inductive sensor
Transkript
inductive sensor
ñEdition: Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ[email protected] ñwww.turck.com inductive sensor Bi3U-M12-AP6X M12 x 1 17/4 45 50 LED 4 ● threaded barrel, M12 x 1 ● chrome-plated brass ● factor 1 for all metals ● magnetic field immune ● extended temperature range ● high switching frequency ● 3-wire DC, 10..0.30 VDC ● normally open, pnp output ● cable connection ñEdition: • 10.11.2006 Wiring diagram Type Ident-No. Bi3U-M12-AP6X 1634100 Rated operating distance Sn Mounting condition Assured switching distance Repetition accuracy Temperature drift Hysteresis ambient temperature 3 mm flush ð (0,81 x Sn) mm ð 2% ð ± 10 % ð ± 15 %, ð -25 °C v ï +70 °C 3... 15 % -30 ... + 85 °C Operating voltage Residual ripple 10... 30 V DC ð 10 % Uss DC rated operational current No-load current I0 ð 200 mA ð 15 mA Residual current Rated insulation voltage Short-circuit protection Voltage dip at Ie ð 0.1 mA ð 0.5 kV yes / cyclic ð 1.8 V Wire breakage / reverse polarity protection Output function Insulation class Switching frequency yes / complete 3-wire, normally open, pnp ÷ ð 3 kHz Housing style Dimensions Housing material Material active area End cap Housing nut tightening torque Connection cable quality Cable cross section: Vibration resistance Shock resistance Protection degree threaded barrel; M12 x 1 54 mm metal, CuZn, chrome-plated plastic, plastic, PA12-GF20 plastic, EPTR 10 Nm cable Ø 5.2, LifYY, PVC, 2 m 3 x 0.34 mm2 55 Hz (1 mm) 30g (11 ms) IP67 Switch state display LED yellow pnp BN + BU BK Function principle Inductive sensors are designed for wearfree and non-contact detection of metal objects. Due to a ferrite-less 3-coil system, uprox factor 1 sensors have distinct advantages. They detect all metals at the same switching distance, are magnetic field immune and feature large switching distances. Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ[email protected] ñwww.turck.com ñEdition: Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ[email protected] ñwww.turck.com inductive sensor Bi3U-M12-AP6X Mounting instructions Distance D Distance W Distance T Distance S Distance G minimum distances 2xB 3 x Sn 3xB 1,5 x B 6 x Sn Diameter of the active area B Ø 12 mm T G S D ñEdition: • 10.11.2006 W Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ[email protected] ñwww.turck.com ñEdition: Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ[email protected] ñwww.turck.com inductive sensor Bi3U-M12-AP6X Accessories Type code QM-12 IdentNo. 6945101 Short text Dimension drawing quick-mount fixing clamp with dead-stop; material: chrome-plated brass male thread M16 x 1. Note: The switching distance of proximity switches can be reduced by the use of quick mounting brackets. 22/4 ø 12 BST-12B 6947212 19,5 34 fixing clamp with dead-stop; material: PA6 M5 20 28 40 18 30 ñEdition: • 10.11.2006 ø 12 Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ[email protected] ñwww.turck.com
Benzer belgeler
inductive sensor
metal, A2 1.4301 (AISI 304)
plastic, PBT
plastic, EPTR
75 Nm
cable
Ø 5.2, LifYY, PVC, 2 m
3 x 0.34 mm2
55 Hz (1 mm)
30g (11 ms)
IP68
Inductive sensor
Mounting conditions
Assured switching distance
Repeatability
Temperature drift
Hysteresis
Ambient temperature