C130977 NFPA-20 COOLING LOOP PIPING DETAIL.idw
Transkript
C130977 NFPA-20 COOLING LOOP PIPING DETAIL.idw
English to Turkish DP/DQ/DR/DS/DT Engines Translation Documents C136412 CONTENTS SUBJECT Document No. English to Turkish I&O Data Translator for UL/FM DP and DQ Engine Models C136343 English to Turkish I&O Data Translator for UL/FM DR, DS and DT Engine Models C136345 English to Turkish I&O Data Translator for Non-Listed DP and DQ Engine Models C136344 English to Turkish I&O Data Translator for Non-Listed DR, DS and DT Engine Models C136346 English to Turkish Translator for C13977 C131052 NFPA 20 Cooling Loop Piping Detail C13977 English to Turkish Translator for C06918 C132543 NFPA 20 Typical Exhaust Piping Detail C06918 English to Turkish Translator for C072145 C136504 Wiring Diagram – MECAB (ETS) (April 2015 - Current) C072145 Wiring Diagram – MECAB (ETS) (Prior to April 2015) C071842 English to Turkish Translator for C131885 C136500 Battery Kit Specifications: All UL/FM NFPA-20 Engine Models C131885 English to Turkish Translator for C132026 C136501 Fuel Tank and Fuel Supply Schematic Per NFPA-20 C132026 English to Turkish Translator for C07651 C131112 Jacket Water Heater (AC Voltage) (DP6H, DQ6H, DR8H, DS0H, DT2H-UFAA20, 58, 50, 88) C07651 English to Turkish Translator for C071613 C136502 Jacket Water Heater (AC Voltage) (DT2H-UFAA60, 98, 92) C071613 Clarke Installation and Operation Datasheets DP6H-UF and DQ6H-UF Engine Models English to Turkish I & O Translator Turkish Text English Text Basic Engine Description Engine Manufacturer Ignition Type Number of Cylinders Bore and Stroke- in (mm) Displacement – in3 (L) Compression Ratio Valves per cylinder Intake Exhaust Combustion System Engine Type Fuel Management Control Firing Order Clockwise Rotation Aspiration Charge Air Cooling Type Rotation, viewed from front of engine, Clockwise Engine Crankcase Vent System Installation Drawing Weight – lb (kg) Compression (Diesel) Direct Injection In-Line, 4 Stroke Cycle Mechanical, Inline Pump Turbocharged Raw Water Cooled Standard Open Temel Motor Tanım Motor Üreticisi Yakış Tipi Kompresyon(Dizel) Silindir Adedi Delik ve Vuruş Sökme Kompresyon oranı Silindir başına piston -Giriş - Çıkış Yanma Sistemi Direkt enjeksiyon Motor Tipi Sıralı, 4 vuruş döngüsü Yakıt Yönetim Kontrolü Mekanik, Inline Pompa Ateşleme Emri (CW Rotasyonu) Emiş Turbolu Hava Soğutma Şarjı Tipi Arıtılmamış Su Rotasyon, motorun ön tarafından görünüm, Saat Yönü Standart Motor Karter Havalandırma Sistemi Açık Kurulum Çizimi Ağırlık Power Rating Nameplate Power – HP (kW) Güç Derecelendirme İsim Levhası Gücü Cooling System Engine Coolant Heat – Btw/sec (kW) Engine Radiated Heat – Btu/sec (kW) Heat Exchanger Minimum Flow 60oF (15oC) Raw H2O – gal/min (L/min) 100oF (37oC) Raw H2O – gal/min (L/min) Heat Exchanger Maximum Cooling Raw Water Inlet Pressure – psi (bar) Flow – gal/min (L/min) Typical Engine H2O Operating Temp – oF (oC)[1] Thermostat Start to Open – oF (oC) Fully Open – 0F (oC) Engine Coolant Capacity – qt (L) Coolant Pressure Cap – lb/in2 (kPa) Maximum Engine Coolant Temperature – oF (oC) Minimum Engine Coolant Temperature – oF (oC) High Coolant Temp Alarm Switch – oF (oC) Soğutma Sistemi Motor Soğutma Suyu Isısı Motorun Salçılmış Isısı Isı Değiştirici Minimum Akış Noktası Arıtılmamış Su Arıtılmamış Su Isı Değiştirici Maksimum İç Basıncı Akışı Giriş basıncı Akış Tipik Motor H2O Çalışma Sıc. [1] Termostast Açılmaya Hazır Tamamen Açılmış Motor Soğutucu Kapasitesi Motor Soğutucu Kapasitesi En Yüksek Motor Soğutma Suyu Sıcaklığı En Düşük Motor Soğutma Suyu Sıcaklığı Yüksek Soğutma Suyu Isısı Alarm Anahtarı Electric System – DC Standard System Voltage (Nominal) Battery Capacity for Ambients Above 32oF (0oC) Voltage (Nominal) Qty. Per Battery Bank SAE size per J537 CCA @ 0 F (-18oC) Reserve Capacity – Minutes Battery Cable Circuit, Max Resistance – ohm Battery Cable Minimum Size 0-120 in. Circuit Length [2] 121-160 in. Circuit Length [2] 161-200 in. Circuit Length [2] Charging Alternator Maximum Output – Amp Starter Cranking Amps, Rolling - @60oF (15oC) Standart Elektrik Sistemi-Direkt Akım Sistem Voltajı(Nominal) Yukardaki Çevreleyiciler için akümülatör Kapsitesi Voltaj(Nominal) Her akümülatör kümesi başına düşen miktar Her SAE büyüklüğü için CCA Yedek kapasite- Dakikalar Akümülatör Kablo Devresi, Azami Direnç – ohm Akümülatör Kablosu Asgari Büyüklüğü Devre Uzunluğu [2] Devre Uzunluğu [2] Devre Uzunluğu [2] Alternatör En Yüksek Çıkışı – Amper Marş Amperi, Yuvarlanma NOTE: This engine is intended for indoor installation or in a weatherproof enclosure. 1Engine H2O temperature is dependent on raw water temperature and flow. 2Positive and Negative Cables Combined Length. NOT: Bu motor ev içi kurulumu veya hava geçirmeyen kapalı bir yer için amaçlanmıştır. 1Motor H2O sıcaklığı, işlenmemiş su sıcaklığı ve akışına bağlıdır. 2Pozitif ve Negatif Kabloların Birleşik Uzunluğu C136343 Clarke Installation and Operation Datasheets DP6H-UF and DQ6H-UF Engine Models English to Turkish I & O Translator Exhaust System Exhaust Flow – ft.3/min (m3/min) Exhaust Temperature – oF (oC) Maximum Allowable Back Pressure – in H2O (kPa) Minimum Exhaust Pipe Diameter – in (mm)[3] Egzoz Sistemi Egzoz Akışı Egzoz Sıcaklığı Müsade edilebilir Azami Geri Basınç Asgari Egzoz Borusu Şeması [3] Fuel System Fuel Consumption – gal/hr (L/hr) Fuel Pressure – lb/in2 (Kpa) Minimum Line Size – Supply – in. Schedule 40 Steel Pipe Pipe Outer Diameter – in (mm) Minimum Line Size – Return – in. Schedule 40 Steel Pipe Pipe Outer Diameter – in (mm) Maximum Allowable Fuel Pump Suction Lift With clean Filter – in H2O (mH2O) Maximum Allowable Fuel Head above Fuel pump, Supply or Return – ft (m) Fuel Filter Micron Size Yakıt Sistemi Yakıt Tüketimi Yakıt Basıncı Asgari Hat Büyüklüğü – Donanım Program 40 Çelik Boru Boru Dış Çapı Asgari Hat Büyüklüğü - Dönüş Program 40 Çelik Boru Boru Dış Çapı İzin Verilen En Fazla Yakıt Pompası Emme Yüksekliği Temiz Filtreli Yakıt Pompası üzerindeki Müsade edilebilir azami Yakıt Başı, Donanım veya Dönüş Yakıt Filtresi Mikron Büyüklüğü Standard Heater System Engine Coolant Heater Wattage (Nominal) Voltage – AC, 1 Phase Part Number Standart Isıtma Sistemi Motor Soğutma Suyu Isısı Wat (Nominal) Voltaj- Alternatif Akım, 1P Parça Numarası Air System Combustion Air Flow – ft.3min (m3/min) Air Cleaner Standard Part Number Type Indoor Service Only, with Shield Cleaning method Washable Air Intake Restriction Maximum Limit Dirty Air Cleaner – in H2O (kPa) Clean Air Cleaner – in H2O (kPa) Maximum Allowable Temperature (Air to Engine Inlet) – oF (oC)[4] Optional Optional Canister Single-Stage Disposable Hava Sistemi Yanma Havası Akışı Hava Temizleyici Standart Isteğe bağlı Parça Numarası Tip Yalnız Dahili Hizmetler, kutulu, Koruma tek aşamalı Temizleme Yöntemi Yıkanabilir Tek kullanımlık Hava Giriş Sınırlama Azami Sınırı Kirli Hava Temizleyici Temiz Hava Temizleyici Müsade edilir Azami Sıcaklık (Motor Girişine giden Hava) [4] Lubrication System Oil Pressure – normal – lb/in2 (kPa) Low Oil Pressure Alarm Switch – lb/in2 (kPa) In Pan Oil Temperature – oF (oC) Total Oil Capacity with Filter – qt (L) Yağlama Sistemi Yağ Basıncı – normal Düşük Yağ Basıncı Alarm Anahtarı Yağlama Elek Sıcaklığı İçinde Filtreli Toplam Yağ Kapasitesi Lube Oil Heater Wattage (Nominal) Voltage Part Number Yağlama Yağı Isıtıcı Wat (Nominal) Voltaj Parça Numarası Optional Isteğe bağlı Performance BMEP – lb/in2 (kPa) Piston Speed – ft/min (m/min) Mechanical Noise – dB(A) @ 1m Power Curve Performans BMEP Piston Hızı Mekanik Gürültü Güç Eğrisi 3 Based on Nominal System. Back pressure flow analysis must be done to assure maximum allowable back pressure is not exceeded. (Note: minimum exhaust Pipe diameter is based on: 15 feet of pipe, one 90oelbow, and a silencer pressure drop no greater than one half of the maximum allowable back pressure.) 4Review for horsepower derate if ambient air entering engine exceeds 77oF (25oC). [ ] indicates component reference part number. 3 isteğe bağlı Nominal Sistem temelinde. İzin verilen en yüksek geri basıncın aşılmadığından emin olmak için, geri basınç akışı analizi yapılmalıdır (Not: en az egzoz borusu çapı şunu temel alır: 4,5 metre boru, 90° dirsekte ve izin verilen en yüksek geri basıncın yarısından daha büyük olmayan, susturucu basınç düşüşü.. 