patented artificial intelligence "classifire" to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions art. 31867 for the earliest detection of fire by a laser-detector-chamber with patented artificial intelligence "classifire" to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions sensitivity adjustable: 0,002 - 25 % obs/m max. 1600 mÇ (one fire compartment) can be monitored max. length of aspiration-pipes: 200 m with 100 bore holes or 250 m with 80 bore holes LC display for operation, alarm and fault integrated dust filter meets the requirements of the VdS up to 127 STRATOS devices can be connected in a network by the integrated RS 485 uninterruptible external current supply 24 V DC 24 V DC 400 mA RS 485 2 x 16 characters 3 (alarm, pre-alarm, fault) (0,002 - 25) % obs / m (0,0003 - 10) µm -10°C up to +60°C IP 50 light grey aluminium 372 mm x 427 mm x 95 mm VdS G 203024, LPCB, CCC EN 54 - 13 HSSD-2 MOD technical specification operation voltage quiesent current interfaces zone LED´s relay output sensitivity operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 62 www.detectomat.com 24 V DC 400 mA RS 485 4 x LED indicators for operation, alarm, fault 3 (alarm, pre-alarm, fault) (0,002 - 25) % obs / m (0,0003 - 10) µm -10°C up to +60°C IP 50 light grey sheet steel 372 mm x 427 mm x 105 mm VdS G 203 024 EN 54 - 13 6. special detectors 6.1 aspiration smoke detectors art. 31115 Stratos HSSD-2 standard detector and control module technical specification intelligent smoke detector for building a highly sensitive asirating smoke system for earliest fire detection, including command module • • • • • • • • • • • for the earliest detection of fire by a laser-detector-chamber with patented artificial intelligence "classifire" with the command module all networking STRATOS devices of one system can be programmed as well as there status can be displayed to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions sensitivity adjustable: 0,002 - 25 % obs/m max. 1600 mÇ (one fire compartment) can be monitored max. length of aspiration-pipes: 200 m with 100 bore holes or 250 m with 80 bore holes LC display 8 x 16 characters, cursor key control panel integrated dust filter meets the requirements of the VdS up to 127 STRATOS devices can be connected in a network by the integrated RS 485 uninterruptible external current supply 24 V DC art. 31117 Stratos HSSD-2 control module command module for programming and displaying all in the network connected STRATOS components • • • LC display 8 x 16 characters, cursor key control panel up to 127 STRATOS devices can be connected in a network by the integrated RS 485 uninterruptible external current supply 24 V DC art. 31953 Stratos HSSD-2 control module 19" command module in 19" for programming and displaying all in the network connected STRATOS components • • • LC display 8 x 16 characters, cursor key control panel up to 127 STRATOS devices can be connected in a network by the integrated RS 485 uninterruptible external current supply 24 V DC HSSD-2 M-S operation voltage quiesent current interfaces display relay output sensitivity operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 24 V DC 400 mA RS 485 8 x 16 characters 3 (alarm, pre-alarm, fault) (0,002 - 25) % obs / m (0,0003 - 10) µm -10°C up to +60°C IP 50 grey aluminium 372 mm x 427 mm x 95 mm VdS G 203024, LPCB, CCC EN 54 - 13 remarks: • the project engineering guidelines of the manufacturer has to be considered by the planning of the system • all project engineering documents have to be signed by detectomat GmbH HSSD-2 S technical specification operation voltage quiesent current interfaces display operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 24 V DC 450 mA RS 485 8 x 16 Zeichen -10°C up to +60°C IP 50 grey aluminium 372 mm x 427 mm x 95 mm VdS G 203024, LPCB, CCC EN 54 - 13 HSSD-2 S 19" technical specification operation voltage quiesent current interfaces display operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 24 V DC 450 mA RS 485 8 x 16 Zeichen -10°C up to +60°C IP 50 grey aluminium 3HE mm x 19“ x 95 mm VdS G 203024, LPCB, CCC EN 54 - 13 remarks: without housing 63 www.detectomat.com 6. special detectors 6.1 aspiration smoke detectors art. 31476 Stratos Micra 100 including mounting base Micra 100 • • • • • • max. length of aspiration-pipes: 100 m (2 x 50 m, each with max. 25 bore holes) LC display for operation, alarm, fault integrated dust filter up to 127 STRATOS devices can be connected in a network by the integrated RS 485 uninterruptible external current supply 24 V DC mounting base including connecting flange to ensure the recirculation technical specification operation voltage quiesent current interfaces zone LED´s intelligent aspirating smoke system for building a highly sensitive asirating smoke system for earliest detection, without display • • • • for the earliest detection of fire by a laser-detector-chamber with patented artificial intelligence "classifire" to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions sensitivity adjustable: 0,002 - 25 % obs/m art. 31118 Stratos Micra 25 including mounting base relay output sensitivity operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 26 V DC 400 mA RS 485 4 x LED indicators for operation, alarm, fault 3 (alarm, pre-alarm, fault) (0,002 - 25) % obs/m (0,0003 - 10) µm -10°C up to +60°C IP 51 grey aluminium 180 mm x 300 mm x 85 mm LPCB EN 54 - 13 Micra 25 • • • • • • max. length of aspiration-pipes: 50 m (25 m at highest sensitivity) LC display for operation, alarm, fault integrated dust filter up to 127 STRATOS devices can be connected in a network by the integrated RS 485 uninterruptible external current supply 24 V DC mounting base including connecting flange to ensure the recirculation technical specification operation voltage quiesent current interfaces zone LED´s intelligent aspirating smoke system for building a highly sensitive asirating smoke system for earliest detection, without display • • • • for the earliest detection of fire by a laser-detector-chamber with patented artificial intelligence "classifire" to monitor clean-rooms as well as contaminated areas and also in areas, which are used by vehicles with combustion motor highest sensitivity, optimal alarm threshold and low false alarm rates are ensured by the automatic adjustment to the respective area conditions sensitivity adjustable: 0,002 - 25 % obs/m relay output sensitivity operation temperature protection class housing color material dimensions (H x W x D) approvals complies with 64 www.detectomat.com 26 V DC 250 mA RS 485 3 x LED indicators for operation, alarm, fault 3 (alarm, pre-alarm, fault) (0,002 - 25) % obs/m (0,0003 - 10) µm -10°C up to +60°C IP 51 grey aluminium 175 mm x 135 mm x 80 mm LPCB EN 54 - 13 6. special detectors 6.1 aspiration smoke detectors art. 30078 aspiration smoke detector aspiration housing to insert one or two conventional or addressable optical smoke detectors • • • • • • • • applicable in the serial loop3000 and CT 3000 directly connectable to the loop3000 with IOM 3311 2 outputs for alarm and one fault relays pipe system with 25 mm pipe connectable, maximum length 100 m the aspiration pipe is permanent monitored LED display for operation, alarm and fault dust filter is included in the delivery uninterruptible external current supply 24 V DC ASD-20 technical specification input voltage operation temperature stock temperature humidity housing color weight material dimensions (H x W x D) 24 V DC -10°C up to +60°C -10°C up to +70°C < 95 % grey, RAL9999 4000 g polycarbonat 314 mm x 254 mm x 115 mm remarks: apirating pipe systems made of PVC are applicable and can be ordered by the local wholesalers art. 32076 aspiration smoke detector ASD-01 aspiration housing to insert one or two conventional or automatic detectors • • • • • • • • applicable in the serial loop3000 and CT 3000 directly connectable to the loop3000 with IOM 3311 2 outputs for alarm and one fault relays pipe system with 25 mm pipe connectable, maximum length 50 m the aspiration pipe is permanent monitored LED display for operation, alarm and fault dust filter is included in the delivery uninterruptible external current supply 24 V DC technical specification input voltage operation temperature humidity dimensions (H x W x D) 24 V DC -10°C up to +60°C 10 up to 95 % RH 165 mm x 250 mm x 240 mm remarks: apirating pipe systems made of PVC are applicable and can be ordered by the local wholesalers 6.2 accessoires for smoke detectors art. 31133 Stratos asirating pipe 3/4" STR-R halogen-free aspiration-pipe for STRATOS aspiration smoke system • • • • • 3 m pipe material plastic, halogen-free, red low coefficient of thermal expansion great flexibility at high capacity refractiveness against chemicals technical specification colour material dimensions (H x Ø) rot ABS, 3 m x 3/4" 65 www.detectomat.com 6. special detectors 6.2 accessoires for smoke detectors art. 31135 Stratos 45° deg elbow pipe STR-W45 technical specification colour material dimensions (Ø) art. 31136 Stratos 90° bend red ABS 3/4" STR-B90 technical specification colour material dimensions (Ø) art. 31138 Stratos socket red ABS 3/4" STR-M technical specification colour material dimensions (Ø) art. 31140 Stratos T-piece red ABS 3/4" STR-T technical specification colour material dimensions (Ø) art. 31141 Stratos socket union red ABS 3/4" STR-V technical specification colour material dimensions (Ø) art. 31143 Stratos end cap red ABS 3/4" STR-E technical specification colour material dimensions (Ø) 66 www.detectomat.com red ABS 3/4" 6. special detectors 6.2 accessoires for smoke detectors art. 31948 Stratos adapter 3/4" female to 25 mm male STR-R3/4”-25 technical specification colour material dimensions (Ø) art. 31949 Stratos 25 mm female to 3/4" male adapter red ABS 3/4" x 25 mm STR-R26-3/4” technical specification colour material dimensions (Ø) art. 31950 Stratos socket 3/4" to 25 mm female red ABS 25 mm x 3/4" STR-RM5 technical specification colour material dimensions (Ø) art. 32050 Stratos ABS-socket 3/4" to 25 mm red ABS 3/4" x 25 mm STR-RH technical specification colour material dimensions (Ø) approvals art. 31613 Stratos plug sampling point assembly black ABS 3/4" x 25 mm VdS G 206 034 STR-SK technical specification colour material dimensions (Ø) white ABS 3/4" 67 www.detectomat.com 6. special detectors 6.2 accessoires for smoke detectors art. 31155 Stratos in-line smapling point STR-KK technical specification colour material dimensions (Ø) art. 31156 Stratos patress sampling point white ABS 3/4" STR-KB Mit Befestigungsflasch technical specification colour material dimensions (Ø) art. 31153 Stratos in-line remote sampling point adapter white ABS 3/4" STR-MK technical specification colour material dimensions (Ø) art. 31154 Stratos end cap adaptor red ABS 3/4" - 10 mm STR-EK technical specification colour material dimensions (Ø) art. 31151 Stratos nylon tube, red red ABS 3/4" - 10 mm STR-KR technical specification housing color material dimensions (Ø) 68 www.detectomat.de red Nylon 10 mm - 3/4" 6. special detectors 6.2 accessoires for