Hemoglobin A1c Calibrator Set
Transkript
Hemoglobin A1c Calibrator Set
Hemoglobin A1c Calibrator Set INTENDED USE FOR IN VITRO DIAGNOSTIC USE This product is for the purpose of calibrating the Cliniqa Hemoglobin A1c (HbA1c) assay. SUMMARY Throughout the circulatory life of the red cell, HbA1c is formed continuously by the adduction of glucose to the N-terminal of the hemoglobin beta chain. This process, which is non-enzymatic, reflects the average exposure of hemoglobin to glucose over an extended period. In a classical study, Trivelli, et al, (1) showed HbA1c in diabetic subjects to be elevated 2-3 fold over the levels found in normal individuals. Several investigators have recommended HbA1c serve as an indicator of metabolic control of the diabetic, since HbA1c levels approach normal levels for diabetics in metabolic control. (2,3,4). HBA1c has been defined operationally as the “fast fraction” hemoglobins (HbA1a, A1b, A1c) that elute first during column chromatography with cation-exchange resins. The non-glycosylated hemoglobin, which consists of the bulk of the hemoglobin, has been designated HbA0. The present procedure utilizes an antigen and antibody reaction to directly determine the concentration of HbA1c. PRINCIPLE OF PROCEDURE The lyophilized HbA1c calibrators are hemolysates prepared from packed human erythrocytes. Stabilizers are added to maintain hemoglobin in the reduced state for the accurate calibration of the HbA1c procedure. REAGENT PREPARATION Reconstitute each vial with 0.5 ml of deionized water. Gently mix for 10 minutes or until all material has dissolved. STORAGE AND STABILITY Store at 2-8°C. Stable until the expiration date if sealed tightly. PROTECT FROM LIGHT AND HEAT. The reconstituted calibrators should be stored at 2-8°C and sealed tightly. The calibrators retain their assigned values for at least 30 days if stored at 2-8°C and sealed tightly. WARNINGS AND PRECAUTIONS 1. Good laboratory safety practices should be followed when handling any laboratory reagent. Refer to a recognized laboratory safety program for additional KULLANIM AMACI IN VITRO TANISAL KULLANIM İÇİNDİR Bu ürün, Cliniqa Hemoglobin A1c (HbA1c) testi kalibrasyonu için üretilmiştir. ÖZET Kırmızı kan hücrelerinin yaşam döngüsü boyunca, HbA1c, hemoglobin beta zincirinin N terminaline glikoz eklenmesi ile sürekli olarak oluşturulur. Enzimatik olmayan bu işlem, hemoglobinin belirli bir süre boyunca glükoza ortalama olarak maruz kalma oranını yansıtır. Klasik bir çalışmada, Trivelli, ve diğ., (1) HbA1c'nin diyabet hastalarında normal bireylere nazaran 2-3 kat daha hızlı bir şekilde yükseldiğini gösterilmiştir. Birkaç araştırmacı, HbA1c'nin diyabetin metabolik kontrolü konusunda bir gösterge olarak kullanılmasını önermiş, HbA1c düzeylerinin metabolik kontrolde diyabet hastalarında normal seviyelere eriştiğini belirtmiştir. (2,3,4).HBA1c, çalışma olarak katyon yüklü iyon değiştirici reçineler ile kolon kromatografisi sırasında eluata geçen ilk "hızlı fraksiyon" hemoglobinler(HbA1a, A1b, A1c) olarak tanımlanmıştır. Kanda bulunan Hemoglobinler arasında,glikolize edilmemiş hemoglobin, HbA0 olarak tanımlanmıştır. Mevcut prosedür, HbA1c konsantrasyonunun doğrudan belirlenmesi için bir antijen ve antikor reaksiyonundan faydalanmaktadır. PROSEDÜR PRENSİPLERİ Liyofilize edilmiş HbA1c kalibratörleri insan eritrositlerinden hazırlanan hemolizatlardır. Hemoglobinin HbA1c prosedürünün doğru kalibrasyonun sağlamak adına dengeleyiciler indirgenmiş halleri ile eklenmektedir. REAKTİF HAZIRLIĞI Her flakonu 0,5 ml deiyonize su ile çözün. Tüm materyaller çözünene kadar 10 dakika boyunca nazikçe çalkalayın. SAKLAMA VE STABİLİTE 2-8°C sıcaklıkta saklayın. Sıkıca kapatıldığı takdirde stabil kalacaktır. IŞIK VE ISIDAN KORUYUN. Yeniden yapılandırılmış kalibratörler 2-8°C sıcaklıkta, sıkıca kapatılmış şekilde saklanmalıdır. Kalibratörler 2-8°C sıcaklıkta, sıkıca kapatılmış şekilde saklandıkları takdirde belirlenen değerleri en az 30 gün boyunca korunacaktır. UYARILAR VE ÖNLEMLER 1.Herhangi bir laboratuvar maddesi ile ilgilenirken iyi laboratuvar güvenlik uygulamalarının izlenmesi gerekmektedir. Daha fazla bilgi için saygın bir laboratuar information. (See GP17-T, Clinical Laboratory Safety; Tentative Guideline (1994), National Committee on Clinical Laboratory Standards, Wayne, PA.) 2. Results should be interpreted considering all other test results and clinical status of the patient. 