PHASE FAILURE DEVICES PHASE SEQUENCE and THERMISTOR DEVICES FR-02 / PT-01 MK-01 / 01P, MKC-01 / 01P MK-01 / MK-01P, MKC-01 / 01P FR-02 General General One of the common faults faced in industrial plants is over-heating and burning of 3 phase motors due to the phase failure. Thermicmagnetic device which is an essential element in motor protection is generally too slow due to both its electro-mechanical structure and the use of high current setting range to assure demarrage without tripping. Being designed to eliminate the above disadvantages, MK-01, MK-01P and MKC-01, MKC-01P Phase Failure Devices react within 0.2 sec. (fixed) against the following faults and take the motor out of service. FR-02 is an electronic device monitoring the L1, L2, L3 phase sequence. Operation Principles FR-02 Phase Sequence Device is developed to be used in three-phase systems where correct phase sequence is important. If the input L1, L2 and L3 phases are in correct sequence, the LED on the front panel remains ON and the internal relay is energized. When the phase sequence is wrong, the LED turns OFF and output relay is inactive. In this case, interchanging two phases will be sufficient to solve the problem. General applications in which FR-02 phase sequence device is used, are vessel pumping systems, air compressors, and elevators. The unexpected false rotating direction of motors used with these systems can cause injury to persons and damage the property. 1. PTC Protection (Available only in MK-01P and MKC-01P) When the coil temperature in motors exceeds Tc, the limit temperature of PTC, the output relay switches OFF immediately. This feature is included MK-01P and MKC-01P. See Fig.1 for typical resistance of PTC vs temperature characteristics for three different switching temperatures (110 0C, 120 0C, 130 0C) normally, PT-110 is used and it can be changed upon request. See Fig. 1. Technical Data Rated Voltage (Un) : 230 VAC 3 Phase + Neutral: 4 Wires Star Connection Operating Range : (0.9-1.1) x Un Rated Frequence : 50/60 Hz. Output Contact : 1 C/O with 5A, 1250 VA, Cosj=1 Warning Led : LED normally ON Ambient Temperature: -5 0C to +50 0C Dimensions : Type PK 10 Protection Class : IP 20 Installation : Surface mounting or on the mounting rails. Weight : 0.3 kg. 2. Voltage Unbalance (Not adjustable) When the neutral-phase voltage unbalance is greater than 20% (fixed), the output relay is switched off within 0.2 seconds. See Fig.2. Function Diagram Fixed Unbalance Hysterisis L1 L2 Connection Diagram for FR-02 L3 1 N L1 Rated Voltage (Un) L2 : 3 Phase and Neutral 230 VAC 4 Wires, Star Connection Operating Range : (0.9-1.1) x Un Rated Frequency : 50/60 Hz. Output Contacts : 1 C/O with, 5A, 1250 VA, Cosj=1 (for MK-01P, type PK10) 1 C/O with, 8A, 2000 VA, Cosj=1 Warning Led : LED Output : Normally ON (turns OFF on Faults) Tripping Time : 0.2 s Ambient Temperature : -5 °C ; +50 °C Protection Class : IP 20 Dimensions : Type PK 10 (MK-01P) Type PK 21 (MK-01) Type PK 25 (MKC-01 / MKC-01P) Installation : Surface mounting or on the mounting rails. Weight : 0.1 kg. (for MK-01 and MKC-01) 0.25 kg. (for MK-01P and MKC-01P) Operation Principles PT-01 Thermistor Device is developed to be used for PTC protection. When the coil temperature