4Motora giren ortam havası 25°C’yi (77°F) aşarsa, beygirgücü düşüşünü gözden geçirin. [] Bileşeni gösterir parça numarasını referans. C136343 Clarke Installation and Operation Datasheets for DR8H-UF, DS0H/R-UF and DT2H-UF Engine Models English to Turkish I & O Data Translator English Text Basic Engine Description Engine Manufacturer Ignition Type Number of Cylinders Bore and Stroke- in (mm) Displacement – in3 (L) Compression Ratio Valves per cylinder Intake Exhaust Combustion System Engine Type Fuel Management Control Firing Order Clockwise Rotation Aspiration Charge Air Cooling Type Rotation, viewed from front of engine, Clockwise Engine Crankcase Vent System Installation Drawing Weight – lb (kg) Compression (Diesel) Direct Injection Vee , 4 Stroke Cycle Mechanical, Inline Pump Twin Turbocharged Raw Water Cooled Standard Closed Turkish Text Temel Motor Tanım Motor Üreticisi Yakış Tipi Kompresyon(Dizel) Silindir Adedi Delik ve Vuruş Sökme Kompresyon oranı Silindir başına piston -Giriş - Çıkış Yanma Sistemi Direkt enjeksiyon Motor Tipi Vee, 4 zamanlı Döngüsü Yakıt Yönetim Kontrolü Mekanik, Inline Pompa Ateşleme Emri (CW Rotasyonu) Emiş İkiz Turbo Hava Soğutma Şarjı Tipi Arıtılmamış Su Rotasyon, motorun ön tarafından görünüm, Saat Yönü Standart Motor Karter Havalandırma Sistemi Kapalı Kurulum Çizimi Ağırlık Power Rating Nameplate Power – HP (kW) Güç Derecelendirme İsim Levhası Gücü Cooling System – Heat Exchanger Engine Coolant Heat – Btw/sec (kW) Engine Radiated Heat – Btu/sec (kW) Heat Exchanger Minimum Flow 60oF (15oC) Raw H2O – gal/min (L/min) 100oF (37oC) Raw H2O – gal/min (L/min) Heat Exchanger Maximum Cooling Raw Water Inlet Pressure – psi (bar) Flow – gal/min (L/min) Typical Engine H2O Operating Temp – oF (oC)[1] Thermostat Start to Open – oF (oC) Fully Open – 0F (oC) Engine Coolant Capacity – qt (L) Coolant Pressure Cap – lb/in2 (kPa) Maximum Engine Coolant Temperature – oF (oC) Minimum Engine Coolant Temperature – oF (oC) High Coolant Temp Alarm Switch – oF (oC) Soğutma Sistemi - Eşanjör Motor Soğutma Suyu Isısı Motorun Salçılmış Isısı Isı Değiştirici Minimum Akış Noktası Arıtılmamış Su Arıtılmamış Su Isı Değiştirici Maksimum İç Basıncı Akışı Giriş basıncı Akış Tipik Motor H2O Çalışma Sıc. [1] Termostast Açılmaya Hazır Tamamen Açılmış Motor Soğutucu Kapasitesi Motor Soğutucu Kapasitesi En Yüksek Motor Soğutma Suyu Sıcaklığı En Düşük Motor Soğutma Suyu Sıcaklığı Yüksek Soğutma Suyu Isısı Alarm Anahtarı Cooling System – Radiator Engine Coolant Heat – Btw/sec (kW) Engine Radiated Heat – Btu/sec (kW) Radiator Minimum Ventilation Flow –ft.3/min (m3/min) Typical Engine H2O Operating Temp – oF (oC)[1] Thermostat Start to Open – oF (oC) Fully Open – 0F (oC) Engine Coolant Capacity – qt (L) Coolant Pressure Cap – lb/in2 (kPa) Maximum Engine Coolant Temperature – oF (oC) Minimum Engine Coolant Temperature – oF (oC) High Coolant Temp Alarm Switch – oF (oC) Soğutma Sistemi – radyatör Motor Soğutma Suyu Isısı Motorun Salçılmış Isısı Radyatör Asgari Havalandırma Akışı Tipik Motor H2O Çalışma Sıc. [1] Termostast Açılmaya Hazır Tamamen Açılmış Motor Soğutucu Kapasitesi Motor Soğutucu Kapasitesi En Yüksek Motor Soğutma Suyu Sıcaklığı En Düşük Motor Soğutma Suyu Sıcaklığı Yüksek Soğutma Suyu Isısı Alarm Anahtarı Electric System – DC Standard System Voltage (Nominal) Battery Capacity for Ambients Above 32oF (0oC) Voltage (Nominal) Qty. Per Battery Bank SAE size per J537 CCA @ 0 F (-18oC) Reserve Capacity – Minutes Battery Cable Circuit, Max Resistance – ohm Standart Elektrik Sistemi-Direkt Akım Sistem Voltajı(Nominal) Yukardaki Çevreleyiciler için akümülatör Kapsitesi Voltaj(Nominal) Her akümülatör kümesi başına düşen miktar Her SAE büyüklüğü için CCA Yedek kapasite- Dakikalar Akümülatör Kablo Devresi, Azami Direnç – ohm C136345 Clarke Installation and Operation Datasheets for DR8H-UF, DS0H/R-UF and DT2H-UF Engine Models English to Turkish I & O Data Translator Battery Cable Minimum Size 0-120 in. Circuit Length [2] 121-160 in. Circuit Length [2] 161-200 in. Circuit Length [2] Charging Alternator Maximum Output – Amp Starter Cranking Amps, Rolling - @60oF (15oC) Akümülatör Kablosu Asgari Büyüklüğü Devre Uzunluğu [2] Devre Uzunluğu [2] Devre Uzunluğu [2] Alternatör En Yüksek Çıkışı – Amper Marş Amperi, Yuvarlanma NOTE: This engine is intended for indoor installation or in a weatherproof enclosure. 1Engine H2O temperature is dependent on raw water temperature and flow. 2Positive and Negative Cables Combined Length. NOT: Bu motor ev içi kurulumu veya hava geçirmeyen kapalı bir yer için amaçlanmıştır. 1Motor H2O sıcaklığı, işlenmemiş su sıcaklığı ve akışına bağlıdır. 2Pozitif ve Negatif Kabloların Birleşik Uzunluğu Exhaust System (dual exhaust outlets) Exhaust Flow – ft.3/min (m3/min) [ 3] Exhaust Temperature – oF (oC) Maximum Allowable Back Pressure – in H2O (kPa) Minimum Exhaust Pipe Diameter – in (mm)[4] (quantity 2) Egzoz Sistemi (çift egzoz çıkışları) Egzoz Akışı [ 3] Egzoz Sıcaklığı Müsade edilebilir Azami Geri Basınç Asgari Egzoz Borusu Şeması [4] (miktar 2) Fuel System Fuel Consumption – gal/hr (L/hr) Fuel Pressure – lb/in2 (Kpa) Minimum Line Size – Supply – in. Schedule 40 Steel Pipe Pipe Outer Diameter – in (mm) Minimum Line Size – Return – in. Schedule 40 Steel Pipe Pipe Outer Diameter – in (mm) Maximum Allowable Fuel Pump Suction Lift With clean Filter – in H2O (mH2O) Maximum Allowable Fuel Head above Fuel pump, Supply or Return – ft (m) Fuel Filter Micron Size Yakıt Sistemi Yakıt Tüketimi Yakıt Basıncı Asgari Hat Büyüklüğü – Donanım Program 40 Çelik Boru Boru Dış Çapı Asgari Hat Büyüklüğü - Dönüş Program 40 Çelik Boru Boru Dış Çapı İzin Verilen En Fazla Yakıt Pompası Emme Yüksekliği Temiz Filtreli Yakıt Pompası üzerindeki Müsade edilebilir azami Yakıt Başı, Donanım veya Dönüş Yakıt Filtresi Mikron Büyüklüğü Heater System Engine Coolant Heater* Wattage (Nominal) Voltage – AC, 1 Phase Part Number Standard Optional Standart Isıtma Sistemi Motor Soğutma Suyu Isısı* Wat (Nominal) Voltaj- Alternatif Akım, 1P Parça Numarası Isteğe bağlı Air System Combustion Air Flow – ft.3min (m3/min) Optional Air Cleaner Standard Part Number Quantity Type Indoor Service Only Canister with Shield Single-Stage Cleaning method Washable Disposable Air Intake Restriction Maximum Limit Dirty Air Cleaner – in H2O (kPa) Clean Air Cleaner – in H2O (kPa) Maximum Allowable Temperature (Air to Engine Inlet) – oF (oC)[5] Hava Sistemi Yanma Havası Akışı Isteğe bağlı Hava Temizleyici Standart Parça Numarası Tip Yalnız Dahili Hizmetler, kutulu, Koruma tek aşamalı Temizleme Yöntemi Yıkanabilir Tek kullanımlık Hava Giriş Sınırlama Azami Sınırı Kirli Hava Temizleyici Temiz Hava Temizleyici Müsade edilir Azami Sıcaklık (Motor Girişine giden Hava) [5] Lubrication System Oil Pressure – normal – lb/in2 (kPa) Low Oil Pressure Alarm Switch – lb/in2 (kPa) In Pan Oil Temperature – oF (oC) Total Oil Capacity with Filter – qt (L) Yağlama Sistemi Yağ Basıncı – normal Düşük Yağ Basıncı Alarm Anahtarı Yağlama Elek Sıcaklığı İçinde Filtreli Toplam Yağ Kapasitesi Lube Oil Heater Wattage (Nominal) Voltage Part Number Yağlama Yağı Isıtıcı Wat (Nominal) Voltaj Parça Numarası Optional Performance BMEP – lb/in2 (kPa) Piston Speed – ft/min (m/min) Mechanical Noise – dB(A) @ 1m Power Curve isteğe bağlı Performans BMEP Piston Hızı Mekanik Gürültü Güç Eğrisi C136345 Clarke Installation and Operation Datasheets for DR8H-UF, DS0H/R-UF and DT2H-UF Engine Models English to Turkish I & O Data Translator 3 3 Engine has dual exhaust outlets. Combined total exhaust flow from both outlets is given. 4Based on Nominal System. Back pressure flow analysis must be done to assure maximum allowable back pressure is not exceeded. (Note: minimum exhaust Pipe diameter is based on: 15 feet of pipe, one 90oelbow, and a silencer pressure drop no greater than one half of the maximum allowable back pressure.) 5Review for horsepower derate if ambient air entering engine exceeds 77oF (25oC). [ ] indicates component reference part number. Motor çift egzoz çıkışları vardır. Kombine toplam egzoz akışı Her iki çıkışları verilir. 4Nominal Sistem temelinde. İzin verilen en yüksek geri basıncın aşılmadığından emin olmak için, geri basınç akışı analizi yapılmalıdır (Not: en az egzoz borusu çapı şunu temel alır: 4,5 metre boru, 90° dirsekte ve izin verilen en yüksek geri basıncın yarısından daha büyük olmayan, susturucu basınç düşüşü.. 5Motora giren ortam havası 25°C’yi (77°F) aşarsa, beygirgücü düşüşünü gözden geçirin. [] Bileşeni gösterir parça numarasını referans. *For DT2H-UFAA60, UFKA60, UFAA98, UFKA98, UFAA92 and UFKA92 – These models require Two (2) Engine Coolant Heaters. * For DT2H-UFAA60, UFKA60, UFAA98, UFKA98, UFAA92 and UFKA92 için - Bu modeller gerektirir İki (2) Motor Soğutucu Isıtıcılar. C136345 Clarke Installation and Operation Datasheets DP6H-NL and DQ6H-NL Engine Models English to Turkish I & O Translator Turkish Text English Text Basic Engine Description Engine Manufacturer Ignition Type Number of Cylinders Bore and Stroke- in (mm) Displacement – in3 (L) Compression Ratio Valves per cylinder Intake Exhaust Combustion System Engine Type Fuel Management Control Firing Order Clockwise Rotation Aspiration Charge Air Cooling Type Rotation, viewed from front of engine, Clockwise Engine Crankcase Vent System Installation Drawing Weight – lb (kg) Compression (Diesel) Direct Injection In-Line, 4 Stroke Cycle Mechanical, Inline Pump Turbocharged Raw Water Cooled Standard Open Temel Motor Tanım Motor Üreticisi Yakış Tipi Kompresyon(Dizel) Silindir Adedi Delik ve Vuruş Sökme Kompresyon oranı Silindir başına piston -Giriş - Çıkış Yanma Sistemi Direkt enjeksiyon Motor Tipi Sıralı, 4 vuruş döngüsü Yakıt Yönetim Kontrolü Mekanik, Inline Pompa Ateşleme Emri (CW Rotasyonu) Emiş Turbolu Hava Soğutma Şarjı Tipi Arıtılmamış Su Rotasyon, motorun ön tarafından görünüm, Saat Yönü Standart Motor Karter Havalandırma Sistemi Açık Kurulum Çizimi Ağırlık Power Rating Gross Power – kW (HP) [1] Güç Derecelendirme Brüt Güç[1] Cooling System – Heat Exchanger Engine Coolant Heat – kW (Btw/sec) Engine Radiated Heat – kW (Btu/sec) Heat Exchanger Minimum Flow 15oC (60o F) Raw H2O – L/min (gal/min) 37oC (100o F) Raw H2O – L/min (gal/min) Heat Exchanger Maximum Cooling Raw Water Inlet Pressure – bar (psi) Flow – L/min (gal/min) Typical Engine H2O Operating Temp – oC (oF)[2] Thermostat