smoke detectors art. 31152 Stratos nylon tube, white STR-KW technical specification color material dimensions (Ø) art. 31145 Stratos pipe clip, red white nylon 10 mm STR-C technical specification color material art. 31146 Stratos pipe clip black STR-CA art. 31960 Stratos flange nut STR-CM art. 31148 Stratos pipe cleaner STR-RE Stratos ABS solvent cement STR-SK red ABS M8 x 60 mm 500 ml art. 31147 for ABS-pipe, 250 ml art. 31149 Stratos sampling hole warning stickers STR-WA to mark the aspiration drilling points, Selling-packages at 100 pieces 69 www.detectomat.com 6. special detectors 6.3 infrared beam detectors art. 30473 infrared beam detector SPB-E IR BD • • • • range 5 - 100 m monitored area and mounting meets DIN VDE 0833 potential-free relays for alarm and fault three sensitivities: 25, 50 and 70 % technical specification operation voltage quiesent current alarm current relay output operation temperature humidity housing color material weight dimensions (H x W x D) approvals sender- and receiver unit • • connectable on the loop3000 via IOM3311 light and dark smoke can be detected art. 31096 reset module reset-board for the use in the loop to control the SB-E IR BD RM95 • • by voltage supply interruption the external detectors can be reset for a system compatible resetting of the detector after abrogate the alarm criterion to connect to the opto-output of the input-module circuit board with connectin clamp included in delivery • • art. 31095 infrared beam detector 15 up to 33 V DC 280 µA 20 mA 2 -10°C up to +50 °C max. 95 % white ABS transmitter 450 g, reciever 450 g 145 mm x 100 mm x 86 mm VdS G 295004 FR 2000 • • • • • light and dark smoke can be detected range 5 - 100 m monitored area and mounting meets DIN VDE 0833 potential-free relays for alarm and fault three sensitivities: 25, 35 and 50 % technical specification sender, receiver and separate analyser • connectable on the loop3000 via IOM3311 operation voltage quiesent current alarm current relay output operation temperature stock temperature protection class housing color colour Frontfolie material weight control unit dimensions (H x W x D) approvals complies with 70 www.detectomat.com 11,5 up to 28 V DC 14 mA 22 mA 2 x 30 V DC / 1 A -20°C up to +55° C -25°C up to +60°C IP 50 grey grey sheet steel 2140 g 265 mm x 210 mm x 85 mm VdS G 297058 EN 54 - 12 6. special detectors 6.3 infrared beam detectors art. 30474 infrared beam detector SRA-ET IR BD-R • • monitored area and mounting meets DIN VDE 0833 conventional detector (current increase) technical specification sender and receiver in a single housing including reflector • • • connectable on the loop3000 via TCM3300 light and dark smoke can be detected range 5 - 30 m art. 31861 infrared beam detector operation voltage quiesent current alarm current operation temperature humidity housing color material weight dimensions (H x W x D) approvals 15 up to 30 V DC 350 µA 50 mA -10°C up to +50°C max. 95 % white ABS 700 g 125 mm x 122 mm x 80 mm VdS G 200080 FR 50 RV • • • • range 5 - 50 m monitored area and mounting meets DIN VDE 0833 potential-free relays for alarm and fault three sensitivities: 25, 35 and 50 % technical specification sender and receiver in a single housing including one prism • • connectable on the loop3000 via IOM3311 light and dark smoke can be detected art. 31486 infrared beam detector operation voltage quiesent current alarm current relay output operation temperature stock temperature protection class housing color material weight dimensions (H x W x D) approvals complies with FR 100 RV sender and receiver in a single housing including four prism technical specification • • • • • • operation voltage quiesent current alarm current relay output operation temperature stock temperature protection class housing color material weight dimensions (H x W x D) approvals connectable on the loop3000 via IOM3311 light and dark smoke can be detected range 5 - 100 m monitored area and mounting meets DIN VDE 0833 potential-free relays for alarm and fault three sensitivities: 25, 35 and 50 % (picture similar to art. 31861) 10,2 up to 30 V DC 4 mA 15 mA 2 x 30 V DC / 1 A -30°C up to +55°C -35°C up to +60°C IP 50 grey ABS 670 g 117 mm x 210 mm x 120 mm VdS G 203070 EN 54 - 12 10,2 up to 30 V DC 4 mA 15 mA 2 x 30 V DC / 1 A -30°C up to +55°C -35°C up to +60°C IP 50 grey ABS 670 g 117 mm x 210 mm x 120 mm VdS G 203070 71 www.detectomat.com 6. special detectors 6.4 sensor cable detectors art. 30503 sensor cable detector SKM-03.01 • • • • • • connectable on the loop3000 via IOM3311 display unit to connect up to 300 m sensor cable appropriate to use in adverse surroundings or restricted circumstances (underground car parks, cable channels, etc.) potential-free alarm -and fault output delivery including cable installation box alarm display meets DIN 14623 technical specification sensor cable detector for the earliest detection of fire oder overheat in critical envoirements art. 30980 sensor cable red to connect to sensor cable detector SKM 03 • • appropriate in normal surrounding conditions without aggressive atmosphere tensile strength: < 200 N art. 30981 sensor cable black to connect to sensor cable detector SKM 04 • • appropriate in surrounding conditions with aggressive atmosphere tensile strength: < 200 N operation voltage quiesent current alarm current relay output operation temperature protection class housing color material weight dimensions (H x W x D) approvals SKM-KRT • • • design: synthetic-coaxial wire, diameter Ø 3,25 mm, color red approvals fanstening clamp VdS G 203067, VdS G 203 077 SKM-KSW • • • • design: synthetic-coaxial wire, diameter Ø 4 mm, color black protected against acids and bases approvals art. 31620 24 V DC 28 mA 58 mA 2 x 30 V DC / 1 A -25°C up to +50°C IP 65 grey ABS 370 g 105 mm x 105 mm x 65 mm VdS G 203067 VdS G 203067, VdS G 203 077 SK-LS for sensor cable detector • • • • to connect the sensor cable time-saving and simple start-up mounting hole diameter Ø 6mm selling-packages at 100 pieces 72 www.detectomat.com 6. special detectors 6.5 flame detectors art. 31897 ultraviolet flame detector FL 80/1A ultraviolet flame detector for an earliest fire detection in the industrial areas and in difficult envoirements • • • • • for the detection of open fire without smoke development integrated test-unit to check the detector function during operation sikh angle 90°-100° sensibility meets EN 54-10 class 1 high speed capability technical specification input voltage operation voltage quiesent current alarm current relay output operation temperature protection class housing color material weight dimensions (H x W x D) approvals intriscally safe class art. 31896 ultraviolet flame detector 24 V DC ± 25 % 24 V DC 45 mA 70 mA 2 x 30 V / 1A -20°C up to +80°C IP 54 red aluminium 1400 g 155 mm x 120 mm x 110 mm VdS G 28425 Germanischer Loyd FL 800/24V-K-N ultraviolet flame detector for an earliest fire detection in the industrial areas and in difficult envoirements • • • • for the detection of open fire without smoke development sikh angle variable 30°, 60° and 90° sensibility meets EN 54-10 class 1 high speed capability technical specification input voltage operation voltage quiesent current alarm current relay output operation temperature housing color protection class material weight dimensions (H x W x D) 19,2 up to 28,8 V 24 V DC 26 mA 46 mA 2 x 30 V / 1A -25°C up to +70°C grey IP 54 PC-LEXAN 800 g 200 mm x 150 mm x 150 mm 73 www.detectomat.com 6. special detectors 6.5 flame detectors art. 32075 infrared flame detector X 9800 technical specification operation voltage quiesent current alarm current interfaces relay output sensitivity infrared flame detector to ensure the detection of hydrocarbon fires in industrial applications such as turbines, petrochemie, automotive industry, projects with high contamination operation temperature stock temperature humidity • • • protection class housing color material weight dimensions (H x W x D) approvals intriscally safe class • • • • • • • • automatic, optical self-testing microprocessor controlled heated optics reliable detection even in case of more than one fault at the same time detects a n-heptane fire of 0,1m2 size until a distance of 15 metres high speed capability - 40 milliseconds sikh angle 90° tricolour LED indicates normal operation, fire and fault conditions mounting plate vibration-free after MIL event monitoring over built-in data logging maintenance mode over magnet modular housing design art. 30477 ultraviolet flame detector 18 up to 30 V DC 87,5 µA 550 mA RS485, 4-20mA 2x alarm, 1x fault N-Heptan: 0,1 mÇ in 15 m distance: less than 15 sec Methan: 30 inch flame in 10,5 m distance: less than 10 sec -40°C up to +75°C -55°C up to +85°C 0 up to 95 % - shortly 100 % humidity in air IP 66 red Aluminium 2700 g 119 mm x 122 mm x 246 mm VdS G 203084 0538 Ex II 2 GD, ATEX 132195, FM3260 remarks: a shielded cable with a conductor cross section of 0,5mm2 to 2,5mm2 is recommended X 2200 technical specification operation voltage quiesent current alarm current interfaces relay output sensitivity ultraviolet flame detector to ensure the detection of non-hydrocarbon fires in industrial applications such as turbines, hydrogen, ammunition, silane operation temperature stock temperature humidity • • protection class housing color material weight dimensions (H x W x D) approvals intriscally safe class • • • • • • • • automatic, optical self-testing reliable detection even in case of more than one fault at the same time detects a n-heptane fire of 0,1m2 size until a distance of 18 metres high speed capability sikh angle 90° tricolour LED indicates normal operation, fire and fault conditions mounting plate vibration-free after MIL event monitoring over built-in data logging maintenance mode over magnet modular housing design 18 up to 30 V DC 104 µA 253 mA RS485, 4-20mA 2x alarm, 1x fault N-Heptan: 0,1 mÇ in 18 m distance: 1 sec Methan: 30 inch flame in 21 m distance: 1 sec -40°C up to +75°C -55°C up to +85°C 0 up to 95 % - shortly 100 % humidity in air IP 66 red aluminium 2700 g 119 mm x 122 mm x 246 mm VdS G 203083 0538 Ex II 2 GD, ATEX 132195, FM3260 remarks: a shielded cable with a conductor cross section of 0,5mm2 to 2,5mm2 is recommended 74 www.detectomat.com 6. special detectors 6.5 flame detectors art. 32077 ultraviolet/infrared flame detector Eye 20/20 L • • • • • • environment-specific programming high speed capability sikh angle 90° horizontal and vertically manual and automatic inserting test mode high false alarm security modular housing design technical specification operation voltage quiesent current alarm current interfaces relay output sensitivity ultraviolet/infrared flame detector with combined analysis on UV and IR basis for the safe and failure-free detection of fires • • ultraviolet-infraret dual sensor reliable detection even in case of more than one fault at the same time 18 up to 32 V DC 100 mA 150 mA 4-20mA 2x alarm, 1x fault N-Heptan 15m, Methan 5m, Benzin 15m, Diesel 11m, Kerosin 11m, 5 sec. -40°C up to +70°C -55°C up to +85°C up to 95 % IP 66 grey