in motors exceeds Tc, the limit temperature of PTC, the output relay switches OFF immediately. See Fig.1 for typical resistance of PTC vs temperature characteristics for three different switching temperatures (110 0C, 120 0C, 130 0C) Normally, PT-110 is used and it can be changed upon request. See Fig.1. As seen from Fig.1, the PTC resistance is smaller than 100 W when T<Tc-50 and greater than 10K when T>Tc+50 . Technical Data * 1 2 3 PTC T1 MKC-01 MKC-01P Stop L1 L2 L3 C1 System to be protected PT-01 is an electronic device monitoring the motor temperature. 1 MK-01 MK-01P N General * N L3 L3 PT-01 Connection Diagram for MKC-01 / 01P Connection Diagram for MK-01 / 01P T1 L2 N Technical Data 2 L1 TD = Tripping Time TD 3 3 FR-02 Output Relay TD 2 Stop Rated Voltage (Un) : 230 VAC Operating Range : (0.9-1.1) x Un Rated Frequence : 50/60 Hz. Output Contact : 1 C/O with, 5A, 1250 VA, Cosj=1 Warning Led : LED Output, normally ON (OFF for any fault). Ambient Temperature : -5 0C to +50 0C Dimensions : Type PK 10, Type PK 28 Protection Class : IP 20 Installation : Surface mounting or on the mounting rails. Weight : 0.3 kg. T1 C1 Start C1 PTC N N L1 L2 L3 T1 C1 Connection Diagram Start N L1 L2 M L3 3~ PTC L1 N L2 M L3 3~ * * N * : PTC output terminals are available in MK-01P and MKC-01P. If PTC is not used in MK-01P and MKC-01P, by any reason, PTC terminals should be short circuited. 3 Stop N Temperature ( C) Figure 1. VL3 VL2 N N L2 3~ L3 14 M 3~ L3 TYPE PK 10 Dimensions Failure to follow those instructions will result in death or serious injury. Disconnect all power before working on equipment. When the device is connected to the network, do not remove the front panel. Do not try to clean the device with solvent or the like. Only clean the device with a dried cloth. Verify correct terminal connections when wiring. Electrical equipment should be serviced only by your compedent seller. L2 M N Precautions For Installation and Safe Use TYPE PK28 N 50 74 48 mm 58 mm 34 mm 80 44 TYPE PK 21 Mount device to the panel. PTC L1 L1 Figure 2. T1 C1 PTC No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences arising out of the use of this material. A2905 / Rev.7 35 80 Ø4.0 60 TYPE PK 10 35 32 mm 48 mm TYPE PK25 61.8 mm 0 L Start Start VRef = 230 VAC N C1 45.4 mm 10 20 40 60 80 100 120 140160 180 200 T1 C1 3 90 mm VL2 100 VRef C1 2 PT-01 35.3 mm R(W) 1k x 100 Stop L 1 PTC 45 mm 62 mm Assimetry % = VL1 - VL2 90 mm VL1 T1 110 110 120 130 VL1 10k T1 T2 1 PT-01 35 mm 100k 2 PTC T1 35 mm 59.7 mm TYPE PK28 36 mm MOTOR (FAZ) KORUMA RÖLELERÝ FAZ SIRASI ve TERMÝSTÖR RÖLELERÝ FR-02 / PT-01 MK-01 / 01P, MKC-01 / 01P MK-01/ MK-01P, MKC-01 / 01P FR-02 Genel Genel Sanayi tesislerimizde yaygýn olarak kullanýlan elektrik motorlarýnýn iki faza kalarak aþýrý ýsýnmasý ve yanmasý sýkça karþýlaþýlan arýza kaynaklarýndan biridir. Motor korumasýnda sýk kullanýlan Termik Manyetik Röle gerek elektro-mekanik yapýsý, gerekse demeraj akýmýnýn karþýlanabilmesi için akým ayarýnýn yüksek tutulmasý nedeniyle, koruma iþleminde yetersiz kalmaktadýr. Bu olumsuz etkileri ortadan kaldýracak þekilde tasarlanmýþ bulunan MK-01, MK-01P ve MKC-01, MKC-01P motor koruma röleleri aþa¤ýdaki koruma fonksiyonlarýný yerine getirir. FR-02 L1, L2, L3 fazlarýnýn