Start to Open – oC (oF) Fully Open – oC (oF) Engine Coolant Capacity – L (qt) Coolant Pressure Cap – kPa (lb/in2) Maximum Engine Coolant Temperature – oC (oF) Minimum Engine Coolant Temperature – oC (oF) High Coolant Temp Alarm Switch – oC (oF) Soğutma Sistemi - Eşanjör Motor Soğutma Suyu Isısı Motorun Salçılmış Isısı Isı Değiştirici Minimum Akış Noktası Arıtılmamış Su Arıtılmamış Su Isı Değiştirici Maksimum İç Basıncı Akışı Giriş basıncı Akış Tipik Motor H2O Çalışma Sıc. [2] Termostast Açılmaya Hazır Tamamen Açılmış Motor Soğutucu Kapasitesi Motor Soğutucu Kapasitesi En Yüksek Motor Soğutma Suyu Sıcaklığı En Düşük Motor Soğutma Suyu Sıcaklığı Yüksek Soğutma Suyu Isısı Alarm Anahtarı Electric System – DC Standard System Voltage (Nominal) Battery Capacity for Ambients Above 0oC (32oF) Voltage (Nominal) Qty. Per Battery Bank SAE size per J537 CCA @ -18oC (0 F) Reserve Capacity – Minutes Battery Cable Circuit, Max Resistance – ohm Battery Cable Minimum Size 0-3.1 m Circuit Length [3] 3.1m-4.1m Circuit Length [3] 4.1m-5.1m Circuit Length [3] Charging Alternator Maximum Output – Amp Starter Cranking Amps, Rolling - @15 oC (60oF) Standart Elektrik Sistemi-Direkt Akım Sistem Voltajı(Nominal) Yukardaki Çevreleyiciler için akümülatör Kapsitesi Voltaj(Nominal) Her akümülatör kümesi başına düşen miktar Her SAE büyüklüğü için CCA Yedek kapasite- Dakikalar Akümülatör Kablo Devresi, Azami Direnç – ohm Akümülatör Kablosu Asgari Büyüklüğü Devre Uzunluğu [3] Devre Uzunluğu [3] Devre Uzunluğu [3] Alternatör En Yüksek Çıkışı – Amper Marş Amperi, Yuvarlanma NOTE: This engine is intended for indoor installation or in a weatherproof enclosure. 1Reduce published Gross kW’s by 10% to determine maximum pump load. 2Engine H2O temperature is dependent on raw water temperature and flow. 3Positive and Negative Cables Combined Length. NOT: Bu motor ev içi kurulumu veya hava geçirmeyen kapalı bir yer için amaçlanmıştır. 1Maksimum pompa yükünü belirlemek için% 10 tarafından yayınlanan Brüt kW en azaltın. 2 Motor H2O sıcaklığı, işlenmemiş su sıcaklığı ve akışına bağlıdır. 3 Pozitif ve Negatif Kabloların Birleşik Uzunluğu. C136344 Clarke Installation and Operation Datasheets DP6H-NL and DQ6H-NL Engine Models English to Turkish I & O Translator Exhaust System Exhaust Flow – ft.3/min (m3/min) Exhaust Temperature – oF (oC) Maximum Allowable Back Pressure – in H2O (kPa) Minimum Exhaust Pipe Diameter – in (mm)[4] Egzoz Sistemi Egzoz Akışı Egzoz Sıcaklığı Müsade edilebilir Azami Geri Basınç Asgari Egzoz Borusu Şeması [4] Fuel System Fuel Consumption – L/hr (gal/hr) Fuel Pressure – Kpa (lb/in2 ) Minimum Line Size – Supply – in. Schedule 40 Steel Pipe Pipe Outer Diameter – mm (in) Minimum Line Size – Return – in. Schedule 40 Steel Pipe Pipe Outer Diameter – mm (in) Maximum Allowable Fuel Pump Suction Lift With clean Filter – mH2O (in H2O) Maximum Allowable Fuel Head above Fuel pump, Supply or Return – m (ft) Fuel Filter Micron Size Yakıt Sistemi Yakıt Tüketimi Yakıt Basıncı Asgari Hat Büyüklüğü – Donanım Program 40 Çelik Boru Boru Dış Çapı Asgari Hat Büyüklüğü - Dönüş Program 40 Çelik Boru Boru Dış Çapı İzin Verilen En Fazla Yakıt Pompası Emme Yüksekliği Temiz Filtreli Yakıt Pompası üzerindeki Müsade edilebilir azami Yakıt Başı, Donanım veya Dönüş Yakıt Filtresi Mikron Büyüklüğü Standard Heater System Engine Coolant Heater Wattage (Nominal) Voltage – AC, 1 Phase Part Number Standart Isıtma Sistemi Motor Soğutma Suyu Isısı Wat (Nominal) Voltaj- Alternatif Akım, 1P Parça Numarası Air System Combustion Air Flow – m3/min (ft.3min) Air Cleaner Standard Part Number Type Indoor Service Only, with Shield Cleaning method Washable Air Intake Restriction Maximum Limit Dirty Air Cleaner – kPa (in H2O) Clean Air Cleaner – kPa (in H2O) Maximum Allowable Temperature (Air to Engine Inlet) – oC (oF)[5] Optional Optional Canister Single-Stage Disposable Hava Sistemi Yanma Havası Akışı Hava Temizleyici Standart Isteğe bağlı Parça Numarası Tip Yalnız Dahili Hizmetler, kutulu, Koruma tek aşamalı Temizleme Yöntemi Yıkanabilir Tek kullanımlık Hava Giriş Sınırlama Azami Sınırı Kirli Hava Temizleyici Temiz Hava Temizleyici Müsade edilir Azami Sıcaklık (Motor Girişine giden Hava) [5] Lubrication System Oil Pressure – normal – kPa (lb/in2 ) Low Oil Pressure Alarm Switch – kPa (lb/in2 ) In Pan Oil Temperature – oC (oF) Total Oil Capacity with Filter – L (qt) Yağlama Sistemi Yağ Basıncı – normal Düşük Yağ Basıncı Alarm Anahtarı Yağlama Elek Sıcaklığı İçinde Filtreli Toplam Yağ Kapasitesi Lube Oil Heater Wattage (Nominal) Voltage Part Number Yağlama Yağı Isıtıcı Wat (Nominal) Voltaj Parça Numarası Optional Isteğe bağlı Performance BMEP – kPa (lb/in2 ) Piston Speed – m/min (ft/min) Mechanical Noise – dB(A) @ 1m Power Curve Performans BMEP Piston Hızı Mekanik Gürültü Güç Eğrisi 4 Based on Nominal System. Back pressure flow analysis must be done to assure maximum allowable back pressure is not exceeded. (Note: minimum exhaust Pipe diameter is based on: 15 feet of pipe, one 90oelbow, and a silencer pressure drop no greater than one half of the maximum allowable back pressure.) 5Review for horsepower derate if ambient air entering engine exceeds 77oF (25oC). [ ] indicates component reference part number. 4 isteğe bağlı Nominal Sistem temelinde. İzin verilen en yüksek geri basıncın aşılmadığından emin olmak için, geri basınç akışı analizi yapılmalıdır (Not: en az egzoz borusu çapı şunu temel alır: 4,5 metre boru, 90° dirsekte ve izin verilen en yüksek geri basıncın yarısından daha büyük olmayan, susturucu basınç düşüşü.. 5 Motora giren ortam havası 25°C’yi (77°F) aşarsa, beygirgücü düşüşünü gözden geçirin. [] Bileşeni gösterir parça numarasını referans. C136344 Clarke Installation and Operation Datasheets for DR8H-NL, DS0H/R-NL and DT2H-NL Engine Models English to Turkish I & O Data Translator English Text Basic Engine Description Engine Manufacturer Ignition Type Number of Cylinders Bore and Stroke- in (mm) Displacement – in3 (L) Compression Ratio Valves per cylinder Intake Exhaust Combustion System Engine Type Fuel Management Control Firing Order Clockwise Rotation Aspiration Charge Air Cooling Type Rotation, viewed from front of engine, Clockwise Engine Crankcase Vent System Installation Drawing Weight – lb (kg) Compression (Diesel) Direct Injection Vee , 4 Stroke Cycle Mechanical, Inline Pump Twin Turbocharged Raw Water Cooled Standard Closed Turkish Text Temel Motor Tanım Motor Üreticisi Yakış Tipi Kompresyon(Dizel) Silindir Adedi Delik ve Vuruş Sökme Kompresyon oranı Silindir başına piston -Giriş - Çıkış Yanma Sistemi Direkt enjeksiyon Motor Tipi Vee, 4 zamanlı Döngüsü Yakıt Yönetim Kontrolü Mekanik, Inline Pompa Ateşleme Emri (CW Rotasyonu) Emiş İkiz Turbo Hava Soğutma Şarjı Tipi Arıtılmamış Su Rotasyon, motorun ön tarafından görünüm, Saat Yönü Standart Motor Karter Havalandırma Sistemi Kapalı Kurulum Çizimi Ağırlık Power Rating Gross Power – kW (HP) [1] Güç Derecelendirme Brüt Güç[1] Cooling System – Heat Exchanger Engine Coolant Heat – kW (Btw/sec) Engine Radiated Heat – kW (Btu/sec) Heat Exchanger Minimum Flow 15oC (60o F) Raw H2O – L/min (gal/min) 37oC (100o F) Raw H2O – L/min (gal/min) Heat Exchanger Maximum Cooling Raw Water Inlet Pressure – bar (psi) Flow – L/min (gal/min) Typical Engine H2O Operating Temp – oC (oF)[2] Thermostat Start to Open – oC (oF) Fully Open – oC (oF) Engine Coolant Capacity – L (qt) Coolant Pressure Cap – kPa (lb/in2) Maximum Engine Coolant Temperature – oC (oF) Minimum Engine Coolant Temperature – oC (oF) High Coolant Temp Alarm Switch – oC (oF) Soğutma Sistemi - Eşanjör Motor Soğutma Suyu Isısı Motorun Salçılmış Isısı Isı Değiştirici Minimum Akış Noktası Arıtılmamış Su Arıtılmamış Su Isı Değiştirici Maksimum İç Basıncı Akışı Giriş basıncı Akış Tipik Motor H2O Çalışma Sıc. [2] Termostast Açılmaya Hazır Tamamen Açılmış Motor Soğutucu Kapasitesi Motor Soğutucu Kapasitesi En Yüksek Motor Soğutma Suyu Sıcaklığı En Düşük Motor Soğutma Suyu Sıcaklığı Yüksek Soğutma Suyu Isısı Alarm Anahtarı Cooling System – Radiator Engine Coolant Heat – kW (Btw/sec) Engine Radiated Heat – kW (Btw/sec) Radiator Minimum Ventilation Flow -m3/min (ft.3/min) Typical Engine H2O Operating Temp – oC (oF)[2] Thermostat Start to Open – oC (oF) Fully Open – oC (oF) Engine Coolant Capacity – L (qt) Coolant Pressure Cap – kPa (lb/in2 ) Maximum Engine Coolant Temperature – oC (oF) Minimum Engine Coolant Temperature – oC (oF) High Coolant Temp Alarm Switch – oC (oF) Soğutma Sistemi – radyatör Motor Soğutma Suyu Isısı Motorun Salçılmış Isısı Radyatör Asgari Havalandırma Akışı Tipik Motor H2O Çalışma Sıc. [2] Termostast Açılmaya Hazır Tamamen Açılmış Motor Soğutucu Kapasitesi Motor Soğutucu Kapasitesi En Yüksek Motor Soğutma Suyu Sıcaklığı En Düşük Motor Soğutma Suyu Sıcaklığı Yüksek Soğutma Suyu Isısı Alarm Anahtarı Electric System – DC Standard System Voltage (Nominal) Battery Capacity for Ambients Above 0oC (32oF) Voltage (Nominal) Qty. Per Battery Bank SAE size per J537 CCA @ -18oC (0 F) Reserve Capacity – Minutes Battery Cable Circuit, Max Resistance – ohm Standart Elektrik Sistemi-Direkt Akım Sistem Voltajı(Nominal) Yukardaki Çevreleyiciler için akümülatör Kapsitesi Voltaj(Nominal) Her akümülatör kümesi başına düşen miktar Her SAE büyüklüğü için CCA Yedek kapasite- Dakikalar Akümülatör Kablo Devresi, Azami Direnç – ohm C136346 Clarke Installation and Operation Datasheets for DR8H-NL, DS0H/R-NL and DT2H-NL Engine Models English to Turkish I & O Data Translator Akümülatör Kablosu Asgari Büyüklüğü Devre Uzunluğu [3] Devre Uzunluğu [3] Devre Uzunluğu [3] Alternatör En Yüksek Çıkışı – Amper Marş Amperi, Yuvarlanma Battery Cable Minimum Size 0-3.1 m Circuit Length [3] 3.1m-4.1m Circuit Length [3] 4.1m-5.1m Circuit Length [3] Charging Alternator Maximum Output – Amp Starter Cranking Amps, Rolling - @15 oC (60oF) NOTE: This engine is intended for indoor installation or in a weatherproof enclosure. 