thermostatic air vent for steam
Transkript
thermostatic air vent for steam
SDS U3608-08 THERMOSTATIC AIR VENT FOR STEAM MODEL LA21 STAINLESS STEEL ALL STAINLESS STEEL THERMOSTATIC AIR VENT Features Compact all stainless steel air vent with fail-open feature for steam, for vertical installation. 1. Vents air automatically until close-tosteam temperature. 2. Compact yet with high capacity. 3. Reacts immediately to changes in operating conditions. 4. Withstands superheat and water hammer. 5. Easy to maintain and easy to clean. 6. Hardened stainless steel valve seat. 7. Tight shut-off. Model Connection Size Maximum Operating Pressure (barg) PMO Minimum Operating Pressure (barg) Maximum Operating Temperature (°C) TMO Subcooling of X-element Fill (°C) Type of X-element Applicable Fluid* LA21 Screwed 1⁄2” 21 0.1 see graph at right up to 22 T Steam * Do not use for toxic, flammable or otherwise hazardous fluids. PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure (barg) PMA: 63 Maximum Allowable Temperature (°C) TMA: 425 CAUTION No. q w e r t y u Description Body Cover X-element Valve Seat Screen Nameplate Spring Clip * Equivalent materials To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. Material Stainless Steel A351 Gr.CF8 Stainless Steel A351 Gr.CF8 Stainless Steel Stainless Steel SUS630 Stainless Steel SUS304 Stainless Steel SUS304 Stainless Steel SUS304 DIN* 1.4312 1.4312 — 1.4542 1.4301 1.4301 1.4301 ASTM/AISI* — — — AISI630 AISI304 AISI304 AISI304 Temperature (°C) Specifications 235°C 250 220 200 Saturated Steam Curve 150 100 0 5 10 15 20 21 Pressure (barg) 1 bar = 0.1 MPa Dimensions ¡LA21 Screwed LA21 Screwed* Size L φW Weight (kg) 1⁄2” 55 47 0.4 (mm) L W * BSP, DIN 2999, other standards available Air Venting Capacity 2100 Air Venting Capacity (ℓ/min) 2000 1000 700 500 300 200 100 70 50 0.1 0.3 0.5 1 2 3 Differential Pressure (bar) 5 10 20 21 1 bar = 0.1 MPa 1. Differential Pressure is the difference between the inlet and outlet pressure of the air vent. 2. Capacities are equivalent capacities of air at 20°C and atmospheric pressure. SDS U3608-08 Rev. 8/2013 Products for intended use only. Specifications subject to change without notice.
Benzer belgeler
model lv13l brass balanced pressure thermostatic steam trap
X-element
X-element Guide
Spring Clip
Screen
Cover Gasket
Nameplate