aluminium 3700 g 132 mm x 132 mm x 120 mm pending ATEX EX II 2G, EExd IIB, FM, CSA, ATEX, Gost R und GostK operation temperature stock temperature humidity protection class housing color material weight dimensions (H x W x D) approvals intriscally safe class 6.6 intrisically safe detectors art. 31163 ex-ionisation smoke detector IRM Ex S60 • • radiation 33,3 kBq wind speed 10 m per second technical specification conventional ionisation smoke detector in ex-proof design • • two-chamber principle Am 241 as radioactive source operation voltage quiesent current operation temperature humidity housing color material dimensions (H x Ø) Ex approvals intriscally safe class 17 up to 28 V DC 30 µA by 20 V DC -10°C up to +60°C 0 - 95 % white ABS 42 mm x 100 mm BAS02, ATEX1288 VdS G 298 044 BAS02, ATEX1288 75 www.detectomat.com 6. special detectors 6.6 intrisically safe detectors art. 31164 ex-heat detector WM Ex S60 • • two temperature sensors maximal und differentiated triggering technical specification conventional thermal detector in ex-proof design, class 1 art. 31169 base for ex-detector operation voltage quiesent current operation temperature humidity housing color material dimensions (H x Ø) approvals intriscally safe class 17 up to 28 V DC 30 µA by 20 V DC -10°C up to +60°C 0 - 95 % white ABS 42 mm x 100 mm VdS G 298 047 BAS02, ATEX1288 Meldersockel Ex detector base in ex-proof design technical specification operation temperature housing colour material dimensions (H x Ø) intriscally safe class art. 31174 ex-barrier -10°C up to +60°C white ABS 20 mm x 95 mm BAS02, ATEX1288 Ex-B1 designed for ex-detectors in one ex detector zone • • including reverse battery protection for top hat rail mounting technical specification quiesent current operation temperature housing color material dimensions (H x W x D) 76 www.detectomat.com 6 mA -10°C up to +60°C green ABS 93 mm x 20 mm x 110 mm 6. special detectors 6.6 intrisically safe detectors art. 31170 ex manual call point HFM S65 , Ex • • for ex-areas until zone 0 for using without ex-barrier technical specification operation voltage alarm current operation temperature protection class housing color material dimensions (H x W x D) approvals intriscally safe class 19 up to 28 V DC 20 µA -20°C up to +80°C IP 66 red ABS 145 mm x 135 mm x 70 mm VdS G 295026 BAS02, ATEX1288 conventional ex-proof manual call point art. 30217 ex multiple tone sounder DB 5 conventional ex-proofen sounder • • • included DIN tone meets DIN 33404 26 different tones adjustable usable with ex barrier only technical specification operation voltage alarm current sounder output operation temperature protection class housing color dimensions (H x Ø) intriscally safe class art. 30219 ex-barrier SB SE/24 Ex designed for ex-sounder DB 5 technical specification • operation temperature housing colour material quiesent current dimensions (H x W x D) • • electrically particularly designed for ex multiple tone sounder DB5 DIN top hat rail mounting in housing Ex-H each sounder needs one barrier 24 V DC 12 mA 100 dB -10°C up to +60°C IP 65 red 102 mm x 90 mm BASEEFA-No. 92C2014 Klasse: Eex ia II C -10°C up to +60°C green ABS 6 mA 93 mm x 20 mm x 110 mm 77 www.detectomat.com 6. special detectors 6.6 intrisically safe detectors art. 31222 ex-beacon, red BE 24 R EEx conventional ex-proofen beacon, red technical specification • • • • • operation voltage alarm current operation temperature protection class housing color material dimensions (H x Ø) intriscally safe class beacon Ex, 24 V DC, red with yellow aluminium housing and red cover all purposes beacon with high light performance stainless steel to protect the cover flash energy: 15 Joule art. 31223 ex-beacon, yellow BE 24 Y EEx conventional ex-proofen beacon, yellow technical specification • • • • • operation voltage alarm current operation temperature protection class housing color material dimensions (H x Ø) intriscally safe class beacon Ex, 24 V DC, yellow with yellow aluminium housing and yellow cover all purposes beacon with high light performance stainless steel to protect the cover flash energy: 15 Joule art. 30218 housing for ex-modules 24 V DC 1,0 A -20°C up to +40°C IP 67 red aluminium 243 mm x 110 mm II 2G EEx de IIC T6 24 V DC 1,0 A -20°C up to +40°C IP 67 yellow aluminium 243 mm x 110 mm II 2G EEx de IIC T6 M-1 to integrate ex-barriers, overload protection components and modules for top had rail mounting • • • • to integrate ex-barriers and protocol-interfaces on-wall mounting including 35 mm norm rail, which meets DIN EN 50022 up to 5 barriers can be included technical specification protection class housing color material dimensions (H x W x D) 78 www.detectomat.com IP 65 grey ABS 220 mm x 125 mm x 162 mm 7. home smoke detectors art. 30458 optical home detector HDv 3000 O • • • • • • • automatic fault monitoring of the measuring chamber as well as the battery voltage the acoustic alert is made by an integrated piezo alarm-sounder (> 85 dB) a visual and audiable low battery condition is signalled for 30 days up to 40 detectors can be interlinked for reporting fault and alarm conditions the optional plug-in radio module interface offers radio interlinking for reporting fault and alarm conditions via (433 MHz and/or. 868 MHz) the average life span with a 9 V alkaline battery is approximatly 2 years (without interlinking or alarms at 20°C ambient temperature) the pack includes the detector base, battery, screws and anchors technical specification battery powerd optical home detector for detection and alarming in domestic applications • • optical smoke detector for the early detection of smoke private living areas integreated pre alarm levels for an early smoke verification art. 30023 optical home detector operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals complies with 9V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s white ABS 160 g 51 mm x 100 mm VdS G 202042 DIN 14604 remarks: for the usage of radio modules a lithium ion battery is recommended HD 3001 O white technical specification battery powerd optical home detector for detection and alarming in domestic applications • features as HDv 3000 O operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals 9V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s white ABS 140 g 42 mm x 95 mm VdS G 202054 EN 14604 79 www.detectomat.com 7. home smoke detectors art. 30024 optical home detector HD 3001 O silver technical specification simlilar to HDv 3000 O, design 1, silver • features as HDv 3000 O art. 30123 optical home detector operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals 9 V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s silver ABS 140 g 42 mm x 95 mm VdS G 202054 EN 14604 HD 3001 O black technical specification simlilar to HDv 3000 O, design 1, black • features as HDv 3000 O art. 31837 optical home detector operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals 9 V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s black ABS 140 g 42 mm x 95 mm VdS G 202054 EN 14604 HD 3004 O white technical specification simlilar to HDv 3000 O, design 4, white • features as HDv 3000 O operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals 80 www.detectomat.com 9 V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s white ABS 140 g 56 mm x 110 mm VdS G 202090 EN 14604 7. home smoke detectors art. 31914 optical home detector HD 3004 O silver technical specification simlilar to HDv 3000 O, design 4, silver • features as HDv 3000 O art. 32015 optical home detector operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals 9 V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s silver ABS 160 g 56 mm x 110 mm VdS G 202090 DIN 14604 HD 3005 O white technical specification simlilar to HDv 3000 O, design 5, white • features as HDv 3000 O art. 32004 optical home detector operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals 9 V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s white ABS 160 g 56 mm x 110 mm VdS G 202091 DIN 14604 HD 3005 O silver technical specification simlilar to HDv 3000 O, design 5, silver • features as HDv 3000 O operation voltage quiesent current alarm current interfaces sensitivity operation temperature humidity air speed housing colour material weight dimensions (H x Ø) approvals 9 V DC < 16 µA 5 mA radio link and wire link interface < 0,15 dB / m -10°C up to +60°C 95 % RH / 40°C max. 20 m / s silver ABS 160 g 56 mm x 110 mm VdS G 202091 EN 14604 81 www.detectomat.com 7. home smoke detectors art. 30933 radio link module FM 868 • • with the module the detectors can be cascade interlinked without a panel automatic amplifying of the radio signal via the integrated repeater function technical specification bidirectional radio module to interlink home detectors in cascaded networks in the transmitting frequency of 868MHz • • working area in frequency band 868 MHz bidirectional controlling function in case of alarm, signalising of all connected detectors art. 31674 wireless fire control panel alarm current interfaces operation temperature humidity weight 37 mA radio link interface to the home detector -10°C bis +60°C 95 % RH / 40°C 100 g RCP 6 • • • • 4 potential-free outputs, freely programmable a separate 230 V plug power-pack is included in the delivery emergency batteries 8 x 1,5 V are included LCD display technical specification microprcessor controlled radio panel to control home detetectors by wireless network over 433 MHz • • • working area in frequency band 433 MHz 6 zones connection up to 100 home smoke detectors via the module 433 MHz art. 30947 radio link module input voltage frequency operation voltage emergency power quiesent current alarm current display zone LED´s relay output operation temperature stock temperature humidity protection class housing colour / front colour material weight dimensions (H x W x D) 230 V AC 50 / 60 Hz 12 V AC 8 x 1,5 V batteries 30 mA 50 mA LCD 6 zones 4 x change over contact 0°C up to +60°C -10°C up to +60°C max. 70 % IP 20 grey / silver ABS 1000 g 170 mm x 170 mm x 55 mm FM 433 • with the module the home smoke detectors can be connected to the fire control panel RCP6 technical specification alarm current interfaces wireless module to connect home detectors to the wireless fire control panel RCP6 in the transmitting frequency of 433 MHz • working area in frequency band 433 MHz operation temperature humidity weight 82 www.detectomat.com 37 mA radio link interface to the home detector -10°C up to +60°C 95 % RH / 40°C 100 g 8. signalling devices 8.1 signalling devices for loop3000 art. 31836 loop sounder, red LS 3300 R • • • 2 different tones adjustable (including DIN tone) automatic addressing (soft-addressing) manual addressing (EasyCheck) technical specification low current multiple tone sounder directly powered by the loop3000, red • • • direct addressable via the loop3000 integrated bidirectional short circuit isolator addressable spur connection via T-branch art. 32012 loop sounder, white operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) 15 up to 30 V loop powered 5 mA max. 97 dB -10°C up to +60°C IP 43 red ABS 340 