motor (faz) koruma röleleri
Transkript
MOTOR (FAZ) KORUMA RÖLELERÝ MKC-01, MKS-01, MKC-03, MKC-03P, MKS-03, MKC-04 Ba¤lant› Þemalar› Genel Sanayi tesislerimizde yayg›n olarak kullan›lan elektrik motorlar›n›n iki faza kalarak aþ›r› ›s›nmas› ve yanmas› s›kça karþ›laþ›lan ar›za kaynaklar›ndan biridir. Motor korumas›nda s›kça kullan›lan “termikmanyetik röle” gerek elektro-mekanik yap›s›, gerekse demeraj ak›m›n›n karþ›lanabilmesi için ak›m ayar›n›n yüksek tutulmas› nedeniyle, koruma iþleminde yetersiz kalmaktad›r. Bu olumsuz etkileri ortadan kald›racak þekilde tasarlanm›þ olan “nötr’lü MKC-01, MKS-01, MKC-03, MKC-03P, MKS-03” ve “nötr’süz MKC-04” Motor Koruma Röleleri aþa¤›daki koruma fonksiyonlar›n› yerine getirir. 1- Gerilim Dengesizli¤i (Ayarlanamaz) 12 3 T1 MKC-01 MKC-03 Stop T1 L2 N L3 MKS-01 MKS-03 MKC-04 Stop C1 MKC-04’lerde nötr ba¤lant›s› yoktur. Faz-Nötr aras› gerilim dengesizli¤i: MKC-01, MKS-01 için (sabit) %20’den fazla MKC-03, MKC-03P, MKS-03, MKC-04 için (sabit) %40’dan fazla oldu¤u anda ç›k›þ rölesi motoru devreden ç›kart›r. 12 3 N L1 Start L2 T1 C1 L3 C1 Start N L1 L2 L3 T1 C1 M L1 L3 3 ~ L2 N L3 M 3~ PK 25 PTC T1 Stop C1 Start N L1 L2 L3 T1 C1 C1 N Start L1 L2 M L3 3~ N L1 L2 L3 T1 C1 N PTC L1 L2 M L3 3~ N PK 28 Sabit Dengesizlik De¤eri Histerisis L1 L2 L3 Yanl›þ Faz S›ras› Ç›k›þ Rölesi (MKC-01, MKS-01) Ç›k›þ Rölesi (MKC-03, MKC-03P, MKS-03, MKC-04) TD = Zaman Gecikmesi Güvenli Kullaným ve Kurulum Ýçin Uyarýlar Boyutlar 23mm 35mm 19mm Aþaðýdaki talimatlara uyulmamasý halinde yaralanma veya ölümle sonuçlanabilecek durumlar ortaya çýkabilir. Cihaz üzerindeki herhangi bir iþlemden önce tüm besleme gerilimlerini kesiniz. Cihaz þebekeye baðlý iken ön paneli çýkarmayýnýz. Cihazý solvent veya benzeri maddelerle temizlemeyiniz. Cihazý temizlemek için sadece kuru bez kullanýnýz. Cihazý çalýþtýrmadan önce baðlantýlarýnýn doðru olduðunu kontrol ediniz. Cihazý panoya monte ediniz. Cihazýnýzdaki herhangi bir sorunda yetkili satýcýnýzla temas kurunuz. Yukarýdaki önlemlerin uygulanmamasý sonucu doðabilecek istenmeyen durumlardan üretici firma hiç bir þekilde sorumlu tutulamaz. TiP PK22 90mm Fonksiyon Diyagram› 61mm Faz s›ras›n›n ters oldu¤u durumlarda (yani L1, L2, L3, saat yönünde de¤il ise) motor devreye al›nmaz. Herhangi bir nedenle faz s›ras› bozulursa motor gecikmesiz olarak devreden ç›kar›l›r. Ýþletme Gerilimi (Un) : Lütfen cihaz etiketlerine bakýnýz. : 3 faz ve nötr 220-230 VAC 4 kablo y›ld›z ba¤lant› (MKC-01, MKC-03, MKC-03P, MKS-01, MKS-03) : 3 faz 380 VAC 3 kablo üçgen ba¤lant› (MKC-04) : 3 faz 220 V AC 3 kablo üçgen baðlantý (MKC-04) : (0.9-1.1) x Un (MKC-04, MKC-03P) Ýþletme Aralýðý (0.8-1.2) x Un (MKC-01, MKC-03, MKS-01, MKS-03) : 50/60 Hz. Ýþletme Frekansý : 1 C/O, 8A, 250 V AC, 2000 VA, Cosϕ=1 (MKC-01, MKC-03, MKC-03P, MKC-04) Kontak Tipi 1 NO, 8A, 250 V AC, 2000 VA, Cosϕ=1 (MKS-01, MKS-03) : OUT LED’i : Röle çekili iken yanar, röle b›rakt›¤› Uyarý LED’leri zaman (hatal› durumunda) söner ON LED’i : Besleme gerilimi varsa yanar (MKC-01, MKC-03, MKC-03P) : 0.2 sn Gecikme Zamaný : -20 °C ; +55 °C Ortam Sýcaklýðý Depolama Sýcaklýðý :-40 °C ; +70 °C : IP 20 Koruma Sýnýfý : Tip PK 22 (MKS-01, MKS-03) Boyutlar Tip PK 25 (MKC-01, MKC-03, MKC-04) Tip PK 28 ((MKC-01, MKC-03, MKC-03P) : Pano içine dikey veya klemens ray›na. Baðlantý Þekli Panoya vida ile montaj adaptör parçasýyla mümkündür. (Bakýnýz Þekil 1) : 0.08 kg. (MKS-01, MKS-03) Aðýrlýk 0.1 kg. (MKC-01, MKC-03) 0.2 kg. (MKC-04, MKC-03P) 45mm VRef = 220 VAC 2. Faz s›ras› (MKC-03, MKC-03P, MKS-03, MKC-04) TD MKC-03P Teknik Bilgi x 100 Gerilim dengesizli¤i motor sarg› s›cakl›¤›n›n belli bir miktar artmas›na ve dolay›s›yle motor gücünün düþmesine neden olur. TD 1 2 3 Stop PK 28 VL2 3~ N PK 22 MKC-01 MKC-03 VL1 V’L2 M L3 PK 25 N Asimetri % = L2 1 2 3 Faz yokluðu veya herhangi bir sebepten oluþabilecek faz-nötr arasý gerilim dengesizliði cihaz için belirlenen asimetri deðerinden küçükse çýkýþ rölesi çekilidir. Eðer gerilim dengesizliði cihazýn asimetri deðerini aþarsa çýkýþ rölesi býrakýr ve motor devre dýþý kalýr. Uygulamalarýnýzda; motorun iki faza kalmasý esnasýnda motorun diðer sargýlarýndan indüklenen gerilim deðerini de göz önünde bulundurarak uygun cihazý kullanýnýz. V’L1 - V’L2 VRef T1 C1 2 L1 L2 T1 V’L1 1 N L1 Üç fazlý sistemlerde gerilim dengesizliði (asimetri); Yüklerin fazlara dengesiz baðlanmasý sonucu oluþabileceði gibi, Üç fazlý motorlarda fazlardan birinin kesilmesi durumunda da oluþur. Bu durumda kesilen faza ait motor sargý ucunda, motorun diðer sargýlarý üzerinden indüklenerek dönen gerilim görülür. Bu gerilim deðeri motorun cinsine ve yük durumuna göre deðiþir. VL3 L1 N 12mm Þekil 1 28mm 19mm 48mm 58mm 48 mm 58 mm 32 mm 61.8 mm TiP PK28 45.4 mm 35.3 mm 90 mm 45 mm 62 mm TiP PK25 90 mm 34 mm 35 mm 3- PTC korumasý (MKC-03P) 100k Motor sargý sýcaklý¤ý PTC’nin sýcaklýk sýnýr de¤erini aþarsa motor geçikmesiz olarak devreden çýkartýlýr. Cihazýn rölesi 10k býrakýr, Röle LED’i söner. 1k Bu özellik sadece MKC-03P’de yer almaktadýr.De¤iþik sýcaklýk sýnýr de¤erlerine (110 oC, 120 oC, 130 oC ) sahip üç PTC’nin direnç - sýcaklýk de¤iþimleri yandaki þekilde 100 verilmektedir. PTC korumasý olan bir cihazda PTC korumasý devre dýþý býrakýlmak 10 istenirse; cihaz üzerindeki PTC uçlarý 20 40 60 80 100 120 140160 180 200 kýsa devre yapýlmalýdýr Sýcaklýk (0C) 35 mm 48 mm 59.7 mm “Bu ürün, 30.05.2008 tarih ve 26891 sayýlý resmi gazetede yayýnlanan EEE Yönetmeliðinin Madde 2 ve Ek-1A madde 9 kapsamýndadýr.” A4908 / Rev.5 36 mm PHASE FAILURE PROTECTION DEVICES MKC-01, MKS-01, MKC-03, MKC-03P, MKS-03, MKC-04 General Connection Diagram One of the common faults faced in industrial plants is over-heating and burning of 3 phase motors due to the phase failure. “Thermic-magnetic device” which is an essential element in motor protection is generally too slow due to both its electromechanical structure and the use of high current setting range to assure demarrage without tripping. Being designed to eliminate the above disadvantages, MKC-01, MKC-03 and MKC-03P Phase Failure Devices react within 0.2 seconds (fixed) against the following faults and take the motor out of service. 