1Reduce published Gross kW’s by 10% to determine maximum pump load. 2Engine H2O temperature is dependent on raw water temperature and flow. 3Positive and Negative Cables Combined Length. NOT: Bu motor ev içi kurulumu veya hava geçirmeyen kapalı bir yer için amaçlanmıştır. 1Maksimum pompa yükünü belirlemek için% 10 tarafından yayınlanan Brüt kW en azaltın. 2Motor H2O sıcaklığı, işlenmemiş su sıcaklığı ve akışına bağlıdır. 3Pozitif ve Negatif Kabloların Birleşik Uzunluğu Exhaust System (dual exhaust outlets) Exhaust Flow – m3/min (ft.3/min) [4] Exhaust Temperature – oC (o F) Maximum Allowable Back Pressure – kPa (in H2O) Minimum Exhaust Pipe Diameter – mm (in)[5] (quantity 2) Egzoz Sistemi (çift egzoz çıkışları) Egzoz Akışı [ 4] Egzoz Sıcaklığı Müsade edilebilir Azami Geri Basınç Asgari Egzoz Borusu Şeması [5] (miktar 2) Fuel System Fuel Consumption – L/hr (gal/hr) Fuel Pressure – Kpa (lb/in2 ) Minimum Line Size – Supply – in. Schedule 40 Steel Pipe Pipe Outer Diameter – mm (in) Minimum Line Size – Return – in. Schedule 40 Steel Pipe Pipe Outer Diameter – mm (in) Maximum Allowable Fuel Pump Suction Lift With clean Filter – mH2O (in H2O) Maximum Allowable Fuel Head above Fuel pump, Supply or Return – m (ft) Fuel Filter Micron Size Yakıt Sistemi Yakıt Tüketimi Yakıt Basıncı Asgari Hat Büyüklüğü – Donanım Program 40 Çelik Boru Boru Dış Çapı Asgari Hat Büyüklüğü - Dönüş Program 40 Çelik Boru Boru Dış Çapı İzin Verilen En Fazla Yakıt Pompası Emme Yüksekliği Temiz Filtreli Yakıt Pompası üzerindeki Müsade edilebilir azami Yakıt Başı, Donanım veya Dönüş Yakıt Filtresi Mikron Büyüklüğü Heater System Engine Coolant Heater* Wattage (Nominal) Voltage – AC, 1 Phase Part Number Standard Optional Standart Isıtma Sistemi Motor Soğutma Suyu Isısı* Wat (Nominal) Voltaj- Alternatif Akım, 1P Parça Numarası Isteğe bağlı Air System Combustion Air Flow – m3/min (ft.3min) Optional Air Cleaner Standard Part Number Quantity Quantity Type Indoor Service Only Canister with Shield Single-Stage Cleaning method Washable Disposable Air Intake Restriction Maximum Limit Dirty Air Cleaner – kPa (in H2O) Clean Air Cleaner – kPa (in H2O) Maximum Allowable Temperature (Air to Engine Inlet) – oC (oF)[6] Hava Sistemi Yanma Havası Akışı Hava Temizleyici Standart Isteğe bağlı Parça Numarası Tip Yalnız Dahili Hizmetler, kutulu, Koruma tek aşamalı Temizleme Yöntemi Yıkanabilir Tek kullanımlık Hava Giriş Sınırlama Azami Sınırı Kirli Hava Temizleyici Temiz Hava Temizleyici Müsade edilir Azami Sıcaklık (Motor Girişine giden Hava) [6] Lubrication System Oil Pressure – normal – kPa (lb/in2 ) Low Oil Pressure Alarm Switch – kPa (lb/in2 ) In Pan Oil Temperature – oC (oF) Total Oil Capacity with Filter – L (qt) Yağlama Sistemi Yağ Basıncı – normal Düşük Yağ Basıncı Alarm Anahtarı Yağlama Elek Sıcaklığı İçinde Filtreli Toplam Yağ Kapasitesi Lube Oil Heater Wattage (Nominal) Voltage Part Number Yağlama Yağı Isıtıcı Wat (Nominal) Voltaj Parça Numarası Optional Performance BMEP – kPa (lb/in2 ) Piston Speed – m/min (ft/min) Mechanical Noise – dB(A) @ 1m Power Curve isteğe bağlı Performans BMEP Piston Hızı Mekanik Gürültü Güç Eğrisi C136346 Clarke Installation and Operation Datasheets for DR8H-NL, DS0H/R-NL and DT2H-NL Engine Models English to Turkish I & O Data Translator 4 4 Engine has dual exhaust outlets. Combined total exhaust flow from both outlets is given. 5Based on Nominal System. Back pressure flow analysis must be done to assure maximum allowable back pressure is not exceeded. (Note: minimum exhaust Pipe diameter is based on: 15 feet of pipe, one 90oelbow, and a silencer pressure drop no greater than one half of the maximum allowable back pressure.) 6Review for horsepower derate if ambient air entering engine exceeds 77oF (25oC). [ ] indicates component reference part number. Motor çift egzoz çıkışları vardır. Kombine toplam egzoz akışı Her iki çıkışları verilir. 5Nominal Sistem temelinde. İzin verilen en yüksek geri basıncın aşılmadığından emin olmak için, geri basınç akışı analizi yapılmalıdır (Not: en az egzoz borusu çapı şunu temel alır: 4,5 metre boru, 90° dirsekte ve izin verilen en yüksek geri basıncın yarısından daha büyük olmayan, susturucu basınç düşüşü.. 6Motora giren ortam havası 25°C’yi (77°F) aşarsa, beygirgücü düşüşünü gözden geçirin. [] Bileşeni gösterir parça numarasını referans. *For DT2H-NLKA60, NLKA98 and NLKA92 – These models require Two (2) Engine Coolant Heaters. * DT2H-NLKA60, NLKA98 and NLKA92 için - Bu modeller gerektirir İki (2) Motor Soğutucu Isıtıcılar. C136346 Clarke Cooling Loop Piping Detail C13977 English to English to Turkish Translation English Text Turkish Text NFPA-20 Cooling Loop Piping Detail NFPA-20 Soğutma cihazı boru detayı NOTES: NOTLER: 1) PIPING ARRANGEMENT PER NFPA-20 1) NFPA 20’ YE GÖRE BORU AYARLAMASI 2) PIPING BY OTHERS 2) DİĞERLERİ VASITASIYLA BORU TAKMA 3) DISCHARGE PIPING FROM HEAT EXCHANGER OUTLET IS ONE PIPE SIZE LARGER THAN THE INLET PIPING TO THE HEAT EXCHANGER. 3) ISI DEĞİŞTİRİCİDEN ÇIKAN BOŞALTMA BORUSU COOLING LOOP WATER – DIRECTION OF FLOW SOĞUTUCU CİHAZI SUYU-AKIŞ İSTİKAMETİ PUMP DISCHARGE CONNECTION POMPA BOŞALTMA BAĞLANTISI COOLING LOOP (BY CLARKE) SOĞUTMA CİHAZI (CLARK TARAFINDAN) ENGINE COOLING WATER PIPED TO DRAIN MOTOR SOĞUTMA SUYU DRENAJ BORUSU ENGINE MOTOR GUARD KORUMA COUPLING BİRLEŞTİRME PUMP POMPA INLET GİRİŞ ENGINE HEAT EXCHANGER MOTOR ISI DEĞİŞTİRİCİSİ OUTLET ÇIKIŞ VIEW A-A A-A GÖRÜNTÜSÜ BY-PASS LINE BY PASS HATTI UNION BİRLEŞME PRESSURE REGULATOR TAZYİK AYARLAYICI GAUGE AYAR BALL VALVE BİLYELİ VANA WYE STRAINER SÜZGEÇ 12V OR 24V SOLENOID VALVE 12 V VEYA 24 V SOLENOİD VANASI STANDARD COOLING LOOP STANDARD SOĞUTMA CİHAZI ISI DEĞİŞTİRİCİNİN GİRİŞ BORUSUNDAN BİR BOY DAHA GENİŞTİR. C131052 revA A B C D 2 COOLING LOOP (BY CLARKE) 3 4 COOLING LOOP WATER - DIRECTION OF FLOW DISCHARGE PIPING FROM HEAT EXCHANGER OUTLET IS AT A MINIMUN ONE PIPE SIZE LARGER THAN THE INLET PIPING TO THE HEAT EXCHANGERS PIPING ARRANGEMENT PER NFPA-20. PIPING BY OTHER. 2 3 2 ENGINE COOLING WATER PIPED TO DRAIN 1 NOTES: PUMP DISCHARGE CONNECTION 4 3 3 RAW WATER INLET FLOW RAW WATER OUTLET FLOW FRONT OF ENGINE ENGINE HEAT EXCHANGER 2 SIMILAR TO ASSEMBLY MATERIAL ENGR DATE DRWN NO N/A KRWAULIGMAN 3/30/2015 MALAUER CONTROLLED DRAWING YES SCALE 105° F TEMPERATURE SWITCH BYPASS LINE INDICATING PLATE (QTY 2) PRESSURE GAUGE SHUT-OFF VALVE DATE 14AUG03 04APR06 30MAR15 C130977 1 MM [INCH] UNITS 1 PAGE OF 1 C REV Fire Protection Products, Inc. NFPA-20 COOLING LOOP PIPING DETAIL NTS PART NO. NAME AUTOMATIC LINE INDICATING PLATE (QTY 2) MACHINE TOLERANCE inch DECIMAL mm 1.5 X. X.X 0.06 0.8 0.03 X.XX 0.3 0.01 0.025 X.XXX X.XXXX 0.001 ANGULAR: 0.5 FABRICATION TOLERANCE inch DECIMAL mm 3 X. X.X 0.12 1.5 0.06 X.XX ANGULAR: 1.0 APVD PIPING KIT TO CHARGE AIR COOLER OR HEAT EXCHANGER 1 DWN MAL JJW KFB SOLENOID VALVE (NOT USED WITH VERTICAL TURBINE FIRE PUMPS) SHUT-OFF VALVE (QTY 4) 0-60 PSI PRESSURE GAUGE THIS DRAWING AND THE INFORMATION HEREON ARE OUR PROPERTY AND MAY BE USED BY OTHERS ONLY AS AUTHORIZED BY US. UNPUBLISHED--ALL RIGHTS RESERVED UNDER THE COPYRIGHT LAWS UNION (QTY 2) WYE STRAINER (QTY 2) PRESSURE REGULATOR (QTY 2) PRESSURE SENSOR (COOLING LOOP) ECN# N/A 540 3633 PRESSURE SENSOR (HEAT EXCHANGER OUTLET) 2 REV DESCRIPTION ISSUED ENGINEERING DRAWING A ADDED VALVE INDICATOR OPEN/CLOSE TO LOOP B C ADDED NEW ALARMS TO PIPING KIT A B C D TYPICAL EXHAUST PIPING DETAIL PER NFPA-20 2003 English to Turkish Translation NFPA-20’YE GÖRE TİPİK EGZOST BORUSU DETAYI 2003 Ingilizceden Türkçeye tercüme English Text Türkçe Metin INSTALLATION GUIDELINES MONTAJIN ANA NOKTALARI 1. REFER TO NFPA-20 SECTION 11.5 FOR ADDITIONAL INFORMATION. NOTE, OTHER PIPING SYSTEMS ARE POSSIBLE. SCHEMATIC IS FOR EGRESS THRU WALL. 1. İLAVE BİLGİLER İÇİN NFPA-20’NİN 20. BÖLÜMÜNÜN 11.5’E BAŞVURUNUZ. BAŞKA BORULAMA SİSTEMLERİ DE MÜMKÜNDÜR. ŞEMATİK DUVARDAN DIŞARI ATILMA İÇİNDİR. 2. THE EXHAUST PIPING SYSTEM AND SILENCER SHALL BE SUITABLE FOR THE USE INTENDED, AND THE EXHAUST BACK PRESSURE SHALL NOT EXCEED THE ENGINE MANUFACTURER’S RECOMMENDATIONS (SEE WARNING BELOW). 1. EGZOST BORULAMA SİSTEMİ VE SUSTURUCU AMAÇLANAN KULLANIM İÇİN UYGUN OLACAKTIR VE EGZOSTUN GERİ TAZYİKİ MOTOR ÜRETİCİSİNİN TAVSİYELERİNİ AŞMAYACAKTIR (AŞAĞIDAKİ UYARIYA BAKINIZ). 3. THE EXHAUST PIPE SHALL NOT BE ANY SMALLER IN DIAMETER THAN THE ENGINE EXHAUST OUTLET AND EXHAUST PIPE. 3. EGZOST BORUSU, MOTOR EGZOST ÇIKIŞINDAN VE EGZOST BORUSUNDAN DAHA KÜÇÜK ÇAPTA OLMAYACAKTIR. 4. THE EXHAUST PIPE SHALL BE COVERED WITH HIGH-TEMPERATURE INSULATION OR OTHERWISE GUARDED TO PROTECT PERSONNEL FROM INJURY. 4. EGZOST BORUSU PERSONELİ YARALANMAKTAN KORUMAK İÇİN YÜKSEK ISIYA DAYANIKLI YALITIMI İLE KAPLANMIŞ OLACAK VEYA GÜVENLİK İÇİNDE OLACAKTIR. 5. THE SYSTEM MUST BE SUPPORTED SUCH THAT THERE IS NO WEIGHT ON THE FLEXIBLE EXHAUST CONNECTION. 