(Low-E) + Kuru Hava + Lamine Cam
Transkript
(Low-E) + Kuru Hava + Lamine Cam
08 EN 1279-5 Insulating glass units, intended to be used in buildings and construction works 4 (# 2) - 12 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) + Laminated glass (Clear Float Glass+Transparent PVB+Clear Float Sinerji Glass) Characteristics Resistance to fire Reaction to fire External fire behaviour Bullet resistance Explosion resistance Burglar resistance (EN 356) Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance of the glass unit Direct airborne sound reduction Thermal properties U-value (EN 673) Normal emissivity (EN 12898) Radiation properties Light transmission and reflection Solar energy characteristics NPD: No Performance Determined NPD NPD NPD NPD NPD NPD NPD - 12 - 2 (B) 2 NPD 4 - 12 - 33.1 32 (-1; -3) dB 1,6 W / (m 2K) NPD 0,77/0,12/0,11 0,46/0,25/0,18 08 EN 1279-5 Insulating glass units, intended to be used in buildings and construction works 4 (# 2) - 16 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) + Laminated glass (Clear Float Glass+Transparent PVB+Clear Float Sinerji Glass) Characteristics Resistance to fire Reaction to fire External fire behaviour Bullet resistance Explosion resistance Burglar resistance (EN 356) Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance of the glass unit Direct airborne sound reduction Thermal properties U-value (EN 673) Normal emissivity (EN 12898) Radiation properties Light transmission and reflection Solar energy characteristics NPD: No Performance Determined NPD NPD NPD NPD NPD NPD NPD - 16 - 2 (B) 2 NPD 4 - 16 - 33.1 32 (-1; -3) dB 1,3 W / (m 2K) NPD 0,77/0,12/0,11 0,46/0,25/0,18 08 EN 1279-5 Insulating glass units, intended to be used in buildings and construction works 6 (# 2) - 12 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) + Laminated glass (Clear Float Glass+Transparent PVB+Clear Float Sinerji Glass) Characteristics Resistance to fire Reaction to fire External fire behaviour Bullet resistance Explosion resistance Burglar resistance (EN 356) Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance of the glass unit Direct airborne sound reduction Thermal properties U-value (EN 673) Normal emissivity (EN 12898) Radiation properties Light transmission and reflection Solar energy characteristics NPD: No Performance Determined NPD NPD NPD NPD NPD NPD NPD - 12 - 2 (B) 2 NPD 6 - 12 - 33.1 33 (-2; -5) dB 1,6 W / (m 2K) NPD 0,76/0,11/0,11 0,46/0,22/0,18 08 EN 1279-5 Insulating glass units, intended to be used in buildings and construction works 6 (# 2) - 16 - 33.1, Heat Control Glass (Low-E #2) + Dry Air (100%) + Laminated glass (Clear Float Glass+Transparent PVB+Clear Float Sinerji Glass) Characteristics Resistance to fire Reaction to fire External fire behaviour Bullet resistance Explosion resistance Burglar resistance (EN 356) Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance of the glass unit Direct airborne sound reduction Thermal properties U-value (EN 673) Normal emissivity (EN 12898) Radiation properties Light transmission and reflection Solar energy characteristics NPD: No Performance Determined NPD NPD NPD NPD NPD NPD NPD - 16 - 2 (B) 2 NPD 6 - 16 - 33.1 33 (-2; -5) dB 1,3 W / (m 2K) NPD 0,76/0,11/0,11 0,46/0,22/0,18 08 EN 1279-5 Insulating glass units, intended to be used in buildings and construction works 6 (# 2) - 12 - 44.1, Heat Control Glass (Low-E #2) + Dry Air (100%) + Laminated glass (Clear Float Glass+Transparent PVB+Clear Float Glass) Characteristics Resistance to fire Reaction to fire External fire behaviour Bullet resistance Explosion resistance Burglar resistance (EN 356) Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance of the glass unit Direct airborne sound reduction Thermal properties U-value (EN 673) Normal emissivity (EN 12898) Radiation properties Light transmission and reflection Solar energy characteristics NPD: No Performance Determined NPD NPD NPD NPD NPD NPD - 12 - P1A NPD - 12 - 2 (B) 2 NPD 6 - 12 - 44.1 33 (-2; -5) dB 1,6 W / (m 2K) NPD 0,76/0,11/0,11 0,45/0,22/0,18 08 EN 1279-5 Insulating glass units, intended to be used in buildings and construction works 6 (# 2) - 16 - 44.1, Heat Control Glass (Low-E #2) + Dry Air (100%) + Laminated glass (Clear Float Glass+Transparent PVB+Clear Float Glass) Characteristics Resistance to fire Reaction to fire External fire behaviour Bullet resistance Explosion resistance Burglar resistance (EN 356) Pendulum body impact resistance Resistance against sudden temperature changes and temperature differentials Wind, snow, permanent and imposed load resistance of the glass unit Direct airborne sound reduction Thermal properties U-value (EN 673) Normal emissivity (EN 12898) Radiation properties Light transmission and reflection Solar energy characteristics NPD: No Performance Determined NPD NPD NPD NPD NPD NPD - 16 - P1A NPD - 16 - 2 (B) 2 NPD 6 - 16 - 44.1 33 (-2; -5) dB 1,3 W / (m 2K) NPD 0,76/0,11/0,11 0,45/0,22/0,18
Benzer belgeler
(MF 171) + +Argon + Lamine Cam
Insulating glass units, intended to be used in buildings and
construction works
6 (# 2) - 12 - 33.1, Thermally Toughened Heat and Solar Control
Coating on Helio® Green (MF 270 #2) + Dry Air (%100) ...
Renksiz Float Cam + Şeffaf PVB + Renksiz Float Cam
Insulating glass units, intended to be used in buildings and
construction works
4 - 12 - 33.1, Thermally Toughened Helio® Bronze + Dry Air (%100) +
Laminated glass (Clear Float Glass+Transparent PV...