RT 12260
Transkript
RT 12260 (12V26Ah) RT 12260 is a general purpose battery with 5 years floating design life , meet with IEC, JIS standard .With heavy duty grid, thickness plates, special additives, RT series battery have long and reliable standby service life. Specification Cells Per Unit 6 Voltage Per Unit 12 Capacity 26Ah@20hr-rate to 1.75V per cell @25 oC Weight Approx. 8.10 Kg Max. Discharge Current 260 A (5 sec) Internal Resistance Approx. 10 mΩ Operating Temperature Range Discharge: -20 C ~60 C Charge: 0 oC~50 oC Storage: -20 oC~60 oC Normal Operating Temperature Range 25 oC±5 oC Float charging Voltage 13.7 to 13.9 VDC/unit Average at 25 oC Recommended Maximum Charging Current Limit 7.8 A Equalization and Cycle Service 14.6 to 14.8 VDC/unit Average at 25 oC Self Discharge RITAR batteries can be stored for more than 6 months at 25 oC. Self-discharge ratio less than 3% per month at 25 oC. Please charge batteries before using. Terminal Faston F3/F13 Constainer Material A.B.S. (UL94-HB) , Flammability resistance of UL94-V2 can be available upon request. o o Dimensions Unit: mm Terminal F13 Dimension: 166(L)×175(W)×125(H) Terminal F3 Constant Current Discharge Characteristics : A(25 oC) F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR 9 .60V 93.35 66.89 48.6 7 29.90 16.90 10.37 6.786 5.616 4.420 3.230 2.731 1.44 4 1 0.0V 90.85 63.65 47.6 7 29.41 16.82 10.30 6.760 5.590 4.394 3.203 2.705 1.41 8 1 0.2V 85.61 61.40 46.9 2 29.15 16.67 10.22 6.708 5.564 4.368 3.177 2.678 1.39 2 1 0.5V 76.88 56.66 44.6 8 28.42 16.51 10.14 6.682 5.512 4.316 3.151 2.652 1.36 5 1 0.8V 69.39 51.67 41.1 8 27.17 16.12 9.958 6.500 5.382 4.238 3.098 2.626 1.33 9 1 1.1V 60.40 46.18 36.9 4 25.45 15.31 9.516 6.214 5.122 4.056 2.967 2.547 1.26 0 Constant Power Discharge Characteristics : W(25 oC) F.V/Time 9 .60V 5MIN 889.1 10MIN 650 .1 15MIN 478.7 30MIN 337 .4 1HR 193.3 2HR 119.3 3HR 78.31 4HR 64.90 5HR 51 .17 8HR 37.48 10HR 30.71 20HR 16.2 2 1 0.0V 870.9 621 .0 468.7 333 .2 192.3 118.9 78.16 64.74 50 .86 37.32 30.39 16.0 6 1 0.2V 822.1 600 .3 462.4 329 .3 190.9 117.8 77.69 64.43 50 .70 37.00 30.23 15.9 0 1 0.5V 740.3 554 .7 440.9 321 .8 189.1 116.7 77.22 63.96 50 .23 36.69 29.92 15.7 5 1 0.8V 665.9 503 .6 405.1 307 .2 184.4 115.0 75.35 62.24 49 .45 35.90 29.60 15.5 9 1 1.1V 574.8 447 .3 361.7 287 .8 174.7 109.7 71.60 59.28 46 .96 34.64 28.66 14.9 6 All mentioned values are average values. 12V26Ah RT 12260 Storage characteristic 10 100 8 Capacity (%) 6 Life Expectancy (years) Supplementary charge required (Carry out supplementary charge before use if 100% capacity is requires) 0℃ 4 2 80 10℃ Supplementary charge required before use. This supplementary charge will help to recover the capacity and should be made as early as possible. 60 20℃ 40 30℃ 40℃ Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached 20 0 0 10 20 30 40 4 2 50 6 8 Storage Time (months) Battery Temperature (℃) Charge characteristic Curve for standby use 15 7.5 Discharge characteristic Curve 5.0 120 0.24 100 0.20 13 6.5 4.3 12 6.0 4.0 11 5.5 3.7 10 5.0 3.3 Chcrge Voltage 80 ① Discharge 100%(0.05CA×20h) 50%(0.05CA×10h) ② Charge Chcrge Voltage2.275V/C Charge Current0.1CA ③ Temperature 25℃ 60 40 0.16 0.12 0.08 Terminal Voltage (V) 4.7 Charge Current (CA) 7.0 Charge Volume (%) Charge Voltage(V) Chcrge Volume 14 Supplementary charge and storage guidelines 10 12 14 16 18 20 22 24 13 6.5 4.3 12 6.0 4.0 11 5.5 3.7 0.05C 10 5.0 3.3 9 4.5 3.0 0.62C 1C 3C 20 0.04 0 0 0.093C 0.16C 0.35C Charge Current 9 4.5 3.0 0 2 4 6 8 0.6 1.2 3 6 12 30 1 2 Charge Time(h) 5 10 20 24 Hr min 10 12 14 16 18 20 24 28 Discharge Time Capacity Factors With Different Temperature Battery Type -20℃ -10℃ 0℃ 5℃ 10℃ 20℃ 25℃ 30℃ 40℃ 45℃ GEL 6V&12V Battery 2V 50% 70% 83% 85% 90% 98% 100% 102% 104% 105% 60% 75% 85% 88% 92% 99% 100% 103% 105% 106% AGM 6V&12V Battery 2V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109% 55% 70% 80% 85% 92% 99% 100% 104% 108% 110% Maintenance & Cautions Discharge Current VS. Discharge Voltage Final Discharge Voltage V/cell 1.75V Discharge Current (A) (A)≤0.2C 1.60V 1.70V Float Service: ※ Every month, recommend inspection every battery voltage. 0.2C<(A)<1.0C (A)≥1.0C Charge the batteries at least once every six months, if they are stored at 25 oC. Charging Method: Equalization charge method: Discharge: 100% rate capacity discharge. Charge: Max. current 0.3CA, constant voltage 2.4-2.45V/Cell charge 24h. Constant Voltage -0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA Constant Current -0.2Cx2h+0.1CAx12h Fast -0.2Cx2h+0.3CAx4.0h SHENZHEN RITAR POWER CO.,LTD. URL:www.ritarpower.com ※ Every three months, recommend equalization charge for one time. ※ Effect of temperature on float charge voltage: -3mV/℃/Cell. ※ Length of service life will be directly affected by the number of discharge . cycles, depth of discharge, ambient temperature and charging voltage. Address: Rm405,Tower C, Huahan Building,Langshan Rd16, Nanshan District, ShenZhen, 518057, China Tel:+86-755-33981668 Fax:86-755-8347-5180 2008 - Version 1
Benzer belgeler
RA12-40
RITAR batteries can be stored for more than 6 months
at 25 oC. Self-discharge ratio less than 3% per month
at 25 oC. Please charge batteries before using.
BP65-12 - PowerStream
Ambient Temperature
Charge..........................................................................................................................................................0oC(32oF)~40oC(10...
PERFORMANCE SPECIFICATIONS Maintenance-Free - BB
Maximum Discharge Current For 5 sec.(A)...............................................................................................................................120A
Maximum Charge Current(A)....
Maintenance-Free Rechargeable Sealed Lead-Acid - BB
Charging Procedure
Temperature
Charging
compensation
Voltage
coefficient of
O
at 20 C
voltage
(V/cell) charging
(mV/ OC/cell)
BP26-12 - BB
Maximum Discharge Current For 5 sec.(A)..............................................................................................................................390A
Maximum Charge Current(A).....
BP7.5-12 - BB
Maximum Discharge Current For 5 sec.(A)...............................................................................................112.5A
Maximum Charge Current(A)..................................
Spec Sheet - House of Batteries
current
charging
For
(with current
cycle service restriction)
BP8-6V - BB
※ Effect of temperature on float charge voltage: -3mV/℃/Cell.
※ Length of service life will be directly affected by the number of discharge