5. SİSTEM, ESNEK EGZOST BAĞLANTILARININ ÜZERİNDE AĞIRLIK OLMAYACAK ŞEKİLDE DAYANIKLI OLACAKTIR. 6. THE EXHAUST PIPE SHALL BE POSITIONED IN SUCH A WAY AS TO PREVENT EXHAUST GASES FROM RE-ENTERING IN THE PUMP ROOM. 6. EGZOST BORUSU, EGZOST GAZLARININ POMPA ODASINA GERİ GİRMESİNİ ÖNLEYECEK BİR ŞEKİLDE YERLEŞTİRİLMİŞ OLACAKTIR. 7. EHXAUST PIPE AND THE POINT OF EGRESS FROM THE PUMP ROOM SHALL BE CONSTRUCTED OR INSULATED SO THAT IT DOES NOT CAUSE A FIRE IGNITION RISK TO THE STRUCTURE. 7. EGZOST BORUSU VE POMPA ODASINDAN ÇIKIŞ NOKTASI YAPIYA BİR YANGIN ATEŞLEME RİSKİNE NEDEN OLMAYACAK ŞEKİLDE İNŞA EDİLMELİ DİR. 8. EXHAUST SYSTEM SHALL TERMINATE OUTSIDE THE STRUCTURE AT A POINT WHERE HOT GASES, SPARKS, OR PRODUCTS OF COMBUSTION WILL DISHCARGE TO A SAFE LOCATION. 8. EGZOST SISTEMİ, YAPININ DIŞ TARAFINDA, SICAK GAZLARIN, KIVILCIMLARIN VEYA YANICI MALZEMELERİN BOŞALTILDIĞI GÜVENLİ BİR YERDEKİ NOKTADA SON BULACAKTIR. 9. EXHAUST SYSTEM TERMINATIONS SHALL NOT BE DIRECTED TOWARDS COMBUSTIBLE MATERIAL OR STRUCTURES, OR INTO ATMOSPHERES CONTAINING FLAMMABLE GASES, FLAMABLE VAPORS, OR COMBUSTIBLE DUST. 9. EGZOST SİSTEMİNİN ÜÇLARI, YANICI MADDELERE VEYA YAPILARA VEYA YANICI GAZLAR İÇEREN ATMOSFERLERE, YANICIBUHARLARA VEYA YANICI TOZLARA DOĞRU OLMAYACAKTIR. 10. PROPERLY SIZED LOUVERS FOR COMBUSTION AIR AND FOR ROOM COOLING AND VENTILATION SHALL BE PROVIDED. 10. YANICI HAVA VE ODAYI SOĞUTMA VE HAVALANDIRMA İÇİN UYGUN ÖLÇÜLERDEKİ PANJURLAR TEMİN EDİLECEKTİR. WARNING: UYARI: THE BACK PRESSURE TO THE ENGINE EXHAUST CONSIDERABLY INFLUENCES THE POWER OF THE ENGINE AND ITS THERMAL LOADINGS. EXCESSIVE BACK PRESSURE MEASURED AT THE ENGINE EXHAUST OUTLET CONNECTION (POINT “A”) DECREASES POWER, INCREASES THE TEMPERATURE OF THE EXHAUST GAS, PRODUCES MOTOR EGZOSTUNUN ARKA TAZYİKİ MOTORUN GÜCÜNÜ VE ONUN TERMAL YÜKLEMELERİNİ GÖZLE GÖRÜLÜR ŞEKİLDE ETKİLER. MOTORUN EGZONS ÇIKIŞ BAĞLANTISINDA (“A” NOKTASI) ÖLÇÜLMÜŞ OLAN AŞIRI ARKA YAZYİK, EGZOST GAZININ ISISINI ARTIRIR, DUMAN ÜRETİR, YAKIT TÜKETİMİNİ ARTIRIR, DAHİLİ SOĞUTMA SUYUNDA KÜKÜRT OLUŞTURUR, (YAĞLAYICI YAĞLARDA C132543 SMOKE, INCREASES FUEL CONSUMPTION, SULPHURISES THE INTERNAL COOLING WATER (WITH SUBSEQUENT DAMAGE TO THE LUBRICANTS) AND PRODUCES SERIOUS CONSEQUENCES FOR OTHER ENGINE ELEMENTS (i.e. TURBOCHARGER, etc.) SONRADAN MEYDANA GELEN ZARAR İLE) VE MOTORUN DİĞER ELEMANLARI İÇİN CİDDİ SONUÇLAR ÜRETİR (ÖRNEĞİN: TURBO YÜKLEYİCİ, VS.) RAIN CAP YAĞMUR KAPAĞI WALL THIMBLE DUVAR YÜKSÜĞÜ AIR SUPPLY VENTILATOR HAVA TEMİN EDİCİ VANTİLATÖR DAMPERS BORU ANAHTARLARI FLEX. EXHAUST CONNECTION ESNEK EGZOST BAĞLANTISI AIR DISCHARGE VENTILATOR AYI DIŞARIYA ATAN VENTİLATÖR POINT “A” “A” NOKTASI EXHAUST INSULATION EGZOST YALITIMI C132543 Wiring Diagram, Mecab – ETS, Cooling Loop Alarms – C072145 English to Turkish Translator English Text Instrument Panel Ground Splice Panel Door Mecab Tachometer Magnetic Pickup Input Magnetic Pickup Ground Ground (MPU Shield) Ground (Main Supply) Ground (Miscellaneous) Switched Power In – B+ (ORS) Crank Disconnect Alarm Battery + Battery + Overspeed Alarm Battery + Energized to Run Relay Automatic Circuit Energized to Run Relay Manual Circuit Test Battery + Overspeed Lamp Low Oil Pressure Alarm Engine Stop SW Input Automatic/Manual Mode Switch Input Low Water Temperature Alarm Oil Pressure Switch Input Engine Run SW Input Excitation “W” Run Circuit Ground (Miscellaneous) Water Temperature Analog Input High Water Temperature Alarm Energized to Stop Solenoid (Low Side SW Output) Energized to Stop Solenoid (Hold) Energized to Stop Solenoid (Pull) Notes: 1) Governor Solenoid Energized to Stop – JU, JW, ZF, ZE 2) Governor Solenoid Energized to Stop – DP Connector Detail DP Only Pin Lock Tab 3) Governor Solenoid Energized to Stop – DQ, DR, DS, DT Connector Detail DQ, DR, DS, DT only Pin Lock Tab 4) Starter Single Starter – JW, DR, DS, DT Standard Dual Starter – JU Standard 24Volt Battery Detail Shown, For 12Volt See 12Volt Battery Detail 5) Single Point Ground Ground Stud Provided on Engine for Junction of Battery Ground Cables, Controller Ground (Terminal 11) and Accessory Ground. Some Starters have Isolated Ground 6) Some Governor Solenoids have Isolated Ground 7) Some Alternators have Isolated Ground 8) Water Solenoid Valve in Raw Water Supply Cooling Loop Valve and Wiring Supplied by others. 5 amp maximum 9) Tachometer / Hourmeter Wiring Detail for Clarke UK Built Engines only Tachometer/Hourmeter wiring detail for Clarke UK Built 12 Volt engines only 10) Dropping Resistors Only Used on 24Volt Applications Tachometer/Hourmeter wiring detail for Clarke UK Built 24 Volt engines only Turkish Text Gösterge Paneli Toprak Bağlantı Panel Kapağı Mecab Takometre Manyetik Pikap Girişi Manyetik Pikap Toprak Toprak (MPU Koruma) Toprak (Ana Besleme) Toprak (Çeşitli) Anahtarlı Güç Giriş – B+ (ORS) Krank Bağlantı Kesilme Alarmı Akü + Akü + Aşırı Hız Alarmı Akü + Röle Otomatik Devresini Çalıştırmak İçin Güç Verilmiş Röle Manüel Devresini Çalıştırmak İçin Güç Verilmiş Test Akü + Aşırı Hız Lambası Düşük Yağ Basıncı Alarmı Motor Durdurma SW Giriş Otomatik / Manüel Mod Anahtar Girişi Düşük Su Sıcaklığı Alarmı Yağ Basıncı Anahtar Girişi Motor Çalıştırma SW Giriş Tahrik “W” Çalışma Devresi Toprak (Çeşitli) Su Sıcaklığı Analog Giriş Yüksek Su Sıcaklığı Alarmı Solenoid Durdurmak İçin Güç Verilmiş (Düşük Taraf SW Çıkış) Solenoid Durdurmak İçin Güç Verilmiş (Tut) Solenoid Durdurmak İçin Güç Verilmiş (Çek) Notlar: 1) Düzenleyici Solenoid Durdurmak İçin Güç Verilmiş – JU, JW, ZF, ZE 2) Düzenleyici Solenoid Durdurmak İçin Güç Verilmiş – DP Yalnızca Bağlayıcı Ayrıntısı DP Pim Kilit Tırnağı 3) Düzenleyici Solenoid Durdurmak İçin Güç Verilmiş – DQ, DR, DS, DT Yalnızca Bağlayıcı Ayrıntısı DQ, DR, DS, DT Pim Kilit Tırnağı 4) Marş Tekli Marş – JW, DR, DS, DT Standardı Çift Marş – JU Standardı 24 Volt Akü Ayrıntısı Gösterilmektedir, 12 Volt İçin Bkz. 12 Volt Akü Ayrıntısı 5) Tekli Nokta Toprak Akü Toprak Kablosu, Kumanda Toprağı (Terminal 11) ve Aksesuar Toprağı Birleştirme İçin Motorda Toprak Saplama Sağlanır. Bazı Marşlar Yalıtılmış Toprağa sahiptir 6) Bazı Düzenleyici Solenoidler Yalıtılmış Toprağa sahiptir 7) Bazı Alternatörler Yalıtılmış Toprağa sahiptir 8) Ham Su Besleme Soğutma Döngüsü Vanasında Su Solenoid Vanası ve Kablo Tesisatı diğerleri tarafından sağlanır. En fazla 5 amp 9) Yalnızca Clarke UK Üretimi Motorlar için Takometre / Saat Ölçer Kablo Tesisatı Ayrıntısı Yalnızca Clarke UK Üretimi 12 Volt motorlar için Takometre / Saat Ölçer kablo tesisatı ayrıntısı 10) Gerilim Düşürücü Dirençler Yalnızca 24 Volt Uygulamalarda Kullanılır Yalnızca Clarke UK Üretimi 24 Volt motorlar için Takometre / Saat Ölçer kablo tesisatı ayrıntısı C136504 RevA Wiring Diagram, Mecab – ETS, Cooling Loop Alarms – C072145 English to Turkish Translator Color Code A – White B – Red C – Orange D – Yellow E – Green G – Blue I – Pink J – Black K – Brown L – Gray M - Purple Legend AB – Alternator Bridge AL – Alternator AM – Automatic Mode Position AVS – Alarm Verify Switch B1 – Battery #1 B2 – Battery #2 BB1 – Battery Bridge #1 BB2 – Battery Bridge #2 BES – Bump Enable Switch BSS – Speed Bump Switch BI – Battery Isolator CS1 – Crank Switch – Battery #1 CS2 – Crank Switch – Battery #2 CB – Coolant Bridge DIA – Diagnostic Gauge ERR – Engine Run Relay ERS Emergency Run Switch ETR – Energized to Run Solenoid Relay HRWTS – High Raw Water Temperature Switch LFAB – Low Flow/Temperature Alarm Board MDS – Mode Selector Switch MM – Manual Mode Position MML – Manual Mode Indicating Lamp MP – Magnetic Pick-Up MSS – Manual Stop Switch OAL – Over-Speed Alarm Lamp OAR – Over-Speed Alarm Relay OCB – Over-Current Breaker OPR- Oil Pressure Alarm Relay OVRS – Overspeed verify @ 67%/Reset Switch RWPS-H – Raw Water Pressure Sensor, High RWPS-L – Raw Water Pressure Sensor, Low SC1- Starter Contactor Battery #1 SC2 – Starter Contactor Battery #2 SCB – Solenoid Control Board ST – Starter TCS – Temperature Control Solenoid TH – Tachometer - Hourmeter VMG1 – Voltmeter Gauge, Battery #1 VMG2 – Voltmeter Gauge, Battery #2 WS – Water Solenoid Valve WT – Water Temperature N. O. SW 205o F WTR – Water Temperature Alarm Relay Engine 12Volt Battery Detail See Note 1 See Note 2 See Note 3 Dual Starter Arrangement – See Note 4 Single Starter Arrangement – See Note 4 See Note 4 See Note 5 See Note 6 See Note 7 See Note 8 See Note 9 Renk Kodu A – Beyaz B – Kırmızı C – Turuncu D – Sarı E – Yeşil G – Mavi I – Pembe J – Siyah K – Kahverengi L – Gri M – Mor Gösterge AB – Alternatör Köprüsü AL – Alternatör AM – Otomatik Mod Konumu AVS – Alarm Doğrulama Anahtarı B1 – Akü #1 B2 – Akü #2 BB1 – Akü Köprüsü #1 BB2 – Akü Köprüsü #2 BES – Çarpma Etkinleştirme Anahtarı BSS – Hız Çarpma Anahtarı BI – Akü Yalıtıcı CS1 – Krank Anahtarı – Akü #1 CS2 – Krank Anahtarı – Akü #2 CB – Soğutucu Köprüsü DIA – Tanılayıcı Gösterge ERR – Motor Çalıştırma Rölesi ERS – Acil Çalıştırma Anahtarı ETR – Solenoid Rölesini Çalıştırmak İçin Güç Verilmiş HRWTS – Yüksek Ham Su Sıcaklığı Anahtarı LFAB – Düşük Akım/Sıcaklık Alarmı Panosu MDS – Mod Seçici Anahtar MM – Manüel Mod Konum MML – Manüel Mod Belirtme Lambası MP – Manyetik Pikap MSS – Manüel Durdurma Anahtarı OAL – Aşırı Hız Alarmı Lambası OAR – Aşırı Hız Alarmı Rölesi OCB – Aşırı Akım Kesici OPR – Yağ Basıncı Alarmı Rölesi OVRS – Aşırı hız doğrulama @ %67/Sıfırlama Anahtarı RWPS-H – Ham Su Basıncı