g 100 mm x 101 mm LS 3300 W • • • 2 different tones adjustable (including DIN tone) automatic addressing (soft-addressing) manual addressing (EasyCheck) technical specification low current multiple tone sounder directly powered by the loop3000, white • • • direct addressable via the loop3000 integrated bidirectional short circuit isolator addressable spur connection via T-branch art. 32060 loopsounder kit operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) 15 up to 30 V loop powered 5 mA max. 97 dB -10°C up to +60°C IP 43 white ABS 340 g 100 mm x 101 mm LS 3300 VLC • shallow base for lateral and rear cable entry technical specification low current multiple tone sounder directly powered by the loop3000 via control modul, white • • • • direct addressable via the loop3000 multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) complies with 440 up to 2900 Hz 15 up to 30 V loop powered 5 mA max. 97 dB -10°C up to +60°C IP 43 white ABS 250 g 27 mm x 117 mm EN 54 83 www.detectomat.com 8. signalling devices 8.1 signalling devices for loop3000 art. 32067 cover for sounder, color red AD R art. 32068 cover for sounder, color white AD W art. 32061 loopsounder base kit LS 3300 SBK low current multiple tone sounder directly powered by the loop3000 via control modul, integreated base for addressable detectors of the series loop3000, white • • • • • • direct addressable via the loop3000 including detector base for all detectors of the series loop3000 multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable shallow base for lateral and rear cable entry art. 30204 sound unit • detector not included technical specification frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) complies with 440 up to 2900 Hz 15 up to 30 V loop powered 5 mA max. 97 dB -10°C up to +60°C IP 43 white ABS 250 g 45 mm x 117 mm EN 54 SDM 3300 R • shallow base for lateral and rear cable entry technical specification sounder to use in the loop3000, low powered multiple-tone sounder with sound-module, according to DIN 33404 addressable connection with external voltage • • • • • • direct connection to the loop3000 integrated automatic addressing-unit integrated bidirectional short circuit isolator addressable spur connection via T-branch external voltage supply 24 V necessary internal sound levels adjustable art. 32058 loop beacon, red frequency operation voltage quiesent current alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) complies with 500 up to2850 Hz 15 up to 30 V 250 µA 9 up to 29 mA 111 dB -10°C up to +60°C IP 54 red ABS 340 g 93 mm x 93 mm EN 54 LB-3300-VXB-R technical specification low current beacon unit directly powered by the loop3000 via control modul • • • low current beacon white housing with red light cover brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt frequency operation voltage alarm current operation temperature protection class housing colour material weight dimensions (H x Ø) complies with 84 www.detectomat.com 1 Hz 15 up to 30 V loop powered 5 mA -10°C up to +60°C IP 43 white ABS 145 g 60 mm x 95 mm EN 54 8. signalling devices 8.1 signalling devices for loop3000 art. 32090 loop beacon, orange LB 3300 VXB O technical specification low current beacon unit directly powered by the loop3000 via control modul • • • low current beacon white housing with orange light cover brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt frequency operation voltage alarm current operation temperature protection class housing colour material weight dimensions (H x Ø) complies with 1 Hz 15 up to 30 V loop powered 5 mA -10°C up to +60°C IP 43 white ABS 145 g 60 mm x 95 mm EN 54 8.2 conventional signalling devices art. 32051 multiple tone sounder, red VTG-32-SB R • shallow base for lateral and rear cable entry technical specification low powered multiple-tone sounder, colour: red, modern technology with 32 different tones • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable art. 32053 multiple tone sounder, white frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) approvals complies with 440 up to 2900 Hz 15 up to 35 V DC 9 up to 36 mA max. 111 dB -20°C up to +70°C IP 43 red ABS 220 g 85 mm x 94 mm VdS G 205137 EN 54 VTG-32-SB W • shallow base for lateral and rear cable entry technical specification low powered multiple-tone sounder, colour: white, modern technology with 32 different tones • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) approvals complies with 440 up to 2900 Hz 15 up to 35 V DC 9 up to 36 mA max. 111 dB -20°C up to +70°C IP 43 white ABS 220 g 85 mm x 94 mm VdS G 205137 EN 54 85 www.detectomat.com 8. signalling devices 8.2 conventional signalling devices art. 32052 multiple tone sounder, red, IP 65 VTG-32-DB R • shallow base for lateral and rear cable entry technical specification low powered multiple-tone sounder colour: red, modern technology with 32 different tones, class of protection: IP 65 • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable art. 32054 multiple tone sounder, white, IP 65 frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) approvals complies with 440 up to 2900 Hz 15 up to 35 V DC 9 up to 36 mA max. 111 dB -20°C up to +70°C IP 65 red ABS 250 g 102 mm x 94 mm VdS G 205137 EN 54 VTG-32-DB W • shallow base for lateral and rear cable entry technical specification low powered multiple-tone sounder colour: white, modern technology with 32 different tones, class of protection: IP 65 • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable art. 32055 base sounder frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) approvals complies with 440 up to 2900 Hz 15 up to 35 V DC 9 up to 36 mA max. 111 dB -20°C up to +70°C IP 65 white ABS 250 g 102 mm x 94 mm VdS G 205137 EN 54 Verso 32 Tone • shallow base for lateral and rear cable entry technical specification low powered multiple-tone sounder, colour: white, modern technology with 32 different tone • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) complies with 86 www.detectomat.com 440 up to 2900 Hz 15 up to 35 V DC 9 up to 36 mA max. 111 dB -20°C up to +70°C IP 43 white ABS 250 g 27 mm x 117 mm EN 54 8. signalling devices 8.2 conventional signalling devices art. 32067 cover for sounder, color red AD R art. 32068 cover for sounder, color white AD W art. 30216 symphony tone sounder SYS 120 R technical specification multiple-tone sounder, colour: red, modern technology with 32 different tones • • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 500 Hz up to 2850 Hz are synchronizable 3 sound levels adjustable strong sound with up to 120 dB art. 31664 voice sounder frequency operation voltage alarm current noise operation temperature protection class housing colour weight dimensions (H x W x D) approvals complies with 500 up to 2850 Hz 9 up to 28 V DC 230 up to 290 mA max. 120 dB -25°C up to +55°C IP 43 red 340 g 106 mm x 106 mm x 95 mm VdS G 206026 EN 54 CLA R technical specification sounder with voice-announcement, high voice quality, standard announcement stored • • • • • • • • sounder with voice announcement multifunction alarm sounder adjustable volume base is compatible to sounders and beacons high quality of the sound rendition standard announcements are stored in the database automatic synchronization low current consumption art. 31665 voice sounde input voltage operation voltage alarm current noise operation temperature protection class housing colour weight dimensions (H x Ø) complies with 18 up to 30 V DC 18 up to 30 V DC 20 mA 102 dB -10°C up to +55°C IP 65 red 265 g 83 mm x 95 mm EN 54 CLA W technical specification sounder with voice-announcement, high voice quality, standard announcement stored • • • • • • • • sounder with voice announcement multifunction alarm sounder adjustable volume base is compatible to sounders and beacons high quality of the sound rendition standard announcements are stored in the database automatic synchronization low current consumption input voltage operation voltage alarm current noise operation temperature protection class housing colour weight dimensions (H x Ø) approvals complies with 18 up to 30 V DC 18 up to 30 V DC 20 mA 102 dB -10°C up to +55°C IP 65 white 265 g 83 mm x 95 mm pending EN 54 87 www.detectomat.com 8. signalling devices 8.2 conventional signalling devices art. 31193 LED indicator PA • • • alarm indicator for flush mounted detectors connection to the detector base on-wall mounting technical specification LED indicator for alarm display of the automatic detectors series loop3000 and CT art. 31195 LED indicator alarm current housing colour material dimensions (H x W x D) 4 mA white ABS 84 mm x 84 mm x 35 mm PA2-VdS • • connection to the detector base on-wall mounting technical specification LED indicator for alarm display of the automatic detectors series loop3000 and CT • alarm indicator for flush mounted detectors art. 30178 LED indicator, flush-mounting alarm current housing colour material dimensions (H x W x D) approvals 2,5 mA white ABS 86 mm x 86 mm x 45 mm VdS G 294052 PA-uP • • • alarm indicator for flush mounted detectors connection to the detector base flush mounting, installation hole 22 mm diameter technical specification LED indicator for alarm display of the automatic detectors series loop3000 and CT art. 40100 beacon, red alarm current housing colour material dimensions (H x Ø) 3 mA white ABS 52 mm x 26 mm BE 24 technical specification conventional beacon unit, red • • • available in the colours red, orange, green and blue brightness 2 joule at 24 V and 1 joule at 12 V IP rating 65 will be achieved with base 40059 red or 40060 white frequency operation voltage alarm current operation temperature protection class material dimensions (H x Ø) approvals 1 Hz 12 / 24 V DC 155 mA -10°C up to +60°C IP 54, with additional base IP 65 ABS 72 mm x 93 mm VdS G 296014 remarks: when ordering please indicate the color and the operation voltage of the calotte 88 www.detectomat.com 8. signalling devices 8.2 conventional signalling devices art. 30228 round beacon RBE 24 technical specification conventional round beacon unit, red frequency operation voltage alarm current operation temperature protection class housing colour material dimensions (H x Ø) • • remarks: when ordering please indicate the color of the calotte available in the colours red and orange brightness 5 joule at 24 V art. 32056 beacon, red 1 Hz 24 V DC 200 mA -10°C up to +60°C IP 54 white ABS 135 mm x 108 mm VXB-1-SB-WB-RL • brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt technical specification low current beacon unit, red housing, red light frequency operation voltage alarm current operation temperature protection class housing colour material weight dimensions (H x Ø) • • remarks: when ordering please indicate the color of the calotte low current beacon available in the colours red and orange art. 32057 beacon IP 65 1 Hz 20 up to 35 V 3 up to 5 mA -20°C up to +70°C IP 43 white ABS 145 g 60 mm x 95 mm VXB-1-DB-WB-RL • brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt technical specification low current beacon unit, white housing, red light, IP 65 frequency operation voltage alarm