UDR-10 - Entes
Transkript
UDR-10 - Entes
HBAR RÖLE KOMBNASYONU UDR SERS SIGNAL RELAY COMBINATION UDR SERIES General Genel UDR serisi ihbar röle kombinasyonlar trafo merkezlerindeki koruma sistemlerinde, kontrol sistemlerinde, enerji da¤tm sistemlerinde, alçak ve yüksek gerilim tesislerinde kullanlr. Sistemde olabilecek arzalar ihbar düzenine ileterek akustik ve optik ihbar alnmasn sa¤layan UDR serisi röleler iki tip olarak üretilmektedir; UDR-06 ve UDR-10. UDR series are developed for protection systems such as transformers, operation control systems, energy distribution systems, and high and lowvoltage systems. Having been developed in two different types, UDR series assert acoustic and optical warnings when faults are received from the systems. Kullanm ve Çalþma Prensipleri Operation Principles for UDR-06 UDR-06 UDR-06, 6 ihbar ünitesinden oluþur ve ihbar says kstl olan tesislerde kullanlr. ç ba¤lant þemasnda görüldü¤ü gibi, UDR-06da (UDR-10dan farkl olarak) röleler 3lü iki grup halinde monte edilmiþlerdir. Bu montaj þekli kullancya kumanda ve ihbar gerilimlerini ayrma olana¤ sa¤lar. Böylelikle 3 giriþ açma kumandas 3 giriþ ihbar için kullanlabilir. Bu özelliklerin dþnda çalþma prensibi UDR-10 ile ayndr ve "K" konta¤ üzerinden alnan ihbarla "R" rölesi kilitlenerek çalþr. UDR-06'da UDR-10'dan farkl olarak "J" rölesi korna rölesi görevini yapar ve böylelikle harici korna rölesi "AR-01" ba¤lamak gerekmez. (R) rölesinin(r2) konta¤ ise de¤iþik maksatlar için veya toplam ihbar çkþ için kullanlabilir. UDR-10 UDR-10, 10 ihbar ünitesinden oluþur ve ihbar says fazla olan tesislerde kullanlr. ç ba¤lant þemasnda görüldü¤ü gibi, koruma düzeninin (k) konta¤ üzerinden alnan arza ihbar "R" rölesini çektirir ve "R" rölesi "r" konta¤ üzerinden kendisini kilitler. Ayn anda "r3" konta¤ da þkl ihbar göstergesindeki ilgili sinyal lambasn yakar. Cihaz üzerindeki "J" rölesi de konta¤n kapatp açar ve ilgili klemens uçlarna ksa süreli bir darbe (impuls) gönderir. Bu uçlara ba¤l olan "AR-01" korna rölesi bu darbe ile kilitlenerek "EK-01" kornasnn çalþmasn sa¤lar. "R" rölesinin "r2" konta¤ ise de¤iþik maksatlar için veya toplam ihbar çkþ için kullanlabilir. ç Ba¤lant þemas (UDR-06) K1 K2 K3 K4 K5 K7 K18 K6 8 29 1r1 6r1 R6 R1 UDR-06 is developed for protection systems with a limited number of signal sources. It has 6 input and 6 output terminals. As shown in internal circuit diagram below, UDR-06 is installed in two groups each of which contains 3 relays in contrast with UDR-10. This configuration allows the user to separate the command and signal patches. Three of the inputs may be used for tripping commands and the other three inputs for the monitoring. Excluding the above differences, the operation principle is the same as UDR-10. Relay R is activated (pulls) with the fault indication coming through the contact K. It is locked on by contacts r1. The relay W acts the same as in UDR-10. The difference is that the relay J functions as the horn relay. The contacts r2 of the relay R may be used for different purposes such as giving the total signal output. Operation Principles for UDR-10 UDR-10 is developed for protection systems up to 10 entry and outlet points. As shown in internal circuit diagram below, fault tripping fed through contact K of the protection system operates the relay R, which in turn locks itself over contact r1. At the same time, contact r3 turns "ON" the corresponding signal lamp on the announcer and unit relay J in the device switches its contacts ON and OFF transmitting a short impulse to terminal number 26 (see the connection diagram). The horn relay (AR-01) connected to terminal 26 is locked with this impulse and operates the horn EK-01. On the other hand, contact r2 of the relay R may be used for different purpose such as giving the total alarm signal. Ba¤lant