BFCU(C) (NEK 606)
Transkript
BFCU(C) (NEK 606)
OFFSHORE KABLOLARI BFCU(C) (NEK 606) HALOJENS‹Z, DÜfiÜK DUMAN YO⁄UNLUKLU, YANMAZ, ENSTRÜMANTASYON VE TELEKOM‹N‹KASYON KABLOSU HALOGEN FREE, LOW SMOKE DENSITY, FIRE RESISTANT INSTRUMENTATION AND TELECOMMUNICATION CABLE KABLO YAPISI 1- ‹LETKEN : Elektrolitik, kalayl› ve bükülü bak›r tel. IEC 60228 S›n›f 2 (S›n›f 5 iste¤e ba¤l›) 2- AYIRICI : ‹letken üstünde mika bant 3- ‹ZOLASYON : Halojensiz EPR veya halojensiz HEPR. BÜKÜM : Damarlar ikili düzende ve bükülü perler konsantrik olarak bükülür. 4- TOPRAKLAMA TEL‹ : Elektrolitik, kalayl› ve bükülü bak›r topraklama teli. 5- EKRAN : Elektrolitik bak›r kapl› Polyester bant ekran ( kapatma oran›: %100 ). 6- DOLGU : Halojensiz bileflik 7- EKRAN : Galvanizli çelik tellerden örülmüfl ekran 8- DIfi KILIF : SHF2 (SHF MUD iste¤e ba¤l›) CABLE STRUCTURE 1- CONDUCTOR : Electrolytic, stranded, tinned copper wire IEC 60228 Class 2 (Class 5 on request). 2- SEPARATOR : Mica tape over conductor 3- INSULATION : Halogen free EPR or Halogen free HEPR LAYUP : Cores laid up in pairs, pairs laid up concentrically. 4- DRAIN WIRE : Electrolytic, stranded, tinned copper drain wire 5- SCREEN : Electrolytic copper backed polyester tape screen ( 100% coverage ) 6- BEDDING : Halogen free compound. 7- SCREEN : Galvanised steel wire braided screen 8- OUTER SHEATH : SHF2 (SHF MUD on request) ÜRET‹M VE TEST STANDARTLARI / PRODUCTION AND TEST STANDARDS KONSTRÜKS‹YON / CONSTRUCTION TESTLER VE MALZEME / TESTS AND MATERIAL ALEV YÜRÜTMEME / FLAME RETARDATION YANMAZLIK / FIRE RESISTANCE HALOJEN M‹KTARI / HALOGEN CONTENT DUMAN YO⁄UNLU⁄U / SMOKE DENSITY ‹fiLETME SICAKLI⁄I / WORKING TEMPERATURE M‹N. KIVRILMA ÇAPI (SAB‹T) / MIN. BENDING RADIUS (FIXED) ANMA GER‹L‹MLER‹ / RATED VOLTAGE TEST GER‹L‹M‹ / TEST VOLTAGE 76 : NEK 606, IEC 60092/376 : IEC 60092 /350-351-359 : IEC 60332 /1, IEC 60332 / 3 Cat A : IEC 60331 : IEC 60754 / 1 - 2 : IEC 61034 / 1-2 ( DIN EN 50268/1-2) : -40°C / + 90°C : (kablo çap›)x 10 x(overall diameter) : 250 V : 1,5 kV FR 72-093 I REV. 0 REV. TAR. 01.05.2010 I Sf. 1/3 OFFSHORE CABLES BFCU(C) (NEK 606) KULLANIM ALANI APPLICATION Sinyal ve haberleflme için sabit ba¤lant› kablosu olarak kullan›l›r. Fixed installation cable for signal, and communication. ORTAM ENVIRONMENT Kuru, ›slak, ya¤l› ve tüm deniz ortamlar›nda mekanik zorlanmalar›n olabilece¤i ortamlarda kullan›labilir. Usable at all conditions in marine environment such as dry, wet or oily locations where mechanical forces may expected. GÜVENL‹K SAFETY Direkt alevle temas etmesi durumunda dahi ilgili standartta belirtilen süre boyunca çal›flmaya devam eder. Bu sayede herhangi bir yang›n durumunda önemli ekipman›n (yang›n uyar› ve söndürme sistemleri, su pompalar›, haberleflme, telsiz, kumanda sistemleri, ayd›nlatma, vb.) çal›flmaya devam etmesini sa¤lar. Ayr›ca halojensiz olmas› ve alev iletmeme özellikleri sayesinde koroziv gazlar oluflturmaz ve yang›n›n yay›lmas›n› önler. Böylece insan sa¤l›¤›n› ve de¤erli ekipman› korurken yang›n›n söndürülmesine yard›mc› olur. Düflük duman yo¤unlu¤u hem duman solumaya ba¤l› zehirlenme etkisini azalt›r hem de yang›n esnas›nda görüflün kapanmas›n› engeller. Even at direct contact with fire, it will sustain the connection for as long as stated in related standards. That provides necessary equipment (fire alarm and extinguishing systems, water pumps, communication, radio, control