current operation temperature protection class housing colour material weight dimensions (H x Ø) • • remarks: when ordering please indicate the color of the calotte low current beacon available in the colours red and orange 1 Hz 20 up to 35 V 3 up to 5 mA -20°C up to +70°C IP 65 white ABS 165 g 80 mm x 95 mm 89 www.detectomat.com 8. signalling devices 8.2 conventional signalling devices art. 32062 sounder beacon combination, white VTB-32-SB W low powered multiple-tone sounder with 32 different tones, colour: white, combined with beacon red • • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt technical specification frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) art. 32063 sounder beacon combination, white, IP 65 440 up to 2900 Hz 15 up to 35 V DC 14 up to 41 mA max. 109 dB -20°C up to +70°C IP 43 white ABS 233 g 90 mm x 94 mm VTB-32-DB W low powered multiple-tone sounder with 32 different tones, colour: white, combined with beacon red, IP 65 • • • • multiple tone sounder with 32 different tones (including DIN tone) adjustable via DIP button tones in the frequency-band of 440 Hz up to 2900 Hz are synchronizable 3 sound levels adjustable brightness at 5 mA 0,7 watt and at 3 mA 0,4 watt technical specification frequency operation voltage alarm current noise operation temperature protection class housing colour material weight dimensions (H x Ø) 90 www.detectomat.com 440 up to 2900 Hz 15 up to 35 V DC 14 up to 41 mA max. 109 dB -20°C up to +70°C IP 65 white ABS 258 g 107 mm x 94 mm 9. door magnets and accessoires art. 30411 power supply 450 mA SV 04 • LED indicator for operation display technical specification power supply 450 mA for door magnets • integreated short circuit protection art. 30412 power supply 800 mA input voltage frequency operation voltage external user output operation temperature protection class housing colour material dimensions (H x W x D) approvals 230 V AC 50 Hz +/- 10 % 24 V DC 400mA -10 up to +40°C IP 20 silver sheet steel 115 mm x 80 mm x 50 mm DIBT Z6.5-1335, VdS approved SV 08 • LED indicator for operation display technical specification power supply 800 mA for door magnets • integreated short circuit protection art. 30410 door control panel input voltage frequency operation voltage external user output operation temperature protection class housing colour material dimensions (H x W x D) approvals 230 V AC 50 Hz +/- 10 % 24 V DC max 800mA -10 up to +40°C IP 20 white sheet steel 160 mm x 105 mm x 55 mm DIBT Z6.5-1335, VdS approved TSZ 0400 • • • • • • up to 3 panels linkable integreated short circuit protection LED indicators for operation, alarm and fault display up to 10 detectors connectable up to 12 door magnets connectable usable in ex-areas with accessoires technical specification microprcessor controlled panel to control fire doors, door magnets and detectors • • • • integreated power supply for detectors and door magnets alarm evaluation and controlling functions integreated reset function additional external output for connection of signalling devices input voltage frequency operation voltage relay output external user output operation temperature protection class housing colour material dimensions (H x W x D) approvals 230 V AC 50 Hz +/- 10 % 24 V DC 2 change over 30V / 1A max 800mA 0 up to +40°C IP 42 greywhite, RAL 9002 ABS 185 mm x 233 mm x 93 mm DIBT Z6.5 - 1646, VdS approved 91 www.detectomat.com 9. door magnets and accessoires art. 31236 optical detector with relay base RM3000 conventional optical smoke detector, complies with EN 54 part 7 specification and relay base for connection on door control panels • • • integreated relay base 3 times alarm evaluation for controlling function LED indicator for operation, alarm and fault display technical specification operation voltage quiesent current alarm current relay output operation temperature protection class housing colour material dimensions (H x Ø) approvals art. 30417 manual activation button 18 up to 28 V DC 24 mA 62 mA 1 change over 50V / 1A -20°C up to +60°C IP 43 white ABS 50 mm x 100 mm DIBT Z6.5-1335, VdS G 200 107 HT aP for door control units with on-wall mounting technical specification operation temperature housing colour material dimensions (H x W x D) art. 30418 manual activation button -20°C up to +60°C red ABS 63 mm x 63 mm x 37 mm HT uP for door control units with flush-mounting technical specification operation temperature housing colour material dimensions (H x W x D) 92 www.detectomat.com -20°C up to +60°C red ABS 80 mm x 80 mm x 33 mm 9. door magnets and accessoires art. 30428 door magnet EM GD 60 F 26 • • • • • input protection via diode polarisation protected peel adhesion 700N power on time 100% magnet diameter 60 mm technical specification door magnet for wall mounting, for door holding • integrated activation button art. 30422 door magnet operation voltage alarm current operation temperature protection class colour material dimensions (H x W x D) approvals 24 V DC ± 10 % 67 mA -20°C up to +60°C IP 40 grey steel 30 mm x 55 mm x 93 mm DIBT Z6.5 1335, VdS approved EM GD 60 K 70 • • • • • input protection via diode polarisation protected peel adhesion 700N power on time 100% magnet diameter 60 mm technical specification door magnet for wall mounting with plastic-bottom, for door holding • integrated activation button art. 30423 door magnet operation voltage alarm current operation temperature protection class colour material dimensions (H x Ø) approvals 24 V DC ± 10 % 67 mA -20°C up to +60°C IP 40 grey steel/ABS 70 mm x 82 mm DIBT Z.6.5-1335, VdS approved EM GD 60 S 175 • • • • • • input protection via diode polarisation protected peel adhesion 700N power on time 100% magnet diameter 60mm length 175mm, 90° deviated 137 mm technical specification panning-head magnet with turnable head to mount at walls, ceilings or floors • integrated activation button operation voltage alarm current operation temperature protection class colour material dimensions (H x Ø) approvals 24 V DC ± 10 % 67 mA -20°C up to +60°C IP 40 grey steel 175 mm x 96 mm DIBT Z.6.5-1335, VdS approved 93 www.detectomat.com 9. door magnets and accessoires art. 30424 door magnet EM GD 60 S 325 • • • • peel adhesion 700N power on time 100% magnet diameter 60 mm length 325mm, 90° deviated 287 mm technical specification panning-head magnet with turnable head to mount at walls, ceilings or floors • • • integrated activation button input protection via diode polarisation protected art. 30425 door magnet operation voltage alarm current operation temperature protection class colour material dimensions (H x Ø) approvals 24 V DC ± 10 % 67 mA -20 up to +60°C IP 40 light grey steel 325 mm x 96 mm DIBT Z.6.5-1335, VdS approved EM GD 60 S 475 • • • • peel adhesion 700N power on time 100% magnet diameter 60 mm length 475mm, 90° deviated 437 mm technical specification panning-head magnet with turnable head to mount at walls, ceilings or floors • • • integrated activation button input protection via diode polarisation protected art. 30434 door magnet operation voltage alarm current operation temperature protection class colour material dimensions (H x Ø) approvals 24 V DC ± 10 % 67 mA -20 up to +60°C IP 40 light grey steel 475 mm x 96 mm DIBT Z.6.5-1335, VdS approved EM GD 60 FB • • • • • integrated activation button input protection via diode polarisation protected peel adhesion 700N power on time 100% technical specification door magnet with a robust housing of aluminium for base-mounting operation voltage alarm current operation temperature protection class colour material dimensions (H x W x D) approvals 94 www.detectomat.com 24 V DC ± 10 % 67mA -20 up to +60°C IP 40 black aluminium 100 mm x 165 mm x 107 mm DIBT Z.6.5-1335, VdS approved 9. door magnets and accessoires art. 30436 door magnet EM GD 70 Ex technical specification ex-proof door magnet usable in ex areas with protection class zone 1 and 2 • • • • • • ex proof housing connectable via terminal blocks input protection via diode polarisation protected peel adhesion 1450N power on time 100% art. 30437 anchor plate operation voltage alarm current operation temperature protection class colour material dimensions (H x W x D) approvals complies with intriscally safe class 24 V DC 70mA -20°C up to +40°C IP 66 grey steel 110 mm x 75 mm x 43 mm DIBT Z-6.5-1335, Ex II 2G Eex m II T6, IP 66 Ex II 2G EExem II T6 Eex m/e IIT6 AP GD 60 G 16 • • • up to 10° movable zinc housing plate diameter 64 mm technical specification flexible anchor plate with rubber bearing usable for the connection between door magnet and fire door art. 30438 anchor plate colour material dimensions (H x W x D) zinc steel 65 mm x 65 mm x 16 mm AP GD 60 W 50 • • • up to 60° movable zinc housing plate diameter 64 mm technical specification colour material dimensions (H x W x D) black steel 65 mm x 65 mm x 51 mm flexible anchor plate with rubber bearing and angle joint usable for the connection between door magnet and fire door art. 30439 anchor plate AP GD 60 T 80 • • • • for heavy doors and gates robust black housing flexible anchor plate diameter 64 mm elasticity strength approximately 100 N at 20 mm lift technical specification telescope anchor plate with damper usable for the connection between door magnet and fire door colour material dimensions (H x Ø) black steel 85 mm x 80 mm 95 www.detectomat.com 10. detector testing devices art. 31956 smoke detector test & removal set SOLO 812 kit includes the following: • • • • • art. 14008 aerosol smoke dispenser 1 fibreglass telescopic extension pole 4,50 metres 1 fibreglass extension pole 1,13 metres 1 universal removal tool 1 aerosol smoke dispenser 1 protective carrying / storage bag SOLO 330 smoke dispenser for the release of smoke test aerosol for efficient activation of detectors • • • art. 30398 heat detector tester clear cup - allows view of detector LED spring loaded mechanism for effectiv, economic aerosol delivery touch sensitiv - ideal for suspended ceilings SOLO 461 wire free test set for heat detectors including: • • • art. 14007 detector removal tool cordless heat detector tester 2 battery batons 1 fast charger SOLO 200 detector removal tool for easy replacement of all detectors 96 www.detectomat.com 10. detector testing devices art. 14006 telescope pole SOLO 100 telescope pole, expandable in 4 sections • art. 30193 extension pole fibreglass extension pole 1,13 metres art. 14010 bag for test-set 4 section fibreglass telecope pole expandable from 1,20m up to 4,50m SOLO 101 • maximum applicable 2 pieces each telescope bar SOLO 610 carrying / storage bag for test equipment • • designed to fit all test equipment separate pole bag included technical specification dimensions (H x W x D) art. 40055 testaerosol 460 mm x 45 mm x 180 mm TA 300 for smoke detectors, 300 ml art. 31845 testaerosol SOLO A3 for smoke detectors, 250 ml 97 www.detectomat.com Article index art. Typ Description 14006 telescope pole SOLO 100 14007 14008 14010 30003 30007 30008 30009 30010 30011 30014 30015 30021 30022 30023 30024 30025 30026 30077 30078 30079 30087 30088 30092 30096 30097 30098 30099 30106 30111 30112 30113 