12 3 T1 MKC-01 MKC-03 Stop 1. Voltage Unbalance (Not Adjustable) Start T1 L2 N L3 MKS-01 MKS-03 MKC-04 Stop C1 MKC-01, MKC-03 and MKC-03P have neutral connection. Unbalanced voltage for Phase-Neutral (fixed). When the value exceeds the 40% for MKC-03, MKC-03P and MKC-04 or 20% for MKC-01 and MKS-01 output relay switches-off the motor. Unbalanced voltage may occured when; The mains are loaded with unbalanced distribution, One of the 3-phase of motor has lost. In this case, some amount of voltage which produced by other phases will be inducted on the lost phase. Amount of this value depends on both the motor type and amount of load. Output relay is activated when a phase has lost or an unbalanced phase-neutral value, which is occured with any reason, is smaller than the Asymetrical value which is defined for the device. If this unbalanced voltage exceeds the adjusted Asymetrical value, output will release itself and motor will be Switched-off. In Applications; a proper device must be used regarding to the inducted voltage value in two-phase which are remained after the other one has lost. 12 3 N L1 L2 T1 C1 L3 C1 Start N L1 L2 L3 T1 C1 L1 1 T1 C1 2 N N L1 L1 L2 M L1 L3 3~ L2 M L3 3~ N PK 25 L2 M L3 3~ N PK 25 PK 22 1 2 3 PTC T1 MKC-01 MKC-03 T1 Stop 1 2 3 MKC-03P Stop C1 VL1 Asymmetry % = V’L1 V’L2 V’L1 - V’L2 VRef Start x 100 C1 N Start L2 M L3 3~ N L1 L2 L3 T1 C1 N PTC L1 N L2 M L3 3~ N VRef = 220 VAC PK 28 PK 28 Technical Data Rated Voltage (Un) : Please look at labels on the device. : 3 phase and neutral 220-230 VAC 4 Wires Star Connection (MKC-01, MKC-03, MKC-03P, MKS-01, MKS-03) : 3 Phase 380 VAC 3 Wires Delta Connection (MKC-04) : 3 Phase 220 V AC 3 Wires Delta Connection (MKC-04) Operating Range : (0.9-1.1) x Un (MKC-04, MKC-03P) (0.8-1.2) x Un (MKC-01, MKC-03, MKS-01, MKS-03) Rated Frequency : 50/60 Hz. Output Contacts : 1 C/O, 8A, 250 V AC, 2000 VA, Cosϕ=1 (MKC-01, MKC-03, MKC-03P, MKC-04) 1 NO, 8A, 250 V AC, 2000 VA, Cosϕ=1 (MKS-01, MKS-03) Warning LEDs : LED output, normally ON (OFF for any fault) ON LED’i: On when supply voltage is present (MKC-01, MKC-03, MKC-03P) : 0.2 sec. Tripping Time Ambient Temperature : -20 °C ; +55 °C Storage Temperature :-40 °C ; +70 °C : IP 20 Protection Class : Typ PK 22 (MKS-01, MKS-03) Dimension Typ PK 25 (MKC-01, MKC-03, MKC-04) Typ PK 28 ((MKC-01, MKC-03, MKC-03P) : Surface mounting or on the mounting rails. Installation Panel mounting with screws and adapter is possible. (Refer to Figure 1) : 0.08 kg. (MKS-01, MKS-03) Weight 0.1 kg. (MKC-01, MKC-03) 0.2 kg. (MKC-04, MKC-03P) The voltage asymmetry causes the rise in motor temperature and a reduction of the rated motor power. 2. Phase Sequence (MKC-03, MKC-03P, MKS-03, MKC-04) When the phase sequence is correct (L1, L2, L3 in clockwise direction) the output relay is activated; however, if the sequence is changed by any reason, the output relay switches OFF immediately. Function Diagram Fixed unbalance value Hysterisis L1 L2 L3 Wrong Phases Sequence Output Relay (MKC-01) Output Relay (MKC-03, MKC-03P) TD = Tripping Time Precautions For Installation and Safe Use Failure to follow those instructions will result in death or serious injury. Disconnect