Sensörü, Yüksek RWPS-L – Ham Su Basıncı Sensörü, Düşük SC1 – Marş Üstlenici Akü #1 SC2 – Marş Üstlenici Akü #2 SCB – Solenoid Kontrol Panosu ST – Marş TCS – Sıcaklık Kontrolü Solenoidi TH – Takometre - Saat Ölçer VMG1 – Voltmetre Sayacı, Akü #1 VMG2 – Voltmetre Sayacı, Akü #2 WS – Su Solenoid Vanası WT – Sı Sıcaklığı N. O. SW 205o F WTR – Su Sıcaklığı Alarm Rölesi Motor 12 Volt Akü Ayrıntısı Bkz. Not 1 Bkz. Not 2 Bkz. Not 3 Çift Marş Düzenlemesi – Bkz. Not 4 Tekli Marş Düzenlemesi – Bkz. Not 4 Bkz. Not 4 Bkz. Not 5 Bkz. Not 6 Bkz. Not 7 Bkz. Not 8 Bkz. Not 9 C136504 RevA Wiring Diagram, Mecab – ETS, Cooling Loop Alarms – C072145 English to Turkish Translator See Note 10 Bkz. Not 10 Clarke Fire Protection Products, Inc. Wiring Diagram, Mecab – Energized to Stop, Cooling Loop Alarms Clarke Fire Protection Products, Inc. Kablo Tesisatı Şeması, Mecab – Durdurmak İçin Güç Verilmiş, Soğutma Döngüsü Alarmları C136504 RevA Clarke USA Supplied Lead‐Acid Battery Kit Specifications: All UL/FM NFPA 20 Engine Models – C131885 English to Turkish Translator English Text Clarke Fire Protection Products, Inc. Clarke USA Supplied Lead-Acid Battery Kit Specifications All UL/FM NFPA20 Engine Models Turkish Text Clarke Fire Protection Products, Inc. Clarke ABD Tarafından Sağlanan Kurşun Asit Akü Takımı Teknik Özellikleri Tüm UL/FM NFPA20 Motor Modelleri Clarke Akü Parça Numarası Akü Modeli # (Sayı) J537’ye göre SAE# Motor Modeli Başvurusu Ürt. (Üretici) Volt Genel Boyutlar mm cinsinde U x G x Y (Uzunluk x Genişlik x Yükseklik inç (milimetre)) Ağırlık lb (kg) (pound (kilogram)) Islak Kuru Performans Düzeyi Soğuk Çalıştırma Amperi @ O F (CCA) (3A) Çalıştırma Amperi @ 32 F (CA) Yedek Kapasite (Dakika) (3B) Derecelendirme @ 80 F (Amper Saati) (3C) Deka Clarke Battery P/N (Part Number) Battery Model # (Number) SAE# per J537 Engine Model Reference Mfg. (Manufacturer) Volts Overall Dimensions L x W x H in (mm) (Length x Width x Height inches (millimeters)) Weight lb (kg) (pound (kilogram)) Wet Dry Performance Level Cold Cranking Amps @ O F (CCA) (3A) Cranking Amps @ 32 F (CA) Reserve Capacity (Minutes) (3B) Rating @ 80 F (Amp Hours) (3C) Deka Note: All information provided per Deka Commercial Battery Link, http://www.eastpenn-deka.com/assets/base/0010.pdf Not: Tüm bilgiler Deka Ticari Akü bağlantısına göre sağlanır: http://www.eastpenn-deka.com/assets/base/0010.pdf DIA H Post Connector Detail Post Connector Dimensions in (mm) Positive Negative DIA H Nokta Bağlayıcı Ayrıntısı (mm) cinsinde Nokta Bağlayıcı Boyutları Pozitif Negatif Notes: 1. Batteries equipped with handles and lifting ledges. 2. Batteries are manufactured in black polypropylene case and cover. 3. Meets SAE storage battery requirements for SAE J537 JUN92. 3A. While discharging specified amps, the battery voltage across the terminals after 30 seconds is 1.2 volts/cell or greater. 3B. Time (minutes) to discharge battery at 25 amps when voltage across the battery terminals have fallen to 1.75 volts/cell. 3C. Amp Hours = (reserve (minutes) x 25 amps)/60min/hr 4. Battery should set into battery rack on ½” plywood (or equal) to provide insulation and support. 5. Battery meets NFPA 20 2010 requirements: At 40 degrees Farenheit (4.5 degrees Celsius), each battery unit shall have twice the capacity sufficient to maintain the cranking speed recommended by the engine manufacturer through a 3minute attempt-to[start cycle, which is six consecutive cycles of 15 seconds of cranking and 15 seconds of rest (Section 11.27.2.1.4). Batteries shall be sized on a calculated capacity of 72 hours of standby power followed by three 15second cycles per battery unit, without ac power being available for battery charging (Section 11.2.7.1.5). Essential loads, including the engine, controller, and all pump equipment combined, shall not exceed 0.5 ampere each for a total of 1.5 amperes, on continuous bases (Section 11.2.7.2.3.2). 6. Battery cable length (total circuit) should not exceed the guidelines for minimum size or max circuit resistance as provided on the installation & operation data sheet for the given engine model. 7. Batteries are shipped dry charged and without electrolyte (by others). See “Activation – Dry Charged Batteries.” Notlar: 1. Aküler kulplara ve kaldırma çıkıntılarına sahiptir. 2. Aküler siyah polipropilen kasa ve kapakla üretilir. 3. SAE J537 JUN92 için SAE akü gereksinimlerini karşılar. 3A. Belirtilen amperler boşaltılırken, 30 saniye sonra terminaller boyunca akü gerilimi 1,2 volt/hücre veya daha büyük olur. 3B. Akü terminalleri boyunca gerilim 1,75 volt/hücre değerine düştüğünde, 25 amperde aküyü boşaltma süresi (dakika). 3C. Amper Saati = (ters (dakika) x 25 amper)/60 dk./sa. 4. Yalıtım ve destek sağlamak için, akü ½” kontrplak (veya eş değeri) üzerinde akü rafına oturtulmalıdır. 5. Akü NFPA 20 2010 gereksinimlerini karşılar. 4,5 Santigrat derecede (40 Fahrenhayt derece), her bir akü ünitesi, 3 dakikalık bir döngü başlatma denemesi boyunca (15 saniyelik başlatma ve 15 saniyelik beklemeden oluşan altı ardışık döngüdür) motor üreticisinin önerdiği çalıştırma hızını korumak için yeterli iki kat kapasiteye sahip olacaktır (Kısım 11.27.2.1.4). Akü şarj etme için AC gücü olmadan, aküler, akü ünitesi başına üç tane 15 saniyelik döngünün izlediği 72 saatlik bekleme gücünün hesaplanan kapasitesi temelinde boyutlandırılacaktır (Kısım 11.2.7.1.5). Motoru, kumandayı ve birleştirilmiş tüm pompa ekipmanını içeren ana yükler, sürekli temellerde 1,5 amperlik toplam için her birinde 0,5 amper değerini aşmayacaktır (Kısım 11.2.7.2.3.2). C136500 RevJ Clarke USA Supplied Lead‐Acid Battery Kit Specifications: All UL/FM NFPA 20 Engine Models – C131885 English to Turkish Translator 6. Activation – Dry Charged Batteries: 1. Use premix battery grade electrolyte (Specific Gravity: 1.265) Each 908D battery will take approximately 18 quarts (16.5 liters) of electrolyte. 2. Remove the six vents caps for each battery. 3. With proper safety gear (eye protection, gloves, etc.) carefully fill each of the six cells to cover the plates and just below the vent well. DO NOT OVERFILL! 4. Re-install vent caps. 5. It is recommended that the battery chargers in fire pump controller are used for 1 day prior to putting batteries/engine in service. 6. After initial charge, check level of electrolyte in all cells, If required, add additional electrolyte to bring all levels to the bottom of the vent wells. DO NOT OVERFILL! If batteries require top-off while in service, add water. DO NOT ADD ACID. 7. Akü kablosu (toplam devre), belirli motor modeline yönelik kurulum ve çalıştırma veri sayfasında sağlanan, minimum boyuta veya en fazla devre direncine yönelik kılavuzları aşmamalıdır. Aküler kuru şarjlı olarak ve elektrolit olmadan (diğerleri tarafından) nakledilir. Bkz. “Etkinleştirme – Kuru Şarjlı Aküler” Etkinleştirme – Kuru Şarjlı Aküler: 1. Ön karışım akü sınıfı elektrolit kullanın (Özgül Ağırlık: 1.265) Her 908D akü yaklaşık 16,5 litre elektrolit alacaktır. 2. Her bir akü için altı havalandırma kapağını çıkarın. 3. Uygun güvenlik donanımıyla (göz koruması, eldiven vb.), altı hücrenin her birini plakaları kapatacak ve hemen havalandırmanın altında olacak şekilde dikkatlice doldurun. AŞIRI DOLDURMAYIN! 4. Havalandırma kapaklarını geri takın. 5. Yangın pompası denetleyicideki akü şarjlarının, akülerin/motorun hizmete alınmasından 1 gün öncesinde kullanılması önerilir. 6. İlk şarjdan sonra tüm hücrelerdeki elektrolit düzeyini kontrol edin. Gerekirse, tüm düzeyleri havalandırma haznelerinin alt kısmına getirmek için elektrolit ekleyin. AŞIRI DOLDURMAYIN! Aküler kullanım sırasında doldurma gerektirirse su ekleyin. ASİT EKLEMEYİN. Akü Rafı Öğe #2 Clarke Parça Numarası Battery Rack Item #2 Clarke P/N (Part Number) 12Volt & 24Volt Battery Cable Specifications Item Clarke P/N (Part Number) AWG Size Type Terminal 1 Terminal 2 Negative Post Positive Post Ring 12 Volt ve 24 Volt Akü Kablosu Teknik Özellikleri Öğe Clarke Parça Numarası AWG Boyut Tip Terminal 1 Terminal 2 Negatif Nokta Pozitif Nokta Halka Item #3 Clarke P/N (Part Number) Negative Post Ground Stud Length = 72 inches Öğe #3 Clarke Parça Numarası Negatif Nokta Toprak Saplama Uzunluk = 182,88 cm Item #4 Clarke P/N (Part Number) Positive Post Starter Stud Length = 72 inches Öğe #4 Clarke Parça Numarası Pozitif Nokta Marş Saplama Uzunluk = 182,88 cm Item #5 Clarke P/N (Part Number) Positive Post Negative Post Length = 12 inches Öğe #5 Clarke Parça Numarası Pozitif Nokta Negatif Nokta Uzunluk = 30,48 cm 12Volt 908D Battery Kit 12 Volt 908D Akü Kiti C136500 RevJ Clarke USA Supplied Lead‐Acid Battery Kit Specifications: All UL/FM NFPA 20 Engine Models – C131885 English to Turkish Translator Clarke Parça Numarası (Şekil 1) Öğe Miktar Açıklama Akü 908D, Kuru 1400 CCA, 12 Volt Akü Rafı Akü Kablosu – Negatif/Toprak Akü Kablosu – Pozitif/Marş NOT: ÖLÇEKLENMEYEN KABLOLAR Şekil 1 12 V Negatif Toprak Sistemi Marş #1’e (Yalnızca JU4/6H Modelleri) veya Marş Üstleniciye Toprağa Marş #2’ye (Yalnızca JU4/6H Modelleri) veya Marş Üstleniciye Clarke P/N (Part Number) (Figure 1) Item Quantity Description Battery-908D, Dry 1400 CCA, 12Volt Battery Rack Battery Cable – Negative/Ground Battery Cable – Positive/Starter NOTE: CABLES NOT TO SCALE Figure 1 12V Negative Ground System To Starter #1 (JU4/6H Models Only) or Starter Contractor To Ground To Starter #2 (JU4/6H Models Only) or Starter Contractor 24Volt 908D Battery Kit Clarke P/N (Part Number) (Figure 2) Item Quantity Description Battery-908D, Dry, 1400 CCA 12Volt Battery Rack Battery Cable – Negative/Ground Battery Cable – Positive/Starter Battery Cable – Negative to Positive Figure 2 24Volt Negative Ground System To Ground To Starter #1 (JU4/6H Models Only) or Starter Contractor To Starter #2 (JU4/6H Models Only) or Starter Contractor 24 Volt 908D Akü Kiti Clarke Parça Numarası (Şekil 2) Öğe Miktar Açıklama Akü 908D, Kuru, 1400 CCA 12 Volt Akü Rafı Akü Kablosu – Negatif/Toprak Akü Kablosu – Pozitif/Marş Akü Kablosu – Negatiften Pozitife Şekil 2 24 V Negatif Toprak Sistemi Toprağa Marş #1’ye (Yalnızca JU4/6H Modelleri) veya Marş Üstleniciye Marş #2’ye (Yalnızca JU4/6H Modelleri) veya Marş Üstleniciye C136500 RevJ Notes: FEDERATED 24V 20.75 x 11.0 x 10.0 130 80 (527 x 279 x 254) (59.1) (36.4) Wet 1400 Post Connector Detail DIA H 1700 430 NEGATIVE DIA H DIA H 3/4" 3/4" 5/8" 3/4" (19.1 mm) (19.1 mm) (15.9 mm) (19.1 mm) POSITIVE Post Connector Dimensions in(mm) Note: All information provided per Federated Commerical Battery Link ALL JX6H, DP, DQ, DR, DS, & DT L x W x H in(mm) 1 2.75 2.87 4X 1.75 4X DESCRIPTION J ADDED DP,DQ,DR,DS, & DT ENGINE MODELS UPDATED DRAWINGS TO K NFPA-20 2013 STANDARDS L REPLACED BATTERY PHOTO, ADDED ZF6H REV AMC SAP GRM 3522 3968 DWN 2355 ECN# JCA APVD 21MAY14 11FEB14 23SEP11 DATE Activation - Dry Charged Batteries: 1. Use premix battery grade electrolyte (Specific Gravity: 1.265) Each 908D battery will take approximately 18 qts (16.5 L) of electrolyte. 2. Remove the six vents caps for each battery. 3. With proper safety gear (eye protection, gloves, etc.) carefully fill each of the six cells to cover the plates and just below the vent well. DO NOT OVERFILL! 4. Re-install vent caps. 5. It is recommended that the battery chargers in fire pump controller are used for 1 day prior to putting batteries/engine in service. 6. After initial charge, check level of electrolyte in all cells. If required, add additional electrolyte to bring all levels to the bottom of the vent wells. DO NOT OVERFILL! If batteries require top-off while in service, add water. DO NOT ADD ACID. 1 2 43.75 4X 4X BATTERY RACK ITEM # 2 CLARKE P/N:C07001 3.75 12.25 POSITIVE POST POSITIVE POST 2 0 (70) Positive Post Negative Post LENGTH = 72 INCHES GROUND STUD LENGTH = 72 INCHES STARTER STUD + LENGTH = 12 INCHES - NEGATIVE POST ITEM # 5 ( CLARKE P/N: C07631) + ITEM # 4 ( CLARKE P/N: C071172) - ITEM # 3 ( CLARKE P/N: C071171) C07631 NEGATIVE POST 5 12 V & 24 V BATTERY CABLE SPECIFICATIONS Terminal 1 Terminal 2 Size Item Clarke P/N AWG Type Type (mm Negative 2 Ring 21 " (12 mm) 3 C071171 0 (70) Post 2 1 4 C071172 0 (70) Positive Post Ring 2 " (12 mm) - 3 4 TO GROUND 3 . mm .5 .8 .3 .025 .06 .03 .01 .001 inch DECIMAL X. X.X X.XX . mm .12 .06 inch FABRICATION TOLERANCES DECIMAL X. X.X X.XX X.XXX X.XXXX MACHINE TOLERANCES THIS DRAWING AND THE INFORMATION HEREON ARE OUR PROPERTY AND MAY BE USED BY OTHERS ONLY AS AUTHORIZED BY US. UNPUBLISHED--ALL RIGHTS RESERVED UNDER THE COPYRIGHT LAWS. 1 TO STARTER # 2 (JU4/6H MODELS ONLY) OR STARTER CONTACTOR NOTE: CABLES NOT TO SCALE YES C07633 C07001 CO71171 C071172 C07631 NO 1 JAUGENSTEIN 31JUL10 KWAULIGMAN 1 3 - Figure 2: 24V Negative Ground System 1 2 3 4 5 Description 1 1 Fire Protection Products, Inc. 4 4 TO STARTER # 2 (JU4/6H MODELS ONLY) OR STARTER CONTACTOR TO STARTER # 1 (JU4/6H MODELS ONLY) OR STARTER CONTACTOR CLARKE USA SUPPLIED LEAD-ACID BATTERY KIT SPECIFICATIONS 5 5 TO GROUND Battery - 908D, Dry, 1400 CCA 12V Battery Rack Battery Cable - Negative/Ground Battery Cable - Positive/Starter Battery Cable - Negative to Postive MM [INCH] C131885 1 1 (FOR USE ON FIRE PUMP INSTALLATIONS THAT ARE UL, FM, & NFPA20) + 3 4 2 2 2 2 Item Clarke P/N QTY CONTROLLED DRAWING Battery - 908D, Dry, 1400 CCA, 12V Battery Rack Battery Cable - Negative/Ground Battery Cable - Positive/Starter Description 12V 908D BATTERY KIT, CLAKE P/N: C07844 (FIGURE 1) 24V 908D BATTERY KIT, CLAKE P/N: C07688 (FIGURE 2) 185 Cold Rating @ Reserve Cranking Cranking 80 F Amps @ Capacity Dry Amps @ (Amp 0F (Minutes) 32 F (CA) Hours) (CCA) (3B) (3C) (3A) Performance Level 1. Batteries equipped with handles and lifting ledges. Item Clarke P/N QTY 2. Batteries are manufactured in black polypropylene case and cover. 1 C07633 2 3. Meets SAE storage battery requirements for SAE J537 JUN92. 2 C07001 1 3A.While discharging specified amps, the battery voltage across the terminals after 30 seconds is 1.2 volts/cell or 3 C071171 2 greater. 4 C071172 2 3B. Time (minutes) to discharge battery at 25 amps when voltage across the battery terminals have fallen to 1.75 volts/cell. 3C. Amp Hours = (reserve (minutes) x 25 amps)/60 min/hr 4. Battery should set into battery rack on 21" plywood (or equal) to provide insulation and support. Figure 1: 5. Battery meets NFPA 20 2013 requirements: Section 11.2.7.2.1.4: At 40 F (4 C), each battery unit shall have twice the 12V Negative capacity sufficient to maintain the cranking speed recommended by the engine manufacturer through a 3-minute Ground System attempt-to-start cycle, which is six consecutive cycles of 15 seconds of cranking and 15 seconds of rest. Section 11.2.7.2.1.5: Batteries shall be sized, based on calculations, to have capacity to carry the loads defined in 11.2.7.2.3 for 72 TO hours of standby power followed by three 15-second attempt-to-start cycles per battery unit as defined in 11.2.7.2.1.4 STARTER # 1 (JU4/6H MODELS ONLY) without ac power being available for battery charging. Section 11.2.7.2.3.2: Essential loads, including the engine, controller, OR STARTER CONTACTOR and all pump room equipment combined, shall not exceed 0.5 ampere each for a total of 1.5 amperes, on continuous basis. 6. Battery cable length (total circuit) should not exceed the guidelines for minimum size or max circuit resistance as provided 4 on the installation & operation data sheet for the given engine model. 1 7. Batteries are shipped dry charged and without electrolyte (by others). See "Activation - Dry Charged Batteries." 908D Dry 8D-900 12V All JU4H, JU4R, JU6H, JW6H, ZF6H C07633 Mfg. Volts Engine Clarke SAE # Battery Model Battery per Model # P/N J537 Reference Weight lb (kg) - Overall Dimensions + - - + + + + Clarke Fuel Tank and Fuel Supply Schematic Per NFPA 20 – C132026 English to Turkish Translator English Text Turkish Text Clarke Fire Protection Products, Inc. NFPA 20 Uyarınca Yakıt Tankı ve Yakıt Besleme Şeması Notes: 1. Refer to the latest edition of NFPA 20 for additional requirements. Also, install tank in accordance with the requirements of the authority having jurisdiction. 2. Fuel supply tank shall have a capacity at least equal to one gallon per hp (5.07liters per kw), plus 5 percent volume for expansion and 5 percent volume for sump. 3. Downpipe recommended for fuel return line to prevent foaming inside tank. Terminate 3”-6” (76.2mm-152.4mm) from tank bottom. 4. Downpipe recommended for fuel line to prevent foaming inside tank. Terminate 3”-6” (76.2mm-152.4mm) from tank bottom. 5. The engine manufacturer’s fuel pump static head pressure limits shall not be exceeded when the level of fuel in the tank is at a maximum. 6. Fuel piping shall not be galvanized steel or copper. 7. The fuel supply tank and fuel shall be reserved exclusively for the fire pump diesel engine. 8. The fuel return line shall be installed according to the engine manufacturer’s recommendation. In zones where freezing temperatures (32°F (0°C)) could be encountered, the fuel tank shall be located in the pump room. 9. In areas where local air quality management regulations only allow the use of DF#1 fuel, and no diesel fire pump driver is available listed for use with DF#1 fuel, an engine listed for DF#2 shall be permitted to be used but shall have the nameplate rated horsepower derated 10 percent, provided the engine manufacturer approves the use of DF#1 fuel. 10. The grade of the fuel oil shall be indicated on the fuel tank by letters that are a minimum of 6” (152mm) in height and in contrasting color to the tank. 11. Consult engine manufacturer’s installation and operation data sheet for the specific engine model to determine minimum fuel supply and return pipe diameters. Notlar: 1. Ek gereksinimler için en son NFPA 20 yayınına başvurun. Ayrıca, tankı yetkili makamın gereksinimlerine uygun olarak kurun. 2. Yakıt besleme tankı, genleşme için yüzde 5 ve karter yağ haznesi için yüzde 5 hacim eklenmek üzere, kw başına en az 5,07 litre değerine eşit kapasiteye sahip olacaktır. 3. Tank içinde köpüklenmeyi önlemek amacıyla yakıt dönüş hattı için boşaltma borusu önerilir. Tank altından 76,2 mm152,4 mm sonlandırın. 4. Tank içinde köpüklenmeyi önlemek amacıyla yakıt hattı için boşaltma borusu önerilir. Tank altından 76,2 mm-152,4 mm sonlandırın. 5. Tanktaki yakıt düzeyi en yüksek noktadayken, motor üreticisinin yakıt pompası statik basınç sınırları aşılmayacaktır. 6. Yakıt boruları galvanizli çelik veya bakır olmayacaktır. 7. Yakıt besleme tankı ve yakıt özel olarak yangın pompası dizel motoru için ayrılacaktır. 8. Yakıt dönüş hattı, motor üreticisinin önerisine göre kurulacaktır. Yakıt tankı, dondurucu soğukların (0°C) yaşanabileceği bölgelerde pompa odasında konumlandırılacaktır. 