3. Although this product has been tested and found non-reactive for Hepatitis B surface antigen (HbsAG) and HIV, no known test can offer the assurance that products derived from human blood will not transmit disease. Therefore all human serum and patient samples should be handled in the same manner as an infectious agent. 4. Avoid ingestion and contact with skin and mucous membranes. PROCEDURE Materials provided 85962 4 x 0.5mL Materials required but not provided 1. HbA1c reagent kit 2. 0.5 ml pipette 3. Deionized water TEST PROCEDURE The calibrators should be treated in the same manner as patient specimens in the hemolysate procedure with the following exception. Preparation of the calibrators does not require centrifugation to achieve packed cells. Follow the directions of the reagent kit and the instrument application instructions. SETPOINT VALUES See values listed. The setpoint values were obtained by assaying representative samples of the entire lot against NGSP reference materials using the Cliniqa HbA1c reagent kit. Things to look for that might cause inaccurate results are improper pipetting, inadequate mixing and poorly calibrated instruments. REFERENCES 1. Trivelli, L.A., Ranney, H.M., and Lai, H.T., New Eng. J. Med. 284, 353 (1971). 2. Gonen, B. and Rubenstein, A.H., Diabetologia 15,1 (1978). 3. Gabbay, K.H., Hasty, K., Breslow, J.L., Ellison, R.C., Bunn, H.F., and Gallop, P.M., J. Clin. Endocrinol. Metab. 44, 859 (1977). 4. Bates, H.M., Lab. Manag., Vol. 16 (Jan: 1978). güvenlik programına başvurun. (Bkz. GP17-T, Clinical Laboratory Safety; Tentative Guideline (1994), National Committee on Clinical Laboratory Standards, Wayne, PA.) 2. Sonuçlar, diğer test sonuçları ile hastanın klinik durumuna göre yorumlanmalıdır. 3.Her ne kadar bu ürün Hepatit B yüzey antijeni (HbsAG) ve HIV için test edilmiş ve reaktif olmadığı anlaşılmış olsa da bilinen hiçbir test insan kanından hastalık geçmeyeceğine dair garanti veremez. Bu nedenle tüm insan serumları ve hasta numuneleri ile ilgilenirken bulaşıcı madde ile ilgileniyormuşçasına hareket edilmelidir. 4.Sindirmekten ya da cilt ve mukoz zarı ile temasından kaçının. PROSEDÜR Sağlanan materyaller 85962 4 x 0,5mL Gerekli olan ancak sağlanmayan materyaller 4. HbA1c reaktif kiti 5. 0,5 ml pipet 6. İyonu alınmış su TEST PROSEDÜRÜ Aşağıdaki istisna haricinde hemolizat prosedüründe, kalibratörlere hasta numuneleri ile aynı işlemler uygulanmalıdır. Kalibratörlerin hazırlanmasında santrifüje gerek yoktur. Reaktif kiti yönlendirmelerini ve cihaz uygulama talimatlarını izleyin. KALİBRASYON NOKTASI DEĞERLERİ Listelenen değerleri inceleyin. Kalibrasyon noktası değerleri, tüm lotun temsili numunelerinin NGSP referans materyallerine karşı Cliniqa HbA1c reaktif kiti kullanılarak analiz edilmesiyle elde edilir.Doğru olmayan pipetleme, yetersiz karıştırma ve eksik kalibre edilmiş aletler yanlış sonuçlar elde edilmesine neden olabilir. REFERANSLAR 1. Trivelli, L.A., Ranney, H.M., and Lai, H.T., New Eng. J. Med. 284, 353 (1971). 2. Gonen, B. and Rubenstein, A.H., Diabetologia 15,1 (1978). 3. Gabbay, K.H., Hasty, K., Breslow, J.L., Ellison, R.C., Bunn, H.F., and Gallop, P.M., J. Clin. Endocrinol.Metab.44, 859 (1977). 4. Bates, H.M., Lab. Manag., Vol. 16 (Jan: 1978). 33070_04 10/25/2013 Revised 12/16/2013 © 2008 Cliniqa Corporation. All rights reserved. Lot Level 1307088A 2015-05 Lot Hitachi 917 Hitachi 717 Cobas Mira Level 1 1307088A 5.1 % 5.1 % 5.0 % Level 2 1307088A 8.1 % 8.3 % 8.2 % Level 3 1307088A 11.3 % 11.4 % 11.0 % Level 4 1307088A 15.4 % 15.5 % 15.1 % For in vitro diagnostic use CLINIQA CORPORATION 288 Distribution St. San Marcos, CA 92078 USA SALES AND TECHNICAL SUPPORT P: 800 728 5205 +1 760 744 1900 F: +1 760 571 5197 www.cliniqa.com See package insert for proper use FOR ORDERS AND CUSTOMER SERVICE P: 800 728 5205 +1 760 744 1900 F: +1 760 571 5197 [email protected] EC REP CEpartner4U Esdoornlaan 13 3951 DB Maarn, The Netherlands P: +31 (0)6 516 536 26 RE-ORDER INFORMATION Hemoglobin A1c Calibrator Set Catalog No. REF 85962 Made in the USA 33070_04 10/25/2013 Revised 12/16/2013 © 2008 Cliniqa Corporation. All rights reserved.
Benzer belgeler
A1C-2 - Roche
glikoz konsantrasyonu ile birlikte artar. Stabil HbA1c'ye dönüşüm, eritrositin
yaklaşık 100 ile 120 gün arasında olan ömrü ile sınırlıdır. Sonuç olarak,
HbA1c önceki 2 ila 3 ay sırasında kandaki or...