systems, lightning, etc.) to work uninterrupted during a fire. Due to its' halogen free and flame retardant features, it won't create corrosive gases and prevents the fire from spreading around as well. Thus it protects human life and equipment, during a fire and helps extinguishing the fire. Low smoke density reduces the risk of suffocation and keeps visibility around the fire zone. YAKIN ÜRÜNLER & NOTLAR SMILAR PRODUCTS & NOTES BFOU(C) BFOU(C) : Bak›r örgü genel ekran : Copper wire braided overall screen 180 min Aleve Dayan›kl› Fire Resistant 250 V Anma Gerilimi Rated Voltage 1.5 kV Test Gerilimi Test Voltage -40 0 +90 C Çal›flma S›cakl›¤› Working Temperature r 10x Büküm Yar›çap› Bending Radius NOM‹NAL KES‹T CROSS SECTION (mm2) 1 x 2 x 4 x 7 x 8 x 9 x 10 x 12 x 14 x 16 x 19 x 24 x 1 x 2 x 4 x 7 x 8 x 9 x 10 x 12 x 14 x 16 x 19 x 24 x 1 x 2 x 4 x 7 x 8 x 9 x 10 x 12 x 14 x 16 x 19 x 24 x 2x 2x 2x 2x 2x 2x 2x 2x 2x 2x 2x 2x 3x 3x 3x 3x 3x 3x 3x 3x 3x 3x 3x 3x 2x 2x 2x 2x 2x 2x 2x 2x 2x 2x 2x 2x 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 KABLO DIfi ÇAPI OVERALL DIAMETER (mm) YAKLAfiIK KABLO A⁄IRLI⁄I APPX. WEIGHT (kg / km) 11.6 16.9 19.3 22.5 27 27 27 29.1 30.5 32.1 34.2 38.6 12.1 18.5 21.2 24.9 30 30 30 32.8 34.4 36.7 38.6 43.1 13 19.4 22.3 26.3 31.8 31.8 31.8 34.7 36.8 38.9 40.9 46.1 200 360 520 760 940 1,020 1,170 1,260 1,620 1,820 2,220 2,330 240 410 660 1,020 1,170 1,480 1,700 1,660 2,400 2,180 3,160 3,050 260 500 750 1,160 1,380 1,460 1,710 1,900 2,110 2,520 3,050 3,650 Tablo de¤erleri EPR izolasyona göre hesaplanm›flt›r. Table values are calculated according to EPR insulation BAKIR A⁄IRLI⁄I COPPER WEIGHT (kg / km) 20 34 63 106 120 135 149 178 207 236 279 351 27 48 92 156 178 200 221 264 308 351 416 524 34 63 120 207 236 264 293 351 408 466 552 696 FR 72-093 I REV. 0 REV. TAR. 01.05.2010 I Sf. 2/3 77 OFFSHORE KABLOLARI BFCU(C) (NEK 606) NOM‹NAL KES‹T CROSS SECTION (mm2) 1 x 2 x 4 x 7 x 8 x 9 x 10 x 12 x 14 x 16 x 19 x 24 x 1 x 2 x 4 x 7 x 8 x 9 x 10 x 1 x 2 x 4 x 7 x 8 x 9 x 10 x 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 3 3 3 3 3 3 3 x x x x x x x x x x x x x x x x x x x x x x x x x x 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 KABLO DIfi ÇAPI OVERALL DIAMETER (mm) YAKLAfiIK KABLO A⁄IRLI⁄I APPX. WEIGHT (kg / km) BAKIR A⁄IRLI⁄I COPPER WEIGHT (kg / km) 14 21.3 24.6 29.2 36.3 36.3 36.3 39.1 41.1 43.4 46.2 51.6 14.4 21.1 24.4 28.9 35.9 35.9 35.9 15.1 23.3 27 32.1 40.1 40.1 40.1 280 580 950 1,430 1,670 1,840 2,200 2,520 3,330 3,570 3,990 4,670 570 1,140 1,840 2,230 2,430 2,740 2,950 780 1,670 2,690 3,170 3,510 3,940 4,200 48 92 178 308 351 394 437 524 610 696 826 104 2 53 101 197 341 389 437 485 77 149 293 509 581 653 FR 72-093 I REV. 0 REV. TAR. 01.05.2010 I Sf. 3/3 78
Benzer belgeler
BFCU (NEK 606)
durum sistemlerinde ve kritik bölgelerde, sabit ba¤lant›
kablosu olarak kullan›l›r. Elektrik da¤›t›m ve ayd›nlatma
sistemlerinde kullan›l›r.
BU(I+C) (NEK 606)
: NEK 606, IEC 60092/376
: IEC 60092 /350-351-359
: IEC 60332 /1, IEC 60332 / 3 Cat A
: IEC 60331
: IEC 60754 / 1 - 2
: IEC 61034 / 1-2 ( DIN EN 50268/1-2)
: -40°C / + 90°C
: (kablo çap›)x 10 x(ove...
Üntel Kablo Offshore Kabloları Ürün Kataloğu
Even at direct contact with fire, it will sustain the
connection for as long as stated in related standards.
That provides necessary equipment (fire alarm and
extinguishing systems, water pumps, co...