30114 30115 30116 30118 30119 30120 30122 30123 30124 30128 30131 30136 30137 30138 30139 30143 30144 30145 30146 30151 30155 30156 30164 30167 30168 30169 30178 30187 30188 30189 30190 30191 30193 30200 30201 30204 30205 30209 30210 detector removal tool aerosol smoke dispenser bag for test-set wireless optical smoke detector optical smoke and heat detector heat detector optical smoke detector heat detector, isolator optical smoke detector, isolator heat detector optical smoke detector optical smoke and heat detector, isolator multisensor detector optical home detector optical home detector WGW 3300 WGW 3300 Relay board 8 change over aspiration smoke detector CO gas and heat detector, isolator bitbus interface LED indicator modul optical smoke detector, isolator conventional interface redundant 8 fire zones extension module LED indicator modul mount in printer including paper storage mount in printer Extinguishing control modul Redundant main board processor Redundant main board processor extinguishing interface OC control module connection board monitored module for 8 outputs bitbus CPU extension for BitBus CPU, 32 open collector outputs extension for BitBus CPU, 16 relay outputs optical home detector BitBus amplifier BitBus LED indicator extension power supply 192 W detectomat programming tool software-expansion-dongle modem Bitbus programming tool Visual detect basis software Visual detect user expansion Visual detect expansion panel Visual detect operation expansion battery 12 V / 45 Ah battery 12 V / 12 Ah battery 12 V / 18 Ah mounting plate 19" front panel 64 19" front panel 128 19" front panel 192 LED indicator, flush-mounting detector mounting adapter detector flap-mounting adapter detector distance-mounting adapter wall bracket wall bracket extension pole in-/output module 2-loop interface redundant sound unit conventional zone module 2-loop interface conventional interface for 8 fire zones SOLO 200 SOLO 330 SOLO 610 WL 3200 O PL 3200 OT PL 3200 T PL 3200 O PL 3300 T PL 3300 O CT 3000 T CT 3000 O PL 3300 OT CT 3000 OT HD 3001 O white HD 3001 O silver wireless gateway HFM EG-Gx RL 58 ASD-20 PL 3300 CDBT CP BBI CP ZM 8 PL 3300 O/K CP CLI X2-R CP ECB CP ZM 32 PIP 1 PIP 2 CP ETB X1 CP CPU X2-R CP CPU X1-R CP SIE CP AM 32 CP AM AP SC 8 BB-CPU BB-32 BB-16 HD 3001 O black BB-R BB-LED NT 8 DPT 3000 D 3000 RM MO BPT VD Basic 11 VD UE 1 VD PE 1 VD CE 1 B 12/ 45Ah B 12/ 12Ah B 12/ 18Ah MP 19" FP-1 19" FP-2 19" FP-3 PA-uP MKBD MKK MAK WA4 WA2 SOLO 101 IOM 3311 DLI 3240 X2-R SDM 3300 R TCM 3300 DLI 3240 X1-2L CP CLI X1 98 www.detectomat.com page 97 96 96 97 59 38 37 33 37 33 42 39 38 42 79 80 59 55 18 65 39 26 9, 10 36 15 15 15, 16 10, 16, 20 4, 10, 12, 16, 20 10 17 11 19 19 19 18 26 26 26, 27 80 27 27 21 29 29 23 26, 29 31 32 32 32 22 21 22 16 16 16 16 88 47 47 48 48 48 97 56 14 84 58 7 9 Article index art. Typ Description 30211 30216 30217 30218 30219 30228 30301 30321 30335 30336 30337 30386 30398 30410 30411 30412 30417 30418 30422 30423 30424 30425 30428 30434 30436 30437 30438 30439 30458 30461 30469 30471 30473 30474 30477 30479 30488 30501 30503 30513 30523 30525 30545 30546 30551 30552 30555 30556 30567 30568 30569 30926 30927 30933 30941 30947 30956 30977 30980 30981 31024 31059 31060 31061 31062 31069 31083 31087 31088 31091 31092 output module SYS 120 R ex multiple tone sounder housing for ex-modules ex-barrier round beacon detector base base for overvoltage protection modules Loop protection module Conventional protection module Bitbus protection module Adapter for LED indicator modul heat detector tester door control panel power supply 450 mA power supply 800 mA manual activation button manual activation button door magnet door magnet door magnet door magnet door magnet door magnet door magnet anchor plate anchor plate anchor plate optical home detector battery 12 V / 65 Ah detector relay base power supply 120 W infrared beam detector infrared beam detector ultraviolet flame detector labelling tag for detector base optical smoke detector, isolator, silver I-Check 3000 software sensor cable detector mini in-/output module detector base, black optical smoke detector, isolator, black optical smoke detector, white optical smoke detector, silver optical smoke detector, white optical smoke detector, silver optical smoke detector, isolator, white optical smoke detector, isolator, silver optical smoke detector, isolator, white optical smoke detector, isolator, silver manual call point, chinese detector base, silver ground circuit module radio link module conventional fire control panel radio link module optical smoke detector, isolator, white optical smoke detector sensor cable red sensor cable black BitBus computer interface ISA-Slot manual call point, ABS manual call point, ABS manual call point, ALU manual call point, ALU glass for manual call point manual call point, IP 66 manual call point, ALU, blue manual call point, ALU, yellow weatherproof housing weatherproof housing OMS 3301 symphony tone sounder DB 5 M-1 SB SE/24 Ex RBE 24 SDB 3000 CT B CT ME 48 CT ME / C 24 CT ME 5 CP ADB 48 SOLO 461 TSZ0400 SV 04 SV 08 HT aP HT uP EM GD 60 K 70 EM GD 60 S 175 EM GD 60 S 325 EM GD 60 S 475 EM GD 60 F 26 EM GD 60 FB EM GD 70 Ex AP GD 60 G 16 AP GD 60 W 50 AP GD 60 T 80 HDv 3000 O B 12/ 65Ah DRB 3000 NT 5 SPB-E IR BD SRA-ET IR BD-R X 2200 MBC PL 3301 O silver I-Check 3000 SKM-03.01 AMD 3311 SDB 3000 black PL 3301 O black CT 3004 O white CT 3004 O silver CT 3005 O white CT 3005 O silver PL 3304 O white PL 3304 O silver PL 3305 O white PL 3305 O silver PL 3300 MCP-kit SDB 3000 silver CP EM FM 868 BMZ 6 FM 433 PL 3301 O white CT 3000 O/K SKM-KRT SKM-KSW BBI PC PL 3300 PBD-ABS-B PL 3300 PBD-ABS-Y PL 3300 PBD- ALU-B PL 3300 PBD-ALU-Y HFM EG-B CT 3000 PDB-IP66-R CT 3000 PBD-ALU-BD CT 3000 PBD-ALU-YD WG-R WG-B page 57 87 77 78 77 89 43 22 23 23 23 9, 10 96 91 91 91 92 92 93 93 94 94 93 94 95 95 95 95 79 22 44 21 70 71 74 47 34 29 72 57 43 34 42 41 41 41 34 35 35 35 53 43 9 82 32 82 34 40 72 72 28 49 50 51 51 55 54 53 54 55 55 99 www.detectomat.com Article index art. Typ Description 31095 31096 31114 31115 31117 31118 31133 31135 31136 31138 31140 31141 31143 31145 31146 31147 31148 31149 31151 31152 31153 31154 31155 31156 31163 31164 31169 31170 31174 31181 31191 31193 31195 31222 31223 31236 31312 31315 31318 31320 31476 31482 31486 31589 31596 31613 31620 31621 31622 31625 31626 31627 31640 31651 31654 31664 31665 31668 31669 31674 31675 31676 31684 31698 31817 31836 31837 31845 31861 31867 31875 infrared beam detector reset module Stratos HSSD-2 standard detector Stratos HSSD-2 standard detector and control module Stratos HSSD-2 control module Stratos Micra 25 including mounting base Stratos asirating pipe 3/4" Stratos 45° deg elbow pipe Stratos 90° bend Stratos socket Stratos T-piece Stratos socket union Stratos end cap Stratos pipe clip, red Stratos pipe clip black Stratos ABS solvent cement Stratos pipe cleaner Stratos sampling hole warning stickers Stratos nylon tube, red Stratos nylon tube, white Stratos in-line remote sampling point adapter Stratos end cap adaptor Stratos in-line smapling point Stratos patress sampling point ex-ionisation smoke detector ex-heat detector base for ex-detector ex manual call point ex-barrier base for humid areas housing for air ducts LED indicator LED indicator ex-beacon, red ex-beacon, yellow optical detector with relay base 2-loop interface redundant LCD repeater panel universal expansion housing universal expansion housing Stratos Micra 100 including mounting base EasyCheck infrared beam detector optical smoke detector, silver parallel indicator display Stratos plug sampling point assembly fanstening clamp BitBus - fibre optical interface fibre optical cable converter loop tester radio field analyzer wireless input module mini output module manual call point, ABS, blue Visual detect interface management system voice sounder voice sounder manual call point, ALU manual call point, ABS wireless fire control panel manual call point, ABS, red manual call point, ALU, red flush-mounting adapter silver wall mount base adapter 1-loop interface loop sounder, red optical home detector testaerosol infrared beam detector Stratos HSSD-2 standard detector without display base with heating FR 2000 RM95 HSSD-2 M HSSD-2 M-S HSSD-2 S Micra 25 STR-R STR-W45 STR-B90 STR-M STR-T STR-V STR-E STR-C STR-CA STR-SK STR-RE STR-WA STR-KR STR-KW STR-MK STR-EK STR-KK STR-KB IRM Ex S60 WM Ex S60 Meldersockel Ex HFM S65, Ex Ex-B1 FRS LKMG PA PA2-VdS BE 24 R EEx BE 24 Y EEx RM3000 DLI 3240 X1-R LCD-Tableau UZG-1 UZG-2 Micra 100 EC 3000 FR 100 RV CT 3001 O silver ZPA2002 STR-SK SK-LS LCON-1 LCON-2 LT 3000 RFA 3000 WL 3210 EM OMS 3301mini CT 3000 PBD-ABS-B VD M I CLA R CLA W PL 3300 PBD-ALU-R PL 3300 PBDH-ABS-R RCP 6 CT 3000 PBDH-ABS-R CT 3000 PBDH-ALU-R DR45 APS DLI 3240 X1-1L LS 3300 R HD 3004 O white SOLO A3 FR 50 RV HSSD-2 MOD APSB 100 www.detectomat.com page 70 70 62 63 63 64 65 66 66 66 66 66 66 69 69 69 69 69 68 69 68 68 68 68 75 76 76 77 76 45 45 88 88 78 78 92 8 25 11 17 64 7, 8, 14, 30 71 40 20 67 72 28 28 30 61 60 57 53 32 87 87 50 49 82 52 53 41, 46 45 7 83 80 97 71 62 46 Article index art. Typ Description page 31896 31897 31910 31911 31914 31926 31929 31946 31947 31948 31949 31950 31953 31956 31959 31960 31972 31973 31974 31975 31989 31990 31991 31992 32004 32005 32012 32015 32039 32040 32045 32049 32050 32051 32052 32053 32054 32055 32056 32057 32058 32060 32061 32062 32063 32066 32067 32068 32070 32073 32074 32075 32076 32077 32082 32083 32084 32085 32086 32090 32091 32098 32099 32118 32119 40001 40003 40054 40055 40056 40100 ultraviolet flame detector ultraviolet flame detector glass for manual call point demo software for visual detect optical home detector optical smoke detector, black optical smoke detector, white mounting plate mounting plate Stratos adapter 3/4" female to 25 mm male Stratos 25 mm female to 3/4" male adapter Stratos socket 3/4" to 25 mm female Stratos HSSD-2 control module 19" smoke detector test kit detector base, bridged Stratos flange nut fire control panel shallow fire control panel language kit German language kit English fire control panel fire control panel 19" rack mount language kit German language kit English optical home detector antenna for extended range loop sounder, white optical home detector language kit German for a master panel in the BitBus network language kit English for a master panel in the BitBus network optical smoke detector fire control panel 19" rack mount Stratos ABS-socket 3/4" to 25 mm multiple tone sounder, red multiple tone sounder, red, IP 65 multiple tone sounder, white multiple tone sounder, white, IP 65 base sounder beacon beacon IP 65 loop beacon, red loopsounder kit loopsounder base kit sounder beacon combination, white sounder beacon combination, white, IP 65 monitored module for 4 outputs cover for base sounder cover for base sounder flush-mounting adapter white extension module in-/output module mini infrared flame detector aspiration smoke detector ultraviolet/infrared flame detector manual call point, ABS, red detector base, bridged detector base, bridged