sýrasýný kontrol edir. Kullaným ve Çalýþma Prensibi Giriþine gelen L1, L2 ve L3 fazlarý do¤ru sýralandý¤ý takdirde çýkýþ veren FR-02 faz sýrasý rölesi, ters faz olayýnýn hayati önem taþýdý¤ý üç fazlý sistemlerin korunmasýnda kullanýlmak üzere geliþtirilmiþtir. E¤er giriþteki L1, L2 ve L3 fazlarý do¤ru sýrada ise röle üzerindeki LED yanýk ve çýkýþ rölesi çekmiþ konumdadýr. E¤er fazlar ters ise LED söner ve çýkýþ rölesi býrakýr. Bu durumda iki fazýn ba¤lantýlarýný de¤iþtirmek yeterli olacaktýr. Genelde FR-02 faz sýrasý rölesinin kullanýldý¤ý alanlar, gemi pompa sistemleri, hava kompresörleri ve asansörlerdir. Bu sistemlerde kullanýlan motorlarýn ters yönde dönmesi kiþisel ve maddi hasarlara yol açabilir. 1. PTC Korumasý (Sadece MK-01P ve MKC-01P tipinde) Motor sargý sýcaklý¤ý PTCnin sýcaklýk sýnýr de¤erini aþarsa motor gecikmesiz olarak devreden çýkartýlýr. Bu özellik MK-01P ve MKC-01Pde yer almaktadýr. De¤iþik sýcaklýk sýnýr de¤erlerine (110 0C, 120 0C, 130 0C) sahip üç PTCnin direnç-sýcaklýk de¤iþimleri Þekil 1de verilmektedir. Teknik Bilgi Ýþletme Gerilimi (Un) Ýþletme Aralý¤ý Ýþletme Frekansý Kontak Tipi Uyarý LEDi 2. Gerilim Dengesizli¤i (Ayarlanamaz) Nötr-Faz arasý gerilim dengesizli¤i %20lik sabit de¤erden fazla oldu¤u anda çýkýþ rölesi 0.2 sn içinde motoru devreden çýkarýr. Þekil 2ye bakýnýz. Üç fazlý sistemlerde gerilim dengesizli¤i (asimetri) yüklerin fazlara dengesiz ba¤lanmasý sonucu oluþur. Gerilim dengesizli¤i motor sargý sýcaklý¤ýnýn belli bir miktar artmasýna ve dolayýsýyla motor gücünün düþmesine neden olur. : 220 VAC 3 faz + 1 nötr: yýldýz ba¤lantý : (0.9-1.1) x Un : 50/60 Hz. : 1 C/O, 5A, 1250 VA, Cosj=1 : Röle çekili iken yanar, röle býraktý¤ý zaman (hatalý durumlarda) söner : -5 0C ; +50 0C : Tip PK 10 : IP 20 : Pano içine dikey veya klemens rayýna. : 0.5 kg. Ortam Sýcaklý¤ý Boyutlar Koruma Sýnýfý Ba¤lantý Þekli A¤ýrlýk Fonksiyon Diyagramý Sabit Dengesizlik Histerisis FR-02 için Ba¤lantý Þemasý L1 1 L2 2 3 FR-02 L3 N L1 L2 L3 N Çýkýþ Rölesi L1 L2 TD = Zaman Gecikmesi MK-01 / 01P Ýçin Ba¤lantý Þemasý Kullaným ve Çalýþma Prensibi PT-01 termistör rölesi PTC korumasý için geliþtirilmiþtir. Motor sargý sýcaklý¤ý PTCnin sýcaklýk sýnýr de¤erini (Tc) aþarsa motor gecikmesiz olarak devreden çýkartýlýr. De¤iþik sýcaklýk sýnýr de¤erlerine (110 0C, 120 0C, 130 0C) sahip üç PTCnin direnç - sýcaklýk de¤iþimleri þekil 1de verilmektedir. Normalde 110 0Clik PTC kullanýlmasýna ra¤men istek üzerine bu de¤iþtirilebilir. Þekilden görüldü¤ü gibi PTC direnci 0 T<Tc-5 iken 100 Wdan küçük fakat T>Tc+50 iken 10Kdan büyüktür. Teknik Bilgi Ýþletme Gerilimi (Un) Ýþletme Aralý¤ý Ýþletme Frekansý Kontak Tipi Uyarý LEDleri MKC-01 / 01P Ýçin Ba¤lantý Þemasý * PTC MK-01 MK-01P Stop T1 N C1 N L1 L2 L3 T1 C1 3 Start L2 M L3 3~ N * : PTC terminalleri MK-01P ve MKC-01Pde mevcuttur. PTC kullanýlmadý¤ýnda, PTC terminalleri kýsa devre edilmelidir. N PTC M L3 3~ T1 PT-01 Stop N Stop 2 3 PT-01 N L 1 PTC L N 100k C1 10k Asimetri % = Sýcaklýk ( C) Þekil 1. VL1 - VL2 VRef x 100 VL2 N L2 M 3~ M 3~ L3 TÝP PK 10 TÝP PK28 N Boyutlar 50 74 48 mm 58 mm 34 mm Þekil 2. 