þemas (UDR-06) Internal Circuit Diagram for UDR-06 Pm K1 B3 K1 K2 K3 K4 K5 K6 K2 K3 K4 K5 K6 K7 K18 8 29 19 W 20 30 17 J 1 J2 B2 L1 L2 L3 L4 L5 1 J W 1r1 2 3 4 5 6 7 R6 R1 9 10 11 12 13 14 15 8 6r1 1r2 6r2 26 25 24 23 22 21 9 10 1r3 6r3 11 12 13 14 15 W J1 J2 20 30 17 B2 L1 L2 L3 L4 L5 1 1r2 26 25 24 23 22 21 9 10 Toplam hbar 4 5 6 7 8 9 10 11 12 13 14 15 Nm + EK 01 1r3 + 12 13 14 15 2 3 4 5 6 7 8 10 r1 EK 01 - 16 Connection Diagram for UDR-10 K25 K26 Pm K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 L1 L2 L3 L4 L1 L2 L3 L4 1 Total signal 6r3 K 1 K 2 K 3 K 4 K 5 K 6 K 7 K 8 K 9 K10 K21 Pm B1 L6 Nm Internal Circuit Diagram for UDR-10 Ba¤lant þemas (UDR-10 ) K25 K26 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 R10 3 28 6r2 B1 L6 ç Ba¤lant þemas (UDR-10) 1r1 2 27 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 11 R1 B3 K1 K2 K3 K4 K5 K6 J W 16 K 1 K 2 K 3 K 4 K 5 K 6 K 7 K 8 K 9 K10 K21 Pm 19 27 28 Connection Diagram for UDR-06 1 9 10 11 12 13 14 1 1r1 R1 2 3 R10 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 10 r1 3 15 16 17 18 19 20 21 22 23 24 25 26 27 28 W J 1r2 10 r2 1r3 10 r3 11 12 13 14 15 16 17 18 19 20 22 23 24 15 16 17 18 19 20 21 22 23 24 25 26 27 28 B2 L5 L6 L7 L8 L9 L10 27 Nm 28 B1:Korna susturma butonu (uyar sonras çalþan kornay susturmak içindir). B2:hbar silme butonu (þkl ihbar silmek Toplam ihbar için kullanlr). B3:Lamba test butonu (B3'e basld¤nda bütün lambalar yanar). Teknik Bilgi W 1r2 B1 a1 1 2 AR 01 3 + a2 _ 10 r2 Korna Rölesi EK 01 1r3 10 r3 11 12 13 14 15 16 17 18 19 20 B2 22 23 Nm B3 B1 L5 L6 L7 L8 L9 L10 24 27 28 a2 a1 Total signal B1 : Horn reset button (used for switching OFF the horn) B2 : Signal Switch-OFF button (used for switching OFF the signal lights) B3 : Lamp test button (turns the lamps ON) 1 2 AR 01 3 + a2 a2 _ Alarm Horn Relay EK 01 Technical Data þletme Gerilimi (Un) : 24 VDC, 110 VDC þletme Aral¤ : (0.80-1.20) x Un (24 V için) (0.85-1.15) x Un (110 V için) Çkþ Kontaklar : 1 Enversör, 6A, 1250VA (250 W DC) Ortam Scakl¤ : -5°C ; +50°C Boyutlar : Tip UR 28 Koruma Snf : IP 20 Ba¤lant þekli : Pano içine dikey A¤rlk : 1.5 kg Güvenli Kullaným ve Kurma Ýçin Uyarýlar J B3 Rated Voltage (Un) Operating Range : 24VDC, 110 VDC : (0.80-1.20) x Un (for 24 V) (0.85-1.15) x Un (for 110 V) Output Contacts : 1 C/O with 6A,1250VA Ambient Temperature : -5°C to +50°C Dimensions : Type UR 28 Protection Class : IP 20 Installation : Projection mounting with front connectors Weight : 1.5 kg Aþaðýdaki talimatlara uyulmamasý halinde yaralanma veya ölümle sonuçlanabilecek durumlar ortaya çýkabilir. Cihaz üzerindeki herhangi bir iþlemden önce tüm besleme gerilimlerini kesiniz. Cihaz þebekeye baðlý iken cihazýn kutusunu açmayýnýz. Cihazý solvent veya benzeri maddelerle temizlemeyiniz. Cihazý temizlemek için sadece kuru bez kullanýnýz. Cihazý çalýþtýrmadan önce baðlantýlarýnýn doðru olduðunu kontrol ediniz. Cihazý panoya monte ediniz. Cihazýnýzdaki herhangi bir sorunda yetkili satýcýnýzla temas kurunuz. PRECAUTIONS FOR INSTALLATION AND SAFE USE Failure to follow those instructions will result in death or serious injury. Disconnect all power before working on equipment. When the device is connected to the network, do not open the cover. Do not try to clean the device with solvent or the like. Only clean the device with a dried cloth. Verify correct terminal connections when wiring. Electrical equipment should be serviced only by your compedent seller. No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences arising out of the use of this material. Only for rack panel mounting. A2408/Rev.2
Benzer belgeler
MCC-1D - Entes
Delay ON time can be adjusted between 5-15 minutes with the knob on the front panel.
"On" is the Power LED; "Out" is the normal LED.
1- When the device is supplied for the first time , "On" LED is ...