ME-KAL
Transkript
ME-KAL
KALiBRASYON SERTiFiKASI C.ERTIFICATE OF CALIBRATION ME-KAL Kalibrasyon KIM. Kalite Iyile§tirme Laboratuvar MOdurlOgu Karyagdl Sok. No: 14/1 06690 A.Ayrancl - ANKARA Tel: (312)4419208 Faks: (312) 4402538 Merkezi MUh" Dan., Egitim., I~ ve Dl~ Tic. Ltd. E-posta : medkal@kim~tr.com Web Sitesi : WWW.kim-tr.com laboratuv8r1 I Calibration Laborato Kalibrasyon Kalibrasyon tarihi ve veri I Date 25.04.2012 Kalibrasyonu yapan and place of calibraflon Sertifikatarihive no'su I Date of issue and no KBB Servisi I Calibration done by' Ercan DEMiR Cihaz tanlrnl J Description: Vakummetre Modell Model: imalat~1 I Manufacturer: ROCKK Cihaz sahibi I Customer: S.B KE<;:IOREN EGiTIM VE ARA:,mRMA HASTANESi / ANKARA Kullamlan kalibrasyon standardlari/Calibration Tanlm / Description Model/Model DRUCK DPI 610 BasIn<;KalibratorO(*) Sipari§ no I Order no: 4055/12 standards used (izlenebilirlikITraceability): Seri no / Serial no 61007095/2186707 Gegerlik sOres;/ Due date $ubat 14 Kalibrasyon Metodu I Calibration Method: Kalibrasyonda kullanllan cihazlann 9Ikl!}lan; NIST (National Institute of Standards), NRS (National Reference Standards) ve/veya UME (Ulusal Metroloji EnstitQsli) taraflndan realize edilmi!} birimler olup, kalibrasyonu yapllan cihazdan alman bilgiler ile klyaslanml!}t1r. OlgOm belirs;zligi %95 glivenlik seviyesi ve k=2 ortme faktoru esas allnarak hesaplanml!}tlr. / The outputs of the calibrators whic/] are basic units realized by NIST (National Institute of Standards), NRS (National Reference Standards) and/or UME (National Metrology Institute), compared with measured data. In the calculations of uncertainities confidance level is taken 95% with the coverage factor k=2. Cevre ~artlarl I Environmental conditions: S,cakllk I Ambient temperature : 23 +/- 2 °C Nem / Humidity : 50 +/- 10% SIC~kJlk dengelenme zamanl I Temp. stabilization time : 30 dak/min Tavsiye edilen gelecek kalibrasyon tarihi IRecommended recalibration before: 25.04.2013 * Kalibrasyon cihazlannln izlenebilir/igi UMS (Uzmanlar Metroloji Servisi) Uzerinden UME (Ulusaf Metroloji EnstitOsO)' ye uzanmaktadlr. / The calibration equipment are traceable by UMS Ltd. through UME (National Metrology Insfltute) ** MUhUrsOzve imzaSlz sertifikalar gegersizdir & Bu sertifika Laboratuvanmlzln onaYI olmakslzm <;ogaJtllamaz,/ Certificates without signature and seal are not valid & This certificate may not be reproduced without permission of our laboratory. KLF.01/09 Rev.No 03 Sayfa 1/2 Olt;um Raporu / Measurement Report KS-12/04/3420 Marka: Performans MEDKAL Model: ROCKK Testi / Performance - Seri No: ----- Test: KiM MOh., Dan., Egt., it; ve DI~ Tit;. Ltd. Sayfa 2/2
Benzer belgeler
ME-KAL
(National Institute of Standards) ve/veya NRS (National Reference Standards) taraflndan realize edilmi§,
birimler olup, kalibrasyonu yapilan cihazdan all nan bilgHer He k'yaslanml~tlr. Olgum belirs...
ME-KAL
Institute of Standards) ve/veya NRS (National Reference Standards) tarafrndan realize edilmi!? birimler
olup, kalibrasyonu yaprlan cihazdan alman bilgiler ile kryaslanml!~tlr. Olc;um belirsizligi %...