14 Güvenli Kullaným ve Kurulum Ýçin Uyarýlar Aþaðýdaki talimatlara uyulmamasý halinde yaralanma veya ölümle sonuçlanabilecek durumlar ortaya çýkabilir. Cihaz üzerindeki herhangi bir iþlemden önce tüm besleme gerilimlerini kesiniz. Cihaz þebekeye baðlý iken ön paneli çýkarmayýnýz. Cihazý solvent veya benzeri maddelerle temizlemeyiniz. Cihazý temizlemek için sadece kuru bez kullanýnýz. Cihazý çalýþtýrmadan önce baðlantýlarýnýn doðru olduðunu kontrol ediniz. Cihazý panoya monte ediniz. Cihazýnýzdaki herhangi bir sorunda yetkili satýcýnýzla temas kurunuz. Yukarýdaki önlemlerin uygulanmamasý sonucu doðabilecek istenmeyen durumlardan üretici firma hiç bir þekilde sorumlu tutulamaz. PTC L1 L2 L3 VRef = 220 VAC T1 C1 PTC L1 N VL2 0 C1 Start N R(W) VL3 C1 Start VL1 100 T1 80 110 120 130 VL1 10 20 40 60 80 100 120 140160 180 200 1 PTC T1 L1 L2 2 T1 T2 110 L1 1k * * PTC 44 TÝP PK 21 35 80 Ø4.0 60 TÝP PK 10 35 32 mm 48 mm 35 mm TÝP PK25 Bu ürün, 30.05.2008 tarih ve 26891 sayýlý resmi gazetede yayýnlanan EEE Yönetmeliðinin Madde 2 ve Ek-1A madde 9 kapsamýndadýr. A2905 / Rev.7 61.8 mm C1 Start 45.4 mm C1 PT-01 için Ba¤lantý Þemasý MKC-01 MKC-01P T1 L3 90 mm L2 35.3 mm L1 45 mm 62 mm N 90 mm T1 Stop : 220 VAC : (0.9-1.1) x Un : 50/60 Hz. : 1 C/O, 5A, 1250 VA, Cosj=1 : OUT LEDi: Röle çekili iken yanar, röle býraktý¤ý zaman (hatalý durumlarda) söner. : -5 0C ; +50 0C : IP 20 : Tip PK 10, Tip PK 28 : Pano içine dikey veya klemens rayýna. : 0.3 kg. Ortam Sýcaklý¤ý Koruma Sýnýfý Boyutlar Ba¤lantý Þekli A¤ýrlýk 1 2 3 1 Korunacak Sistem PT-01 motor sargý sýcaklý¤ýna karþý kullanýlan bir termistör rölesidir. * 2 N Genel Ýþletme Gerilimi (Un) : 220 VAC 3 faz + nötr, yýldýz ba¤lantý : (0.9-1.1) x Un Ýþletme Aralý¤ý : 50/60 Hz. Ýþletme Frekansý Kontak Tipi : 1 C/O, 5A, 1250 VA, Cosj=1 (MK-01P için, tip PK10) 1 C/O, 8A, 2000 VA, Cosj=1 Uyarý LEDleri : OUT LEDi: Röle çekili iken yanar, röle býraktý¤ý zaman (hatalý durumlarda) söner. Gecikme Zamaný : 0.2 sn 0 0 Ortam Sýcaklý¤ý : -5 C ; +50 C Koruma Sýnýfý : IP 20 Boyutlar : Tip PK 10 (MK-01P) Tip PK 21 (MK-01) Tip PK 25 (MKC-01 / MKC-01P) Ba¤lantý Þekli : Pano içine dikey veya klemens rayýna. A¤ýrlýk : 0.1 kg. (MK-01 ve MKC-01 için) 0.25 kg. (MK-01P ve MKC-01P için) 3 L3 PT-01 Teknik Bilgi 35 mm TD TD 59.7 mm TÝP PK28 36 mm
Benzer belgeler
MOTOR (FAZ) KORUMA ve FAZ SIRASI RÖLELERİ
Faz-Nötr aras gerilim dengesizli¤i (sabit) %40tan fazla oldu¤u anda çkþ rölesi
motor (faz) koruma röleleri
Aþaðýdaki talimatlara uyulmamasý halinde yaralanma veya ölümle sonuçlanabilecek
durumlar ortaya çýkabilir.
Cihaz üzerindeki herhangi bir iþlemden önce tüm besleme gerilimlerini kesiniz.
Cihaz þebek...
GKRC-02, GKRC-02F, GKRC-03, GKRC-03F, GKRC
Yukarýdaki önlemlerin uygulanmamasý sonucu doðabilecek istenmeyen
durumlardan üretici firma hiç bir þekilde sorumlu tutulamaz.
Delay
MKC-03_04_A4946 Rev.1_A4947_rev_2_PK28.FH9
PRECAUTIONS FOR INSTALLATION AND SAFE USE
Failure to follow those instructions will result in death or serious injury.
Disconnect all power before working on equipment.
When the device is connected...
AŞIRI / DÜŞÜK AKIM KORUMA RÖLELERİ
: Type PK 25 and PK 28
: Surface mounting or on the mounting rails.
: 0.3 kg
MKC05-05P - 06-06P - FR-02 TR EN A5049 R4.FH9
protection is generally too slow to assure
demurrage without tripping due to both its
electromechanical structure and the use of high current setting range.MKC-05-05P,
MKC-06-06P and FR-02 Motor Pr...