9. Yerel hava kalitesi yönetimi yönetmeliklerinin yalnızca DF#1 yakıt kullanımına izin verdiği ve DF#1 yakıtla kullanım için listelenen hiçbir dizel yangın pompası sürücüsünün olmadığı alanlarda, DF#2 için listelenen bir motorun kullanılmasına izin verilecek ama motor üreticisinin DF#1 yakıt kullanımını onaylaması koşuluyla, yüzde 10 düşürülmüş nominal beygir gücü ad plakasına sahip olacaktır. 10. Yakıtın kalitesi yakıt tankı üzerinde, yüksekliği en az 152 mm ve tankla zıt renklerde olan harflerle belirtilecektir. 11. En az yakıt besleme ve dönüş borusu çaplarını belirlemek için, üreticinin belirli motor modeline yönelik kurulum ve çalıştırma veri sayfasına başvurun. Item Quantity Description (all fittings by others) 2” Fill cap – with provision for padlock, combined with removable strainer (maximum .06 mesh) Double tap bushing, 1” x .50” Vent cap, 1.25” NPT Direct reading tank gauge, 2” NPT Pipe plug for drain, 1” NPT Pipe tee, 1.25” x 1.25” x table 2 (minimum fuel return size) Pipe plug, 4” NPT (provision for emergency relief vent) Pipe plug, 2” NPT (provision for low fuel alarm access) Pipe nipple, table 2 (minimum fuel supply size) x close Pipe tee, .50” x .50” x table 2 (minimum fuel return size) Stop cock, table 2 (minimum fuel supply size) (with provision for padlock) Double tab bushing, 3” x 2” Check valve, table 2 (minimum fuel return size) (prevents siphoning) Öğe Miktar Açıklama (tüm bağlantı parçaları diğerleri tarafından) 2” Doldurma kapağı – çıkarılabilir filtreyle (en fazla 0,06 elek gözü) birleşik, kilit karşılıklı Çift vuruş kovan, 1” x 0,50” Havalandırma kapağı, 1,25” NPT Doğrudan okuyan tank göstergesi, 2” NPT Boşaltma için boru tapası, 1” NPT T bağlantı borusu, 1,25” x 1,25” x tablo 2 (en az yakıt dönüşü boyutu) Boru tapası, 4” NPT (acil durum boşaltma vanası karşılığı) Boru tapası, 2” NPT (düşük yakıt alarmı erişimi karşılığı) Boru nipeli, tablo 2 (en az yakıt besleme boyutu) x kapalı T bağlantı borusu, 0,50” x 0,50” x tablo 2 (en az yakıt dönüşü boyutu) Vana, tablo 2 (en az yakıt besleme boyutu) (kilit karşılıklı) Çift vuruş kovan, 3” x 2” Clarke Fire Protection Products, Inc. Fuel Tank and Fuel Supply Schematic Per NFPA 20 C136501 RevC Clarke Fuel Tank and Fuel Supply Schematic Per NFPA 20 – C132026 English to Turkish Translator Kontrol vanası, tablo 2 (en az yakıt dönüş boyutu) (sifonlamayı önler) Tipik Tek duvar yakıt tanklı JX6H gösteriliyor Esnek dönüş bağlantısı hortumu Esnek besleme bağlantısı hortumu Yakıt pompası Bkz. tablo 1 Krank mili Not #4 Not #5 (en fazla basınç) Yakıt besleme hattı (diğerleri tarafından) Genleşme için yüzde 5 hacim Bkz. not 8 Karter yağ haznesi için yüzde 5 hacim Yakıt dönüş hattı (diğerleri tarafından) Not #3 En az 2” boru bacağı önerilir Typical JX6H shown with single wall fuel tank Flexible return connection hose Flexible supply connection hose Fuel pump See table 1 Crankshaft Note #4 Note #5 (maximum head) Fuel supply line (by others) 5percent volume for expansion See note 8 5 percent volume for sump Fuel return line (by others) Note #3 2” minimum pipe legs recommended Table 1 Engine model Tablo 1 Motor modeli Table 2 Engine model Minimum fuel supply size inches (millimeters) Minimum fuel return size inches (millimeters) Tablo 2 Motor modeli En az yakıt besleme boyutu milimetre (inç) En az yakıt dönüş boyutu milimetre (inç) C136501 RevC Clarke Wiring Diagram C07651 English to Turkish Translator English Text Turkçe Metin WIRING DIAGRAM J.W. HEATER 115/230VAC Notes: 1. 2. KABLOLAMA ŞEMASI J.W. ISITICI 115/230 V DİREKT AKIM VARIFY HEATER VOLTAGE PRIOR TO CONNECTING TO POWER SOURCE, VARIFY SUPPLY CIRCUIT HAS ADEQUATE AMPERAGE FOR J.W. HEATER AND LUBE OIL HEATER WHEN PROVIDED. - - - - WIRING SUPPLIED BY OTHERS DDFP JDFP VMFP ON OFF VAC POWER SEE NOTE #1 JACKET WATER HEATER WITH VOLTAGE & WATTAGE IDENTIFICATION OPTIONAL LUBE OIL HEAER WITH VOLTAGE AND WATTAGE IDENTIFICATION THERMOSTAT Notlar: 1. GÜÇ KAYNAĞINA BAĞLAMADAN ÖNCEISITICI VOLTAJINI KONTROL EDİN. DONANIM DEVRESİNİN J.W ISITICISI VE YAĞLAMA YAĞI ISITICISI İÇİN YETERLİ AMPER OLUP OLMADIĞINI KONTROL EDİN. 2. ------ BAŞKALARI TARAFINDAN TEMİN EDİLEN KABLOLAMA DDFP JDFP VMFP AÇIK KAPALI VAC GÜCÜ 1# NOTA BAKINIZ VOLTAJ VE VAT KİMLİKLİ GÖMLEK SUYU ISITICISI SEÇMELİ VOLTAJ VE VAT KİMLİKLİ YAĞLAMA YAĞI ISITICISI TERMOSTAT C131112 Rev A Page 1 of 1 Clarke Wiring Diagram, J.W. Heater – 230 VAC – C071613 English to Turkish Translator English Text Clarke Fire Protection Products, Inc. Wiring Diagram, J.W. Heater – 230 VAC Turkish Text Clarke Fire Protection Products, Inc. Kablo Tesisatı Şeması, J.W. Isıtıcı – 230 VAC Controlled Drawing This is a registered part with a third party agency for use on a product. No substitutions are allowed. Consult engineering prior to and regarding any change. Kontrollü Çizim Bu, bir üründe kullanım için üçüncü bir tarafla kayıtlı bir parçadır. Değişimlere izin verilmez. Herhangi bir değişiklik öncesinde ve değişiklikle ilgili olarak mühendisliğe başvurun. Notes: 1. 2. 3. 4. Verify heater voltage prior to connecting to power source, verify supply circuit has adequate amperage for J.W. Heater and lube oil heater when provided. There are two (2) J.W. Heaters installed on each DT2H engine and each is rated 2500 watts. The optional lube oil heater is rated 300 watts and will add this additional wattage to the power supply circuit. For 1Ø, L2 is not used. For 3Ø wiring diagram consult factory. Notlar: 1. 2. 3. 4. Güç kaynağına bağlamadan önce ısıtıcı gerilimi doğrulayın. Besleme devresinin, J.W. Isıtıcı ve sağlandığında motor yağı ısıtıcı için yeterli amper değerine sahip olduğunu doğrulayın. Her bir DT2H motorda kurulu iki (2) J.W. Isıtıcı vardır ve her biri 2500 watt derecelidir. İsteğe bağlı motor yağı ısıtıcı 300 watt derecelidir ve güç besleme devresine ek watt katacaktır. 1Ø için L2 kullanılmaz. 3Ø kablo tesisatı şeması için fabrikaya danışın. Heater System Operation Data Jacket Water Heater………………………………….Standard Wattage (Nominal)……………………..2500 (each, quantity 2) Voltage – AC, 1P……………….….……………230 (+5%, -10%) Lube Oil Heater Wattage Required option when ambient is below 40°F (4°C)…300 (quantity 1) Isıtıcı Sistemi Çalışma Verileri Jacket Water Isıtıcı…………………...........………….Standart Watt Değeri (Nominal)………………..2500 (her biri, miktar 2) Gerilim – AC, 1P….........……………………230 (+%5, -%10) Motor Yağı Isıtıcı Watt Değeri Ortam 4°C’nin altında olduğunda gerekli seçenek…300 (miktar 1) Jacket Water Heater with Voltage & Wattage Identification 1Ø VAC Power See Note 1,2,3 & 4 Line 1 Line 2 or Neutral Heating Element Optional Lube Oil Heather with Voltage & Wattage Identification (See Note 3) Thermostat Gerilim ve Watt Değerleri Tanımlı Jacket Water Isıtıcı 1Ø VAC Güç Bkz. Not 1,2,3 ve 4 Hat 1 Hat 2 veya Nötr Isıtma Elemanı Gerilim ve Watt Değerleri Tanımlı İsteğe Bağlı Motor Yağı Isıtıcı (Bkz. Not 3) Termostat C136502 RevD A B C D 4 THERMOSTAT 4 T2 T1 C2 C1 C1 E3 G HEATING ELEMENT L3 E4 C2 3 C2 E6 HEATING ELEMENT OPTIONAL LUBE OIL HEATER WITH VOLTAGE & WATTAGE IDENTIFICATION (SEE NOTE 3) E1 C1 L1 1Ø VAC POWER SEE NOTE 1, 2, 3 & 4 JACKET WATER HEATER WITH VOLTAGE & WATTAGE IDENTIFICATION 3 2 ECN# 1668 1668 2440 2473 3965 1 DWN DMP RJT RJT JCA NDD JCA APVD DATE 01APR10 21APR10 03OCT11 07SEP12 02FEB15 2 MACHINE TOLERANCE inch DECIMAL mm X. 1.5 0.06 X .X 0.8 0.03 X.XX 0.3 0.01 X.XXX 0.025 0.001 X.XXXX ANGULAR: 0.5 FABRICATION TOLERANCE inch DECIMAL mm X. 3 X .X 0.12 1.5 X.XX 0.06 ANGULAR: 1.0 THIS DRAWING AND THE INFORMATION HEREON ARE OUR PROPERTY AND MAY BE USED BY OTHERS ONLY AS AUTHORIZED BY US. UNPUBLISHED--ALL RIGHTS RESERVED UNDER THE COPYRIGHT LAWS YES NO ASSEMBLY MATERIAL ENGR DATE DRWN DT2H ENGINE N/A KKUNKLER 4/1/2010 DPOTTER CONTROLLED DRAWING SCALE NTS PART NO. NAME 1 MM [INCH] UNITS C071613 1 PAGE WIRING DIAGRAM, J.W. HEATER - 230 VAC OF 1 E REV Fire Protection Products, Inc. This is a registered part with a third party agency for use on a product. No substitutions are allowed. Consult engineering prior to and regarding any change. CONTROLLED DRAWING REQUIRED OPTION WHEN AMBIENT IS BELOW 40° F (4° C) .................300 (qty 1) LUBE OIL HEATER WATTAGE VOLTAGE - AC, 1P ...........................................................................................230 (+5%, -10%) WATTAGE (NOMINAL) .....................................................................................2500 (each, qty 2) JACKET WATER HEATER ......................................................................................STANDARD HEATER SYSTEM OPERATION DATA ADDITIONAL WATTAGE TO THE POWER SUPPLY CIRCUIT. 3. THE OPTIONAL LUBE OIL HEATER IS RATED 300 WATTS AND WILL ADD THIS EACH IS RATED 2500 WATTS. 2. THERE ARE TWO (2) J.W. HEATERS INSTALLED ON EACH DT2H ENGINE AND AND LUBE OIL HEATER WHEN PROVIDED. VERIFY SUPPLY CIRCUIT HAS ADEQUATE AMPERAGE FOR J.W. HEATER 1. VERIFY HEATER VOLTAGE PRIOR TO CONNECTING TO POWER SOURCE, NOTES: REV DESCRIPTION A ISSUED ENGINEERING DRAWING B ADDED DASHED LINES TO VAC POWER SUPPLIES C REROUTED VAC POWER SUPPLY LINES D DIAGRAM RE-WORKED FOR NEW JUNCTION BOX ASSY E GENERAL UPDATES A B C D
Benzer belgeler
C130977 NFPA-20 COOLING LOOP PIPING DETAIL.idw
Dirty Air Cleaner – in H2O (kPa)
Clean Air Cleaner – in H2O (kPa)
Maximum Allowable Temperature
(Air to Engine Inlet) – oF (oC)[5]
Lubrication System
Oil Pressure – normal – lb/in2 (kPa)
Low Oil Pr...