all power before working on equipment. When the device is connected to the network, do not remove the front panel. Do not try to clean the device with solvent or the like. Only clean the device with a dried cloth. Verify correct terminal connections when wiring. Electrical equipment should be serviced only by your compedent seller. Mount device to the panel. No responsibility is assured by the manufacturer or any of its subsidiaries for any consequences arising out of the use of this material. Dimensions 35mm 19mm TYPE PK22 90mm 23mm 61mm TD 45mm TD T1 C1 L1 VL2 VL3 N L1 L2 L3 12mm Figure 1 3.PTC Protection (Only Available in MKC-03P versions) 28mm 48 mm 58mm 58 mm 34 mm 10k 61.8 mm TYPE PK28 45.4 mm 35.3 mm 10 20 40 60 80 100 120 140160 180 200 90 mm TYPE PK25 45 mm 62 mm 100 90 mm 1k 35 mm When the coil temperature in motors exceeds Tc, the limit temperature of PTC, the output relay switches off immediately, Relay LED turns OFF. This feature is included only in MKC-03P. See following figure for typical resistance of PTC vs temperature characteristics for three different swiching temperatures (110 oC, 120 oC, 130 oC). changed upon request. If you want to disable the PTC protection of a device with PTC protection, the PTC terminals on the device must be short-circuited. 19mm 48mm 100k Temperature (0C) 32 mm 35 mm 48 mm 59.7 mm A4908 / Rev.5 36 mm
Benzer belgeler
MKC-03_04_A4946 Rev.1_A4947_rev_2_PK28.FH9
Bu olumsuz etkileri ortadan kaldracak þekilde tasarlanmþ olan nötrlü MKC 03A
ve nötrsüz MKC-04A Motor Koruma Röleleri aþa¤daki koruma fonksiyonlarn
MOTOR (FAZ) KORUMA ve FAZ SIRASI RÖLELERİ
Faz-Nötr aras gerilim dengesizli¤i (sabit) %40tan fazla oldu¤u anda çkþ rölesi
User Manual
: Tip PK 21 (SSR-04 için)
Tip PK 10 (LLM-02 için)
Tip PK 25 (SSRC-04 için)
: IP 20
: 0.3 kg (LLM-02 için)
: 0.25 kg (SSR-04, SSRC-04 için)
MKC05-05P - 06-06P - FR-02 TR EN A5049 R4.FH9
protection is generally too slow to assure
demurrage without tripping due to both its
electromechanical structure and the use of high current setting range.MKC-05-05P,
MKC-06-06P and FR-02 Motor Pr...
İndir - Entes
: 1 C/O with, 5A, 1250 VA, Cosj=1 (for MK-01P, type PK10)
1 C/O with, 8A, 2000 VA, Cosj=1
Genel Ürün Bilgi
Örneğin 460 V için, V = ( 460 / 380 ) x tablodan okunan kablo uzunluğu
Max cable lenght shown on this table is calculated on a voltage drop of 3% at a temperature of 25°C
For voltages different fro...
OVER AND UNDER VOLTAGE PROTECTION RELAYS EN AŞIRI ve
Failure to follow those instructions will result in death or serious injury.
Disconnect all power before working on equipment.
When the device is connected to the network, do not remove the front p...
AŞIRI / DÜŞÜK AKIM KORUMA RÖLELERİ
: 1 C/O, 8A, 2000 VA, Cosϕ=1
Ortam Sýcaklýðý
: -5 0C ; +55 0C
Koruma Sýnýfý
: IP 20
Boyutlar
: Tip PK 25 ve PK 28
Baðlantý Þekli
: Pano içine dikey veya klemens rayýna
Aðýrlýk
: 0.3 kg
MCC-1D - Entes
Failure to follow those instructions will result in death or serious injury.
Disconnect all power before working on equipment.
When the device is connected to the network, do not remove the front p...