KALiBRASYON SERTiFiKASI CERTIFICATE OF CALIBRATION ME-KAL Kalibrasyon KiM - Kalite MOh" Dan., E-posta Web Sitesi Laboratuvar MOdurlOgu Karyagdl Sok. No: 14/1 06690 A.Ayrancl - ANKARA Tel: (312)4419208 Faks : (312) 440 25 38 Iyile~tirme Merkezi Egitim., Ie;:ve DI~ Tic. Ltd. : [email protected] : www.kim-tr.com Kalibrasyon Laboratuvan I Calibration Laboratory: Kalibrasyon tarihi veyeri I Date and place of calibration 25.05.2012 Kalibrasyonu yapan I Sertifika larihi Calibration done E. Ekrem tanlml' Description: Odyometre ELECTRONICS S.B. KE<;;iOREN HASTANESi ORBITER EGITiM VE ARA$TIRMA Tanlm 34401A Hp (Agilent) KIMO DB100 Sonometre Metodu standards cihazdan Method. Kallbrasyonda all nan bilgiler kullanllan Bundesanstalt) ile klyaslanml§tlr. clhazlann data. In the calculations ~artlarll of uncertainities Tavsiye edilen • Kalibrasyon gelecek cihazlnln kalibrasyon izlenebilirligi EnstilOsO)' ye uzanmakladlr. through UME (National •• Kalibrasyon The calibration ••• MOhorsuz Kaslm 12 Kaslm 12 zaman tarihi is traceable ve imzaslz sertifiklar signature Rev.IJo: time: recalibration ozerinden +/- 2 °C 50 +/- 10% 30 dak. / min. before: 25.05.2013 UME (Ulusal by TSE (Turkish factor k=2. Metroloji Accreditation Agency) Institute) . gegersizdir & Bu sertifJka Laboratuvanm/zln and seal are not valid 03 of ve k=2 which are basic units realized by Bundesanstalt) compared with stabilization EnstitosO) Institute olup, seviyesi level is taken 95% with the coverage IRecommended equipment birimler %95 guvenlik 23 I / Temp. TSE (TUrk Standartlan / The calibration Metrology NIST (National realize edilmi§ belirsizligi cihazlnln izlenebilirligi KIMO Ozerinden NIST (National Institute of Standards)'e uzanmaktadlr. equipment are traceable by KIMO through NIST (National Institute of Standards) . Certificates without of our laboratory. KL.F.01/09 confidance suresi / Due date E169117 Environmental conditions: Sicaklik / Ambient temperature Nem / Humidity Sicakhk dengelenme Gegerlik US 36130495 glkl§llan; taraflndan Olgum ortme faktoru esas allnarak hesaplanml§tlr. / The outputs of the calibrators NIST (National Institute of Standarts) and/or PTB (Physikalish-Technische Cevre tizlenebilirliklTraceabilitv\: Seri no / Serial no Dijital Multimetre(*) PTB (Physikalish~Technische yapllan used / Description (**) I Calibration veNeya 922 4055/12 standardlan/Calibration Model/Madel measured ozeAN Sipari~ no I Order no: I ANKARA kalibrasvon Kalibrasyon and no: KS-12/05/2467 99735 MADSEN Standarts) of issue Modell Model: Cihaz sahibi J Customer: kalibrasyonu Date Seri no I Serial no: imalat~1I Manufacturer: Kullanllan I Sorumlu I Responsible by: Burak SOYSAl. Cihaz ve no'su 25.05.2012 Odyoloji & This certificate onaYI olmaks/zln may not be reproduced I gogaltllamaz./ without permission Sayfa 1/3 bl~i.imRaporu I Measurement Report KS-12/05/2467 Marka: MADSEN ELECTRONICS Model: ORBITER 922 Seri No: 99735 i§itme Seviye Test; I ) SAG KULAK bl~i.imKademesi Ger~ek Tone ve Warble Deger I Real Value I Range (dB) GorUlen Display (dB) 29 39 49 59 69 79 30 40 50 60 70 80 Modu Deger / Value Fark I Difference (dB) -1 -1 -1 -1 -1 -1 II) SOL KULAK bl~i.imKademesi Ger~ek Tone ve Warble Deger I Real Value / Range (dB) 30 40 50 60 Modu 70 80 MEDKAL KiM Mlih., Dan., Egt., i~ve DI~ TiC. Ltd. Gori.ilen Display Deger / Value (dB) 28 38 48 58 68 79 Fark I Difference (dB) -2 -2 -2 -2 -2 -1 Sayfa 2/3 Oleum Raporu I Measurement Report KS-12/05/2467 Marka: MADSEN III ) SAG KULAK Oleum ELECTRONICS Kademesi Gereek KULAK Hz MEDKAL Deger I Display (Hz) Seri No: Value 99735 Fark I Difference (Hz) (Hz) 250 500 750 1000 2000 3000 4000 5000 250 500 750 1001 2002 3003 4004 5005 0 0 0 1 2 3 4 5 (Frakans) OleOm Kademesi I Range GorUlen Deger I Real Value Hz I SOL ORBITER 922 (Frekans) I Range IV Model: Gereek Deger I Real Value (Hz) 250 500 750 1000 2000 3000 4000 5000 KiM MOh., Dan., Egt., ic ve DI~ TiC. Ltd. GorOlen Display Deger I Value (Hz) 250 500 750 1001 2001 3003 4004 5005 Fark I Difference (Hz) 0 0 0 1 1 3 4 5 Sayla 3/3
Benzer belgeler
ME-KAL
(National Institute of Standards) ve/veya NRS (National Reference Standards) taraflndan realize edilmi§,
birimler olup, kalibrasyonu yapilan cihazdan all nan bilgHer He k'yaslanml~tlr. Olgum belirs...
ME-KAL
taraflndan realize edilmi!} birimler olup, kalibrasyonu yapllan cihazdan alman bilgiler ile klyaslanml!}t1r.
OlgOm belirs;zligi %95 glivenlik seviyesi ve k=2 ortme faktoru esas allnarak hesaplanml!...
ME-KAL
Standards), compared with measured data. In the calculations of uncertainities confidance level is taken
95% with the coverage factor k=2.
Cevre §artlarll
TORKAK
KIMO Ozerinden NIST (National Institute of Standards)'e
uzanmaktadlr.
equipment are traceable by KIMO through NIST (National Institute of Standards) .