detector relay base detector relay base loop beacon, orange piezo buzzer for detectors 2-loop interface active 2-loop interface active, redundant remote display- and control panel remote display- and control panel battery 12 V / 26 Ah Extinguishing control modu key for manual call point testaerosol battery 12 V / 7,2 Ah beacon FL 800/24V-K-N FL 80/1A HFM EG VD DV HD 3004 O silver CT 3001 O black CT 3001 O white CP MP 3004 CP MP 3016 STR-R3/4"-25 STR-R26-3/4" STR-RM5 HSSD-2 S 19" SOLO 812 SDBB 3000 STR-CM detect 3004 - shallow detect 3004 LK 3004 D LK 3004 GB detect 3016 detect 3016-19" LK 3016 D LK 3016 GB HD 3005 O silver WGA 3200 LS 3300 W HD 3005 O white LK ABF D LK ABF GB PL 3200 O/K detect 3004-19" STR-RH VTG-32-SB R VTG-32-DB R VTG-32-SB W VTG-32-DB W Verso 32 Tone VXB-1-SB-WB-RL VXB-1-DB-WB-RL LB-3300-VXB-R LS 3300 VLC LS 3300 SBK VTB-32-SB W VTB-32-DB W SC 4 AD R AD W DR45W UBW 3311 AOM 3301 X 9800 ASD-01 Eye 20/20 L SBDH-ABS-R SDBB 3000 black SDBB 3000 silver DRB 3000 black DRB 3000 silver LB 3300 VXB O Sockel Piezo DLI 3240 P X1 DLI 3240 P X2-R ABF ABF 19" B 12/ 26Ah CP ETB X2l HFM-SCH-M TA300 B 12/ 7,2Ah BE 24 73 73 55 31 81 40 40 10 16 67 67 67 63 96 43 69 5 4 6 6 12 13 13 13 81 60 83 81 24 24 36 6 67 85 86 85 86 86 89 89 84 83 84 90 90 18 84, 87 84, 87 46 56 58 74 65 75 54 43 43 44 44 85 44 8 14 24 25 22 17 55 97 24 89 101 www.detectomat.com Terms & Conditions of Sale detectomat GmbH 1 General – Controlling Provisions 4 Delivery – Delayed Acceptance – Delayed Delivery 1. No terms and conditions other than our Terms and Conditions of Sale contained herein shall apply unless expressly approved in writing by us. Our Terms and Conditions of Sale shall also apply in the event we make delivery to the customer without objection although aware of the existence of terms and conditions of the customer that differ from our Terms and Conditions of Sale. All agreements made between us and the customer in connection with the execution of this agreement are contained herein in writing. This agreement may not be altered, supplemented or amended unless agreed to in writing. Our Terms and Conditions of Sale shall apply to transactions with businessmen (“Unternehmer”) in the sense of Section 14 German Civil Code, legal entities and public institutions. Our Terms and Conditions of Sale shall also apply to all present and future commercial relations with the customer. 1. Delivery dates are subject to timely receipt by us of all documentation to be supplied by the customer, required permits and approvals, including but not necessarily limited to plans, and are also subject to performance of other obligations by the customer. If these conditions are not fulfilled in due time, delivery shall be delayed accordingly. This shall not apply in the event of delays for which we are responsible. Our obligation to make delivery is contingent upon timely and proper performance of the customer’s obligations. We reserve the right at our option to consider failure to perform (Section 320 German Civil Code - BGB) and impairment of performance (Section 321 German Civil Code - BGB) as events of default. We may make partial delivery if no undue convenience is caused to the customer. In the event delivery or shipment is delayed by the customer by more than one month from the date of announcement to the effect that the merchandise is ready for delivery or shipment, we may invoice the customer for storage charges in the amount of 0.5% of the price of the respective merchandise per month or any fraction thereof, in which case such charges may not exceed a total of 5%. The parties to the agreement may claim higher or lower storage costs if any difference can be documented. In the event the customer delays acceptance or fails to perform other obligations, we may at our option claim reimbursement for any related damages sustained by us, including but not necessarily limited to reimbursement for additional expenses, without prejudice to further claims. In the event of a situation pursuant to Section 5 above, risk of loss or damage shall pass to the customer upon the occurrence of any such dlay or default on the part of the latter. All acts of God (e.g. mobilization, war, insurrection, strikes, lockout or similar events) beyond our control shall release us from performance of our contractual obligations for the duration of any such occurrences. We will immediately inform the customer of our inability to perform our obligations under the agreement and promptly refund to the customer any corresponding payment received by us . In the event the duration of such an occurrence exceeds a period of three months, we may cancel the agreement. In the event delivery is delayed by us, our liability is limited to that prescribed by law if the underlying purchase agreement specifies a firm delivery date in the sense of Section 286 (2) 4 German Civil Code (BGB) or Section 376 German Commercial Code (HGB) pertaining to non-fulfillment. We are also liable as prescribed by law in the sense that the customer may claim that it is no longer interested in further performance due to a delay in delivery caused by us. We are also liable as prescribed by law for any delivery delay due to breach of the agreement due to willful or gross negligence. We assume responsibility for acts of negligence on the part of our representatives or agents. In the event the delivery delay is not due to breach of the agreement through willful negligence by us, our liability is limited to claims for damage that normally could have been anticipated. We are also liable as prescribed by law in the event delivery is delayed through breach of a material obligation under the agreement through negligence. In such cases, however, liability is limited to claims for damages normally could have been anticipated. In addition, we are liable for a flatrate penalty for delayed delivery in the amount of 0.5% of the price of the respective merchandise per entire week, which penalty may, however, not exceed a total of 5%. Any other legal rights and remedies the customer may have shall remain in effect. 2. 3. 4. 2 Acceptance of Orders 1. Our offers are subject to change. We reserve the right to make reasonable technical changes or changes in design, color and/or weight. In the case of orders pursuant to Section 145 German Civil Code (BGB), we may at our option accept such orders within 2 weeks of receipt. Unless specified otherwise in these Terms and Conditions of Sale or in our written confirmation, the INCOTERMS shall apply in the version effective as of the date of this agreement. Delivery is contingent upon correct and timely delivery of necessary materials or merchandise to us (“Obtaining supplies oneself clause”). We will inform the customer without delay in the event of non-availability and promptly refund any payment received. All rights to illustrations, drawings, calculations and other documents shall remain our property. This shall also apply to any written materials designated as “confidential”. The customer shall obtain our express approval in writing before making any such materials available to other parties. 2. 3. 4. 5. 3 Prices – Terms of Payment 1. Unless specified otherwise in our written confirmation, our prices are “ex works“ (exw) and exclusive of packing, which will be invoiced separately. We reserve the right to modify our prices accordingly in the event of increases or decreases in costs, including but not necessarily limited to increases or decreases due to wage agreements or changes in the prices of materials. We will document any such changes at the customer’s request. In the event delivery is to be made more than four months from the date of acceptance of the order or cannot be made earlier for reasons for which the customer is exclusively responsible, we reserve the right to invoice the appropriate price as of the date of delivery instead of the original price agreed upon. Our prices are exclusive of applicable value added tax (VAT). Applicable value added tax will be included separately in the invoice on the billing day. Unless specified otherwise in our written confirmation, the customer shall pay the net purchase price (with no deductions) within 10 days of receipt of the invoice, at which time the invoice shall become due and payable. Legal remedies shall apply in the case of past due accounts. The customer may offset amounts due to the customer only if the corresponding counterclaims are unappealable or undisputed or recognized by us. In addition, the customer may exercise the right to withhold payment only in the case of counterclaims in connection with the same transaction. 2. 3. 4. 5. 6. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 102 www.detectomat.com Terms & Conditions of Sale detectomat GmbH 5 Cancellation 1. The customer may cancel the agreement as allowed by law only in the event of culpable default by us. However, in the case of defects (Section 7 below), legal remedies shall apply. The customer shall in the event of default by us inform us within a reasonable period after being asked to do so by us whether it intends to cancel the agreement due to the event of the default or whether it insists upon delivery. 2. 6 Transfer of Risk of Loss or Damage 1. Unless specified otherwise in our written confirmation, our prices are understood to be “ex works“ (exw). We reserve the right to ship merchandise from locations other than the place of delivery. At the request of the customer, we will have the merchandise insured during transport, in which case the customer shall bear the corresponding costs. 2. 7 Claims for defects 1. Claims for defects may not be made in the event of insignificant deviations from the agreed upon characteristics, insignificant impairment of functionality, normal wear and tear or damage resulting from improper or negligent treatment after risk of loss or damage passes to the customer, excessive use, unsuitable operating consumables, improper site preparation or unusual external factors not provided for in the agreement or in the event of intermittent software problems. In the event of improper modifications or maintenance by the customer, we can assume no responsibility for such modifications or maintenance or the ramifications thereof. The customer’s rights in the case of a defect are dependent upon proper inspection and notification in compliance with Section 377 German Commercial Code (HGB). Notification of defects must be made in writing. The customer shall bear the burden of proof in connection with all such claims, including but not necessarily limited to proof of the existence of the defect, the time of occurrence of the defect and timely notification of the defect. In the event of notification of a defect, the customer may withhold payment only in a reasonable amount with respect to the extent of the defect. The customer may not refuse to accept delivery in the event of insignificant defects. In the event of a defect, we may at our option repair the defective merchandise or deliver new merchandise free of defects to replace the original merchandise. In the event the repair is unsuccessful, the customer may at its option cancel the agreement or request a reduction in price. In the event of negligible defaults, including but not necessarily limited to negligible defects, the customer may not cancel the agreement. We are liable as prescribed by law for claims made by the customer based on willful or gross negligence on the part of our representatives or agents. In cases other than intentional breach of the agreement, our liability for damages is limited to claims for damages that normally could have been anticipated. We are liable as prescribed by law in the event we commit a material breach of the agreement. In such cases, however, our liability for damages is limited to claims for damages that normally could have been anticipated. We assume liability for injury to the life, body or health through negligence on our part. This also applies to compulsory liability pursuant to product liability legislation (“Produkthaftungsgesetz”). Any other form of liability not specified above is excluded. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Claims for defects must be reported within 12 months. In the event the newly manufactured product is a structure or is on the basis of its normal function used for a structure and has caused a defect in such a structure, an exception will be made and the period for reporting claims will be extended to 36 months. Our legal liability pursuant to Sections 6 and 8 and in the case of willful deceit shall not be affected. The period for reporting claims pursuant to Sections 478 and 479 German Civil Code (BGB) shall not be affected and shall extend for a period of five years from the date of delivery of the defective item. Recourse against us pursuant to Section 478 German Civil Code – BGB – (recourse of customer) is only possible in the event the customer has not made any agreement with its customer that goes beyond legal liability for defects. 8 General Liability 1. Liability for damages other than that provided for in Section 7 is excluded, regardless of the legal nature of the claim, including but not necessarily limited to claims for damages due to negligence in connection with the acceptance of the order, other breaches of obligations or claims for damages to property pursuant to Section 823 German Civil Code (BGB). The exclusion pursuant to Section 8.1 above also applies in the event the customer claims reimbursement for needlessly incurred expenses instead of damages. Insofar as liability for damages is excluded or limited, this shall also apply to claims for damages against our employees, representatives and agents. 2. 3. 9 Usage of software and firmware – industrial property rights 1. The customer has the non-exclusive right to use the standard software and firmware, with the agreed performance characteristics, in an unmodified form and within the agreed devices. The customer may make a backup copy of the standard software without the need for an express agreement. The goods supplied by us are subject to industrial property rights (e.g. patent rights, trademark rights and ownership rights). The customer shall, in the case of applying or using the goods, respect our industrial property rights, as well as the industrial property rights of third parties. 2. 10 Retention of Title 1. We retain title to the merchandise until all payments from business with the customer are made in full. In the event the customer has an account with us, our reservation of title also applies to any acknowledged outstanding balance, and the same applies in the event a balance is not acknowledged and a “balance is made for cause”, for example, in the event of bankruptcy or insolvency by the customer. In the event of breach of this agreement by the customer, including but not necessarily limited to failure to make payment when due, we may retake possession of the merchandise sold without canceling the agreement beforehand. The customer hereby agrees to allow us to enter its business premises during normal business hours to retake possession of the items in question in any such situation. After retaking possession of the items sold, we may dispose of them and credit the proceeds, less appropriate disposal costs, to the outstanding balance due us. The customer shall take proper care of the merchandise and shall have the merchandise adequately insured at new value at its own expense against fire damage, flood damage and theft. In the event maintenance and inspections are necessary, the customer shall have such work caried out on a timely basis at its own expense. 2. 3. 103 www.detectomat.com Terms & Conditions of Sale and references detectomat GmbH 4. 5. 6. 7. 8. 9. 10. 11 In the event of attachment or any other such proceeding initiated by third parties, the customer shall inform us in writing so that we can take action pursuant to Section 771 Code of Civil Procedure (ZPO). In the event any such third party is not in a position to reimburse us for legal and extrale-gal expenses resulting from such an action pursuant to Section 771 Code of Civil Procedure (ZPO), the customer shall bear any such expenses. The customer may resell the merchandise in the normal course of its business. However, the customer shall assign the full invoiced amount (including VAT) due from its customer or other parties from the sale to the outstanding balance due to us; and this condition shall apply whether or not the merchandise purchased from us is sold without or after processing. The customer shall remain authorized to collect the amount due after assignment to us. Our right to make collection ourselves remains unaffected. However, we agree to refrain from making collection as long as the customer applies the proceeds from the sale to meet its payment obligations toward us, is not in arrears and, in particular, no insolvency proceeds have been opened against the customer and the customer has not suspended payment. In any such event, we may demand that the customer make known to us the assigned receivables and the corresponding debtors, provide all information required for collection, make available the corresponding documents and inform the debtors (third parties) of the assignment. The processing or modification by the customer of the merchandise is in all cases performed for us. In the event the merchandise is processed with other objects that are not our property, we acquire partial ownership of the object in proportion to the value of the merchandise (total invoice amount, including VAT) as compared with that of the other processed objects at the time of the processing. In addition, the same reservation of title that applies for the merchandise also applies for the object that results from the processing. In the event the merchandise is inextricably combined with objects that are not our property, we acquire partial ownership of the new object in proportion to the value of the merchandise (total invoice amount, includ-ing VAT) as compared with that of the other combined objects at the time they are combined. In the event the combination is such that the property of the customer is to be considered the main product, it is agreed that the customer shall transfer proportionate ownership rights to us. The cutomer shall then hold the resultant sole or partial property for us. The customer shall also assign to us those amounts due from third parties as a result of the attachment of the merchandise to real estate property to secure amounts due to us. In the event the reservation of title or assignment is not effective in the jurisdiction in which the object is located, it is agreed that the security corresponding to reservation of title or assignment in that jurisdiction shall obtain. If the creation of this security requires actions on the part of the customer, the latter shall at our request take any and all measures required to create and maintain such rights at its own expense. We agree to release securities in our favor at the request of the customer in the event the realizable value of sure securities exceeds the value of the secured amounts due by more than 10%. We may determine at our own discretion which securities to release. 12 Venue – Place of Delivery – Governing Law Support and Assistance President: If, in addition to supplying merchandise, we also provide the customer with support and/or assistance with the installation/start-up of the merchandise, the limitation of liability described in Sections 7 and 8 shall apply accordingly. Dipl.-Ing. Eduard J. Job 1. 2. 3. 4. This agreement shall be subject to the exclusive jurisdiction of the courts of our principal place of business in the event the customer is a businessman in the sense of Section 14 German Civil Code (BGB), a legal entity or a public institution. We may, however, file suit against the customer before the courts of the customer’s principal place of business. In the event the customer is a businessman in the sense of Section 14 German Civil Code (BGB), a legal entity or a public institution and nothing is specified to the contrary in our written confirmation, our principal place of business shall be the place of delivery. This agreement shall be governed by the laws of the Federal Republic of Germany. Application of the United Nations Convention on Contracts for the International Sale of Goods (1980) – CISG – is expressly excluded. In the event of differences of opinion arising from these Terms and Conditions of Sale or in the case of doubt, the original German-language version and it alone shall be legal and binding. Terms & Conditions of Sale detectomat GmbH, revised 15. August 2006 Technical Modifications Due to continuous development of our products, together with altering manufacturing methods, the descriptions and data provided are for information only and subject to changes without notice. Information given in the catalogue We accept no responsibility for the accuracy of the information and prices given in the catalogue. Our prices are exclusive of applicable value added tax (VAT). Applicable value added tax will be included separately in the invoice on the billing day. Updates you will find at www.detectomat.com detectomat GmbH An der Strusbek 5, 22926 Ahrensburg, Germany Amtsgericht Lübeck, HR B 4645 AH CFO: Dipl.-Ing. Bodo Müller 104 www.detectomat.com detectomat GmbH An der Strusbek 5 D-22926 Ahrensburg Germany detectomat GmbH Werk Bielefeld Elpke 106–108 D-33605 Bielefeld, Germany JOB GmbH Kurt-Fischer-Straße 30 D-22926 Ahrensburg Germany Tel.: +49 (0) 4102 – 2114 – 60 Tel.: +49 (0) 521 – 924 31 – 0 Tel.: +49 (0) 4102 – 2114 – 0 Fax: +49 (0) 4102 – 2114 – 670 Fax: +49 (0) 521 – 924 31 – 50 Fax: +49 (0) 4102 – 2114 – 70 E-Mail: [email protected] E-Mail: [email protected] E-Mail: [email protected] Web: www.detectomat.com Web: www.detectomat.com Web: www.Job-Bulbs.com The Group www.detectomat.com
Benzer belgeler
conventional wisdom
2 slots for fire brigade and network interface
128 programmable detector zones
up to 4 x 126 loop3000 components
up to 16 inputs for conventional detector zones
maximum loop length 3.000 m (using i...